Military Engineer Services - Haryana

40392584 tender for special repair to scada system at edafstn under ge ( af ) gurgaon no.1; 1 supply and fixing of electromagnetic type flow meter for 80 nb size, with ip 66 protection, 1.4 kv isolation, accuracy of 0.5 mv, linearity of 0, 5% of mv, mounting in horizontal , 10kg / cm2 max pressure local indication through lcd display and rs 485 modbus rtu communication protocol, capable of working in ambient temperature of 0 deg c till 75 deg c and humidity upto 95% with response time of less than 1 sec, working on 90 250 vac, 50 hz with necessary flanges, nut, bolts, gasket and di / ci specials ll complete all as per specified as directed. note: the flow meter shall be provided with remote display unit that shall be installed in a ms enclosure on the wall or ground to prevent the electronic unit from being water logged. 2 s&f of scada ready actuated electric butterfly valve for water supply systems, with open area installation, line pressure maximum 7 bars, ends wafer, duty on / off, 230 vac / 24vdc, ip 67, enclusore, insulation class f, complete with travel swtich and torque switch of size 80 mm omplete all as per specified as directed. 3 s&f of scada ready actuated electric butterfly valve for water supply systems, with open area installation, line pressure maximum 7 bars, ends wafer, duty on / off, 230 vac / 24vdc, ip 67, enclusore, insulation class f, complete with travel swtich and torque switch of size 100 mm omplete all as per specified as directed. 4 rs 485 communication cable, two pairs stranded copper, ( 7*32 ) tinned copper conductors, polyethylene insulation, twister pairs, aluminium / polyster 100% coverage, tinned copper braid shield 90% coverage, 24 awg strained tinned copper drain wire, armoured , pvc jacket with the following specifications: ( i ) outer jacket : polyvinyl chloride, 0.34 in ( ii ) conductor dcr: 24 o / 1000ft ( iii ) nominal outer shleid dcr: 2.2 o / 100ft ( iv ) nominal capacitance conductor to conductor: 12.8μf / ft ( v ) nominal capacitance conductor to other conductor to shield: 23μf / ft ( vi ) nominal characterstics impedence: 120 o ( vii ) frequency : 1 mhz ( viii ) nominal insertion loss: 0.6 db / 100m 5 s&f of ultrasonic type water level sensor for underground sump at pump house 1 andpump house 2 suitable for upto 6 meter water level depth of u / g sump, with dead band of less than 0.6 meter, ip 66 protection, accuracy of 0.25% of f.s and rs485 modbus rtu communication protocol, capable for working in ambient temperature of 0 degrees to 75 degrees centrigrade, non condensing at 25 degree centrigrade and humidity up to 95% with response time of less than 1 sec with 230v ac to 24vdc, 50hz power supply lcd display type, vertical type mounting on top of oht or semi ug sump with all connections and fixing including clamp, nuts, bolts complete of adequate size all as specified 6 labour only for demolition of old unserviceable scada system, carefully taking down of unserviceable plc panel complete all as specified and directed.note unserviceable computer obtain from scada system deposited to mes store yard. 7 labour only for demolition of old unserviceable actuated valves of any sizes complete all as specified and directed 8 ( pump house 1 ) supply, installation, testing and commissioning of indoor type remote terminal unit based monitoring / control / annunciating control panelwith 2 years defect liability in a panel made out of 1.6 mm thick crca sheet for for 01 nos of submersible pump, 02 nos. centrifugal pumps , 02 no. motorized butterfly valve , 01 no. ultrasonic level sensor for monitoring of oh / semi ug sump, 02 nos. electromagmagnetic flowmeterand common automatic priming arrangement for the pump motor to sync with the scada panels with submersible motor of minimum 1 hp and adequate size of automatic air release valves and chlorination dosing system and dg amf controller. the panel shall consist of the following equipments: note: no charges towards internet and sim card shall be paid extra by the department. the system shall be included with sim card and internetactivitation and periodic recharges for 2 years, during defect liability period. ( i ) a programmable controller, with bidirectional operation on at least on modbus dnp3, mbus protocols ( all mandatory and selectable ) , having at least 1ghz quad core having operational temperature from 0 70degc ( commercial grade ) processor and 1gb ram, along with following type test certificates from any nabl approved lab ( the certificates must bear the nabl logo on it.conducted and radiated emission test as per cispr 22:2018, immunity to electrostatic discharge test as per iec 61000 4 2 ::2008, immunity to radiated test as per iec 61000 4 3 2010, immunity to fast transientstest as per iec 61000 4 42012, iec 61000 4 5:2014 ( up to 2 kv ) , immunity to rf field induced conducted disturbance test as per iec 61000 4 6:2013, power frequency iec 61000 4 8, dry heat iec 60068 2 30 ( per cycle ) damp heat iec 60068 2 30 ( per cycle ) , dielectric strengthcl.6.8 of iec 61010 1 9 ( ii ) with suitable digital and analog inputs / outputs, expansion modules, rtc etc. and hmi with display, ( iii ) gprs modem with 4g capability and fallback to 3g / 2g, having qmi / mbim / or any other non proprietary programming interface, the modem should be based on qualcomm / motorola processors and should provide seamless interface with programmable controller ( gprs modem inside of the programmable controllers are preferred as they provide seamless connectivity ) . ( iv ) transformer with regulated output voltage of 230v + / 5%, ( v ) smps of suitable rating. ( vi ) set of control relays and suitable mcb . ( vii ) audio visual generator etc. ( viii ) suitable no. of led indicators for easy visualisation ( ix ) selector swtiches ( x ) push buttons / illuminated push buttons ( xi ) 1.5 sqmm multistarnded internal wiring with ferruling and suitable lugs. ( xii ) .panel should communicate with scada, through the gprs.panel should be from any cpri approved scada oem approved control panel builder 10 ( pump house 2 ) supply, installation, testing and commissioning of indoor type remote terminal unit based monitoring / control / annunciating control panelwith 2 years defect liability in a panel made out of 1.6 mm thick crca sheet for for 01 nos of submersible pump, 02 nos. centrifugal pumps , 02 no. motorized butterfly valve , 01 no. ultrasonic level sensor for monitoring of oh / semi ug sump, 02 nos. electromagmagnetic flowmeterand common automatic priming arrangement for the pump motor to sync with the scada panels with submersible motor of minimum 1 hp and adequate size of automatic air release valves and chlorination dosing system and dg amf controller.. the panel shall consist of the following equipments: note: no charges towards internet and sim card shall be paid extra by the department. the system shall be included with sim card and internetactivitation and periodic recharges for 2 years, during defect liability period. ) ( i ) a programmable controller, with bidirectional operation on at least on modbus dnp3, mbus protocols ( all mandatory and selectable ) , having at least 1ghz quad core having operational temperature from 0 70degc ( commercial grade ) processor and 1gb ram, along with following type test certificates from any nabl approved lab ( the certificates must bear the nabl logo on it ) .conducted and radiated emission test as per cispr 22:2018, immunity to electrostatic discharge test as per iec 61000 4 2 ::2008, immunity to radiated test as per iec 61000 4 3 2010, immunity to fast transientstest as per iec 61000 4 42012, iec 61000 4 5:2014 ( up to 2 kv ) , immunity to rf field induced conducted disturbance test as per iec 61000 4 6:2013, power frequency iec 61000 4 8, dry heat iec 60068 2 30 ( per cycle ) . damp heat iec 60068 2 30 ( per cycle ) , 11 dielectric strengthcl.6.8 of iec 61010 1 ( ii ) with suitable digital and analog inputs / outputs, expansion modules, rtc etc. and hmi with display. ( iii ) gprs modem with 4g capability and fallback to 3g / 2g, having qmi / mbim / or any other non proprietary programming interface, the modem should be based on qualcomm / motorola processors and should provide seamless interface with programmable controller ( gprs modem inside of the programmable controllers are preferred as they provide seamless connectivity ) . ( iv ) transformer with regulated output voltage of 230v + / 5%. ( v ) smps of suitable rating. ( vi ) set of control relays and suitable mcb. ( vii ) audio visual generator etc. ( viii ) suitable no. of led indicators for easy visualisation ( ix ) selector swtiches ( x ) push buttons / illuminated push buttons ( xi ) 1.5 sqmm multistarnded internal wiring with ferruling and suitable lugs. ( xii ) .panel should communicate with scada, through the gprs.panel should be from any cpri approved scada oem approved control panel builder 12 supply, installation, testing and commissioning for scada software including creation & addition of screens to monitor and control of pump house 1 and pump house 2 withsoft keys for operate all the pumps and motorized butterfly valve of the mentioned pump houses as per the directions of the engineer in charge ( i ) scada software will report online trend for monitoring and should be capable of controlling devices. it should have all basic functionalities such as monitoring, control, historian ( for trend analysis ) , alarm generation, and reporting. ( ii ) scada software with various reporting options and can store minimum 3 years of data. ( iii ) scada software have bidirectional operation on at least on modbus dnp3, opc protocols. ( iv ) scada must have more than 500 tags. ( v ) the comprehensive software should be able to run on premise without any interaction with internet. however, remote access can be made available using optional features ( to be configured separately ) . ( vi ) it should have hot standby failover system ( vii ) scada must be optional feature of android app to monitor parameters without any additional cost. ( viii ) including internet for programmable controllers ( a ) comprehensive plan for 2 years period. ( ix ) all equipments mentioned above must be rs485 modbus or dnp3 enabled. any accessory required to make them scada enabled will be in contractors scope. ( x ) all above will be with 2 years defect liability period.the items also includes supply and installation of scada desktop pc with the following parameters: the items also includes supply and installation of scada desktop pc with the following parameters: processor 7th gen intel core tm i5 7200 u processor ( 3m cache, upto 3.10ghz ) / windows11homeplus / 64bit ) / msoffice, latest / 21inchfhd ( 1920x1080 ) anti glare led back lit display with wide viewing angle, ramemory 8gb single channel ddr4 2400mhz ( 8gbx01 ) / ssd512gb+harddrive 2tb, 1400rpm / graphic card nvdiag force 13 ( xi ) laserjetprinterblack&whitea4size ( tobeinstalledatinstalledatcontrolroomofengineer in charge. ( xii ) ups of capacity 1000va with 20 min backup to be installed 3m cache, upto 3.10ghz ) / windows10homeplus / 64bit ) / msoffice, latest / 21inchfhd ( 1920x1080 ) anti glare led back lit display with wide viewing angle, memory 8gb single channel ddr4 2400mhz ( 8gbx01 ) / ssd512gb+harddrive 2tb, 1400rpm / graphic card nvdiag force ( xiii ) laserjetprinterblack&whitea4size ( tobeinstalledatinstalledatcontrolroomofengineer in charge. ( xiv ) ups of capacity 1000va with 20 min backup to be installed 14 supplying and fixing 2 core 1.5 sqmm multistrand copper cable pvc insulated, laid up together pvc inner sheathed, gi wire braided, flexible armouring, overall pvc sheathed, steel braided cables as required complete all as specified and directed.note: rates include power cables to be laid as specified with gi / pvc pipe protection whereever deemed necessary. 15 supplying & fixing on wall / laying in ground 2 core 1.0 sqmm pvc insulated & pvc copper armored cable with heavy duty pvc saddles 60 cm apart complete all as specified and directed. 16 dg amf controller with scada interface microprocessor based controller for dg set with 3 or 4 analog channels which can be configured as both automatic and manualcontroller. • display: 128*64 pixel graphial backlit lcd for ease of readout and symbolic representation. • cyclic timer based engineoperation. maximum engine on time as well as rest time are programmable • fan current monitoring for canopy fan ( optional ) • menu driven mm1 for easy in field configuration without pc or any customized equipment. • load management. load dependent start / stop of 2nd dg in case of two dg application. • periodic automatic start of engine if not used for a predefined time to charge the battery as well as maintenance. • econ reminds user for timely service by indicating service due alarm. • true rms measurement of all measured parameters with 1% accuracy of measured value. • plug in connectors for error free replacement.programmable dg on delay, dg continuous on time, dg rest time, warm up time along with 33 other times. • automatic real time based dg start and stop ( manual control configuration. ) . protection and supervision mains measurements ? 1 phase / 3 phase voltage, 1 phase / 3 phase current ? frequency ? pf, kw, kva, • generator measurements ? 1 phase / 3 phase voltage ? 1 phase / 3 phase current ?frequency ?canopy fan current ? pf, kw, kva, kwh . ?battery voltage ?water temperature ?oil pressure ?fuel level ? rpm ? run hour ? service due hour • protection / supervision mains ?under / over voltage ?under / over frequency ?phase sequence ?voltage unbalance ?overload • protection / supervision dg ?under / over voltage ?under / over frequency ?current unbalance ?over speed ?overload ? rwl ? llop ? hwt ? lfl ?charging alternator / v belt ?emergency off ?service due ?fail to start ?fail to stop • 17 digital input : 10 digital [ 3 fixed, 4 programmable, 3 programmable ( optional ) ] • output: 9 digital operating instructions page 3 ? amf operation: 9 outputs ( five fixed and three programmable ) and one for charging alternator • fault data recording: last 64 fault with date and time stamping • event recording: last 64 event with date and time stamping • start stop recording: last 100 records with date and time stamping •password protection: three digit password protection for system settings. • real time clock ( rtc ) • communication: rs232, usb, fully isolated rs485 ( optional ) • provision for switching on or off the measurement for individual sensors. • option of warning or tripping when open sensor is detected • programmable crank cut off method based on either voltage built up, or oil pressure build up & voltage built up. 18 supply and fixing of electromagnetic type flow meter for 100 nb size, with ip 66 protection, 1.4 kv isolation, accuracy of 0.5 mv, linearity of 0, 5% of mv, mounting in horizontal , 10kg / cm2 max pressure local indication through lcd display and rx 485 modbus rtu communication protocol, capable of working in ambient temperature of 0 deg c till 75 deg c and humidity upto 95% with response time of less than 1 sec, working on 90 250 vac, 50 hz with necessary flanges, nut, bolts, gasket and di / ci specials ll complete all as per specified as directed.note: the flow meter shall be provided with remote display unit that shall be installed in a ms enclosure on the wall or ground to prevent the electronic unit from being water logged. 19 schedule of credit...

Haryana Sugar Federation - Haryana

39959791 tender for repairing of sanlac make avr repairing of avrfor 16mw , stg, sanlac makedetails of avr: 1. digital avr with auto control, auxiliary supply 110v dc, 230 v ac, decs 200 negative forcing digital excitation control system, pt supply 110v ac, 50hz, measuable voltage level 60 130 volts, nominal value adj(nua) setting 99 121v, control relay one pair of normally open potential free contacts operating 115 v a c @ 3a resistive load 230v ac @1.5a resistive load for each lower, raise and under voltage/over voltage and control failure relay....

Haryana Sugar Federation - Haryana

39117564 tender for repairing of sanlac make avr repairing of avrfor 16mw , stg, sanlac makedetails of avr: 1. digital avr with auto control, auxiliary supply 110v dc, 230 v ac, decs 200 negative sorcing digital excitation control system, pt supply 110v ac, 50hz, measuable voltage level 60 130 volts, nominal value adj(nua) setting 99 121v, control relay one pair of normally open potential free contacts operating 115 v a c @ 3a resistive load 230v ac @1.5a resistive load for each lower, vaise and under voltage/over voltage and control failure relay....

Northern Railway - Haryana

36845336 supply of contractor relay, 3 n / c + nc, dc current as per eaton part no; dila 31 ( 24 vdc ) , 15a, 600v / make eaton / moeller / cutler hammer, bch make control relay: d16cr31* ( 3no + 1nc ) . for zdm3 loco. [ warranty period: 30 months after the date of delivery ] ...

Haryana Sugar Federation - Haryana

33966889 supply of avr and relay spare digital avr with auto control auxiliary supply 110 v d.c , 230 v ac , decs 200n negative forcing digital excitation control system pt supply 110 v ac , 50 hz , measurable voltage level 60 130 volts , nominal value adj ( nva ) setting 99 121v, control relay one pair of normally open potential free contacts operating 115 v ac @ 3 a resistive load / 230 v ac @ 1.5 a resistive load foe each lower , raise and under voltage / over voltage and control failure relay make sanlec...

Haryana Sugar Federation - Haryana

33466113 avr and relay spare make sanlec avr and relay spare make sanlec , digital avr with auto control auxiliary supply 110 v d.c , 230 v ac , decs 200n negative forcing digital excitation control system pt supply 110 v ac , 50 hz , measurable voltage level 60 130 volts , nominal value adj(nva) setting 99 121v, control relay one pair of normally open potential free contacts operating 115 v ac @ 3 a resistive load /230 v ac @ 1.5 a resistive load foe each lower , raise and under voltage/ over voltage and control failure relay make sanlec...

Haryana Sugar Federation - Haryana

33062657 avr and relay spare make sanlac avr and relay spare make sanlac , digital avr with auto control auxiliary supply 110 v d.c , 230 v ac , decs 200n negative forcing digital excitation control system pt supply 110 v ac , 50 hz , measurable voltage level 60 130 volts , nominal value adj ( nva ) setting 99 121v, control relay one pair of normally open potential free contacts operating 115 v ac @ 3 a resistive load / 230 v ac @ 1.5 a resistive load foe each lower , raise and under voltage / over voltage and control failure relay make sanlec...

Indo Tibetan Border Police - Haryana

31002494 bids are invited for replacement of old faulty control relay of 180 kva dg set amf panel , replacement of hose pipe set (cumminsgenuine) and diesel return valve systemreplacement of old faulty control relay and replacement ofboq titlehose pipe set total quantity : 2...

Haryana Vidyut Prasaran Nigam Limited - Haryana

30865440 nit no. 50 / amb / 66 kv layalpur basti / 2021 22 replacement of power t / f, 66 kv ct, 66 kv and 11 kv nct, bus bar, control relay panel, 11 kv panels, laying of power and control cables at 66 kv s / stn layalpur basti...

Power Grid Corporation Of India Limited - Haryana

30768258 bids are invited for custom bid for services retrofitting andreplacement of control relay panel in powergridowned bauto extension if any seller submits price in last 15 minutes, the rawill be auto extended by 15 minutes. ( for anunlimited time ) total quantity :...

Haryana Vidyut Prasaran Nigam Limited - Haryana

30298685 nit no. 38/amb/66 kv sadopur/2021 22 replacement of power t/f, 66 kv and 11 kv nct, control relay panel, 11 kv panels, erection of power and control cables at 66 kv s/stn sadopur...

Haryana Vidyut Prasaran Nigam Limited - Haryana

29853087 nit no. 35 / amb / 66 kv adhoya / 2021 22 replacement of power t / f, 66 kv ct, 66 kv and 11 kv nct, control relay panel, 11 kv panels, erection of power and control cables at 66 kv s / stn adhoya...

Ministry Of Power - Haryana

28926787 bids are invited for custom bid for services retrofitting and replacement of control relay panel in powergrid owned bays at 220kv getco haldarwa substation 220kv getco vav substation and 220kv getco navsari substation...

National Hydroelectric Power Corporation Limited - Haryana

24697533 non comprehensive annual maintenance contract for one year for repair and maintenance of fire alarm system installed at neer shakti sadan , nhpc office complex , sector 33 , faridabad , non comprehensive amc of fire alarm system installed at neer shakti sadan office complex , faridabad as per scope of work . first year , optical smoke detector with inbuilt isolator make notifier , model nfxi opt iv , adderessable bases for optical smoke/ multi criteria/ fixed cum rate of rise heat detector make notifier , model b501ap/iv , multi criteria detector with inbuilt isolator make notifier , model nfxi smt1/iv , fixed cum rate of rise heat detector with inbuilt isolatormake notifier , model nfxi/tdif , conventional beam detector with relay module and fault isolatormake notifier , model 6500r , control relay modulemake notifier , model m701 240 , monitor module with inbuilt fault isolatormake notifier , model m701 , manual call point with inbuilt isolatormake notifier , model m701kaci fg , wall sounder/ strobe/ beacon redmake notifier , model nfxi wsf rr , low profile basemake notifier , model lpbw...

Northern Railway - Haryana

23633648 supply of , freedom control relay, (2no + 2nc), coil voltage : 415 vac, as per bch cat no. d15cr22m n, make : bch, abb, siemens, schneider...

Northern Railway - Haryana

22350456 supply of air break auxiliary control relay mxo22e(02 no+02nc)., air break auxiliary control relay mxo22e(02 no+02nc) , coil voltage 240 volts,50hz with 2no+2nc auxiliary contact block, screw terminal contacts rating 10 amp, ( screw din rail) mounting arrangement to model no cs94020 of l&t .make l&t, abb, bch, siemens ....

Haryana Power Generation Corporation Limited - Haryana

22062514 supply of c and s make material arc basis : thermal overload relays with mounting kit range 0 . 63 1 . 0 amp , type ( lri d09305 ) , thermal overload relays with mounting kit range 1 . 6 2 . 5 amp , type ( lri d09306 ) , thermal overload relays with mounting kit range 2 . 5 4 . 0 amp , type ( lri d09308 ) , thermal overload relays with mounting kit range 5 . 0 8 . 0 amp , type ( lri d09312 ) , thermal overload relays with mounting kit range 07 10 amps , lr1d09314 , thermal overload relays with mounting kit range 10 13 amps , lr1d12316 , thermal overload relays with mounting kit range 13 18 amps , lr1d16321 , thermal overload relays with mounting kit range 18 25 amps , lr1d25322 , thermal overload relays with mounting kit range 23 32 amps , lrd1d32353 , thermal overload relays with mounting kit range 30 40 amps , lr1d040355 , thermal overload relays with mounting kit range 38 50 amps , lr1d63357 , thermal overload relays with mounting kit range 48 57 amp , type ( lri d63359 ) , thermal overload relays with mounting kit range 57 66 amps , lr1d63361 , thermal overload relays with mounting kit range 66 80 amp , type ( lri d80363 ) , thermal overload relays with mounting kit range 65 105 amps , lr1f105 , thermal overload relays with mounting kit range 80 125 amps , lr1f125 , thermal overload relays with mounting kit range 125 200 amps , l1f200 , thermal overload relays with mounting kit range 160 250 amps , l1f250 , thermal overload relays with mounting kit range 200 315 amps , l1f315 , thermal overload relays with mounting kit 5 . 5 8 . 0 amps , lr1 d09312 , thermal overload relays with mounting kit 0 . 4 0 . 63 amps , lr1 d09304 , thermal overload relays with mounting kit 1 1 . 6 amps , lr1 d09306 , thermal overload relays with mounting kit 1 . 6 2 . 5 amps , lrd 07 , thermal overload relays with mounting kit 04 06 amps , lrd 10 , thermal overload relays with mounting kit 63 80 amps , thermal overload relays with mounting kit 100 160 amps , lr1 f160 , sfu 32a , 3p , for module / feeder , type af / drg . no . 515 , & au / drg . no . 517 , css df32d3 , sfu , 63 a , 3p , for module / feeder , type bf / drg . no 515 , bf / drg . no 555 , bu / drg . no 568 , css df63d3 , sfu , 125 a , 3p , for module / feeder , type cf / drg . no . 515 , cu / drg . no . 568 , du / drg . no . 569 , css df125d3 , sfu , 250 a , 3p , for module / feeder , type eu / drg . no . 569 , css df250d3 , power contactors ( coil voltage 110 v ac ) 09 amps , tc1d0910 , power contactors ( coil voltage 110 v ac ) 16 amps , lc1d173f , power contactors ( coil voltage 110 v ac ) 32 amps , lc1d323f , power contactors ( coil voltage 110 v ac ) 50 amps , tc1d5011 , power contactors ( coil voltage 110 v ac ) 63 amps , lc1d633 , power contactors ( coil voltage 110 v ac ) 70 amps , tc1d7011 , power contactors ( coil voltage 110 v ac ) 115 amps , lc1fdp115af , power contactors ( coil voltage 110 v ac ) 150 amps , lc1fdp150a , power contactors ( coil voltage 110 v ac ) 185 amps , lc1fdp185af , power contactors ( coil voltage 110 v ac ) 330 amps , lc1fdp330a , power contactors ( coil voltage 110 v ac ) 18 amps , power contactors ( coil voltage 110 v ac ) 40 amps , power contactors ( coil voltage 110 v ac ) 25 amps , power contactors ( coil voltage 110 v ac ) 12 amps , aux . contactor , 10 a ( control relay ) coil voltage 110v ac 2no+2nc , tca 2dn22 , aux . contactor , 10 a ( control relay ) coil voltage 110v ac 3no+1nc , tca 2dn31 , aux . contactor , 10 a ( control relay ) coil voltage 110v ac 4no , tca 2dn40 , aux . contactor , 10 a ( control relay ) coil voltage 220 v dc 2no+2nc , tca 3dn22 , aux . contactor , 10 a ( control relay ) coil voltage 220 v dc 3no+1nc , tca 3dn31 , aux . contactor , 10 a ( control relay ) coil voltage 220 v dc 4no , tca 3dn40 , contactor add on block 2 no+2 nc , laid22 , contactor add on block 4 no , laid40 , contactor add on block no+1 nc , laid31 , mpcb 0 . 63 1 . 0 amp . , tcms 32s 1 , mpcb 1 . 6 2 . 5 amp . , tcms 32s 2 . 5 , mpcb 2 . 5 4amp . , tcms 32s 4 , mpcb 5 8amp . tcms 32s 8 , mpcb 9 13 amp . tcms 32s 13 , mpcb 18 26 amp . tcms 32s 26 , mpcb 28 40amp . tcms 32s 40 , mpcb 45 63amp . tcms 32s 63 , circuit breaker coils 220 v dc closing coil avh c 116 / 220 / md , cs avh c 1 , circuit breaker coils 220 v dc tripping coil avh s 116 / 220 / md , cs avh c 2 , spring charging motor for 40 d breakers , 220 vdc , amh 2 , spring charging motor for 16 d breakers , 220 vdc , amh 1 , pole assembly for breakers single pole unit for 6d , condunit 6d , pole assembly for breakers single pole unit for 8d , condunit 8d , pole assembly for breakers single pole unit for 10d , condunit 10d , pole assembly for breakers single pole unit for 12d , condunit 12d , pole assembly for breakers single pole unit for 16d , condunit 16d , pole assembly for breakers single pole unit for 20d , condunit 20d , pole assembly for breakers single pole unit for 25d , condunit 25d , pole assembly for breakers single pole unit for 30d , condunit 30d , pole assembly for breakers single pole unit for 40d , condunit 40d , arcing contact ( fixed + moving ) for acb , d type , 50 ka rating 8 d , arccont 8d , arcing contact ( fixed + moving ) for acb , d type , 50 ka rating 10 d , arccont 10d , arcing contact ( fixed + moving ) for acb , d type , 50 ka rating 16 d , arccont 16d , arcing contact ( fixed + moving ) for acb , d type , 50 ka rating 25d , arccont 25d , arcing contact ( fixed + moving ) for acb , d type , 50 ka rating 30 d , arccont 30d , auxiliary switch for breaker ( 14 way 7 no+7nc ) 6d 16d for 10d acb , cs axh 7a7b 1 , auxiliary switch for breaker ( 14 way 7 no+7nc ) 20d 40d , cs axh 7a7b 2 , main fixed contact for acb , d type , 50 ka rating 8 d , fixcont 8d , main fixed contact for acb , d type , 50 ka rating 10 d , fixcont 10d , main fixed contact for acb , d type , 50 ka rating 16 d , fixcont 16d , main fixed contact for acb , d type , 50 ka rating 25d , fixcont 25d , main fixed contact for acb , d type , 50 ka rating 30 d , fixcont 30d , main moving contact for acb , d type , 50 ka rating 8 d , movmain 8d , main moving contact for acb , d type , 50 ka rating 10 d , movmain 10d , main moving contact for acb , d type , 50 ka rating 16 d , movmain 16d , main moving contact for acb , d type , 50 ka rating 25d , movmain 25d , main moving contact for acb , d type , 50 ka rating 30 d , movmain 30d , acb dr frame safety shutter 1000a , ash 1 , acb lower mechanism for acb , d type , 50 ka rating 8d , lwrmech06 8d , acb lower mechanism for acb , d type , 50 ka rating 25d , lwrmech25d , acb lower mechanism for acb , d type , 50 ka rating 30 d , lwrmech30d , acb complete mechanism ( without side plate &conductor assy . ) for acb , d type , 50 ka rating 8 d , mech06 16 d3pdo , acb complete mechanism ( without side plate &conductor assy . ) for acb , d type , 50 ka rating 25d , mech25d3pdo , acb complete mechanism ( without side plate &conductor assy . ) for acb , d type , 50 ka rating 30 d , mech30d3pdo , drawout warm gear assembly , dowrmgr 116 , dr lever ( left ) with roller , csj3135 , dr lever ( right ) with roller , csj3136 , aux . isolating contact blocks acb & cradle side 12 way ( oder together for breaker and cradle side ) , aih bc , pole separator ( barrier ) , pole septr 6 16 , breaker limit switch , limsw , arc chutes for acb , d type , 50 ka rating 8 d , arccht06 8 d , arc chutes for acb , d type , 50 ka rating 25d , arccht25d , arc chutes for acb , d type , 50 ka rating 30 d , arccht30d , emergency push button with 2no + 2nc , rb2 bs 54 , start push button with 2no + 2nc , rcb2 ba3 , stop push button with 2no + 2nc , rcb2 ba4 , c...

Northern Railway - Haryana

21978900 supply of air break auxiliary control relay mxo22e(02 no+02nc)., air break auxiliary control relay mxo22e(02 no+02nc) , coil voltage 240 volts,50hz with 2no+2nc auxiliary contact block, screw terminal contacts rating 10 amp, ( screw din rail) mounting arrangement to model no cs94020 of l&t .make l&t, abb, bch, siemens ....

Haryana Power Generation Corporation Limited - Haryana

21909991 supply of c and s make material arc basis : thermal overload relays with mounting kit range 0 . 63 1 . 0 amp , type ( lri d09305 ) , thermal overload relays with mounting kit range 1 . 6 2 . 5 amp , type ( lri d09306 ) , thermal overload relays with mounting kit range 2 . 5 4 . 0 amp , type ( lri d09308 ) , thermal overload relays with mounting kit range 5 . 0 8 . 0 amp , type ( lri d09312 ) , thermal overload relays with mounting kit range 07 10 amps , lr1d09314 , thermal overload relays with mounting kit range 10 13 amps , lr1d12316 , thermal overload relays with mounting kit range 13 18 amps , lr1d16321 , thermal overload relays with mounting kit range 18 25 amps , lr1d25322 , thermal overload relays with mounting kit range 23 32 amps , lrd1d32353 , thermal overload relays with mounting kit range 30 40 amps , lr1d040355 , thermal overload relays with mounting kit range 38 50 amps , lr1d63357 , thermal overload relays with mounting kit range 48 57 amp , type ( lri d63359 ) , thermal overload relays with mounting kit range 57 66 amps , lr1d63361 , thermal overload relays with mounting kit range 66 80 amp , type ( lri d80363 ) , thermal overload relays with mounting kit range 65 105 amps , lr1f105 , thermal overload relays with mounting kit range 80 125 amps , lr1f125 , thermal overload relays with mounting kit range 125 200 amps , l1f200 , thermal overload relays with mounting kit range 160 250 amps , l1f250 , thermal overload relays with mounting kit range 200 315 amps , l1f315 , thermal overload relays with mounting kit 5 . 5 8 . 0 amps , lr1 d09312 , thermal overload relays with mounting kit 0 . 4 0 . 63 amps , lr1 d09304 , thermal overload relays with mounting kit 1 1 . 6 amps , lr1 d09306 , thermal overload relays with mounting kit 1 . 6 2 . 5 amps , lrd 07 , thermal overload relays with mounting kit 04 06 amps , lrd 10 , thermal overload relays with mounting kit 63 80 amps , thermal overload relays with mounting kit 100 160 amps , lr1 f160 , sfu 32a , 3p , for module / feeder , type af / drg . no . 515 , & au / drg . no . 517 , css df32d3 , sfu , 63 a , 3p , for module / feeder , type bf / drg . no 515 , bf / drg . no 555 , bu / drg . no 568 , css df63d3 , sfu , 125 a , 3p , for module / feeder , type cf / drg . no . 515 , cu / drg . no . 568 , du / drg . no . 569 , css df125d3 , sfu , 250 a , 3p , for module / feeder , type eu / drg . no . 569 , css df250d3 , power contactors ( coil voltage 110 v ac ) 09 amps , tc1d0910 , power contactors ( coil voltage 110 v ac ) 16 amps , lc1d173f , power contactors ( coil voltage 110 v ac ) 32 amps , lc1d323f , power contactors ( coil voltage 110 v ac ) 50 amps , tc1d5011 , power contactors ( coil voltage 110 v ac ) 63 amps , lc1d633 , power contactors ( coil voltage 110 v ac ) 70 amps , tc1d7011 , power contactors ( coil voltage 110 v ac ) 115 amps , lc1fdp115af , power contactors ( coil voltage 110 v ac ) 150 amps , lc1fdp150a , power contactors ( coil voltage 110 v ac ) 185 amps , lc1fdp185af , power contactors ( coil voltage 110 v ac ) 330 amps , lc1fdp330a , power contactors ( coil voltage 110 v ac ) 18 amps , power contactors ( coil voltage 110 v ac ) 40 amps , power contactors ( coil voltage 110 v ac ) 25 amps , power contactors ( coil voltage 110 v ac ) 12 amps , aux . contactor , 10 a ( control relay ) coil voltage 110v ac 2no+2nc , tca 2dn22 , aux . contactor , 10 a ( control relay ) coil voltage 110v ac 3no+1nc , tca 2dn31 , aux . contactor , 10 a ( control relay ) coil voltage 110v ac 4no , tca 2dn40 , aux . contactor , 10 a ( control relay ) coil voltage 220 v dc 2no+2nc , tca 3dn22 , aux . contactor , 10 a ( control relay ) coil voltage 220 v dc 3no+1nc , tca 3dn31 , aux . contactor , 10 a ( control relay ) coil voltage 220 v dc 4no , tca 3dn40 , contactor add on block 2 no+2 nc , laid22 , contactor add on block 4 no , laid40 , contactor add on block no+1 nc , laid31 , mpcb 0 . 63 1 . 0 amp . , tcms 32s 1 , mpcb 1 . 6 2 . 5 amp . , tcms 32s 2 . 5 , mpcb 2 . 5 4amp . , tcms 32s 4 , mpcb 5 8amp . tcms 32s 8 , mpcb 9 13 amp . tcms 32s 13 , mpcb 18 26 amp . tcms 32s 26 , mpcb 28 40amp . tcms 32s 40 , mpcb 45 63amp . tcms 32s 63 , circuit breaker coils 220 v dc closing coil avh c 116 / 220 / md , cs avh c 1 , circuit breaker coils 220 v dc tripping coil avh s 116 / 220 / md , cs avh c 2 , spring charging motor for 40 d breakers , 220 vdc , amh 2 , spring charging motor for 16 d breakers , 220 vdc , amh 1 , pole assembly for breakers single pole unit for 6d , condunit 6d , pole assembly for breakers single pole unit for 8d , condunit 8d , pole assembly for breakers single pole unit for 10d , condunit 10d , pole assembly for breakers single pole unit for 12d , condunit 12d , pole assembly for breakers single pole unit for 16d , condunit 16d , pole assembly for breakers single pole unit for 20d , condunit 20d , pole assembly for breakers single pole unit for 25d , condunit 25d , pole assembly for breakers single pole unit for 30d , condunit 30d , pole assembly for breakers single pole unit for 40d , condunit 40d , arcing contact ( fixed + moving ) for acb , d type , 50 ka rating 8 d , arccont 8d , arcing contact ( fixed + moving ) for acb , d type , 50 ka rating 10 d , arccont 10d , arcing contact ( fixed + moving ) for acb , d type , 50 ka rating 16 d , arccont 16d , arcing contact ( fixed + moving ) for acb , d type , 50 ka rating 25d , arccont 25d , arcing contact ( fixed + moving ) for acb , d type , 50 ka rating 30 d , arccont 30d , auxiliary switch for breaker ( 14 way 7 no+7nc ) 6d 16d for 10d acb , cs axh 7a7b 1 , auxiliary switch for breaker ( 14 way 7 no+7nc ) 20d 40d , cs axh 7a7b 2 , main fixed contact for acb , d type , 50 ka rating 8 d , fixcont 8d , main fixed contact for acb , d type , 50 ka rating 10 d , fixcont 10d , main fixed contact for acb , d type , 50 ka rating 16 d , fixcont 16d , main fixed contact for acb , d type , 50 ka rating 25d , fixcont 25d , main fixed contact for acb , d type , 50 ka rating 30 d , fixcont 30d , main moving contact for acb , d type , 50 ka rating 8 d , movmain 8d , main moving contact for acb , d type , 50 ka rating 10 d , movmain 10d , main moving contact for acb , d type , 50 ka rating 16 d , movmain 16d , main moving contact for acb , d type , 50 ka rating 25d , movmain 25d , main moving contact for acb , d type , 50 ka rating 30 d , movmain 30d , acb dr frame safety shutter 1000a , ash 1 , acb lower mechanism for acb , d type , 50 ka rating 8d , lwrmech06 8d , acb lower mechanism for acb , d type , 50 ka rating 25d , lwrmech25d , acb lower mechanism for acb , d type , 50 ka rating 30 d , lwrmech30d , acb complete mechanism ( without side plate &conductor assy . ) for acb , d type , 50 ka rating 8 d , mech06 16 d3pdo , acb complete mechanism ( without side plate &conductor assy . ) for acb , d type , 50 ka rating 25d , mech25d3pdo , acb complete mechanism ( without side plate &conductor assy . ) for acb , d type , 50 ka rating 30 d , mech30d3pdo , drawout warm gear assembly , dowrmgr 116 , dr lever ( left ) with roller , csj3135 , dr lever ( right ) with roller , csj3136 , aux . isolating contact blocks acb & cradle side 12 way ( oder together for breaker and cradle side ) , aih bc , pole separator ( barrier ) , pole septr 6 16 , breaker limit switch , limsw , arc chutes for acb , d type , 50 ka rating 8 d , arccht06 8 d , arc chutes for acb , d type , 50 ka rating 25d , arccht25d , arc chutes for acb , d type , 50 ka rating 30 d , arccht30d , emergency push button with 2no + 2nc , rb2 bs 54 , start push button with 2no + 2nc , rcb2 ba3 , stop push button with 2no + 2nc , rcb2 ba4 , c...

Department Of Irrigation - Haryana

21005209 supply of exhaust fan h / d etc : 1 exhaust fan h / d, v / 230, 50 hz, sweep 450 mm rpm 1400, make havell’s / usha 2 tin ingot superior quality 3 plastic moulded chair superior quality h / d make nilkamal / chairman / italica 4 coconut stick broom superior quality 5 pvc insulated power cable 630 mm2 650 / 1100 volt, al. conductor armoured single core, isi marked make havell’s / finolex / grandlay 6 spare contact kit for mnx 185 contactor make l&t 7 old dhoti full size, multi color / cotton 8 power hacksaw blade 525x40x2 mm high speed steel, premium quality make l&t 9 electronic over current relay 220 v, 50 hz, bocr 55 make bch / l&t / siemens 10 copper strip 1 / 8”x3 / 4” superior quality 11 mxo ac control relay 2 no + 2 nc, ac 15, 415 v make l&t 12 mx ai 11 e add on contact block make l&t 13 mxo 31 e contractor relay 415 v, 50 hz make l&t 14 power contactor 3 pole mnx 185 make l&t 415 v 15 power contactor 3 pole mnx 325 415 v make l&t 16 power contactor 3 pole mnx 225 415 v make l&t 17 power contactor 3 pole mnx 140 415 v make l&t...

Haryana Power Generation Corporation Limited - Haryana

20697346 supply of c and s make material arc basis 26 thermal overload relays with mounting kit 100 160 amps, lr1 f160 27 sfu 32a,3p, for module/feeder, type af/ drg. no. 515, & au/drg. no.517, css df32d3 28 sfu, 63 a,3p, for module/feeder, type bf/drg. no 515,bf/drg. no 555,bu/drg. no 568, css df63d3 29 sfu, 125 a ,3p, for module/feeder, type cf/drg. no.515,cu/drg. no.568,du/drg. no.569, css df125d3 30 sfu, 250 a,3p,for module/feeder, type eu/drg. no. 569, css df250d3 power contactors (coil voltage 110 v ac) 09 amps, tc1d0910 31 32 power contactors (coil voltage 110 v ac) 16 amps, lc1d173f 33 power contactors (coil voltage 110 v ac) 32 amps, lc1d323f 34 power contactors (coil voltage 110 v ac) 50 amps, tc1d5011 35 power contactors (coil voltage 110 v ac) 63 amps, lc1d633 36 power contactors (coil voltage 110 v ac) 70 amps, tc1d7011 37 power contactors (coil voltage 110 v ac) 115 amps, lc1fdp115af item37 38 power contactors (coil voltage 110 v ac) 150 amps, lc1fdp150a item38 39 power contactors (coil voltage 110 v ac) 185 amps, lc1fdp185af item39 40 power contactors (coil voltage 110 v ac) 330 amps, lc1fdp330a item40 41 power contactors (coil voltage 110 v ac) 18 amps item41 42 power contactors (coil voltage 110 v ac) 40 amps item42 43 power contactors (coil voltage 110 v ac) 25 amps item43 44 power contactors (coil voltage 110 v ac) 12 amps item44 45 aux. contactor,10 a (control relay) coil voltage 110v ac 2no+2nc, tca 2dn22 item45 46 aux. contactor,10 a (control relay) coil voltage 110v ac 3no+1nc, tca 2dn31 item46 aux. contactor,10 a (control relay) coil voltage 110v ac 4no, tca 47 2dn40 item47 48 aux. contactor,10 a (control relay) coil voltage 220 v dc 2no+2nc, tca 3dn22 item48 49 aux. contactor,10 a (control relay) coil voltage 220 v dc 3no+1nc, tca 3dn31 item49 50 aux. contactor,10 a (control relay) coil voltage 220 v dc 4no, tca 3dn40 item50 => open tender...

Bhakra Beas Management Board - Haryana

20064973 design, manufacture, testing before dispatch, supply, delivery, testing & commissioning at site of five nos. 220 kv duplex type control & replay panels and two no. 66 kv simplex type control & relay panels with numerical protection relays at 220 kv substations bmb, jagadhri, kurukshetra and delhi....

Indian Air Force - Haryana

19127597 repair of lmtc equipments: lmtc to test control unit 2 w, lmtc for phase squence relay, lmtc for 5g ( under carriage position indicator ) , lmtc for flap control relay, time delay relay, lmtc for ajax axtuator and diff t / p potentiometer, lmtc for time delay relay, lmtc for diff t / p actuator feedback potentrometer...

Cooperative Sugar Mills Societies - Haryana

7803402 internal and external cleaning work of boiler, replacement of emitting and collecting electrode plate, opening, repair, assemble and fitting of travelling grate of boiler, ultrasonic, mpi, thickness and highness testing of various machinery, dismantling, cleaning, assembling and fitting of carrier chain, dismantling, repair and overhauling of power turbine, machining and grooving of bearing housing, dismantling, fabrication and erection in various houses, checking and repairing of vcb, sand blasting work, repair of welding sets, electrification work in various houses, stress reliving of mill rollers and shafts, calibration of master calibration instruments, repair of jumbo display, bricks transmitter, servicing and gas filling work of breaker, overhauling, tape changer service of power and distribution transformer, reselling of rollers, testing of relay panel, and switch yard control relay panel, retubing of oil cooler, pit cleaning work, painting work...

East-Northern Railway - Haryana

3970496 supply of ciation m control relay as per cat. no.m d20 cr 22 or equivalent coil voltage 415v ac suitible for mounting in ac control panel of under slung type ac coaches. ...