Military Engineer Services - Haryana

40820371 tender for special repair to bldg no p 529 & p 773 at chandimandir mil station.; 1 demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. 2 brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6, complete all as specified and directed. 3 powder coated aluminium ( minimum thickness of powder coating 50 micron ) work for doors, windows, ventilators and partitions ( fixed portions ) with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete all as specified and directed. 4 powder coated aluminium ( minimum thickness of powder coating 50 micron ) for shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of epdm rubber / neoprene gasket required ( fittings shall be paid for separately ) with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, locking rollers etc all complete as per architectural drawings and the directions of engineer in charge. 5 3mm thick aluminium composite panel sheet ( acp ) fixed with aluminium anodised beading and rubber packing with all the clips and fittings colour as approved by engr in charge complete all as specified and directed. 6 5.00mm thick ordinary quality tinted glass, fixed to aluminum frame workin panels exc 0.5 sqm in each pane, complete all as specified & directed. 7 12mm thick toughned glass fixed in aluminium frame / shutter, windows frames with aluminium anodised beading and rubber packing in panels exc 0.5 sqm in each pane complete all as specified and directed. 8 4mm thick false ceiling fibre cement board, white in colour , 595mm x 595mm in size, fire and moisture resistance, fixed with and including standard gi snap grid framing ( powder coated ) and suspended not exceeding 900mm below from ceiling with 3mm dia wire including clips and misc fittings etc in pattern as approved by ge, fixed as in repair ( size of panel shall be of 605 x 605mm and gi snap grid framing shall be of 1mm thick standard section i.e. channels, angles, tee etc ) complete all as specified and directed. 9 linear ceiling system comprises of 84mm x 16mm panel without flush profile ( for 100mm module oniy ) roll formed out of metal coils of powder coated galvanised steel. panels are fixed on to roll formed carriers 32mm wide x39mm deep made out of 0.90mm powder coated aluminium or 0.50mm galvanised powder coated steel sheet with cutouts to hold the panels in module of 100mm at maximum 1.50mm without insulation. carriers are suspended from the roof or truss by 4mm dia galvanised steel wire rod hangers with special height adjustment suspended clips at max 1.20 metre centre to centre. hangers are fixed to the roof by ceiling brackets. no joint is permissible for length less than 4.0m. edge profiles or wall angles are 24mm x 24mm x 0.40mm thick and match the colour of the panel complete all as specified and directed. 10 toughened glass, 12 mm thick tempered, for decorative / crest, plain / frosted, cut to size, polished edge, homogenious colour fixed as in glass door shutter or glass partition including necessary holes, cutouts & shunk holes and necessary fittings, fixtures, brackets and accessories required like stainless steel hinges, floor door closer, latches, handle or knobs, stop plate etc including ruber beading and silicon clear for joints, complete all as specified and directed by engineer in charge.note : decoration / design or unit name, emblem, crest over glass shutter will be approved by engr in charge before execution and the rates are inclusive of the same. 11 door closer hydraulically regulated of aluminium extruded section, designation no. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg, complete all as specified and directed. 12 double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty , complete all as specified and directed. 13 200mm stainles steel handle fancy type fixed to toughened glass complete all as specified and directed. 14 taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. complete all as specified and directed. 15 15mm thick rendering in cement and sand mortar 1:6 over concrete / brick surfacesfinished even and smooth without using extra cement, complete all as specified & directed. 16 15mm thick rendering in cement and sand mortar 1:4 over brick or concrete surfaces finished even and smooth with using extra cementcomplete all as specified. 17 pvc false ceiling 8 10mm thick, coloures, prelaminated on one side of decortative choice or approved design and balancing white on other side ( seamless type ) suitably placed in false ceiling grid made of aluminium / g.i. / m.s. as per specification and drawing, complete all as specified & directed 18 demolition of mud in roofs, any thickness, including plastering and leeping ( whether full thickness removed or only a part thereof ) , complete all as specified and as directed. 19 pcc 1:2:4 type b 0 ( 12.5 mm graded stone aggs ) as in roof padding, roof kerbs ( 50mm thick average thickness ) rounded or chamfered on edgescomplete all as specified and directed. 20 3mm thick atactic polypropylene polymer ( app ) based polymeric membrane minimum weighing 3.6kg / sqm andreinforced with polyester non woven fabric ( weight not less than 150 gm / sqm ) laid over a coat of bitumen primer @0.40l / sqm by same membrane manufacturer of density 0.87 to 0.89 kg / l at 25° c temperature and viscosity 70 to 160 cps, over primer coat bonding material of blown bitumen 85 / 25 grade heated to working temperature of 180° c applied @1.2kg / sqm. the membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions complete all as specified & directed. 21 rendering 15mm thick ( average thickness ) plaster in cement mortar 1:4 on concrete roof / wallsurfaces including flashings and junction of parapets etc , finishing the surface even and fair without using extra cement all as specified and directed by engineer in charge. 22 dismantling of existing brick tiles or terracing tiles single layer on roof grouted in cement mortar including removal of any existing treatment complete all as specified & directed. 23 40mm thick brick tiles over and including 15mm thick cement mortar 1:4 joints, grouted & pointed flush as the work proceedsmixed with crude oil 5% by wt of cement complete all as specified and directed. 24 all as per item no 23 here in before but except tiles. 25 2mm thick wall care putty over wall surfaces including two coats of 100% premium acrylic plastic emulsion paint over a coat ofpriming paint including preparation of new wall surfacescomplete all as specified and directed. 26 complete removal of existing treatment and preparation of old plastered or unplastered surfaces of walls including 2mm thick wall care putty and applyingtwo coats of 100% premium acrylic plastic emulsion paint over a coat of primer complete all as specified and directed. 27 two coats of 100% premium acrylic exterior emulsion paint over a coat ofpriming paint including preparation of new wall surfacescomplete all as specified and directed. 28 preparation of old plastered or unplastered surfaces of walls and applying one coat of exterior weather proof acrylic emulsion paint on external walls complete all as specified and directed. 29 demolition of un reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness. ( below or above ground level ) complete all as specified and directed. 30 25mm thick plain cement concrete 1:2:4 type b 0 using 12.5mm graded aggregate as in sub base complete all as specified & directed. 31 double charged coloured vitrified ceramic tiles 10mm thick ( square / rectangular ) polished, dark shade, area of each tiles exc 0.42 sqm but n.exc 1.00 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over a 15mm thick screed bed in cement mortar 1:6complete all as specified and directed 32 coloured vitrified ceramic tiles, light shade, 8 10mm thick ( square ) , area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. 33 coloured non skid porcelain tiles exterior grade 400x400x9 10mm thick heavy duty ( endura from johnson or equivalent ) as in floor, set and jointed in neat slurry and pointed in coloured cement to match the colour of tiles over and including screed bed or bedding layer of 15mm thick in cement mortar 1:6, complete all as specified and directed 34 plain cement concrete 1:4:8 type d 2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed. 35 75mm thick pcc 1:3:6type c 1 using 20 mm graded stone aggregate laid in alternative bays as in plinth protection including finishing the surface even & fair & filling the joints with mastic filling i.e one part of bitumen 85 / 25 and 3 parts of sand by weightall as specified & directed by engineer in charge. 36 precast cement concrete louvres and jallies, 40mm thick ( measured solid ) type b0 ( 12.5mm aggregate ) set in cement mortar ( 1:4 ) , including all mouldings but excluding frame, fixed in repairs , complete all as specified & directed. 37 providing reinforced cement concrete type b l, 1:2:4 ( 20 mm graded aggregate ) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exc 100 sqcm, but n.exc 250 sqcmwith or without chamfered angles and flat, splayed, rounded or mitred tops complete all as specified & directed. 38 reinforced cement concrete 1:1½:3 ( nominal mix, type a 1, using 20mm graded crushed stone aggregate ) as in beams, cantilevers , bressumers, lintels over 1.5m span, all as specified and directed . 39 reinforced cement concrete , 1:1½:3 ( nominal mix, type a 1, using 20mm graded crushed stone aggregate ) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete , all as specified and directed. 40 reinforced cement concrete , 1:1½:3 ( nominal mix, type a 1, using 20mm graded crushed stone aggregate ) as in columns, pillars, piers, posts and strutsand the like complete all as specified and directed ( reinforcement shall be measured and paid for separately ) . 41 formwork to sides of pillars, posts, struts, piers, columns and stanchionsrough finished surface of flat concrete complete all as specified and directed. 42 mild steel high strength deformed tmt bars 10mm dia and over, cut to length, bent to shape required, including cranking, bendingspirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9 mm dia. or securing with clips complete all as specified and directed. 43 all as per serial item no 42 herein before but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, ditto 44 rolled mild steel work as in roof trusses ( framed ) trussed, purlins, crane gantries, rails and fastening and heavy bracket framing ( beam, tee, angle, channel or flat sections ) including distance pieces, cleats etc , gde fe 410 s, including a priming coat of red oxide zinc chrome primer, complete all as specified & directed. 45 framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to fe.290.gde e 165 ( brackets over 10 kg each to be measured under structural steel ) complete all as specified and directed. 46 excavation in post holes ( or similar hole ) each in hard and dense soil, n.exc 0.50 cu m getting out and removing surplus spoil at a distance not exc 50 metre and making good surfaces complete all as specified and directed. 47 pre painted galvalume aluminium zinc coating gi based corrugated steel sheeting 0.50 mm thick any colour having tensile strength 550 mpa as in roof coverings / cladding to wall, fixed with self tapping screws etc, complete all as specified & directed by engineer in charge. 48 preparation of new or previously untreatedsteel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint ( ordinary tint ) over a coat of red oxide, zinc chrome complete all as specified and directed. 49 taking down chowkats or frame n. exc. 1.5 sqm each with shutters ( without taking off shutters from the frame ) complete all as specified and directed. 50 500 litres capacity rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) double layered, screwable lid, hoisted and fixed in position, including tank nipple, float valve, ball valve 20mm ptmt, complete all as specified and directed . 51 1000 litres capacity rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) double layered, screwable lid, hoisted and fixed in position, including tank nipple, float valve, ball valve 20mm ptmt, complete all as specified and directed . 52 granite slab 16 18mm thick ( of any type & shade as approved ) , as in steps, jambs, pillars , window cill, cooking platfrom, counter slabetc ( length and width as ordered by ge in one piece ) best quality machine cut and jointed with grey cement slurry and pointed in white cement mixed with pigment to match the shade of slab laid over and including15mm thick screed bed in cement mortar 1:4 including nosing at edges, rounded edges complete all as specified and directed. 53 glazed ceramic tiles in vertical surface350x250x7mm / 450x350x7mm thick, joint free, first quality, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over 10mm thick rendering in cement mortar 1:4 , complete all as specified and directed. 54 glazed ceramic texture / designer type, exterior wall tiles in vertical surface 300mm x 450mm x 7mm thick, joint free, first quality, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over 10mm thick rendering in cement mortar 1:4 , complete all as specified and directed. 55 excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by engineer in charge. 56 3mm thick aluminium composite panel sheet ( acp ) including ms frame work for support as in wall cladding, covering of fasade and like colour of acp sheet as approved by engr in charge complete all as specified and directed. 57 returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified. 58 removal excavated soil to a distance not exceeding 50 m and depositingwhere directed at a level not exceeding 1.5 mabove the starting point complete all as specified & directed. 59 taking down carefully aluminum / copper point wiring on & including hard wood battens, surface conduit and board / blocks etc or through conduits for light , socketor power point , fan point complete incl fitting such as switches , sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials ( other than those for which credit has been given by the contractor ) to the mes stores yard for keeping in safe custody complete all as specified and directed. 60 material and labour forpoint wiring with approved colour code multi stranded copper conductor, pvc insulated and unsheathed frlsh cable of size 1.5 sqmm , 1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, pvc insulated and unsheathed frlsh cable of size 1.5 sqmm , 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed pvc conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofone light / bell / buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. 61 all as per serial item 60 herein before but for socket outlet 3 pin 5 amps on same board complete all as specified and directed 62 all as per serial item 60 herein before but for socket outlet 3 pin 6 amps on independentboard complete all as specified and directed 63 all as per serial item 60 herein before but one socket outlet three pin , 6 / 16 amp, independent board, with 2.5 sqmm ( nominal area ) frlshcable & 2.5 sqmm ( nominal area ) cable as earth continuity conductor 64 switch modular type ( isi marked ) , single pole, one way 6 amps, one module ( isi marked ) , complete all as specified & directed. 65 switch modular type ( isi marked ) , single pole, one way 16 amps, one module ( isi marked ) , complete all as specified & directed. 66 socket shutters outlet 2 / 3 pin 6 amp modular type multi purpose combined two module ( isi marked ) , complete all as specified & directed. 67 socket shutters outlet 2 in 1 pin 6 / 16 amp modular type multi purpose combined 2 module ( isi marked ) , complete all as specified & directed. 68 ceiling rose, pvc or polycarbonate of size 65mmx50mm three terminals ( isi marked ) all as specifiedand directed by engineer in charge. 69 modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. 70 lamp holder, pvc / polycarbonate type with back plate angular type fixed on wall suitable for batten fitting , complete all as specified and directed. 71 led lamp9 watts, b 22 type complete all as specified . 72 disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as dbs, junction box, panels of any size complete with all mccbs , mcbs etcand removing from site, complete all as specified and directed . 73 vertical tpn distribution board double door flush mounting with provisions for mccbs incomer upto 125 to 160amps & outgoing 4 way having ip 43 protection complete all as specified and directed . 74 mccb, 125 amps, four pole, 3 phase , 16ka, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed 75 mcb db, ip 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way spn with 200 amps busbar 240v completed all as specified and directed. 76 single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole mcb 20 amp complete all as specified and directed. 77 mcb, spn , 240 volt, 40 to 63amps, 10 ka , c series including connection with suitable size aluminium / copper lugs complete all as specified and directed 78 mcb , sp , 240 volt, 6amps to 32amps, 10 ka , c series including connection with suitable size aluminium / copper lugs complete all as specified and directed 79 led light fitting 1x9w / 1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable sizefixed as in repair complete all as specified and directed. 80 slim led lights fitting, 4 feet, 1x 20w, 220v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. 81 slim led lights fitting, 2 feet, 1x 10w, 220v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. 82 taking down carefully old copper or aluminium sub main wiring of any nos of wiring and size with earth wire on wooden batten / surface conduit / casing capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. 83 sub main wiring with two singlecore frlsh pvc insulated and unsheathed cable with copper conductor of size 4 sqmm ( nominal area ) , 1100 volt grade ( with approved colour coding as per is ) with and including continuous earth wire of size 4 sqmm pvc insulated and unsheathed frlsh multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughpvc concealed conduit 25mm size ( minimum size ) , cutting chases in walls for pvc concealed conduit and making good the disturbed surfaces by provding by wall putty / pop after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.note : ( i ) for the purpose of measurement, 3 runs ( phase, neutral and earth ) of single core04 sqmm cable shall be considered as 1 running metre. ( ii ) cutting chases and pvc conduit will be measured and paid separtely ( iii ) colour code shall be red for phase, black for neutral and green for earth 84 led secuirty light 30 watt led with lens and water / weather proof powder coated high pressure dia cast housing with ip 66 built in control driver, aluminium reflector, heat resistant toughened clear glass, connector block, surge protection with 20 watt led lamp fixed on ceiling / pole / wall / with fixing arrangement fixed with nuts bolts and 1.5 sqmm 3 core flexible wire from ceiling rose to light fitting , completeall as specified and directed . 85 supplying, installing and commissioning of split type air conditionerwith coolingfunction eer 3.2 of capacity 1.5tr, 03 star rated with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, 03 star rated suitable for wall mounted, single phase, 230 / 250 volt ac including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing finishes after commissioning, pvc pipe medium duty 25 mm dia for draining out condensed water, all as required including necessary electric connections, complete all as specified and directed.note : ( i ) quoted rates shall deem to includ the cost ofdrain pipe, copper tubing of requisite length and 4 sqmm multi standard copper cable, brackets, etc. ( ii ) installation and commissioning to be done through oem / itsauthorised service centre / agency. 86 supply and installed voltage stabilizer automatic digital display type, single phase naturally air cooled indoor type & designed for input variation between 170v to 250 volt with output voltage stabilized at 230 volt + / 2.5% of capacity 4.0 kva complete all as specified and directed. 87 supply and fix exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230v, 50 hz, rpm 1200, copper winding of sweep 300mm, complete all as specified and directed. 88 20 to 25 mm dia, rigid non metallic pvc concealed conduit, isi marked, inclusive of all fittings ( such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends ) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, fixed as in repair complete all as specified and directed . 89 cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar ( 1:3 ) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth complete all as specified and directed . 90 earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of gi wire 4mm dia ( 8 swg ) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore gi light grade ( isi marked ) with funnel and wire mesh, including all necessary excavation and earth work, pcc chamber in plain cement concrete ( 1:3:6 ) type c 1 and pit cover of presast rcc with ms frame etc and all as shown in electrical plate no 3 of mes sch part i ( 2009 ) , complete including dismantling of old earthing, all as specified and directed. note ( s ) : ( i ) rcc pit cover shall be pre cast of rcc ( 1:2:4 ) type b 1, 80mm thick reinforced with xpm not less than 4kg / sqm. ( ii ) pcc chamber shall be constructed 500 mm away from the edge of earth pit. ( iii ) rate shall include earth lead and protection pipe of length 7.5m ( iv ) earth resistance should be less than 3ohm. in case the test results are not found below 3ohm, complete earthing will be redone without any extra cost to govt. ( v ) unit rate including protection pipe and gi wire 4.00mm dia from top to earth plate upto 7.5 meter...

Haryana Tourism Corporation - Haryana

40495350 tender for repair and maintenance of huts and other allied items for surajkund international craft mela 2024 1 [2.b1074] b1074. bleaching powder 2 [23.22.1.10]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 1.10. supply and erection of modular case circuit breaker single pole/4 pole on existing wall/pedestal/panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the engineer in charge of the work. 4 pole mccb 125 to 160 amp, 25 ka 3 [23.22.1.11]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 1.11. supply and erection of modular case circuit breaker single pole/4 pole on existing wall/pedestal/panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the engineer in charge of the work. 4 pole mccb 200 to 250 amp, 25 ka 4 [23.22.1.13]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 1.13. supply and erection of modular case circuit breaker single pole/4 pole on existing wall/pedestal/panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the engineer in charge of the work. 4 pole mccb 600 to 800 amp , 50 ka 5 [23.22.1.9]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 1.9. supply and erection of modular case circuit breaker single pole/4 pole on existing wall/pedestal/panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the engineer in charge of the work. 4 pole mccb 6 amp to 100 amp , 25 ka 6 [23.22.4.11]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 4.11. supply and erection of double door sheet steel enclosure distribution board suitable for mcbs and elcbs etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the engineer in charge of the work. vertical tpn db double door 8 way ( 8 incoming 3phase*8 outgoing) 7 [23.22.4.5]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 4.5. supply and erection of double door sheet steel enclosure distribution board suitable for mcbs and elcbs etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the engineer in charge of the work. tpn db horizontal type double door 4 way ( 8 incoming and 3phase*4 outgoing) 8 [23.22.4.6]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 4.6. supply and erection of double door sheet steel enclosure distribution board suitable for mcbs and elcbs etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the engineer in charge of the work. tpn db horizontal type double door 6 way ( 8 incoming 3phase*6 outgoing) 9 [23.22.5.1]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 5.1. supply and erection of miniature circuit breaker 240/415 v in the existing distribution board including making necessary connections: 6 amp. to 32 amp single pole 10 [23.22.5.4]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 5.4. supply and erection of miniature circuit breaker 240/415 v in the existing distribution board including making necessary connections: 40 amp to 63 amp. double pole 11 [23.22.5.8]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 5.8. supply and erection of miniature circuit breaker 240/415 v in the existing distribution board including making necessary connections: 40 amp to 63 amp. mcbs four pole 12 [23.22.8.5]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 8.5. sitc four pole on load manual change over switch in ss enclosure of following ratings 400 amp 415 volts 13 [23.24.3.11]ms stand, bus bar chamber and panels 3.11. supply and erection of metal clad bus bar chamber made from 1.6 mm thick m.s. sheet and fixing with rag bolts on wall or on existing pedestal/angle iron frame including bonding, detachable top and bottom including painting and necessary connection etc. (aluminium bars). 400 amp 4 bars of 100 cm each (cross section 63 mm x6 mm) chamber over all size 1.10 m x 55 cm x 23 cm 14 [23.24.3.6]ms stand, bus bar chamber and panels 3.6. supply and erection of metal clad bus bar chamber made from 1.6 mm thick m.s. sheet and fixing with rag bolts on wall or on existing pedestal/angle iron frame including bonding, detachable top and bottom including painting and necessary connection etc. (aluminium bars). 200 amp 4 bars of 100 cm each (cross section 38 mm x 6mm) chamber over all size 1.10 m x 45 cm x 18cm 15 [23.27.5]supply and erection of godrej almirah typem.s. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick m.s. sheet covering including shutters with suitable hinges and locking arrangement with godrej type handle including round bars . the top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four nos. holes to discharge the heat produced by the current . the shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . the pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the engineer in charge of the work: 5. m.s. pedestal of size 1200 mm wide ,1500 mm high ,450 mm deep and bottom totally open , duly embeded in cement concrete block of size 1350 mm x 600 mm x 200 mm above ground level , having a base of size 1500 mm x 750 mm x 250 mm below ground level . 0 0 16 [23.4.1.1]copper wiring with modular switches in pvc conduit (surface/recess) 1.1. wiring for light/fan/call bell point with modular type switch/socket and gi box, modular type face plate etc in 1.5 sqmm frls pvc insulated copper conductor cable in 1.6 mm thick pvc conduit pipe. group a 17 [23.4.3.1]copper wiring with modular switches in pvc conduit (surface/recess) 3.1. wiring for light/fan/call bell point in 1.5 sqmm frls pvc insulated copper conductor cable in 1.6 mm thick pvc conduit pipe, without separate control switch group a 18 [23.4.4.1]copper wiring with modular switches in pvc conduit (surface/recess) 4.1. wiring in pvc conduit system for 3 pin 5amp. plug point by using 2 no 1.5 sqmm frls copper wire and 1 no 1.5 sqmm frls copper wire , including providing 1 no 5/6 amp 3/5 pin modular type socket and 1 no 5/6 amp modular type switch required gi box ,modular face plate etc complete as required group a 19 [23.4.5.1]copper wiring with modular switches in pvc conduit (surface/recess) 5.1. wiring in pvc conduit system for 3 pin 15amp. plug point by using 2 no 4 sqmm frls copper wire and 1 no 4 sqmm frls copper wire for earthling , including providing 1 no 15/16 amp 3/6 pin modular socket and 1 no 15/16 amp modular switch required gi box , modular face plate etc complete as required group a 20 [23.5.6.4]copper wiring in existing pvc/ms conduit pipe surface/recessed for electrical points 6.4. wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire pvc insulated copper conductor cable 1100 volts grade in existing ms/pvc conduit etc as required. 1 run of size 6 sqmm(1/2.80mm) 21 [23.5.6.7]copper wiring in existing pvc/ms conduit pipe surface/recessed for electrical points 6.7. wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire pvc insulated copper conductor cable 1100 volts grade in existing ms/pvc conduit etc as required. 2 run of size 2.50 sqmm(1.1.80mm) 22 [23.5.6.8]copper wiring in existing pvc/ms conduit pipe surface/recessed for electrical points 6.8. wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire pvc insulated copper conductor cable 1100 volts grade in existing ms/pvc conduit etc as required. 2 run of size 4 sqmm(1/2.24mm) 23 [23.8.11.1]fitting and accessories 11.1. providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch 24 [23.8.11.3]fitting and accessories 11.3. providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch 25 [23.8.11.4]fitting and accessories 11.4. providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp socket 26 [23.8.11.5]fitting and accessories 11.5. providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin socket 27 [23.8.11.7]fitting and accessories 11.7. providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type fan regulator 2 modules 300 watt 28 [24.1.1]earthing and lightening arrestor 1. earthing with gl earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. 29 [24.1.2]earthing and lightening arrestor 2. extra for using salt and char coal/coke for pipe earth electrode as required. 30 [24.2.2.5]lt cable 2.5. laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.: 300 sqmm to 400 sqmm 3 to 3½ core 31 [24.2.4.1]lt cable 4.1. laying of underground cable in pipe /existing open/closed trench etc as required: 2.5 sq mm to 10 sq mm 2 to 4 core 32 [24.2.4.2]lt cable 4.2. laying of underground cable in pipe /existing open/closed trench etc as required: 16 sq mm to 35 sqmm 2 to 4 core 33 [24.2.4.3]lt cable 4.3. laying of underground cable in pipe /existing open/closed trench etc as required: 50 sq mm to 150 sqmm 2 to 4 core 34 [4.1]clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 35 [5.9]demolishing thatch roofing including mats, bamboo, jaffri etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. ...

Military Engineer Services - Haryana

40426663 tender for repair / maintenance of ht ug / oh network, ht vcbs, rmus, distribution transformers and connected works at sector b area under ge ( utility ) ambala cantt; 1 excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes,for under ground cable / erection of poles, stays etc not exceeding 10 square metre on plan and getting out in soft/loosesoil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and as directed. 2 all as per item no. 1 above but excavation depth exceeding 1.5 metre and not exceeding 3.0 metre. 3 material and labourfor sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cmsdeep after laying the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed.note: punned thickness 18cm shall be measured for payment purposes. 4 supplying and laying un reinforced precast cement concrete cable cover, class hv, type 1, with peak, size 300mm x 180 mm x 40 mm, complete, all as specified and as directed. 5 supply and erecting prestressed concrete pole 11.0 mtr long in true vertical position 152x152 mm at top and 152x260 mm at bottom, class 9, conforming to is 1678 and including marking alternate 05 nos white and black strip 30cm height with two coats ofsynthetic enamel paint includingpreparation of surfaces, upto 1.5 metre above the coping of pole, starting with black strip, including dismantling and taking down of old unserviceable pcc ht pole complete all as specified and as directed. note: excavation, earth work, pcc work, channel, clamps, nuts, bolts etc shall be measured and paid separately. 6 supply and erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 sp 55 (11.0 metres long) conforming to is 1678 and including marking alternate 05 nos white and black strip 30cm height with two coats ofsynthetic enamel paint includingpreparation of surfaces, upto 1.5 metre above the coping of pole, starting with black strip, including dismantling and taking down of old unserviceable steel tubular ht pole complete all as specified and directed. note: excavation and earth wok and pcc for foundation, channel, clamps nuts, bolts to be measured and paid separately. 7 material and labour for plain cement concrete 1:4:8 type d 2 (using 40 mm graded mechanically crushed stone aggregate), as in foundation filling and mass concrete, complete, all as specified and as directed. 8 material and labour for plain cement concrete 1:3:6 type c 2 (using 40 mm graded mechanically crushed stone aggregates) as in fixing of hold fast, coping of pole and strut, bed plates and the like, finishing the surface fair and even, including necessary form work, complete, all as specified and as directed. 9 returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick of any description, complete, all as specified and as directed. 10 removing excavated soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.5m above the starting point, complete, all as specified and as directed. 11 supply and fixing in replacement of gi tubing, 80mm bore, light grade, for cable protection along/on poles/culvert/drainage or under road crossing, complete, all as specified and as directed. 12 supply and fixing in replacement of gi tubing, 100mm bore, light grade, for cable protection along/on poles/culvert/drainage or under road crossing, complete, all as specified and as directed. 13 supply and fixing in replacement of gi tubing, 150mm bore, light grade, for cable protection along/on poles/culvert/drainage or under road crossing, complete, all as specified and as directed. 14 supply and fixing in replacement of danger notice plate 1.60 mm thick of size 25x20 cm, mild steel sheet, vitreous enameled red colour, with letters, figures and conventional skull and bones in signal white colour and fixed with m.s. clamps, bolts and nuts of approved size for ht, complete, all as specified and as directed. 15 supply, installing, testing and commissioning of air break gang operated triple switch (godo) outdoor type, vertical mounting type of capacity 200 amp with drop out fuse consisting 12 insulators, isi marked mechanically operated, mounted on insulator and frame work with operating gi rods and mechanical work from ground level with locking arrangement including godrej pad lock with two keys complete with fuse carrier and ht fuse element having upto 200 amp rating suitable for ht 11 kv 50 hz ac supply including necessary electric connection and dismantling and taking down of old unserviceable god complete all as specified and directed. 16 material and labour in replacement of lightning arrester expulsion type, suitable for 11000 volt, with allfittings, trasmission class,discharge capacity 65 ka including connecting with ht line and dismantling and taking down of old unserviceable lightning arrester complete all as specified and as directed. 17 material and labour for aluminium conductor steel reinforced (acsr)weasel/squirrel conductor from 66 kv sub station and other areas, including fixing, stretching on poles and proper noseling with binding wire to insulator of any size on 11 kv oh line as required at site and dismantling and taking down of old unserviceable acsr conductor complete all as specified directed. 18 takingout old unserviceable earthing material and provision of new earthing complete with galvanisedearth plate electrode 600mm x 600mmx 6mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m belowground level with top edge of the earthplate not less than 1.5m belownormal groundlevel, connected to 4.00 mmwire earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 15mm dia (light grade) and connected to main switch or main control board all as shown in electrical plate no.3 of ssr part i & including necessary excavation and earth work. the rate also include charcoal & salt in alternate layers, 20mm dia gi pipe (light grade) for watering, protection pipe, funnel, wire mesh,rcc cover etc, complete, all as specified or indicated and as directed including testing on completion. 19 taking out old unserviceable earthing material and provision of new earthing complete galvanisedearth plate electrode 600mm x 600mmx 6.00mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m belowground level with top edge of the earthplate not less than 1.5m belownormal groundlevel, connected to 25x4 mm gi strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm dia (light grade) and connected to main switch or main control board all as shown in electrical plate no.3 of ssr part i & including necessary excavation and earth work. the rate also include charcoal & salt in alternate layers, 20mm dia gi pipe (light grade) for watering and 40mm giprotection pipe, funnel, wire mesh,cast iron cover andframe etc, complete, all as specified or indicated and as directed including testing on completion. 20 taking out old unserviceable earthing material and provision of new earthing complete copper plate electrode 600mm x 600mmx 3.15mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m belowground level with top edge of the earthplate not less than 1.5m belownormal groundlevel, connected to 20x3 mm copper strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 32mm dia (medium grade) and connected to main switch or main control board all as shown in electrical plate no.3 of ssr part i & including necessary excavation and earth work. the rate also include charcoal & salt in alternate layers, 20mm dia gi pipe (light grade) for watering and 40mm giprotection pipe, funnel, wire mesh,cast iron cover andframe etc, complete, all as specified or indicated and as directed including testing on completion.notes for item nos 18.00, 19.00 & 20.00 : (i) the quoted rate shall include the cost of earth work, gi pipe for watering, gi protection pipe, funnel, wire wesh, rcc cover, etc. complete. rcc cover shall be 50mm thick in 1:2:4 type b 1 using 8mm bars @10cm c/c both way.(ii) the quoted rate shall include the cost of earth pit covers to be conspicuously marked of plate with stand grouted in pcc.(iii) on testing after completion if the desired earth resistance is more than 2 ohm the earthing will be redone at no extra cost. 21 dismantling and taking down of old unserviceable cross arms, clamps, bracing, etc. of any section from pole including nuts, bolts, washers and cutting of bolts (slag bolts) if required complete and material and labour for new cross arm bracing supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling hole for bolts in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide primer complete, all as specified and as directed. 22 supply and fixing pin type, porcelain,vitreous,white or brown or green insulators,11000 volts grade of 150 mm dia, 150 mm height including one galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nuts and dismantling and taking down of old unserviceable insulators complete all as specified and as directed. 23 supply and fixing disc type insulators, porcelain, vitreous 145 mm height and 255 mm dia ball and socket type, white, brownor green single disc assembly for tension with tension clamps for conductor, working pressure 11000 volts grade,and dismantling and taking down of old unserviceable insulators complete all as specified and as directed. 24 supply and fixing of stay assembly complete with all accessories such as stay plate 300mmx300mmx6mm,stay rod 20 mm dia and 215cm long threaded end with nuts including 14mm dia gistay bow. turn buckle,etc. complete, all as shown in electrical plate no 1 of ssr part i 2009 complete including dismantling and taking down of old unserviceable stay assembly all as specified and as directed. note the quoted rate shall include the cost of loop type insulator, stay clamps, excavation, pcc, stay wire, stay bow, turn buckle, nuts etc., excavation, demolition and removal of demolished concrete outside defence land complete. 25 supply only in replacement of silica gel 4 6 mesh suitable for transformers breather andprotect vcbs, rmus from moisture at66 kv / 11 kv stations complete as per site requirement complete, all as specified and as directed. 26 material and labour for detecting of fault in ug cable with fault locator equipment which is capable to supplyas per cable of (11 kv/430 volts) serviceable to cable complete all as specified and directed.note : (a) the fault which is detected through cable fault locater will only be paid under this item. (b) charges of cable fault locator and dg set including transportation charges deemed to be included in the quoted rate. (c ) earth fault locator will be provided by the contractor for even singlefault and no dealy on this account will be acceptable otherwise penality will levied rs 500/ per day.(d) (d) necessarytesting of cable after making joint will be deemed to be including in the cost of relevent item. however necessary earth work cable cutting, joint making jointwill be paid under relevant item. 27 supply andfixing of self fusing ethylene propylene rubber(epr)based high insulating voltage tape of width not less than 19 mm and thickness not less than 0.75 mm of any length to protectht/lt xlpe cable from moisture and current leakage complete, all as specified and as directed. 28 material and labour for boaring of holes under road, pavement, hard standing of any material and description,by trench less technology using ultra sound technique or manual boringincluding providing hdpe pipe of 80 150mm dia suitable for 0.4 mpa working pressure complete, all as specified and as directed.note: boring depth as decided by engineer in charge.material and labour for augering of hole of suitable dia & providing heavy duty hdpe pipe of size 80 150mm dia in true horizontal drill under existing national highway,road and railway track, buildings comlpete all as directed by engineer in charge.note: (i) the auguring of horizontal hole will be carried out through trenchless horizontal boring machine as shown in site plan.(ii) the cost of hdpe pipe machinery ,transportation,dg set etc included in the rate quoted.(iii) the boring will be carried out upto 03 mtr deep below the railway track ground level and nh 1 a line cost of excavation of working space as both side of trenchless boring will be deemed to be included in the rate quoted. (iv) while carrying out the work below railway track and nh 1 a , the contractor will adhere to instruction issued by the respective authority. the work will be carried out of at such places under the supervision of mes and railway/ highway authirities. (v) any damage of other property like sewage pipes, other cables , water pipes etc will be repaired/replaced under this item without extra cost , department will not responsible of any damage. 29 supplying and laying of xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 95 sqmm 3 core, suitable for 11 kv earthed system confirming to is 7098 part 2 for insulation and for conductors class 2 to is 8130 84, in trenches, floors, ducts passing through pipe forroad crossing etc, including connecting & testing and disconnecting and taking down of old unserviceable ht cable complete all as specified and directed.(note : excavation, earth work, brick protection, sand cushioning and gi pipe etc shall be measured & paid for separately). 30 supplying and laying of xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 120 sqmm 3 core, suitable for 11 kv earthed system confirming to is 7098 part 2 for insulation and for conductors class 2 to is 8130 84, in trenches, floors, ducts passing through pipe forroad crossing etc, including connecting & testing and disconnecting and taking down of old unserviceable ht cable complete all as specified and directed.(note : excavation, earth work, brick protection, sand cushioning and gi pipe etc shall be measured & paid for separately). 31 supplying and laying of xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 185 sqmm 3 core, suitable for 11 kv earthed system confirming to is 7098 part 2 for insulation and for conductors class 2 to is 8130 84, in trenches, floors, ducts passing through pipe forroad crossing etc, including connecting & testing and disconnecting and taking down of old unserviceable ht cable complete all as specified and directed.(note : excavation, earth work, brick protection, sand cushioning and gi pipe etc shall be measured & paid for separately). 32 material and labour for cable jointing kit for 11 kv (earthed) grade cable for straight through heatshrinkable type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 50 sqmm to 95 sqmm incl taking down old unsv ht joint complete all as specified and directed . 33 material and labour for cable jointing kit for 11 kv (earthed) grade cable for straight through heatshrinkable type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 120 sqmm to 185 sqmm incl taking down old unsv ht joint complete all as specified and directed . 34 m&l for cable end termination jointing kit ht 11 kv grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for ht xlpecable 50 95 sqmm 3 core 11 kv grade earthed system incl taking down old unsv ht joint complete all as specified and directed . 35 m&l for cable end termination jointing kit ht 11 kv grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for ht xlpecable 120 185 sqmm 3 core 11 kv grade earthed system incl taking down old unsv ht joint complete all as specified and directed . 36 taking down old unserviciable board and supply and fixing of retro reflective sign board of size 600 x 750 sqmm made of acp sheet of 3mm thick acp sheet shall be fixed on ms frame with legs of ms angle section 40mm x 40mm x 5mm grouted in pcc 1:3:6 type c 1, 750mm above the ground level and 600mm below the ground level. the background of board to be provided with red colour, letters and border with white retro reflective tape. same description shall be mentioned on both sides of acp sheet complete all as specified and directed.note: (i) excavation, earth work, pcc, nuts, bolts, fasners, paint on ms frame and legs shall be included in quoted rates by contractor.(ii) the size of letters and description shall be all as per sample approved by engr in charge. 37 material and labour for cable route indicator showing mes ht ug 11 kv and route of cable with arrow (should be embossed or engraved) made of rcc in suitable shape and fixed in pcc block 1:3:6 type c 2 using 40mm graded aggregate) 60cm xz 30cm in ground, 30cm below ground level and 30cm above ground level to show clear indication of cable including painting the complete slab with red paint and making the engraved/embossed letters/arrows with white paint, complete all as specified and as directed. 38 material and labour for shifting heavy items /excavating /cleaning areas /clearing site by providing crane/hydra/excavators as required at site complete all as specified and as directed. 39 material and labour for for loose filling in substations, under poles, under transformers of hard core broken to gauge not exc 63 mm broken stone/boulders including leveling and spreading lime stone powder under stones complete all as specified and as directed. 40 material and labour for prepration of old concrete surface of ht poles, 11 metres high including pcc coping, removing old paint particles and apply two coats of cement base paint on the surface of pole and pcc coping, applying two coat of aluminium paint on cross arms, bracing, supports, clamps, eye hooks, security light bracket clamp etc and marking black and white strips with synthetic enamel paint, 30 cm wide, alternatively upto 1.5 mtr above the coping of pole starting with black strip complete, all as specified and directed.note.(i)the quoted rate shall include marking of numbers on each ht pole as per direction of engr in charge.(ii)the quoted rates includes the cost of repairing of coping in cement mortar 1:3 finishing surfaces even and smooth without using extra cement. 41 material and labour for prepration of old steel surface of htpoles, 11 metres high including pcc coping, removing old paint particles and apply two coats of synthetic paint on the surface of pole and two coat of cement base paint on surface of pcc coping, applying two coat of aluminium paint on cross arms, bracing, supports, clamps, eye hooks, security light bracket clamp etc and marking black and white strips with synthetic enamel paint, 30 cm wide, alternatively upto 1.5 metre above the copping of pole starting with black strip complete, all as specified and directed.note.(i)the quoted rate shall include marking of numbers on each ht pole as per direction of engr in charge.(ii)the quoted rate include the cost of repairing of coping in cement mortar 1:3 finishing surfaces even and smooth without using extra cement. 42 supplying and laying in replacement of synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 kv forlectrical purpose as per is 15652 2006, (superseding is 5424) suitable for electrical shock safety of sizes 10m x 1m complete all as specified and diercted. 43 calibration of vcbs relay by injecting high voltage through cts checking the over load system of vcb upto 90% rated load and artificial fault creation and setting of relay by 10 to 15% of rated load removing unseviceable overload and earth fault relay including connections with power pack, opening out the trolley, checking the operation of vcb mechanically and electrically through shunt trip coil includng energizing of automatically, checking of tnc switch including testing and commissioning complete all as specified and directed.note : calibration to be carried out by authorised person and test certificate shall be furnished 44 taking out the ht 11 kv metalclad vaccum circuit breaker of capacity 630a/1250 a, 11000 volts,3 ph, 50 hz, 350 mva of any make and type from the cubical panel, for repairs/overhauling and servicing including replacement of wornout parts comprising the following works (a) removing the complete fixed contacts, moving contacts, cleaninig the contacts, removing the fittings and fixing back to the breakers after adjusting the pressure.(b) checking charging motor, motor relay, anti pump relay of the breaker, lubricate and align properly for smooth and perfect operation. (c) check and service the operating mechanism closing mechanism, and tripping mechanism including spring pressure, position etc. the labour charges are deemed to be included in the quoted unit rate for this item.note (i) servicing shall be performed by authorised service personnel of oem i.e m/s abb/seimens. (ii) servicing certficate shall be provided to engineer in charge. (iii) replacement of minor spares like push button lever, green push button, red push buttons and shaft for operating handles etc. are inclusive of rate quoted by tenderer (iv) measurment of resistance value, tools, labour, petroleum jelly are incl in this quoted rates (v) part will be replaced under relevent items. 45 material and labour for highly ht insulating opaque red coloured anti track compound spray 320 of mosil lubicants that forms flexible chemical resistant coating to class h winding for electrical apparatus, in 500 ml spray bottles to protect ht equipments, bus bar, cts, pts from current leakage due to moisture complete all as specified and as directed. 46 material and labour for danment chemical spray (dc>2.26 having container 415ml/300g) for precision blended multipurpose product to protect ht equipments from corrosion due to moisture complete all as specified and as directed.make : danmet chemical pvt ltd or equivalent as specified. 47 material and labour for spraying chemical (roundup) on area to remove unwanted vegitation/ grass at various locations as directed by engr in chargenote : (i)labour and equipments required to spray chemical on required area are included in the quoted rates. (ii)spray shall be repeated quarterly all as per directionof engr in charge 48 supply and fixing in replacement of pole assembly (vacuum interrupter bottle assembly) complete breaker of abb suitable for fixing in sector b substationcomplete all as specified and directed. 49 supply and fixing in replacement of vacuum interrupter pulling rod suitable for abb/siemens suitable breaker for existing model for fixing in 66kv/11kv substations complete all as specified and directed. 50 supply and fixing in replacement of unserviceable spout of vcb panel for suitable model fromht panel abb/seimens of 11 kv substations complete, all as specified and as directed. 51 supply and fixing in replacement of unserviceable spout contant of vcb panel for suitable model fromht panel abb/seimens of 11 kv substations complete, all as specified and as directed. 52 supply and fixing in replacement ofhousing of pole assembly for abb/seimens suitable model breaker from ht panel of 11 kv substations, complete all as specified and directed. 53 supply and fixing in replacementof unserviceable strip heaters 100 watt, ac 240 volts from ht panel of 11 kv substations complete all as specified and directed. 54 supply and fixing in replacement of unserviceable thermostat from ht panel of 11 kv substations complete all as specified and directed. 55 supply and fixing in replacement of unserviceable strip heaters 80 watt from ht panel of 11 kv substations complete all as specified and directed. 56 supply and fixing in replacement of unserviceable indicator with complete wiring of red/green/yellow colour from ht panel of 11 kv substations complete all as specified and as directed. 57 supply and fixing in replacement potential transformer (pt) of rating 11000/110v size and model as suitable for existing pts installed at 11 kv substations including re wiring and testing complete all as specified and directed. 58 supply and fixing in replacement current transformer of rating 500 250/5a of size and model as suitable for existing pts installed at 11 kv sub stations including re wiring and testing complete, all as specified and directed. 59 supply and fixing in replacement current transformer of rating 200 100/5a of size and model as suitable for existing pts installed at 11 kv sub stations including re wiring and testing complete all as specified and directed. 60 supply and fixing in replacement of shunt closing release coil 24 v/110v dc/ac suitable for 12 kv 1250 a 31.5 ka vcbs for suitable model of make abb//seimens/schneidercomplete all as specified and directed. 61 supply and fixing in replacement of geared motor (el)220 250 v ac/dc suitable for 12 kv 1250 a 31.5 ka vcbs for suitable model of make abb//seimens/schneider complete all as specified and directed. 62 supply and fixing in replacement of unserviceable limit switch for spring charging motor for suitable model of make abb//seimens/schneider ht panel of 11 kv substations complete all as specified and as directed. 63 supply and fixing in replacement of tripping coil 24 volt dc suitable for 12 kv 1250 a 31.5 kavcbs for suitable model of make abb//seimens/schneider complete all as specified and directed. 64 supply and fixing in replacement of racking mechanism to restrict uncessary blocking of trolley arrangement for suitable model of abb/siemens breaker complete all as specified and directed. 65 supply and fixing in replacement of tulip contacts 08/12 fingers of circuit breaker for suitable model of abb/siemens circuit breaker complete all as specified and directed. 66 supply and fixing in replacement of tnc switch for vcbs at different 11 kv substations complete all as specified and directed. 67 supply and fixing in repair pt fuse of capacity 11 kv suitable to fit on existing pts in 11 kv incommer vcbs at varioussubstations under ge (u) ambala complete all as specified and directed. 68 supply and fixing in replacement of combined overcurrent and earth fault relay rej601/7sr1205 of make abb/siemens including fixing in ht panels at66 kv mrs and 11 kv substations with connections as per company diagram from oem complete all as specified and as directed. 69 supply and fixing in replacement of master tripping relay of auxillary voltage 24 v/110 v ac/dc of make abb//seimens/schneider including fixing in ht panels at 11 kv substations with connections as per company diagram from oem complete all as specified and as directed. 70 supply and fixing in replacement of supervision relay of make abb/siemens including fixing in ht panels at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed. 71 supply and fixing in replacement ofauxiliarycontact suitable for make abb//seimens incl fixing in ht panels at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed by engr in charge. 72 supply and fixing in replacement ofdigital type ammeter with 1.0 accuracy class (+)1% of full scale 1 count 0 to 300 amps, stranded voltage burden 0.25 va max/phase working on ac auxillary supply voltage 230 volts, sencing ct 5 amps flush mounted type of size 96mm x 96mm x 75mm suitable for make abb//seimens vcbs complete all as specified and directed. 73 supply and fixing in replacement of digital type voltmeter to measure ac voltage 0 to 500 volts with 1.0 accuracy class, stranded voltage burden 0.25 va max/phase working on ac auxillary supply voltage 230 volts,flush mounted type of size 96mm x 96mm x 75mm suitable for make abb//seimens vcbs complete all as specified and directed. 74 supply and fixing in replacement of busbar insulatorin ht panels at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed by engr in charge. make abb//seimens/schneider 75 supply and fixing in replacement pvc unsheathed multi stranded copper cable (fr lsh) 1.5 sqmm nominal cross sectional area 1100 volts conforming to is 694 including electrical connection suitable size of lugs,nuts and bolts in vcbs complete all as specified and directed. 76 supply and fixing in replacement pvc unsheathed multi stranded copper cable (fr lsh) 2.5 sqmm nominal cross sectional area 1100 volts conforming to is 694 including electrical connection suitable size of lugs,nuts and bolts in vcbs complete all as specified and directed. 77 supply and fixing inreplacement copper terminals (thimbles) utype after cutting the worn out/faulty cable end suitable forvcbcontrol wiring 1.5/2.5 sqmmincluding crimping with crimping tools all as specified and directed. 78 supply and fixing inreplacement copper terminals (thimbles) pintype after cutting the worn out/faulty cable end suitable forvcbcontrol wiring 1.5/2.5 sqmmincluding crimping with crimping tools all as specified and directed. 79 supply and fixing inreplacementpower pack with battery backup input230 volt ac and out put 110 volt dc, 1a suitable for existingmake alan model no app 230110 sns invcbs abb/seimens complete allas specified and directed. 80 supply and fixing inreplacementdoor locksuitable for existingmakevcbs abb/seimens complete allas specified and directed. 81 taking down of ht rmu after disconnecting ht supply and reinstalled the same after repairing, servicing and testing of ht rmu and breakers, removing moisture and dust from ht bus bar and from inside of rmu panel of 11 kv substations complete all as specified and directed.note (i) the job shall be carried out through oem only. (ii)mesurement of (ir) resistance value tools, labour, petroleum jelly are included in this quoted rates.(iii) parts will be replaced under relevent items. 82 supply and fixing in replacement of combined over current and earth fault relay of make ashida model no adr141c or equivalent as specifiedincl fixing in rmu make abb at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed by engr in charge. 83 supply and fixing in replacement of pressure guage of rmu complete of make abb incl fixing in ht panels at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed by engr in charge. 84 supply and fixing in replacement of indicator with electric wiring complete of make abb incl fixing in rmu at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed by engr in charge. 85 supply and fixing in replacement of cable boot of make abb incl fixing in rmu at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed by engr in charge. 86 supply and fixing in replacement of bushing with o ring of make abb incl fixing in rmu at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed by engr in charge. 87 supply and filling sf6 gas upto required level by using gas filling adopter including testing after completioncomplete all as specified and as directed. note: necassary filling kit shall be provided by contractor and quoted rates are deemed to be included for the same. 88 supply & fixing in replacement of rmu mechanismsuitable for existing model fo rmu make abbcomplete all as specified and directed. 89 supply and fixing in replacement push button red/green make abb incl fixing in rmu at 11 kv sub stations with connections completeall as specified and directed by engr in charge. 90 supply and fixing in replacement of tripping coil24 v dc suitable for existing rmu make abbcomplete all as specified and directed. 91 supply and fixing in replacement of geared motorsuitablefor existing rmu make abb complete all as specified and directed 92 s & f in replacement of unsv limit switch forgeared motorfor suitableexisting rmu make abbcomplete as per direction of engr in charge. 93 s&f in replacement of current transformer of rating 400 200/1a size and model as suitable as existing rmu of make abb complete all as specified and directed. 94 s&f in replacement of current transformer of rating 200 100/1a size and model as suitable as existing rmu of make abb complete all as specified and directed. 95 disconnecting the ht & lt connections and taking down of existing indoor/outdoor/canopy type transformer of capacity upto 200 kva mounted on 2/4 pole structure/plinth/substation and transport to factory from site/power house/ age e/m yard for repair and back to site/power house/ age e/m yard after necessary repair/replacement of defective parts including installation in the same location and testing, complete, all as specified and directed by engr in charge.note:(a)the rate quoted for the item includes thefollowing : (i)arrangement of manpower, tools , plants , crane and recovery vehicle fortransportation and shifting of transformerto work shop and back. (ii)toping up of transformer oil, replacement of transformer oil as required basis under intimation to the department. (transformer oil will be measured and paid seperately). (iii) re winding of defective winding of transformer, if required will be carried out under this item .(winding material shall be measured and paid separately under respective items) . (b)re winding of transformer and replacement of defective part will be carried out only after inspection of engineer in charge.( rewinding of transformer will be paid separately)(c)any damage occurred to transformer during the process of disconnecting/taking down/transportation, shall be made good by the contractor to the entire satisfaction of the eng in charge at his own expenses. 96 all as per serial item no 95.00 above but for transformer of capacity above 200 kva and upto 1000 kva complete all as specified and directed. 97 supply and fixing in replacement for non metal part hv bushingcomplete with packing for outdoor/indoor/canopy type of transformer of capacity upto 200 kva and for working pressure 11000 volts complete all as specified and as directed by engineer in charge. 98 supply and fixing in replacement for non metal part hv bushingcomplete with packing for outdoor/indoor/canopy type of transformer of capacity exceeding 200 kva but not exceeding 1000 kva and for working pressure 11000 volts complete all as specified and as directed by engineer in charge. 99 supply and fixing in replacement ht, brassbush rodof suitable size for outdoor/indoor/canopy type of transformer of capacity upto 200 kvacomplete all as specified and as directed by engr in charge. 100 supply and fixing in replacement ht, brassbush rodof suitable size for outdoor/indoor/canopy type of transformer of capacity exceeding 200 kva and upto 1000 kva, complete, all as specified and directed by engineer in charge. 101 supply and fixing in replacement for non metal part lv bushingwith packing for outdoor/indoor/canopy type of transformer of capacity upto 200 kva complete all as specified and as directed by engr in charge. 102 supply and fixing in replacement for non metal part lv bushingwith packing for outdoor/indoor/canopy type of transformer of capacity exceeding 200 kva and upto 1000 kva complete all as specified and as directed by engr in charge. 103 supply and fixing in replacement lt bush rod made of brass of suitable size for outdoor/indoor/canopy type of transformer of capacity upto 200 kva complete all as specified and as directed by engr in charge. 104 supply and fixing in replacement lt bush rod made of brass of suitable size for outdoor/indoor/canopy type of transformer of capacity exceeding 200 kva and upto 1000 kva, complete, all as specified and directed by engineer in charge. 105 supply and fixing in replacement top cover gasket of suitable size for outdoor/indoor/canopy type of transformer upto 1000 kva complete all as specified and as directed by engr in charge. 106 dismantling of old burnt tap changer and supply and fixing new tap changing switch as per existing size including making connection to transformer of various capacities/make complete all as specified and as directed by engr in charge. 107 supply and fixing in replacement 100 mm dia, temperature gauge including maximum temperature indicator complete all as specified and as directed by engr in charge. 108 material and labour for preparing surfaces of transformer of capacity up to 200 kva by rubbing old paint and applying two coats of spray painting with grey deco paintfrom outside, complete all as specified and as directed by engr in charge.note.painting of transformer will be carried out for plinth mounted and pole mounted transformer.necessary tools and plants shall be arranged by the contractor. 109 description all as per srl item no 108 hereinbefore but capacity of transformer exceeding 200 kva and upto 1000 kva , complete all as specified and as directed by engr in charge. 110 supply and fixing in replacement of gate valve with drain plug of suitable size for existig transformer, complete all as specified and as directed by engr in charge. 111 supply and fixing in replacement of conservator tank for step down distribution transformers of capacity upto 1000 kvacomplete all as per specification and direction of engr in charge. 112 supply and fixing in replacement of locking arrangement door with handle,hinges and door opennig system including welding, cutting, bending and riveting for compact sub station step down distribution transformers of capacity from 400 kva to 1000 kva complete all as per specification and direction of engr in charge. 113 material and labour forheating, filtration and dehydration of transformer oil as per is : 10028 (part iii) 1981, para 5.2 (obtained from transformer/servo voltage stabilizer switch under repair at workshop) with dehydration/ filtration plant to achieve dielectric strength of 40kv at4 mm gap, complete all as specified and as directed by engr in charge.note: any damage occurred to transformer during the process of dehydration, shall be made good by the contractor to the entire satisfaction of the engr in charge at his own expenses. 114 supply and pouring new transformer oil as per is : 335 (1993)for transformers installed at various site for topping up after dehydration to achieve the di electric strength 60 kv at 4 mm gap and topping up in the transformer under repair in workshop complete all as specified and as directed by engr in charge.note : transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of engr in charge, container shall be deposited by the contractor to the deptt, which will be returned after completion of conract. 115 material and labour for rewinding of hv side of copper wound transformer with super enameled winding wire as per relevant is, copper winding wire as per is : 1180 and and using original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer including taking down of old unserviceable copper winding wire complete all as specified and as directed . 116 material and labour for rewinding of hv side of copper wound transformer with dpc winding wire as per relevant is, copper winding wire as per is : 1180 and and using original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer including taking down of old unserviceable copper winding wire complete all as specified and as directed . 117 material and labour for rewinding of lv side of copper wound transformer with dpc winding stripas per relevant is, copper winding strip as per is : 1180 and using as per original gauge/dataincluding insulating materials such as cotton tape, packingand sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer including taking down of old unserviceable copper winding strip complete all as specified and as directed. 118 material and labour for rewinding of hv side of aluminium wound transformer with super enameled winding wire as per relevant is, aluminium winding wire as per is : 1180 and and using original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for aluminium wound transformer including taking down of old unserviceable aluminium winding wire complete all as specified and as directed . 119 material and labour for rewinding of hv side of aluminium wound transformer with dpc winding wire as per relevant is, aluminium winding wire as per is : 1180 and and using original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for aluminium wound transformer including taking down of old unserviceable aluminium winding wire complete all as specified and as directed . 120 material and labour for rewinding of lv side of aluminium wound transformer with dpc winding stripas per relevant is, aluminium winding strip as per is : 1180 and using as per original gauge/dataincluding insulating materials such as cotton tape, packingand sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for aluminium wound transformer including taking down of old unserviceable aluminium winding strip complete all as specified and as directed. 121 supply and fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity upto 200 kva complete all as per specification and direction of engr in charge. 122 supply and fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity from 200 kva to 1000 kva complete all as per specification and direction of engr in charge. 123 m&l for repairing the god mechanism pipe and handle lever, etc. by way of welding, greasing and including supply and fixing of new male and female contact complete all as specified and directed 124 surface dressing/cleaning of various 11 kv sub stations free from vegetation of any type including trimming of tree branches, bushes, creepers, etc. complete all as specified & directed.note: the frequency of surface dressing shall not be less than 2 months. 125 trimming of tree branches upto 75 mm dia to clear the route of ht/lt over head conductors in switch yards and open joints upto 3m from the 125 conductor including removing the cut branches from site and depositing at places n exc 50m all as directed by engineer in charge. note: (i) one/more tree branches covering 3m shall be considered as one unit. (ii) the frequency of trimming of tree branches shall not be less than 2 months. 126 note: amount of credit ofrs. 233722.50 for retrieved materials is mentioned in schedule of credit page no. 17 & 18 of tender documents in pdf form which will be deducted offline while acceptance of tender. ...

Maharshi Dayanand University - Haryana

40358961 supply installation testing commissioning of modular kitchen equipments including electrical work and construction of faculty house kitchen in mdu, rohtak 10.30.3 ] providing and laying of chequered precast cement concrete tiles 22 mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement: 4 coarse sand ) . 3. dark shade pigment using ordinary cement 2 [ 10.37.1 ] providing and fixing of kota stone slab flooring over 20 mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) : 1. 25 mm thick 3 [ 10.62 ] providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 4 [ 11.12.1 ] 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1. 1:3 ( 1 cement: 3 fine sand ) 5 [ 11.17 ] providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail / screws etc. complete in all respect to the entire satisfaction of engineer in charge 6 [ 11.5.2 ] 12 mm cement plaster of mix : 2. 1:3 ( 1 cement: 3 fine sand ) 7 [ 11.58 ] providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete 8 [ 11.64.1 ] distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. new work ( two or more coats ) over and including water thinnable priming coat with cement primer 9 [ 11.67.1 ] applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 1. water thinnable cement primer 10 [ 12.102.1 ] providing and fixing aluminium handles, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm 11 [ 12.102.2 ] providing and fixing aluminium handles, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 100 mm 12 [ 12.103.2 ] providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. 2. twin rubber stopper 13 [ 12.151 ] providing and fixing fire resistant door frame of section50 x 60 mm on horizontal side and 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick gi sheet ( zinc coating not less than 120gm / m² ) suitable for mounting 120 min fire rated glazed door shutters. the frame shall be filled with mineral wool insulation having density min 96kg / m³ . the frame will have a provision of g.i. anchor fasteners 14 nos. ( 5 each on vertical style and 4 on horizontal style of size m10 x 80 ) suitable for fixing in the opening along with factory made template for ss ball bearing hinges of size 100x89x3mm for fixing of fire rated glazed shutter . the frame shall be finished with a approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per the directions of engineer in charge . ( cost of ss ball bearing hinges is excluded ) . 14 [ 12.21.1 ] providing and fixing factory made shutters of pre laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to is: 12823 grade l type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium `u` type edge beading all round the shutter, including fixing with angle cleat, grip strip, cadmium plated steel screws, including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of engineer in charge ( cost of `u` beading and hinges will be paidseparately ) . 1. 25 mm thick 15 [ 12.88 ] providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight up to 35 kg and door width up to 700 mm ) , with necessary accessories and screws etc. complete. 16 [ 12.98.2 ] providing and fixing aluminium sliding door bolts, isi marked anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) , transparent or dyed to required colour or shade, with nuts and screws etc. complete : 2. 250x16 mm 17 [ 12.99.5 ] providing and fixing aluminium tower bolts, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 5. 100x10 mm 18 [ 13.10.1 ] providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1. 4.0 mm thick glass panes 19 [ 13.21.1 ] supply and fixing windows frames ( chowkhats ) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per is:277 ( base steel as per is 513 ) with zinc of 120 gm / sqm and powder coated with pure polyester powder up to 50 microns ( as per approved colour ) , 3 nos. 100mm butt hinges 2mm thick, 6 nos. 1.2mm thick crca electroplated stiffner, 6 nos. m.s hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets and screws, m.s tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification and entire satisfaction of engineer in charge. 1. door frame of size 80mm x 50mm with 37mm wide single rebate for 35mm door shutter 20 [ 20.71.1 ] supply, erection, testing of ceiling fansis marked ( as per is code 374 ) with suitable gi pipe complete in all respects complete as per directions of engineer in charge 1. 48 ( 1200mm ) 21 [ 22.10.1.1 ] providing and fixing stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is:13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1.1. kitchen sink with drain board 510x1040 mm bowl depth 250 mm 22 [ 22.101.1.1 ] providing and fixing unplasticised pvc connection pipe with brass unions : 1.1. 30 cm length 15 mm nominal bore 23 [ 22.104.1 ] providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 1. 15 mm nominal bore 24 [ 22.108.1 ] providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 1. 15mm nominal bore 25 [ 22.109 ] providing and fixing c.p. brass extension nipple ( size 15mmx50mm ) of approved make and quality as per direction of engineer in charge. 26 [ 22.110.1 ] providing and fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 1. 15 mm nominal bore 27 [ 22.166.3.1 ] providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size ( inside ) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 3.1. 180x150 mm size p type with common burnt clay non modular bricks of class designation 7.5 28 [ 22.179.3.1 ] constructing brick masonry chamber for underground c.i. inspection chamber and bends with bricks in cement mortar 1:4 ( 1 cement : 4 coarse sand ) c.i. cover with frame ( light duty ) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23 kg and weight of frame 15 kg ) , r.c.c. top slab with 1:1.5:3 mix ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) , foundation concrete 1:5:10 fine sand : 10 graded stone aggregate 40 mm nominal size ) , inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) , finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 3.1. inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : with common burnt clay non modular bricks of class designation 7.5 29 [ 22.181 ] providing and placing on terrace ( at all floor levels ) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 30 [ 22.222.2.2 ] providing and fixing in position singel socket swr upvc soil waste or antisyphonage pipes as per is 13592 of e.d.c manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. single socket type b 110mm o / d swr upvc pipe lines laid complete 31 [ 22.86.3 ] providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot and cold water supply, including all cpvc plain and brass threaded fittings, i / c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes and fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 3. 25 mm nominal outer dia pipes 32 [ 22.94.6 ] providing and fixing g.i. union in g.i. pipe including cutting and threading the pipe and making long screws etc. complete ( new work ) : 6. 50 mm nominal bore 33 [ 23.21 ] fixing of led down lighter 7 to 28 watt on ceiling or in false ceiling , including cutting / making hole in ceiling including making connections etc as required 34 [ 23.22.4.7 ] mccb , distribution boards, mcb`s, rccb`s, change over etc. 4.7. supply and erection of double door sheet steel enclosure distribution board suitable for mcbs and elcbs etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the engineer in charge of the work. tpn dbhorizontal type double door 8 way ( 8 incoming 3phase*8 outgoing ) 35 [ 23.22.5.1 ] mccb , distribution boards, mcb`s, rccb`s, change over etc. 5.1. supply and erection of miniature circuit breaker240 / 415 v in the existing distribution board including making necessary connections: 6 amp. to 32 amp single pole 36 [ 23.22.5.8 ] mccb , distribution boards, mcb`s, rccb`s, change over etc. 5.8. supply and erection of miniature circuit breaker240 / 415 v in the existing distribution board including making necessary connections: 40 amp to 63 amp. mcbs four pole 37 [ 23.22.6.5 ] mccb , distribution boards, mcb`s, rccb`s, change over etc. 6.5. supply and erection double pole / four pole residual ( rccb / elcb ) on 240 / 415v, 5hz. ac supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the engineer in charge of the work. fp rccb 30ma sensitivity , 40 a 38 [ 23.22.7 ] mccb , distribution boards, mcb`s, rccb`s, change over etc. 7. supply and erection of blanking sheet in existing distribution board. 39 [ 23.4.1.3 ] copper wiring with modular switches in pvc conduit ( surface / recess ) 1.3. wiring for light / fan / call bell point with modular type switch / socket and gi box, modular type face plate etcin 1.5 sqmm frls pvc insulated copper conductor cable in 1.6 mm thick pvc conduit pipe. group c 40 [ 23.4.3.3 ] copper wiring with modular switches in pvc conduit ( surface / recess ) 3.3. wiring for light / fan / call bell point in 1.5 sqmm frls pvc insulated copper conductor cable in 1.6 mm thick pvc conduit pipe, without separate control switch group c 41 [ 23.4.5.3 ] copper wiring with modular switches in pvc conduit ( surface / recess ) 5.3. wiring in pvc conduit system for 3 pin 15amp. plug point by using 2 no 4 sqmm frls copper wire and 1 no 4 sqmm frls copper wire for earthling , including providing 1 no 15 / 16 amp 3 / 6 pin modular socket and 1 no 15 / 16 amp modular switch required gi box , modular face plate etc complete as required group c 42 [ 23.5.6.2 ] copper wiring in existing pvc / ms conduit pipe surface / recessed for electrical points 6.2. wiring main and sub mains in twosingle core for phase and neutral wire and one single core for earth wire pvc insulated copper conductor cable 1100 volts grade in existing ms / pvc conduit etc as required. 1 run of size 2.50 sqmm ( 1.1.80mm ) 43 [ 23.5.6.3 ] copper wiring in existing pvc / ms conduit pipe surface / recessed for electrical points 6.3. wiring main and sub mains in twosingle core for phase and neutral wire and one single core for earth wire pvc insulated copper conductor cable 1100 volts grade in existing ms / pvc conduit etc as required. 1 run of size 4 sqmm ( 1 / 2.24mm ) 44 [ 23.5.6.5 ] copper wiring in existing pvc / ms conduit pipe surface / recessed for electrical points 6.5. wiring main and sub mains in twosingle core for phase and neutral wire and one single core for earth wire pvc insulated copper conductor cable 1100 volts grade in existing ms / pvc conduit etc as required. 1 run of size 10 sqmm ( 1 / 3.50 mm ) 45 [ 23.7.6.2 ] pvc conduit pipe only ( surface or recessed ) for electrical points 6.2. supply and erection of pvc conduit isi marked ( medium ) recessed in wall / ceiling etc. including the cost of pvc bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of engineer in charge of work. pvc pipe of 25 mm dia. 46 [ 23.7.6.4 ] pvc conduit pipe only ( surface or recessed ) for electrical points 6.4. supply and erection of pvc conduit isi marked ( medium ) recessed in wall / ceiling etc. including the cost of pvc bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of engineer in charge of work. pvc pipe of 40 mm dia. 47 [ 23.8.10.1 ] fitting and accessories 10.1. providing and fixing gi concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 modules including combined plate for telephone and data 48 [ 23.8.10.4 ] fitting and accessories 10.4. providing and fixing gi concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 modules 49 [ 23.8.11.10 ] fitting and accessories 11.10. providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. blanking plate 50 [ 23.8.11.11 ] fitting and accessories 11.11. providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. rj 45 computer data socketoutlet for cat 6 or cat6e cable modular type 51 [ 23.8.11.7 ] fitting and accessories 11.7. providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type fan regulator 2 modules 300 watt 52 [ 23.8.11.8 ] fitting and accessories 11.8. providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. telephone socket outlet modular type 53 [ 23.8.4 ] fitting and accessories 4. supply and erection of 10.5 cm dia m.s.fan box including 8 mm dia 30 cm long m.s. road made into suitable suspension hook and erected in r.c.c. slab for the erection of fan complete with all labour and material required to complete the job. 54 [ 24.1.3 ] earthing and lightening arrestor 3. earthing with g.i. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required. 55 [ 24.1.5 ] earthing and lightening arrestor 5. extra for charcoal or coke and salt for g.i. plate or copper plate earth electrode. 56 [ 24.1.6 ] earthing and lightening arrestor 6. supplying and laying 25mm x 3mm g.i. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required. 57 [ 24.2.4.1 ] lt cable 4.1. laying of underground cable in pipe / existing open / closed trench etc as required: 2.5 sq mm to 10 sq mm 2 to 4 core 58 [ 24.2.4.2 ] lt cable 4.2. laying of underground cable in pipe / existing open / closed trench etc as required: 16 sq mm to 35 sqmm 2 to 4 core 59 [ 25.3.7 ] supplying, fixing, testing and commissioning of butterfly valves pn 16 rated without insulationforwater circulation as per specifications. 7. 80mm dia. 60 [ 28.16 ] providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: ( a ) after surface preparation, first layer of slurry of cement @ 0.488 kg / sqm mixed with water proofing cement compound @ 0.253 kg / sqm ( b ) laying second layer of fibre glass cloth when the first layer is still green. overlaps of joints of fibre cloth should not be less than 10 cm. ( c ) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg / sqm mixed with water proofing cement compound @ 0.670 kg / sqm and coarse sand @ 1.289 kg / sqm this will be allowed to air cure for 4 hours followed by water curing for 48 hours. the entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around. ( d ) fourth and final layer of brick tiling with cement mortar ( which will be paid for separately ) .for the purpose of measurement the entire treated surface will be measured. 61 [ 30.82.2 ] making holes by cutting cores of appropriate dia in rcc floors and roofs of thickness up to 6` ( six inches ) for passing drain pipe and repairing the hole after insertion of drain pipe etc. including finishing complete so as to make it leak proof. 2. drain pipe of 100mm internal dia 62 [ 4.32 ] filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 63 [ 4.8.1 ] earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead up to 50 m and lift up to 1.5 m : 1. all kinds of soil 64 [ 6.1.6 ] providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work below plinth level and up to floor iv level: 6. 1:4:8 ( 1 cement : 4 coarse sand ( zone iii ) : 8 graded stone aggregate 40 mm nominal size ) 65 [ 6.16 ] reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand ( zone iii ) : 3 graded stone aggregate 20 mm nominal size ) . 66 [ 6.30.1 ] centering and shuttering including strutting, propping etc. and removal of form for 1. foundations, footings, bases of columns, etc. for mass concrete 67 [ 6.30.3 ] centering and shuttering including strutting, propping etc. and removal of form for 3. suspended floors, roofs, landings, balconies and access platform 68 [ 6.30.5 ] centering and shuttering including strutting, propping etc. and removal of form for 5. lintels, beams, plinth beams, girders, bressumers and cantilevers 69 [ 6.33.6 ] steel reinforcement for r.c.c. work, where not included in the complete rate of rcc, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level 6. thermo mechanically treated bars of grade fe 500d or more. 70 [ 6.9.2 ] providing and laying damp proof course with cement concrete 1:1.5:3 ( 1 cement : 1.5 coarse sand ( zone iii ) : 3 graded stone aggregate 20mm nominal size ) 2. 40 mm thick 71 [ 7.20.1 ] brick work with common burnt clay modular bricks of class designation 10.5 in foundation and plinth in: 1. cement mortar 1:4 ( 1 cement : 4 coarse sand ) 72 [ 7.23.1 ] brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to is: 2222 in superstructure above plinth level up to floor four level in cement mortar 1:6 ( 1 cement : 6 coarse sand ) : 1. with non modular bricks 73 [ 7.26 ] brick work 7 cm thick with common burnt clay non modular brick of class designation 10.5 in cement mortar 1:3 ( 1 cement : 3 coarse sand ) in superstructure above plinth level and up to floor four level. 74 [ 7.57 ] dressed or moulded two brick cornice laid in cement sand mortar 1:4 including 12 mm thick cement plaster 1:4 or pointing, as required. 75 [ 8.26.2.2 ] providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand ) , joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. granite of any colour and shadearea of slab over 0.50 sqm 76 [ 8.29 ] mirror polishing on marble work / granite work / stone work where ever required to give high gloss finish complete. 77 [ 9.10.1 ] painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 1. with residual type petroleum bitumen of grade vg 10 78 [ 9.11.1 ] 10 cm thick ( average ) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 ( 1 clay : 1 cow dung ) and covered with flat tile bricks, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand ) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. with common burnt clay non modular brick tile of class designation 10 79 [ 9.17.1 ] providing gola 75x75 mm in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge ) , including finishing with cement mortar 1:3 ( 1 cement : 3 fine sand ) as per standard design : 1. in 75x75 mm deep chase 80 [ 9.18 ] making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size ) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 81 [ 9.46.3 ] providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from m.s. sheets and galvanized with zinc coating of 120 gms / sqm ( both side inclusive ) as per is : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate g.i. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to g.i. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c / c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the engineer in charge but excluding the cost of painting with : 3. 12.5 mm thick tapered edge gypsum moisture resistant board 82 [ 9.57.2 ] providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, ( i ) single socketed pipes. 2. 110 mm diameter 83 [ 9.58.5.2 ] providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 5.2. bend 87.5°110 mm bend 84 [ 9.62.1 ] providing and fixing m.s. holder bat clamps of approved design to c.i. or s.c.i. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) and cost of cutting holes and making good the walls etc. : 1. 100 mm diameter 85 p / f multy trap of self cleaning design 100*75mm supreme / finolex / prince make 86 p / f cast brass cleanout plug 100 mm dia isi heavy duty 87 providing and fixing waste coupling cp brass 32mm dia ( jaquar / essco / cera make ) complete in all resect to the entire satisfaction of engineer in charge. 88 providing and fixing bottle trap cp brass 32mm dia ( jaquar / essco / cera make ) complete in all resect to the entire satisfaction of engineer in charge. 89 providing and fixing grating 100mm size ( chilly / highlife / camry make ) complete in all resect to the entire satisfaction of engineer in charge. 90 providing and fixing ball valve cp brass 50mm dia with plastic float and brass rod of required length ( hb / drp / zoloto make ) complete in all resect to the entire satisfaction of engineer in charge. 91 providing and fixing g.m. float valve with copper ball float and brass rod of required length 40mm dia ( hb / drp / zoloto make ) complete in all resect to the entire satisfaction of engineer in charge. 92 supply and erection of recessed mounting 24 w circular energy efficient led light fitting with pressure die cast aluminium heat sink and pc diffuse in white powder coated finish with integrated driver. working hours minimum 50000 hours operation on single phase ac supply complete in all respect upto the entire satisfaction of engineer in charge of the work including making necessary connections etc. make: havells, bajaj, philips. 93 supply and erection of 400 mm dia wall fan complete in all repects complete as per directions of engineer in charge. make: havells, bajaj, orient / crompton. 94 supply of 16 sq mm 4core copper wire make: havells, anchor, rr kabel / polycab 95 supply of 6 sq mm 2 core copper wire make: havels, anchor, rr kabel / polycab 96 supply and erection of low height cooking range.frame ( frame work of m.s.anlge duly painted, mounted on s.steel tubular legs with adjustable feet. top and sides and under shelf of s.s.sheet. hy pressure gas burners with individual control valves. cast iron pan support. ) w=30, d=30, h=30 complete in all respect as per site requirement and as per entire satisfaction of engineer in charge of the work make: godrej / durian / livspace / urbangrey 97 supply and erection of three burner indian range.frame work of m.s.anlge duly painted, mounted on s.steel tubular legs with adjustable feet. top and sides and under shelf of s.s.sheet. the range will be complete. hy pressure gas burners with individual control valveswith three burners.. cast iron pan support.w=72, d=30, h=34 plus 6, complete in all respect as per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 98 supply and erection of idli steamermaterial stainless steel, with hinged door.capacity 108 idlis power ( wattage ) 3 kw provided with 12 nos. trays with 9 pockets in each tray ( 108 idli ) , complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 99 supply and erection of bulk cooker tilting type. frying pan of rectangular shaped, ss body with insulation, 10”depth and a pouring lip and the unit will be fitted with v type high pressure gas burner with control valve and pilot lamp. tilting mechanism and counter weight lid. ( 120litre ) complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 100 supply and erection of bulk fryer.triple jacketed body of stainless steel sheet, inner most jacketed of 16g thick with 12g thick dish ended bottom, second wall for air gap of 18g stainless steel sheet and outer insulation jacket also of 18g stainless steel sheet. the unit will have counter weight lid and tilting mechanism ( 50ltr ) complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work.make: godrej / durian / livspace / urbangrey 101 supply and erection of working table with 2 under shelf. frame work made of s.s.anlge top will have p.p. / nylon board for chopping. size of chopping board w=48, d=30, h=34 plus 6, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 102 supply and erection of working table with two sink unit top of 16g s.s.sheet, will have mounted on m.s. angle and ss tubular legs with adjustable feet and two top sink bowl of ss sheet. sink bowl size 18x18x12` on m.s. angle and ss tubular legs frame work. w=72, d=30, h=34 plus 6, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 103 supply and erection of veg cutting machinealuminium casted body with ½ hp electric motor safety switch and double feed pusher for round flat and vertical shaped food items etc., the unit will be table top model with easy to clean provision. provided with 4 no cutting discs for slicing grating dicing, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 104 supply and erection of pulverizer machinestainless steel sheet body, 20g thick. the unit will have a top feeding tray and a housing of stainless steel casting with grinding plates and 3 type of meshes for variable type of grinding requirements. the unit will be fitted with 1.5hp single phase electric. 1.5hp, 3ph, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work.make: godrej / durian / livspace / urbangrey 105 supply and erection of potato peelermotor power 1.0 hp.capacity 10 kg / 5 minutes.input voltage 240.single phase. ss body with inside peeling chamber having abrasive lining on m.s. angle frame work. capacity 10kgs, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 106 supply and erection of wet grindermaterial ss stainless steel 304, phase single phase motorcapacity 1 hp, voltage 230 volts, number of phase single, frequency 50 hz, rotation speed 1440 rpm , material grade ss 304, weight 150, features granite quality stones, cap.10 ltr, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 107 supply and erection of low height table top of 16g s.s.sheet, will have mounted on m.s. angle and ss tubular legs with adjustable feet. w=45, d=24, h=24, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 108 supply and erection of chappti rolling table top of 16g s.s.sheet, will have mounted on m.s. angle and ss tubular legs with adjustable feet with one bottom shelf. w=48, d=30, h=34 plus 6, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 109 supply and erection of chappti plate with pufferframe work of m.s.anlge, mounted on s.s.tubular legs frame work. all sides pannels and undershelf of s.s.sheet, top plate 10mm thick mild steel with cast iron puffing grills for puffing of chappaties. complete with `v` shape lpg burners with individual cont. w=48, d=30, h=34 plus 6, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 110 supply and erection of chappti collection tabletop 4` height tray and undershelf of s.s.sheet on s.s.tubular legs, with adjustable feet. w=18, d=30, h=34, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 111 supply and erection of working table with 2 under shelftop of 16g s.s.sheet, will have mounted on m.s. angle and ss tubular legs with adjustable feet and under shelves.w=24, d=30, h=34 plus 6, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work.make: godrej / durian / livspace / urbangrey 112 supply and erection of griddle plateframe work of m.s. angle top plate of 12mm thick mild steel all sides upto control pannel of ss sheet with one bottom shelf of ss sheet. complete with gas burner pilot lamp and control valve. w=24, d=30, h=34 plus 6, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 113 supply and erection of s.s exhaust hood ( without ducting , hanging and fans ) made of s.steel sheet, 22g thick duly welded and pop rivetted as required. the hood will be complete with s.s.sheet removable type baffle filters. complete with greese collection channel and greese collection cup / s. w=60, d=36, h=18, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 114 supply and erection of dough kneaderss sheet mixing bowl and kneading arm on mild steel / cast iron painted body with 2hp / 3ph electric motor 25 ltr, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 115 supply and erection of working table with 2 under shelftop of 16g s.s.sheet, will have mounted on m.s. angle and ss tubular legs with adjustable feet and under shelves.w=72, d=24, h=34 plus 6, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work.make: godrej / durian / livspace / urbangrey 116 supply and erection of 4 door chillerdouble walled `puf` insulated s.s.sheet outer and inner body of s.s.sheet 0.8mm thick having hinged doors with rubber gascuts with four doors. inside s.s.wire shelves on adjustable channel frame complete. having condensor.w=48, d=30, h=72, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: emmerson / tecumseh / carrier, or eqvl. compressor. 117 supply and erection of working table with 2 under shelftop of 16g s.s.sheet, will have mounted on m.s. angle and ss tubular legs with adjustable feet and under shelves. w=45, d=24, h=34 plus 6, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work.make: godrej / durian / livspace / urbangrey 118 supply and erection of water cooler ss body or eqvl. 150 ltr, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: bluestar / nirvana / volts / cellfrost 119 supply and erection of single sink unittop sink bowl of ss sheet. sink bowl size 18x18x12` on m.s. angle and ss tublur legs frame work. w=24, d=24, h=34 plus 6, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 120 supply and erection of 3 door under counter chillerdouble walled `puf` insulated s.s.sheet outer and inner body of s.s.sheet 0.8mm thick having hinged doors with rubber gascuts with three doors. inside s.s.wire shelves on adjustable channel frame complete withhaving condensorw=72, d=30, h=34, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: emmerson / tecumseh / carrier, or eqvl. compressor. 121 supply and erection of sandwich girllerstainless steel body with cast iron grooved plates with heating elements on each plates. total 3kw load. top plate counter balanced. complete with automatic temp. controller. cap. jumbo, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 122 supply and erection of microwave oven cap. 20 ltr, complete in all respect as per entire satisfaction of engineer in charge of the work. make: ifb or any equl. model. 123 supply and erection of working table with 2 under shelf top of 16g s.s.sheet, will have mounted on m.s. angle and ss tubular legs with adjustable feet and under shelves w=54, d=24, h=34 plus 6, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 124 supply and erection of blender multi function, wet and dry application model no. tm 800a 1.5 litre bpa free polycarbonate blending jar variable speed with one touch auto timer premium quality, transparent, virtually unbreakable container– industrial high speed motor, real 3hp super power–two in one stainless steel cutting blade crushing ice in seconds, precision technology jtc, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 125 supply and erection of fryertable top model, ss body with 6 ltr capacity, frying pan removable type with lid. complete with ss frying basket 2.5 kw heating element with automatic temp. controller. cap. 6 ltrs, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 126 supply and erection of visi coolercapacity 400 ltr , temperature range 1 10 deg c.type. upright chiller with lock.complete in all respect as per entire satisfaction of engineer in charge of the work.make: cellfrost / elanpro / western / voltas / nirvana. 127 supply and erection of hot bain marietop of 16g s.s.sheet, bain marie water tank of 18g s.s.sheet, fitted with 3.0 kw heating element with automatic temperature controller. water outlet provision with drain valve, 3 sides covered with 20g s.s.sheet, top to accommodate s.s.sheet four food pans with gn pan 1x1x6` depth with lids. w=60, d=27, h=34 plus 12, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 128 supply and erection of cold bain mairesame as above but without heating element, ambient temp. working. w=60, d=27, h=34 plus 12, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 129 supply and erection of pickup counter with 2 ohs top of ss sheet with three side covered one bottom and one middle shelf and two nos. over head shelf 12` wide fitted with ss pipe verticals w=60, d=24, h=34 plus 12, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work.make: godrej / durian / livspace / urbangrey 130 supply and erection of s.s rack 5 tier five nos. ss sheet shelves, welded with ss tubler vertical with adjustable feet.w=24, d=27, h=72, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 131 supply and erection of s.s rack 5 tierfive nos. ss sheet shelves, welded with ss tubler vertical with adjustable feet.w=36, d=18, h=72, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 132 supply and erection of dish landing table with garbage chutess sheet top with marine edge all around and a garbage chute on m.s. angle and ss tublur legs frame work. w=60, d=24, h=34 plus 6, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 133 supply and erection of two sink unitsame as above but with two sink bowl. w=48, d=24, h=34 plus 6, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work.make: godrej / durian / livspace / urbangrey 134 supply and erection of working table with 2 under shelf top of 16g s.s.sheet, will have mounted on m.s. angle and sstubular legs with adjustable feet and under shelves. w=30, d=24, h=34 plus 6, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 135 supply and erection of pick up counter with 2 ohs top of ss sheet with three side covered one bottom and one middle shelf and two nos. over head shelf 12` wide fitted with ss pipe verticals w=60, d=30, h=34 plus 12, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 136 supply and erection of s.s exhaust hood ( without ducting , hanging and fans ) made of s.steel sheet, 22g thick duly welded and pop rivetted as required. the hood will be complete with s.s.sheet removable type baffle filters. complete with greese collection channel and greese collection cup / s.w=72, d=36, h=18, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 137 supply and erection of s.s exhaust hood ( without ducting , hanging and fans ) made of s.steel sheet, 22g thick duly welded and pop rivetted as required. the hood will be complete with s.s.sheet removable type baffle filters. complete with greese collection channel and greese collection cup / s. w=48, d=36, h=18, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work.make: godrej / durian / livspace / urbangrey 138 supply and erection of deep freezer 400 ltrscomplete in all respect as per entire satisfaction of engineer in charge of the work. makes: blue star / voltas / godrej ) 139 supply and erection of s.s rack 5 tier five nos. ss sheet shelves, welded with ss tubler vertical with adjustable feet. w=48, d=18, h=72, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 140 supply and erection of bins made of ss sheet with lid mounted on wheels. w=24, d=24, h=24, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work.make: godrej / durian / livspace / urbangrey 141 supply and erection of cold room external room dimensions : 3600x3000mmchiller room temperature ( plus2°c to 8 °c ) , product entering temp plus30°c , pull down time 15hrs., product loading app.550kg. / 24hrs., wall and ceiling panels insulation 80mm thick prefabricated rpuf panels floor panel insulation 80mm thick rpuf panels with layer of tarfelt sheet on both sides. , panel finish internal :pcgi , external: pcgi, refrigerant r 22, no. of units 1connected load 2.5 kw size: 10`x10``x10`x5`, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work.make: emmerson / tecumseh / carrier, or eqvl. 142 supply and erection of cold room rack vertical of 32 mm dia stainless steel pipe with adjustable feet 4 no of 18 s.s wire shelves at equaly distance.w=48, d=18, h=72, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 143 supply and erection of hood fixing ducting exhaust fans and fresh air supply and lpg line as per required layout of drawing work 1. exhaust hoods fixing and ducting for hoods: made of gi sheets as per site conditions duly fabricated.2. axial fans for extraction of smoke etc. 500 mm dia. 1.5 hp 3 ph. electricalmotor housed in a ms sheet enclosure. qty 3 nos.3. air washer unit for fresh cool air. double skin gi powder coated bodycomplete with honeycomb cellulose cooling pads. s s water tank. 5.0 hp 3ph motor and 0.5 hp water pump.4. ducting for fresh air fabricated out of gi sheet with leak proof joints.5. diffuser grills made of by gauge aluminum extruded section duly powdercoated. qty 12 pcs, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work. make: godrej / durian / livspace / urbangrey 144 supply and erection of working table with 2 under shelftop of 16g s.s.sheet, will have mounted on m.s. angle and ss tubular legs with adjustable feet and under shelves. w=60, d=30, h=34 plus 6, complete in all respectas per site requirement and as per entire satisfaction of engineer in charge of the work.make: godrej / durian / livspace / urbangrey...

Military Engineer Services - Haryana

40206764 repair and maintenance of internal electrification with fittingand fixture in md accn of sector ‘a’ and pine marg in aor of age b / r i at chandimandir; 1 taking down carefully aluminum / copper point wiring on & including hard wood battens, surface conduit and board / blocks etc or through conduits for light , socketor power point , fan point complete incl fitting such as switches , sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials ( other than those for which credit has been given by the contractor ) to the mes stores yard for keeping in safe custody complete 2 point wiring with approved colour code multi stranded copper conductor, pvc insulated and unsheathed frlsh cable of size 1.5 sqmm , 1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, pvc insulated and unsheathed frlsh cable of size 1.5 sqmm , 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofone light / bell / buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. 3 all as per serial item 02 herein before but for socket outlet 3 pin 5 amps on same board complete all as specified and directed 4 all as per serial item 02 herein before but for socket outlet 3 pin 6 amps on independentboard complete all as specified and directed 5 all as per serial item 02 herein before but one socket outlet three pin , 6 / 16 amp, independent board, with 2.5 sqmm ( nominal area ) frlshcable & 2.5 sqmm ( nominal area ) cable as earth continuity conductor 6 material and labour forpoint wiring with approved colour code multi stranded copper conductor, pvc insulated and unsheathed frlsh cable of size 1.5 sqmm , 1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, pvc insulated and unsheathed frlsh cable of size 1.5 sqmm , 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed pvc conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofone light / bell / buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. 7 all as per serial item 06 herein before but for socket outlet 3 pin 5 amps on same board complete all as specified and directed 8 all as per serial item 06 herein before but for socket outlet 3 pin 6 amps on independentboard complete all as specified and directed 9 all as per serial item 06 herein before but one socket outlet three pin , 6 / 16 amp, independent board, with 2.5 sqmm ( nominal area ) frlshcable & 2.5 sqmm ( nominal area ) cable as earth continuity conductor 10 switch modular type ( isi marked ) , single pole, one way 6 amps, one module ( isi marked ) , complete all as specified & directed. 11 switch modular type ( isi marked ) , single pole, one way 16 amps, one module ( isi marked ) , complete all as specified & directed. 12 socket shutters outlet 2 / 3 pin 6 amp modular type multi purpose two module ( isi marked ) , complete all as specified & directed. 13 socket shutters outlet 2 in 1 pin 6 / 16 amp modular type multi purpose combined 2 module ( isi marked ) , complete all as specified & directed. 14 modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. 15 modular switch type bell push, single pole, 230 volt one module, ( isi marked ) complete all as specified and directed. 16 switch piano, flush type, 6 amps, 230 volts, single pole, one way ( isi marked ) complete all as directed by engineer in charge 17 switch piano, flush type, 16 amps, 230 volts, single pole, one way ( isi marked ) complete all as directed by engineer in charge 18 sockets outlet multipurpose 2 in 1 pin, 6 and 6amps flush type isi marked all as specifiedand directed by engineer in charge 19 sockets outlet multipurpose 2 in 1 pin, 6 and 16amps flush type isi marked all as specifiedand directed by engineer in charge 20 stepped type electronic fan regulator flush type complete all as specfied and directed. 21 electric bell, ding dong, ac, 230 volts, single pole all as specified and directed by engineer in charge. 22 bell push, paino type, 6 amps, 230 volts, single pole, complete all as directed by engineer in charge 23 ceiling rose, pvc or polycarbonate of size 65mmx50mm three terminals ( isi marked ) all as specifiedand directed by engineer in charge. 24 lamp holder, pvc / polycarbonate type with back plate angular type fixed on wall suitable for batten fitting , complete all as specified and directed. 25 led lamp9 watts, b 22 type complete all as specified . 26 led light fitting 1x9w / 1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable sizefixed as in repair complete all as specified and directed. 27 slim led lights fitting, 4 feet, 1x 20w, 220v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. 28 slim led lights fitting, 2 feet, 1x 10w, 220v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. 29 taking down carefully old copper or aluminium sub main wiring of any nos of wiring and size with earth wire on wooden batten / surface conduit / casing capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. 30 sub main wiring with two singlecore frlsh pvc insulated and unsheathed cable with copper conductor of size 4 sqmm ( nominal area ) , 1100 volt grade ( with approved colour coding as per is ) with and including continuous earth wire of size 4 sqmm pvc insulated and unsheathed frlsh multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughpvc concealed conduit 25mm size ( minimum size ) , cutting chases in walls for pvc concealed conduit and making good the disturbed surfacesby providing by wall putty / pop after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. 31 sub main wiring with two singlecore frlsh pvc insulated and unsheathed cable with copper conductor of size 6 sqmm ( nominal area ) , 1100 volt grade ( with approved colour coding as per is ) with and including continuous earth wire of size 6 sqmm pvc insulated and unsheathed frlsh multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughpvc concealed conduit 25mm size ( minimum size ) , cutting chases in walls for pvc concealed conduit and making good the disturbed surfacesby providing by wall putty / pop after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. 32 supply and fixing sub main wiring with two singlecore frlsh pvc insulated and unsheathed cable with copper conductor of size 10 sqmm ( nominal area ) , 1100 volt grade ( with approved colour coding as per is ) with and including continuous earth wire of size 10 sqmm pvc insulated and unsheathed frlsh multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughpvc concealed conduit 25mm size ( minimum size ) , cutting chases in walls for pvc concealed conduit and making good the disturbed surfacesby providing by wall putty / pop after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.note for serial item no 30, 31 & 32 : ( i ) for the purpose of measurement, 2 single core of 10 sqmm and one single core earth cable of 10 sqmm cableshall be considered as 1 running metre. ( ii ) pvc conduit and cutting chases will be measured and paid separtely ( iii ) colour code shall be red for phase, black for neutral and green for earth 33 supply and fixing sub main wiring with four singlecore frlsh pvc insulated and unsheathed cable with copper conductor of size 10 sqmm ( nominal area ) , 1100 volt grade ( with approved colour coding as per is ) with and including continuous earth wire of size 10 sqmm pvc insulated and unsheathed frlsh multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughpvc concealed conduit 25mm size ( minimum size ) , cutting chases in walls for pvc concealed conduit and making good the disturbed surfacesby providing by wall putty / pop after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.note : ( i ) for the purpose of measurement, 4 single core of 10 sqmm and one single core earth cable of 10 sqmm cableshall be considered as 1 running metre. ( ii ) pvc conduit and cutting chases will be measured and paid separtely ( iii ) colour code shall be red for phase, black for neutral and green for earth 34 cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar ( 1:3 ) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth complete all as specified and directed . 35 disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as dbs, junction box, panels of any size complete with all mccbs , mcbs etcand removing from site, complete all as specified and directed . 36 mccb, 125 amps, four pole, 3 phase , 16ka, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed 37 vertical tpn distribution board double door flush mounting with provisions for mccbs incomer upto 100 to 125amps & outgoing 4 way having ip 43 protection complete all as specified and directed . 38 tpn distribution board double door flush mounting with provisions for mcb tpn 6 way having ip 43 protection complete all as specified and directed . 39 mcb db, ip 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 12 way spn with 200 amps busbar 240v completed all as specified and directed. 40 mcb db, ip 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way spn with 200 amps busbar 240v completed all as specified and directed. 41 mcb db, ip 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 04 way spn with 200 amps busbar 240v completed all as specified and directed. 42 sheet metal enclosure for db, flush mountedsingle door suitable for 2 way spnwithout busbar 240v completed all as specified and directed. 43 mcb, spn , 240 volt, 32amps, 10 ka , c series including connection with suitable size aluminium / copper lugs complete all as specified and directed 44 mcb, spn , 240 volt, 40 to 63amps, 10 ka , c series including connection with suitable size aluminium / copper lugs complete all as specified and directed 45 mcb , sp , 240 volt, 6amps to 32amps, 10 ka , c series including connection with suitable size aluminium / copper lugs complete all as specified and directed 46 mcb , tpn / fp 40 to 100 amp 415 volts, 10 ka , c series including connection with suitable size aluminium / copper lugs complete all as specified and directed 47 earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of gi wire 4mm dia ( 8 swg ) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore gi light grade ( isi marked ) with funnel and wire mesh, including all necessary excavation and earth work, pcc chamber in plain cement concrete ( 1:3:6 ) type c 1 and pit cover of presast rcc with ms frame etc and all as shown in electrical plate no 3 of mes sch part i ( 2009 ) , complete including dismantling of old earthing, all as specified and directed. note ( s ) : ( i ) rcc pit cover shall be pre cast of rcc ( 1:2:4 ) type b 1, 80mm thick reinforced with xpm not less than 4kg / sqm. ( ii ) pcc chamber shall be constructed 500 mm away from the edge of earth pit. ( iii ) rate shall include earth lead and protection pipe of length 7.5m ( iv ) earth resistance should be less than 3ohm. in case the test results are not found below 3ohm, complete earthing will be redone without any extra cost to govt. ( v ) unit rate including protection pipe and gi wire 4.00mm dia from top to earth plate upto 7.5 meter 48 earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including galvanised iron strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore gi light grade ( isi marked ) with funnel and wire mesh, including all necessary excavation and earth work, pcc chamber in plain cement concrete ( 1:3:6 ) type c 1 and pit cover of presast rcc with ms frame etc and all as shown in electrical plate no 3 of mes sch part i ( 2009 ) , complete including dismantling of old earthing, all as specified and directed. note ( s ) : ( i ) rcc pit cover shall be pre cast of rcc ( 1:2:4 ) type b 1, 80mm thick reinforced with xpm not less than 4kg / sqm. ( ii ) pcc chamber shall be constructed 500 mm away from the edge of earth pit. ( iii ) rate shall include earth lead and protection pipe of length 7.5m ( iv ) earth resistance should be less than 3ohm. in case the test results are not found below 3ohm, complete earthing will be redone without any extra cost to govt. ( v ) unit rate including protection pipe and gi strip 32x 6mm from top to earth plate upto 7.5 meter 49 fabrication, install, testing and commission of wall mounted sheet metal busbar chamber cpri approved, grouted with nut and bolts ( with proper locking arrangement and holes to distribute circuits ) of size 600x500x300mm with copper strip 40mm x 6mm ( 04 nos ) of length 450mm with approved colour coded and pvc adhesive coated, ip 54 as per is 13947 protection fixed on insulator with the help of nut / bolts including provison of 10 nos 08 mm dia hole with 8 mm dia 50 mm long nut / bolts with 02 nos of washer connected with 16 sqmm single core colour coding stranded copper cable with thimble / lugs including one mccb, 125 amps, four pole 3 phase 25 ka, 415 volt with adjustable thermal and megnetic release complete having adjustable type base frame and equal space around mccb as incommer one no, making good distrubed surfaces to match with original all as specifed and directednote: contractor will submit drawing of this panel to engr in charge for approval. 50 led street light fitting 35 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with ip 66 protection complete all as specified and directed. 51 fixing only exhaust fan in repair and connecting up to and including provision of 2 core single flexible cable for ceiling rose / connector to fan including clean of blade / body cover etc complete all as specified and directed. 52 hanging of ceiling fan in repair and connecting up including provision 2 core single flexible cable for ceiling rose / connector to fan including clean of blade / body cover etc complete all as specified and directed. 53 led pannel recess mountedultra slim 2x2 36 watts lit tile in aluminum extruded housing with opal diffuser suitable for perfect lighting complete including cutting hole of required size in pop / false ceiling making good disturbed including taking down any type ceiling fitting, fixed as in repair complee all as specified and directed. 54 led pannel recess mounted 2x2 36 wattscool day light fitting with heat exchanger unit, led driver, surge protection complete including cutting hole of required size in pop / false ceiling making good disturbed including taking down any type ceiling fitting, fixed as in repair complee all as specified and directed. 55 excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying cables, poles, stay etc and getting out in soft and loose soil all as specified & directed by engineer in charge. 56 returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified. 57 removal of excavated material to distance not exceeding 250 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point in soil, complete all as specified and directed. 58 32mm outer dia, double walled corrugated ( dwc ) hdpe duct pipe conforming to is 14930 part ii with anti rodent and non flame propogating properties of approved colour with fittings for cable protection from approval make complete , all as specified and directed 59 xlpe insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm, 2 core, all as specified and directed. 60 xlpe insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 sqmm, 4 core, all as specified and directed. 61 led 10 w bollard light ip65 having a cylindrical body placed on top ideal for architectural outdoor lighting , typically giving off light from the sides, suitable to illuminate walkways , steps of pathways complete all as specified and directed.make : crompton / havells / bajaj...

Military Engineer Services - Haryana

40154835 tender for misc repair incl internal elect and improvement to md jco / or accn sector ‘d’ and ‘f’at chandimandir; 1 taking down carefully aluminum / copper point wiring on & including hard wood battens, surface conduit and board / blocks etc or through conduits for light , socketor power point , fan point complete incl fitting such as switches , sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials ( other than those for which credit has been given by the contractor ) to the mes stores yard for keeping in safe custody complete 2 point wiring with approved colour code multi stranded copper conductor, pvc insulated and unsheathed frlsh cable of size 1.5 sqmm , 1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, pvc insulated and unsheathed frlsh cable of size 1.5 sqmm , 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofone light / bell / buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. 3 all as per serial item 02 herein before but for socket outlet 3 pin 5 amps on same board complete all as specified and directed 4 all as per serial item 02 herein before but for socket outlet 3 pin 6 amps on independentboard complete all as specified and directed 5 all as per serial item 02 herein before but one socket outlet three pin , 6 / 16 amp, independent board, with 2.5 sqmm ( nominal area ) frlshcable & 2.5 sqmm ( nominal area ) cable as earth continuity conductor 6 material and labour forpoint wiring with approved colour code multi stranded copper conductor, pvc insulated and unsheathed frlsh cable of size 1.5 sqmm , 1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, pvc insulated and unsheathed frlsh cable of size 1.5 sqmm , 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed pvc conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofone light / bell / buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. 7 all as per serial item 06 herein before but for socket outlet 3 pin 5 amps on same board complete all as specified and directed 8 all as per serial item 06 herein before but for socket outlet 3 pin 6 amps on independentboard complete all as specified and directed 9 all as per serial item 06 herein before but one socket outlet three pin , 6 / 16 amp, independent board, with 2.5 sqmm ( nominal area ) frlshcable & 2.5 sqmm ( nominal area ) cable as earth continuity conductor 10 switch modular type ( isi marked ) , single pole, one way 6 amps, one module ( isi marked ) , complete all as specified & directed. 11 switch modular type ( isi marked ) , single pole, one way 16 amps, one module ( isi marked ) , complete all as specified & directed. 12 socket shutters outlet 2 / 3 pin 6 amp modular type multi purpose combined two module ( isi marked ) , complete all as specified & directed. 13 socket shutters outlet 2 in 1 pin 6 / 16 amp modular type multi purpose combined 2 module ( isi marked ) , complete all as specified & directed. 14 modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. 15 modular switch type bell push, single pole, 230 volt one module, ( isi marked ) complete all as specified and directed. 16 switch piano, flush type, 6 amps, 230 volts, single pole, one way ( isi marked ) complete all as directed by engineer in charge 17 switch piano, flush type, 16 amps, 230 volts, single pole, one way ( isi marked ) complete all as directed by engineer in charge 18 sockets outlet multipurpose 2 in 1 pin, 6 and 6amps flush type isi marked all as specifiedand directed by engineer in charge 19 sockets outlet multipurpose 2 in 1 pin, 6 and 16amps flush type isi marked all as specifiedand directed by engineer in charge 20 stepped type electronic fan regulator flush type complete all as specfied and directed. 21 electric bell, ding dong, ac, 230 volts, single pole all as specified and directed by engineer in charge. 22 bell push, paino type, 6 amps, 230 volts, single pole, complete all as directed by engineer in charge 23 ceiling rose, pvc or polycarbonate of size 65mmx50mm three terminals ( isi marked ) all as specifiedand directed by engineer in charge. 24 lamp holder, pvc / polycarbonate type with back plate angular type fixed on wall suitable for batten fitting , complete all as specified and directed. 25 led lamp9 watts, b 22 type complete all as specified . 26 led light fitting 1x9w / 1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable sizefixed as in repair complete all as specified and directed. 27 slim led lights fitting, 4 feet, 1x 20w, 220v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. 28 slim led lights fitting, 2 feet, 1x 10w, 220v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. 29 taking down carefully old copper or aluminium sub main wiring of any nos of wiring and size with earth wire on wooden batten / surface conduit / casing capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. 30 sub main wiring with two singlecore frlsh pvc insulated and unsheathed cable with copper conductor of size 4 sqmm ( nominal area ) , 1100 volt grade ( with approved colour coding as per is ) with and including continuous earth wire of size 4 sqmm pvc insulated and unsheathed frlsh multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughpvc concealed conduit 25mm size ( minimum size ) , cutting chases in walls for pvc concealed conduit and making good the disturbed surfacesby providing by wall putty / pop after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. 31 sub main wiring with two singlecore frlsh pvc insulated and unsheathed cable with copper conductor of size 6 sqmm ( nominal area ) , 1100 volt grade ( with approved colour coding as per is ) with and including continuous earth wire of size 6 sqmm pvc insulated and unsheathed frlsh multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughpvc concealed conduit 25mm size ( minimum size ) , cutting chases in walls for pvc concealed conduit and making good the disturbed surfacesby providing by wall putty / pop after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. 32 supply and fixing sub main wiring with two singlecore frlsh pvc insulated and unsheathed cable with copper conductor of size 10 sqmm ( nominal area ) , 1100 volt grade ( with approved colour coding as per is ) with and including continuous earth wire of size 10 sqmm pvc insulated and unsheathed frlsh multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughpvc concealed conduit 25mm size ( minimum size ) , cutting chases in walls for pvc concealed conduit and making good the disturbed surfacesby providing by wall putty / pop after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.note for serial item no 38, 39 & 40 : ( i ) for the purpose of measurement, 2 single core of 10 sqmm and one single core earth cable of 10 sqmm cableshall be considered as 1 running metre. ( ii ) pvc conduit and cutting chases will be measured and paid separtely ( iii ) colour code shall be red for phase, black for neutral and green for earth 33 supply and fixing sub main wiring with four singlecore frlsh pvc insulated and unsheathed cable with copper conductor of size 10 sqmm ( nominal area ) , 1100 volt grade ( with approved colour coding as per is ) with and including continuous earth wire of size 10 sqmm pvc insulated and unsheathed frlsh multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughpvc concealed conduit 25mm size ( minimum size ) , cutting chases in walls for pvc concealed conduit and making good the disturbed surfacesby providing by wall putty / pop after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.note : ( i ) for the purpose of measurement, 4 single core of 10 sqmm and one single core earth cable of 10 sqmm cableshall be considered as 1 running metre. ( ii ) pvc conduit and cutting chases will be measured and paid separtely ( iii ) colour code shall be red for phase, black for neutral and green for earth 34 cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar ( 1:3 ) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth complete all as specified and directed . 35 disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as dbs, junction box, panels of any size complete with all mccbs , mcbs etcand removing from site, complete all as specified and directed . 36 mccb, 125 amps, four pole, 3 phase , 16ka, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed 37 vertical tpn distribution board double door flush mounting with provisions for mccbs incomer upto 100 to 125amps & outgoing 4 way having ip 43 protection complete all as specified and directed . 38 tpn distribution board double door flush mounting with provisions for mcb tpn 6 way having ip 43 protection complete all as specified and directed . 39 mcb db, ip 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 12 way spn with 200 amps busbar 240v completed all as specified and directed. 40 mcb db, ip 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way spn with 200 amps busbar 240v completed all as specified and directed. 41 mcb db, ip 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 04 way spn with 200 amps busbar 240v completed all as specified and directed. 42 sheet metal enclosure for db, flush mountedsingle door suitable for 2 way spnwithout busbar 240v completed all as specified and directed. 43 mcb, spn , 240 volt, 32amps, 10 ka , c series including connection with suitable size aluminium / copper lugs complete all as specified and directed 44 mcb, spn , 240 volt, 40 to 63amps, 10 ka , c series including connection with suitable size aluminium / copper lugs complete all as specified and directed 45 mcb , sp , 240 volt, 6amps to 32amps, 10 ka , c series including connection with suitable size aluminium / copper lugs complete all as specified and directed 46 mcb , tpn / fp 40 to 100 amp 415 volts, 10 ka , c series including connection with suitable size aluminium / copper lugs complete all as specified and directed 47 earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of gi wire 4mm dia ( 8 swg ) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore gi light grade ( isi marked ) with funnel and wire mesh, including all necessary excavation and earth work, pcc chamber in plain cement concrete ( 1:3:6 ) type c 1 and pit cover of presast rcc with ms frame etc and all as shown in electrical plate no 3 of mes sch part i ( 2009 ) , complete including dismantling of old earthing, all as specified and directed. note ( s ) : ( i ) rcc pit cover shall be pre cast of rcc ( 1:2:4 ) type b 1, 80mm thick reinforced with xpm not less than 4kg / sqm. ( ii ) pcc chamber shall be constructed 500 mm away from the edge of earth pit. ( iii ) rate shall include earth lead and protection pipe of length 7.5m ( iv ) earth resistance should be less than 3ohm. in case the test results are not found below 3ohm, complete earthing will be redone without any extra cost to govt. ( v ) unit rate including protection pipe and gi wire 4.00mm dia from top to earth plate upto 7.5 meter 48 earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including galvanised iron strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore gi light grade ( isi marked ) with funnel and wire mesh, including all necessary excavation and earth work, pcc chamber in plain cement concrete ( 1:3:6 ) type c 1 and pit cover of presast rcc with ms frame etc and all as shown in electrical plate no 3 of mes sch part i ( 2009 ) , complete including dismantling of old earthing, all as specified and directed. note ( s ) : ( i ) rcc pit cover shall be pre cast of rcc ( 1:2:4 ) type b 1, 80mm thick reinforced with xpm not less than 4kg / sqm. ( ii ) pcc chamber shall be constructed 500 mm away from the edge of earth pit. ( iii ) rate shall include earth lead and protection pipe of length 7.5m ( iv ) earth resistance should be less than 3ohm. in case the test results are not found below 3ohm, complete earthing will be redone without any extra cost to govt. ( v ) unit rate including protection pipe and gi strip 32x 6mm from top to earth plate upto 7.5 meter 49 fabrication, install, testing and commission of wall mounted sheet metal busbar chamber cpri approved, grouted with nut and bolts ( with proper locking arrangement and holes to distribute circuits ) of size 600x500x300mm with copper strip 40mm x 6mm ( 04 nos ) of length 450mm with approved colour coded and pvc adhesive coated, ip 54 as per is 13947 protection fixed on insulator with the help of nut / bolts including provison of 10 nos 08 mm dia hole with 8 mm dia 50 mm long nut / bolts with 02 nos of washer connected with 16 sqmm single core colour coding stranded copper cable with thimble / lugs including one mccb, 125 amps, four pole 3 phase 25 ka, 415 volt with adjustable thermal and megnetic release complete having adjustable type base frame and equal space around mccb as incommer one no, making good distrubed surfaces to match with original all as specifed and directednote: contractor will submit drawing of this panel to engr in charge for approval. 50 led street light fitting 35 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with ip 66 protection complete all as specified and directed. 51 fixing only exhaust fan in repair and connecting up to and including provision of 2 core single flexible cable for ceiling rose / connector to fan including clean of blade / body cover etc complete all as specified and directed. 52 hanging of ceiling fan in repair and connecting up including provision 2 core single flexible cable for ceiling rose / connector to fan including clean of blade / body cover etc complete all as specified and directed....

Military Engineer Services - Haryana

39894645 tender for augmentation of external elect sup at k area under ge chandigarh; 1 supply, installation, testing and commissioning of 500 kva outdoor transformerfloor mounted11kv on ht side and 433 volts on lt side at no load step down 3 phase 50 c / s ac double wound oil immersed naturally cooled with external cooling tubes core type. transformer with off load tapping on ht side to vary secondary voltage + 7.5% in steps of + 2.5 %. the transformer shall confirm with the requirement of is 2026 and oil shall confirm to is 335, 1983. the temp rise shall not exceed 55 degeree centigrade in winding and 45 degree centigrade in oil when measured by the resistance method after continous full load run and on ambient temp of 48 degree centigrade, copper wound, ( losses shall be as per is 1180 part i 2014 level 3 ) , all as specified. the transformer shall include the following: ( a ) hv bushing of suitable size. ( b ) lv glands and cable box of suitable size. ( c ) oil conservator. ( d ) dehydrating breather with first fill of dehydrating agent. ( e ) thermometer pocket with thermometer dial of suitable size. 2 ( f ) two earthing terminals on tank and take cover with lugs to suit 32x6 mm gi strip. ( g ) rating plate. ( h ) terminal marking plate. ( i ) oil level gauge. ( j ) oil drain and filter valve. ( k ) lifting lugs ( l ) four plain rollers. ( m ) oil filter plug with connection complete. ( n ) extra bushing for neutral outside the cable box for providing independent earthing. ( o ) oil filling hole with cap. ( p ) first filling of oil. ( q ) one cable box on lv side with one cable gland suitable for reception of 01 no 3.5 core 400 sqmm lt cable. 3 shifting of transformer of different capacity including removing from existing sub station ectrically and installed at different location as directed by engr in charge at bde hq k area 4 supply, installation, commissioning and testing of feeder pillar box outdoor type, kiosktype, cpri approved, lt ( 415 volts, 50 hz , 3 phase, 4 wire supply ) floor mounted, factory assembled, double door weather and vermin proof made out of 3.15 mm thick crca sheet, double door type openable from front and rear side, rubber lining, locking arrangement, painted externally and internally with powder coated paint ( first quality ) complete mounted on ms channel of min size 75x40 mm with pcc work and including under mention items in independent compartment with sufficient working space including taking out existing unserviceable feeder pillar complete all as specified anddirected by engineer in charge : incomming: ( i ) bus baraluminium of 1250amp cap on epoxy insulators 01 set ( 04nos ) ( ii ) acb, 4 pole, 800 amps, 415v, 50ka 01 no.outgoing: ( i ) mccb, 4 pole, 415v, 35ka, 400 amps 01 no. ( ii ) mccb, 4 pole, 415v, 35ka, 200 amps 02 nos. ( iii ) mccb 63 amp 4 pole 25ka 02 nos. ( iv ) mcb tpn 63 amp 02 nos. ( v ) ammeter 0 800a with selector switch 01 no. ( vi ) voltmeter 0 500v with selector swtich 01 no. ( vii ) indicator lamps with control fuses 01 set ( each set of three ) 5 all asper item no 3 above but as following : incomming: ( i ) bus bar aluminium of 750amp cap on epoxy insulators 01 set ( 04nos ) ( ii ) mccb, 4 pole, 500 amps, 415v, 50ka 01 no.outgoing: ( i ) mccb, 4 pole, 415v, 35ka, 315 amps 01 no. ( ii ) mccb, 4 pole, 415v, 35ka, 100 amps 02 nos. ( iii ) mccb 63 amp 4 pole 25ka 02 nos. ( iv ) mcb dp 32 amp 01 nos. ( v ) ammeter 0 500a with selector switch 01 no. ( vi ) voltmeter 0 500v with selector swtich 01 no. ( vii ) indicator lamps with control fuses 01 set ( each set of three ) 6 all asper item no 3 above but as following : incomming: ( i ) bus baraluminium of 600amp cap on epoxy insulators 01 set ( 04nos ) ( ii ) mccb, 4 pole, 400 amps, 415v, 50ka 01 no.outgoing: ( i ) mccb, 4 pole, 415v, 35ka, 400 amps 01 no. ( ii ) mccb, 4 pole, 415v, 35ka, 200 amps 02 nos. ( iii ) mccb 63 amp 4 pole 25ka 01 nos. ( iv ) mcb dp 32 amp 01 nos. ( v ) ammeter 0 600a with selector switch 01 no. ( vi ) voltmeter 0 500v with selector swtich 01 no. ( vii ) indicator lamps with control fuses 01 set ( each set of three ) 7 all asper item no 3 above but as following : incomming: ( i ) bus baraluminium of 600amp cap on epoxy insulators 01 set ( 04nos ) ( ii ) mccb, 4 pole, 400 amps, 415v, 50ka 01 no.outgoing: ( i ) mccb, 4 pole, 415v, 35ka, 400 amps 01 no. ( ii ) mccb, 4 pole, 415v, 35ka, 200 amps 01 nos. ( iii ) mccb 63 amp 4 pole 25ka 01 nos. ( iv ) mcb dp 32 amp 03 nos. ( v ) ammeter 0 600a with selector switch 01 no. ( vi ) voltmeter 0 500v with selector swtich 01 no. ( vii ) indicator lamps with control fuses 01 set ( each set of three ) 8 all asper item no 3 above but as following : incomming: ( i ) bus baraluminium of 600amp cap on epoxy insulators 01 set ( 04nos ) ( ii ) mccb, 4 pole, 400 amps, 415v, 50ka 01 no.outgoing: ( i ) mccb, 4 pole, 415v, 35ka, 400 amps 01 no. ( ii ) mccb, 4 pole, 415v, 35ka, 200 amps 02 nos. ( iii ) mccb 63 amp 4 pole 25ka 02 nos. ( iv ) mcb dp 32 amp 02 nos. ( v ) ammeter 0 600a with selector switch 01 no. ( vi ) voltmeter 0 500v with selector swtich 01 no. ( vii ) indicator lamps with control fuses 01 set ( each set of three ) 9 supply, laying, jointing and testing cable xlpe insulated screened pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 11000 volts grade with stranded aluminium conductor of size 95 sqmm 3 core including taking out unserviceable cable complete all as specified and directed. 10 supply, laying, jointing, testing and commissioning cable end termination jointing kit 11 kv ( earthed ) grade cable for outdoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core xlpe armoured alluminium conductor cable of size 50 sqmm to 95 sqmmm including taking out unserviceable cable complete all asspecified and directed by engineer in charge. 11 supply, laying, jointing, testing xlpe insulated screened pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 630 sqmm 3.5 core in trenches / ducts / through pipes / under culverts including taking out unserviceable cable etc complete all asspecified and directed 12 supply, laying, jointing and testing cable xlpe insulated screened pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 400 sqmm 3.5 core in trenches / ducts / through pipes / under culverts etc including taking out unserviceable cable complete all asspecified and directed . 13 supply, laying, jointing and testing xlpe insulated screened pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 300 sqmm 3.5 core in trenches / ducts / through pipes / under culverts etc complete all asspecified and directed . 14 supply, laying, jointing and testing xlpe insulated screened pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 240 sqmm 3.5 core in trenches / ducts / through pipes / under culverts etc including taking out unserviceable cable complete all asspecified and directed . 15 supply, laying, jointing and testing xlpe insulated screened pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 185 sqmm 3.5 core in trenches / ducts / through pipes / under culverts etc including taking out unserviceable cable complete all asspecified and directed . 16 earthing complete with galvanized steel earth plate electrode 600x600x6mm surrounded by mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less 2.25mtr below ground level with top edge of earth plate at a depth of not less than 1.50mtrs below ground level connected with and including 32x6mm galvanized iron strip as earthing lead by means of bolts, nuts, check nuts and washers made out of galvanized iron, 20mm dia medium grade gi pipes for watering with funnel, wire mesh and 40mm gi light grade protection pipe for gi strip and including necessary excavation, earth work, pcc 1:3:6 type c 2 concrete pit and rcc pit cover charcoal and common salt filling in alternate layers complete all asspecified and directed by engineer in charge on electrical plate no 3 of ssr par i of 2009.note: ( i ) if desirable earthing result not found re done earthing without any extra charge until get required earth resistance. ( ii ) the result sheet of earthing may submit to sub division level by contractor. 17 earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire, 4mm dia ( no. 8 swg ) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore ( light grade ) gi pipe for protection of earthing lead, 20 mm bore ( light grade ) gi pipe for watering with funnel, wire mesh and including necessary excavation and earth work, pcc 1:2:4 type b 1 pit and 50 mm thick rcc m 25 ( design mix ) reinforced with xpm ( weight not less than 3 kg / sq m ) pit cover, c.i frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate no. 3 of ssr part i ( 2009 ) complete all asspecified and directed by engineer in charge.note : ( i ) the unit rate includes for protecton pipe 15mm and gi earth strip 4mm from top of earth plate upto 7.50 metre above ground level. ( ii ) if desirable earthing result not found re done earthing without any extra charge until get required earth resistance. ( iii ) the result sheet of earthing may submit to sub division level by contractor. 18 supply & fixing steel water tubing, galvanised, light grade, isi marked, 80 mm bore with all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed by engineer in charge. 19 supply & fixing steel water tubing, galvanised, light grade, isi marked, 100 mm bore with all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed by engineer in charge. 20 excavation in trenches in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 mtr in depth and getting out soil including forming bottom surface to required slope / gradient forlaying cables / pipes etc.all as specified and directed by engineer in charge including removing cable protection pcc covers / bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 metre complete all as specified and directed.note : ( i ) excavation shall be made carefully in order to avoid damage of existing cables and protection covers. ( ii ) the excavation work may be carried out in short lengths for locating fault in under ground cables at different locations. 21 returning, filling in ( soils ) including spreading, leveling, watering and well ramming in layers not exc25 cm thickafter the cables etc. are laid, jointed and tested complete all as specified and directed by engineer in charge. 22 removal of surplus excavated spoil ( soils ) not exceeding 50 metre distanceand depositing where directed by engineer in charge at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. 23 sand filling under floors or in foundations including watering and consolidation complete all as specified and directed 24 supply and laying factory made unreinforced precast concrete cable cover, class hv, type 1 flat size 300mm x 180mm x 40mm for protection of ht cable laid flat length wise prependicular to the axis of cable complete all asspecified and directed by engineer in charge. 25 supply and laying burnt bricks sub class b old size for cable protection laid flat lengthwise perpendicualr to the axis of cable complete all as specified and direted by engineer in charge. 26 supply & fixing galvanised iron strip 32x6mm burried in ground with saddles and fixing screw etc.for roof conductors and down conductor above groundfor earthing complete all as specified and directed 27 supply & fixing danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with m.s. clamps, bolts and nuts of approved size, for ht, 25x2 cm size complete all as specified and directed 28 supply & fixing in replacement air break switch gang operated triple pole, machanically operated, mounted on insulatorand steel framewith operating mechanisim worked from ground level, for current rating upto 200 amps, 11 kv complete all as specified and directed by engineer in charge. 29 supply & fixing lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 ka on 11000 volts complete all as specified and directed by engineer in charge. 30 m & l for cable route indicator made of cast iron plate circular type 10 cm dia duly marked blue colour marked lt cabless arrows mark up side duly welded / nut, bolt with angle iron 45 / 45 equal size and 45 cm long duly grouted on fround with pcc ( 1:3:6 ) as in foundation & earth work excavation etc complete all as specified and directred at site by the engineer in charge....

Indian Army - Haryana

39851414 bids are invited for ssl spares hyd oil temp gauge , water temp gauge , work light switch , beacon light switch , dual indicator bty heater , dual indicator water temp , fuel gauge , 4 way ignition switch , fan , positive bty cable , negative bty cable , direction indicator light , earth wire , head light , auxiliary cable , hydraulic filter , flexible hose clip , air filter element inner , air filter element outer , arm cyl seal kit , cabin lift cyl seal kit , rotating cyl seal kit , lifting cyl seal kit , swinging arm cyl joint kit , bucket cyl seal kit , decal set , chassis harness , cabin harness , horn , hour meter , internal light switch , top roof glass total quantity : 44...

Dakshin Haryana Bijli Vitran Nigam Limited - Haryana

39766355 tender for 2x12.5 mva, 33kv gis sub station, sector 16/17, hisar 12.5 mv three phase 50 hz, 33/11 kv step down outdoor onan power transformer complete with all accessories/fittings and conforming to latest nigams technical specification csc 74/rii with amendments relevant iss with latest amendments. nos 2 7411073 7707515.92 15415031.84 105926.00 211852.00 15626883.84 2 33 kv gis incommer panel, 36 kv, 1250a with 1800 mva (31.5 ka for 3second) rupturing capacity gis incommer panel for in door use nos 2 _ 3676349.00 7352698.00 222144.35 444288.70 7796986.70 3 33 kv gis bus coupler, 36 kv, 1250a with 1800 mva (31.5 ka for 3second) rupturing capacity gis bus coupler for in door use 33 kv gis outgoing panel, 36 kv, 1250a with 1800 mva (31.5 ka for 3second) rupturing capacity gis outgoing panel for in door use nos 3 _ 2906472.75 8719418.25 215144 645432.00 9364850.25 5 11 kv gis incommer panel, 12 kv, 1600a with 500 mva (26.3 ka for 3second) rupturing capacity gis incommer panel for in door use 11 kv gis bus coupler, 12 kv, 1600a with 500 mva (26.3 ka for 3second) rupturing capacity gis bus coupler for in door use nos 1 _ 2737600.00 2737600.00 150096 150096 2887696 7 11 kv gis outgoing panel, 12 kv, 800a with 500 mva (31.5 ka for 3 second) rupturing capacity gis outgoing panel for in door use 11 kv gis outgoing panel, 12 kv, 800a with 500 mva (31.5 ka for 3 second) rupturing capacity gis outgoing panel for in door use (for sub station transformer) nos 1 _ 2308968.00 2308968.00 131465.50 131465.50 2440433.50 9 11 kv gis outgoing panel, 12 kv, 800a with 500 mva (31.5 ka for 3 second) rupturing capacity gis outgoing panel for in door use (for capacitor panel) nos 2 _ 2312254.25 4624508.50 131538.75 263077.50 4887586.00 10 indoor jointing kit (heat shrinkable) for 33 kv ht tr xlpe 3cx400 mm2 cable at gis swbd (if not included in the price of respective gis panel) set 5 0 11 indoor jointing kit (heat shrinkable) for 11 kv ht tr xlpe 3cx300 mm2 cable at gis swbd (if not included in the price of respective gis panel indoor jointing kit (heat shrinkable) for 11 kv ht tr xlpe 3cx95 mm2 cable at gis swbd (if not included in the price of respective gis panel) set 1 0 13 indoor jointing kit (heat shrinkable) for 11 kv ht tr xlpe 1cx630 mm2 cable at gis swbd (if not included in the price of respective gis panel) set 8 0 14 lt distribution board for 33kv sub stn as per nigams tech. specification. nos 1 35005.00 40780.83 40780.825 2512.00 2512.00 43292.83 15 ni cd alkaline battery capacity (100ah) with static battery charger as per nigams specification. nos 1 199626.00 232564.29 232564.29 7308.00 7308.00 239872.29 16 33kv lightening arrestor sub stn type 30kv 10ka with surge counter. nos 12 3950.00 4601.75 55221.00 291.00 3492.00 58713.00 17 11kv lightening arrestor sub stn type 9kv 10ka (heavy duty) nos 12 1900.00 2213.50 26562.00 52.00 624.00 27186.00 18 11kv lightening arrestor 9 kv 5 kv nos 33 380.00 442.70 14609.10 52.00 1716.00 16325.10 19 33kv post insulators nos 4 411.00 478.82 1915.26 30.00 120.00 2035.26 20 11kv ct or pt or nct complete in all respects nos 2 9687.00 11285.36 22570.71 184.00 368.00 22938.71 21 3 phase 11kv/0.433 0.250kv, 100kva oil immersed, naturally cooled, aluminium wound outdoor type station transformer as per latest nigam technical specfication with amendment thereof. nos 1 168227.00 195984.46 195984.46 664.75 664.75 196649.21 22 11 kv automatically switched capacitor apfc capacitors panal 4.8 mvar complete (with l&e switch, structure and all allied material as per nigam’s tech. spec., relevant iss and latest amendments . nos 2 1121495.00 1306541.68 2613083.35 76977.00 153954.00 2767037.35 23 33kv isolators (630 amps) 36 kv, 630a switch outdoor type load break switch nos 3 236000.00 274940.00 824820.00 2000.00 6000.00 830820.00 25 12 kv, 400a switch outdoor type load break switch nos 11 187272.00 2059992.00 2000.00 22000.00 2081992.00 26 33kv steel structures galvanised by using steel of sail/tata make complelte in all respect i/c base plate, gi nuts, bolts & washers etc. (as per drawings) 26 (a) structure for 33 kv la (galvanised) wt. 76.38 kg nos 12 8334.00 9709.11 116509.32 379.00 4548.00 121057.32 26(b) structure for 33 kv post insulators (galvanised) wt. 76.38 kg nos 4 8334.00 9709.11 38836.44 379.00 1516.00 40352.44 26 ( c) structure for 33 kv isolator (galvanise) wt.288.36 kg nos 2 31462.00 36653.23 73306.46 1430.00 2860.00 76166.46 26 (d) structure for 11 kv nct (galvanise) wt.92.37 kg nos 2 10078.00 11740.87 23481.74 459.00 918.00 24399.74 27 33kv ht tr xlpe armoured cable of size 3 core 400 sq mm mtrs 250 3521.59 4102.65 1025663.09 74.53 18632.50 1044295.59 28 11kv single core tr xlpe armored cable of size 630mm2 mtrs 480 914.69 1065.61 511494.65 22.36 10732.80 522227.45 29 11 kv tr xlpe armoured cable of size 3 c x 300 sq. mm mtrs 650 1635.54 1905.40 1238512.67 44.72 29068.00 1267580.67 30 11 kv tr xlpe armoured cable of size 3 c x 95 sq. mm mtrs 50 871.35 1015.12 50756.08 26.83 1341.50 52097.58 31 outdoor jointing kit (heat shrinkable) for 33 kv ht tr xlpe 3cx400 mm2 cable set 8 3571.00 4160.22 33281.72 727.00 5816.00 39097.72 32 outdoor jointing kit (heat shrinkable) for 11 kv ht tr xlpe 1cx630 mm2 cable set 8 840.00 978.60 7828.80 727.00 5816.00 13644.80 33 lt pvc un armoured cable 3.5 c x 95 sq. mm mtrs 30 352.50 410.66 12319.94 16.77 503.10 12823.04 34 lt pvc un armoured cable 2c x 10 mm2 for yard lighting. mtrs 400 43.35 50.51 20202.03 5.03 2012.00 22214.03 35 un armoured copper control cable 2c x 4mm2 36 un armoured copper control cable 2c x 6mm2 mtrs 120 142.81 166.37 19964.14 11.00 1320.00 21284.14 37 un armoured copper control cable 3c x 4mm2 mtrs 100 138.43 161.28 16127.56 13.00 1300.00 17427.56 38 un armoured copper control cable 4c x 4mm2 mtrs 600 179.54 209.16 125497.76 13.00 7800.00 133297.76 39 un armoured copper control cable 6c x 4mm2 mtrs 100 260.45 303.42 30342.43 16.00 1600.00 31942.43 40 un armoured copper control cable 7c x 2.5mm2 mtrs 320 195.37 227.60 72832.82 18.00 5760.00 78592.82 41 un armoured copper control cable 10c x 2.5mm2 mtrs 520 278.76 324.75 168871.60 18.00 9360.00 178231.60 42 gi channel 100x50x6mm (gi) various size of only tata/sail make kgs 500 71.98 83.86 41928.35 7.00 3500.00 45428.35 43 gi angle iron 50 x 50 x 6 mm (gi) various size of only tata/sail make kgs 300 72.039 83.93 25177.63 7.00 2100.00 27277.63 44 gi flat 50 x 6 mm of only tata/sail make kgs 500 74.34 86.61 43303.05 5.00 2500.00 45803.05 45 earth mat for switch yard 75x8 mm kgs 5600 76.71 89.37 500456.04 4.00 22400.00 522856.04 46 gi nut & bolt off size kgs 80 84.00 97.86 7828.80 0.00 0.00 7828.80 47 g.i pipe 40 mm dia 6 mtr. long for earthing set b class, weight should not be less than 19.38kg nos. 20 1901 2214.67 44293.30 234.16 4683.20 48976.50 48 premier synthetic insulating mat (class b as per isi 15652:2006) mtr. 20 2777 3235.21 64704.10 0.00 0.00 64704.10 49 switch yard illumination system 49 (a) led street light fixtures with 130 watts lamp with 5 years warranty 49 (b) 9 metres long pcc poles for yard lighting nos 12 2500.00 2912.50 34950.00 379.05 4548.60 39498.60 50 fire fighting/safety eqpt for control room 50 (a) dry chemical type fire extinguisher 5 kgs nos 3 1028.00 1197.62 3592.86 0.00 0.00 3592.86 50 (b) co2 type fire extinguisher 10 kgs nos 3 6170.00 7188.05 21564.15 0.00 0.00 21564.15 50 (c) gas pressure ctc fire extingiusher nos 2 1440.00 1677.60 3355.20 0.00 0.00 3355.20 51 fire fighting/safety eqpt for yard 51 (a) dry chemical type fire extinguisher 10 kgs nos 2 1440.00 1677.60 3355.20 0.00 0.00 3355.20 51 (b) co2 type fire extinguisher 22.5 kgs nos 2 15425.00 17970.13 35940.25 0.00 0.00 35940.25 51 (c) fire buckets with covered stand (capacity) 10 ltrs nos 12 72.00 83.88 1006.56 0.00 0.00 1006.56 52 earthing of s/stn. with pipe & earthing plate complete with machinary chamber nos 18 5090.00 5929.85 106737.30 365.00 6570.00 113307.30 53 earth road weight 6.175 kg. no 36 434.00 505.61 18201.96 151.00 5436.00 23637.96 54 2 no. table size 4x6 sq ft (geeken/neelkamal make), 1 nos. wooden bench 2.5x6 sq ft (geeken/neelkamal make), 12 no. chair (neelkamal/geeken), 8 no. celing fan(orient/ crompton/bajaj), one no. desert air cooler with copper winding branded, 2 no. exaust fan for control room (crompton/bajaj/havells), 2 no. exaust fan for washrooms (crompton/bajaj/havells), 1 no. wall mountable ro+uf+tds control 8 ltr tank water purifier(kent/aquaguard/havells), 20 nos. 30 watts led tubelights(philips/syska/havells), safety charts, comletetool kit including all number d spanner set taparia make, medical kit, sub / stn.sign board,rubber mate,wall clock big size (ajanta brand ), thermometer, first aid box, one no. foldable frp ladder 20 feet, one no. megger 5kv as per csc 57/r 1/2015 16, 2 pair safety shoes, seprate safety kit for 11 & 33 kv voltage level, 2 nos safety belt, 2 nos raincoat, 4 nos safety helmet with led light & sensor, 1 no. farrata fan (bajaj/usha/crompton),hydraulic crimping tool as per requirement of 33 kv substation(jainsons make) 1 construction of s/h bldg i/c cost of all materials viz cement, steel reinforcement, bajri, crusher, bricks, tools, labour, men & machinery etc. etc. for completion of switch house building i/c providing internal water supply and sewerage system and fixtures in the toilet, ms staircase with hand railing (wt. 300 kg approx.) outside, pvc water storage tank, internal electrical wiring and fittings complete in all respects as per dhbvn’s approved design, drawings & bid specification for civil works as per vol iii of bid and directions of the engineer incharge (any other work incidental to complete the building shall not be paid extra.) each 1 job 5955011.40 2 construction of two nos. transformer plinths i/c cost of all materials, labour, men & machinery etc. etc. complete in all respects as per dhbvn’s approved design, drawings, electrical layout, bid specification and directions of the engineer. (any other work incidental to complete the structure shall not be paid extra). each 1 job 470909.00 3 construction of the foundations for two bays for various structures as per electrical lay out drgs. i/c cost of all material, labour men & machinery complete in all respect as per dhbvn’s approved design, drawings, bid specification & directions of engineer –in charges. (any other work incidental to complete the work shall not be paid extra).additional cost of water proofing due to high water table. each 1 job 1366669.30 4 cost. of cable trenches in the s/yard i/c rcc covers 30 mtr. long i/c cost of all material, labour men & machinery complete in all respects as per dhbvn’s approved design, drawings, bid specifications and directions of the engineer incharge. (in case length of trenches varies as per site requirement payment shall be made on prop. basis)(any other work incidental to complete the work shall not be paid extra). each 1 job 953149.00 6 construction of unclimble fencing for the switch yard and distribution t/f i/c cost of all materials, labour, men & machinery etc. etc. complete in all respects, as per dhbvn’s approved design, drawings, bid specifications and directions of the engineer incharge. (length 175.50 m; in case length of fencing varies as per site requirement payment shall be made on prop. basis). each 1 job 1188047.30 7 supply & spreading of bajri of 20mm nominal size in the complete yard area (both bays) i.e. within toe walls of u/c fencing and road & s/stn. transformer area i/c anti weed treatment and site surfacing complete in all respects, as per specifications and directions of the engineer incharge. (any other work incidental to complete the work shall not be paid extra). each 1 job 46726.00 8 earth filling with good earth as per the satisfaction of engineer incharge and leveling in layers (as per specification), dressing i/c carriage irrespective of lead, loading and unloading, watering and compaction in layers with roller i/c compaction of earth for switch yard area, roads and balance area of the substation land (entire area within boundary wall) complete in all respects to achieve the finished designed level (100.00 mtr.). the earth should be leveled with computerized leveler in complete area of s/stn land. earth filling in 3 feet width be filled along the outer periphery of the compound wall upto finished designed level (approx. qty. 2262 cum) (note: in case qty. varies as per site requirements, payment shall be made on proportionate basis) each 1 job 3179934.00 9 construction of cc road & extra approach cc road in the sub station area complete in all respects as per dhbvn’s approved design, drawings, bid specification and directions of the engineer incharge. {the scope of road shall be within the sub stn and outside of main gate of sub stn up to 50’ (approx.) length to join the road in front of the sub stn. (approx. area. 605 sqmt.) (note: in case the area of road varies as per site requirements, payment shall be made on proportionate basis) 11 providing external water supply i/c provision 1 no. underground water storage tank plus providing fire hydrant with 100 feet long flexible cloth pipe 2” dia suitable for fire hydrant and disposal of waste from toilet of s/h building complete in all respects as per dhbvn’s approved design, drawings, bid specifications and direction of engineer in charge. each 1 job 1079919.00 14 p&f of u/c fencing gate and compound wall gate as dhbvn approved design drg. and bid specification and direction of engineer incharge complete in all respect. additional cost of water proofing due to high water table each 1 job 111955.00 15 const. of compound wall on rcc illars upto top all along the boundary of the sub stn with cost of materials tools and plants etc complete in all respects as per dhbvn’s approved design, drawings & bid specifications and directions of the engineer incharge. (approx. length 477.19 mtr.) (note: in case the length of b/wall varies as per site requirements, payment shall be made on proportionate basis) each 1 job 3806306.00 16 p/f of pipeline from main pipe line the work comprising of excavation min. 75mm depth pvc 6kg/cm2 pressure pipeline 50mm dia isi marked, specials, 1 no. gm peat valve of 50mm dia isi marked i/c brick masonry chamber with hci cover i/c making connection with main pipe line complete as per direction of engineer in charge. (approx. length 200 rft) (note: in case qty. varies as per site requirements, payment shall be made on proportionate basis). each 1 job 22400.00 17 6 dia pvc pipe with 6kg/cm2 sewer pipe line @35 mtr. long 1 acsr conductor 150mm2 ( wolf) mtrs 154.92 5.59 180.48 4896.000 883630.00 27369.00 910999.00 2 33kv polymeric pin insulators with pin no 549.00 0 639.59 216 138151.00 0.00 138151.00 3 33 kv polymeric disc insulators70/ 90 kn (b& s type) no 461.00 0 537.07 84 45114.00 0.00 45114.00 4 single tension fittings for 150mm2 acsr conductor no 134.00 0 156.11 84 13113.00 0.00 13113.00 5 pg clamps for 30/50/80/100/150mm2 acsr conductor no 40.00 0 46.60 84 3914.00 0.00 3914.00 6 g.i. pipe 40 mm dia 6 mtr. long for earthing no 1901.00 610.23 2214.67 36 79728.00 21968.00 101696.00 7 gsl 8 swg mtr. 1.12 0.00 810.00 0.00 907.00 907.00 8 gsl 8 swg kgs 94.40 0 109.98 90.000 9898.00 0.00 9898.00 9 gi nuts & bolts off sizes kgs 84.00 0 97.86 100 9786.00 0.00 9786.00 10 danger plates (enamelled) with clamp no 68.00 0 79.22 36 2852.00 0.00 2852.00 11 number plates (enamelled) with clamp no 68.00 0 79.22 36 2852.00 0.00 2852.00 12 phase plate for each phase set of 3 (on each h pole & 4 pole) set 57.00 0 66.41 14 930.00 0.00 930.00 13 barbed wire (galvanized) kgs 97.94 0 114.10 210 23961.00 0.00 23961.00 14 g.i. strip 25x6 mm 9 mtr. long for earthing wt. 10.80 kg (galvanized) no 1148.00 0 1337.42 18 24074.00 0.00 24074.00 kgs 103.84 0 120.97 180.000 21775.00 0.00 21775.00 mtr. 0 1.62 0.00 1000.00 0.00 1620.00 1620.00 16 gi channel 100x50x6mm tata/sail (galvanized) various size kgs 86.376 0 100.63 500.000 50315.00 0.00 50315.00 17 disc fitting (b&s type) no 137.00 0 159.61 84 13407.00 0.00 13407.00 18 gi channel 75x40x6mm 3350mm long (for earth wire) wt. 23.919 kg. no. 2509.00 0 2922.99 10 29230.00 0.00 29230.00 19 gi angle 50x50x6mm kgs 86.45 7.00 100.71 200.000 20142.00 1400.00 21542.00 20 m+6 mtr. extension tower wt. 1695 kg. no. 184935.00 7504.20 215449.28 36 7756174.00 270151.00 8026325.00 21 m+6 mtr. extension tower foundation no. 0 22748 0.00 36 0.00 818928.00 818928.00 22 dismentalment of acsr 150 mm2 mtrs 2.795 0.00 3900.00 0.00 10901.00 10901.00 15 catenary wire 7/14 swg 23 re erection of acsr 150 mm2 mtrs 5.59 3900.00 0.00 21801.00 21801.00 24 dismentalment of 11 mtr. single pole with fitting (unservicable) nos. 449.00 41 0.00 18409.00 18409.00 25 dismentalment of h pole with fitting (unservicable) 11 kv line 1 pcc poles 11 m long no. 5343 0 6224.60 204 1269817.38 0.00 1269817 1(a) pcc pole 11 mtr. for h pole structure no. 1646 0.00 0 0.00 0 1(b) pcc pole 11 mtr. for single pole no. 898 0.00 204 0 183192.00 183192 2 pcc poles 9 m long no. 2500 0 2912.50 0 0.00 0 2(a) pcc pole 9 mtr. for h pole structure no. 1646 0.00 0 0.00 0 2(b) pcc pole 9 mtr. for single pole no. 798 0.00 0 0.00 0 3 11 kv top brackets / hamper 1.480 kg. no. 157.00 0 182.91 62 11340.11 0.00 11340 4 11 kv polymeric pin insulator with pin no. 189 0 220.19 243 53504.955 0.00 53505 5 11 kv polymeric disc. insulator (b&s type) no. 119 0 138.64 180 24954.3 0.00 24954 6 11 kv polymeric disc insulator 45kn (t&c type) no. 116 0.00 135.14 0 0.00 0 7 acsr conductor 100mm2 mtr 86.598 3.35 100.89 9180 926139.6306 30753.00 956893 8 pg clamps for30/50/ 80/100 mm2 ascr conductor no. 40 0.00 46.60 180 8388 0.00 8388 9 stay wire 7/8 swg kg. 99.12 0.00 115.47 1625 187646.55 0.00 187647 10 gsl 8 swg kg. 94.4 0.00 109.98 550 60486.8 0.00 60487 11 v shape x arm 100x50 mm wt. 13.200 kg 12 stay sets 8 long complete with x plat 460mm of angle 65x65x6 mm elbow & rod no. 1228 299.00 1430.62 125 178827.5 37375.00 216203 13 earthing sets with gi pipe 40 mm dia, 6m long for h pole no. 1901 610.23 2214.67 78 172743.87 47597.94 220342 14 earthing with earth rod as per drawing wt. 6.175 no. 434 151.00 505.61 18 9100.98 2718.00 11819 15 g.i. strip 25x6 mm9 mtr. for earthing wt. 10.80 kg. no. 1148 0.00 1337.42 78 104318.76 0.00 104319 16 g.i. nuts & bolts & washer off sizes kg. 84 0.00 97.86 650 63609 0.00 63609 17 eye screw bolts 9”x5/8 no. 41 0.00 47.77 62 2961.43 0.00 2961 18 half clamps no. 156 0.00 181.74 370 67243.8 0.00 67244 19 full clamps no. 247 0.00 287.76 125 35969.375 0.00 35969 20 gi . channel (x arm) 100x50x6mm 2200mm (h pole) no. 2175 0.00 2533.88 80 202710 0.00 202710 21 gi.angle iron 50x50x6mm 2400mm (for earth wire) no. 1118 0.00 1302.47 41 53401.27 0.00 53401 22 gi. angle 50x50x6mm 2860mm (bracing for h. pole) no. 1332 0.00 1551.78 82 127245.96 0.00 127246 23 giangle 50x50x6mm 2200mm (belting for hpole) no. 1025 0.00 1194.13 82 97918.25 0.00 97918 24 giangle 50x50x6mm 2040mm for guarding no. 950 0.00 1106.75 0 0.00 0 25 barbed wire kg. 97.94 0.00 114.10 408 46552.8408 0.00 46553 26 danger plate enamalled no. 68 0.00 79.22 204 16160.88 0.00 16161 27 number plate enamalled no. 68 0.00 79.22 165 13071.3 0.00 13071 28 phase plate for each phase set of 3 (on each hpole & 4 pole) set 57 0.00 66.41 66 4382.73 0.00 4383 29 g.i. channel 75x40x6,2200 mm long ( for h pole) 30 gi channel 100x50x6,1600 mm long ( t off crossing) no. 1582 0.00 1843.03 0 0.00 0 31 disc fitting (t&c type) no. 87 0.00 101.36 180 18243.9 0.00 18244 32 disc fitting (b&s type) no. 137 0.00 159.61 0 0.00 0 33(a) 11 kv 3/c tr xlpe cable 185mm2 for ug mtr. 1192.638 0.00 1389.42 2700 3751442.829 0.00 3751443 33(b) 11 kv 3/c tr xlpe cable 185mm2 for ug (erection charges for 200 mtr cable included in hdpe pipe erection charges) mtr 0 33.54 0.00 2500 0 83850.00 83850 34(a) 11 kv 3/c tr xlpe cable 300mm2 for railway crossing mtr 1635.541 0.00 1905.41 400 762162.106 0.00 762162 34(b) 11 kv 3/c tr xlpe cable 300mm2 for railway crossing (erection charges included in hdpe pipe erection charges) mtr 0 44.72 0.00 0 0 0.00 0 34 11 kv 3/c xlpe cable 185mm2 cable box no 985 727.00 1147.53 40 45901 29080.00 74981 11 kv 3/c xlpe cable 300mm2 cable box no 1100 727.00 1281.50 4 5126 2908.00 8034 35 hdpe pipe 160mm (pe 63) pn 4 for highway/railway crossing mtr 661 650.00 770.07 520 400433.8 338000.00 738434 36 11 kv la s/stn type 9 kv, 10 ka heavy duty no. 1900 52.00 2213.50 0 0.00 0 37 gi flat for t off bracing 900mm 50x6mm wt. 2.160 kg 38 wooden clamps/cleats nos. 69.45 25 80.91 116 9385.473 2900.00 12285 39 gi. angle 50x50x6mm kg. 86.447 0 100.71 100 10071.0755 0.00 10071 40 gi. channel of various sizes 100x50mm kg. 86.376 0 100.63 800 80502.432 0.00 80502 41 gi. channel 75x40x6mm kg. 87.792 0 102.28 200 20455.536 0.00 20456 42 11 kv 400 amps. go switch complete with handle, pipe & supporting channel. as per nigam’s tech. spec., relevant iss and latest amendments 9 mtr. pcc poles ht trivector dlms complaint meters (category a) with all acessories for complete installation as per tech.specs.no.csc 45/rev iii/dh/uh/p&d/2015 16 subject to change in parameters i.e voltage ratio 33kv/110v ,0.2 accuracy class, current ratio /1a . nos. 24549 1432.00 28599.59 1 28600.00 1432.00 30032.00 2 test terminal block. nos. 635 37.00 739.78 1 740.00 37.00 777.00 3 metallic meter box to house 1 no. of three ph meter with modem in accordance with approved design/ drawing of nigam, in let and outlet holes per cable, transparent glass cover for meter reading. nos. 545 67.00 634.93 1 635.00 67.00 702.00 4 33kv combined ct & pt units with jun. box comp. in all respect. nos. 107380 2300.00 125097.70 1 125098.00 2300.00 127398.00 5 u/a cu. control cable 10c x 2.5sqmm comp. with lugs for fitting/connectivity (both end). mtrs. 278.758 18.00 324.75 6 1949.00 108.00 2057.00 6 u/a cu. control cable 6c x 4sqmm comp. with lugs for fitting/connectivity (both end). mtrs. 260.45 16.00 303.42 6 1821.00 96.00 1917.00 7 acsr cond. 0.2sq.inch panther. mtrs. 176 8.39 205.04 36 7381.00 302.00 7683.00 8 pg clamps for panther conductor 9 c wedge connector for 0.2sqin acsr. nos. 1028 123.00 1197.62 6 7186.00 738.00 7924.00 10 gi flat 50x6mm (sail/tata) for earthing kgs 74.34 5.00 86.61 15 1299.00 75.00 1374.00 11 danger plate nos. 68 9.00 79.22 1 79.00 9.00 88.00 12 gi pipe 40 mm dia (b class) with clamp mtrs. 1901 0 2214.67 2.5 5537.00 0.00 5537.00 13 galvanized steel structure for combined 33 kv ct pt unit complete with gi nut bolt and washers (sizes 65x65x6mm=1.50 kg. sale and tata only, total weight 165 kg) nos. 18003 817.00 20973.50 1 20973.00 817.00 21790.00 14 construction of foundation for combined 33 kv ct pt unit as per nigam design and drawing (vcb 19) complete in all respect.(supply + erection ...

Dakshin Haryana Bijli Vitran Nigam Limited - Haryana

39571242 tender for site survey, planning, design, engineering, assembly manufacturing, testing, supply, loading, transportation, unloading, insurance, delivery at site, handling, storage, installation, testing, commissioning and documentation of all items/material required to complete the lrp works in the hisar no. i division (under hisar circle) which inter alia include replacement of lt bare conductor with lt armoured xlpe cable of various sizes, re conductoring of existing worn out lt line with new acsr conductor of various sizes in urban area, augmentation of existing 11 kv line with new acsr conductor / xlpe cable of various sizes, bifurcation of existing 11 kv feeders and installation of vcbs 1 pcc poles 9.0 m long. nos. 942 2500.00 412.50 2912.50 2743575.00 798.00 751716.00 3495291.00 2 pcc poles 9.0 m long. (for re conductoring of existing worn out lt line with new acsr conductor of various sizes) nos. 2277 2500.00 412.50 2912.50 6631762.50 379.05 863096.85 7494859.35 3 pcc poles 11.0 m long. nos. 1664 5343.00 881.60 6224.60 10357734.40 898.00 1494272.00 11852006.40 4 stay sets 8 long complete with x plat 460mm of angle 65x65x6 elbow & rod wt. 13.80 kg. set. 1626 1228.00 202.62 1430.62 2326188.12 299.00 486174.00 2812362.12 5 stay wire 7/8 swg kgs. 14886.300 99.12 16.35 115.47 1718921.06 0.00 0.00 1718921.06 6 gsl no.8 swg for (earthing & guarding) mtr. 153052 0.00 0.00 0.00 0.00 1.12 171418.24 171418.24 kgs. 19131.475 94.40 15.58 109.98 2104079.62 0.00 0.00 2104079.62 7a gi nuts bolts off sizes with washer kgs. 4962.650 84.00 13.86 97.86 485644.93 0.00 0.00 485644.93 part 1 bidding procedures and requirements 139 sr. no. description of material unit qty. of hisar no. i division (under hisar circle) unit supply rate including gst (inr) overhead charges i.e. 16.5% on supply part (incl. gst) total unit supply rate including gst and overhead charges total supply cost (inr) unit erection rate (inr) total erection cost (inr) total (supply + erection) cost (inr) 7b gi nuts bolts off sizes with washer (for re conductoring of existing worn out lt line with new acsr conductor of various sizes) kgs. 5690.525 84.00 13.86 97.86 556874.78 7.00 39833.68 596708.45 8 half clamps wt. 1.47 kg. hvpn drg. no. 2380 nos. 2033 156.00 25.74 181.74 369477.42 0.00 0.00 369477.42 9 full clamps wt.2.325 kg. hvpn drg. no. 2349 nos. 1626 247.00 40.76 287.76 467897.76 0.00 0.00 467897.76 10a lt insulator nos. 3766 10.00 1.65 11.65 43873.90 0.00 0.00 43873.90 10b lt insulator (for reconductoring of existing worn out lt line with new acsr conductor of various sizes) nos. 28453 10.00 1.65 11.65 331477.45 1.00 28453.00 359930.45 11 egg/guy insulator nos. 270 10.00 1.65 11.65 3145.50 0.00 0.00 3145.50 12a d straps nos. 3766 68.00 11.22 79.22 298342.52 0.00 0.00 298342.52 12b d straps (for reconductoring of existing worn out lt line with new acsr conductor of various sizes) nos. 28453 68.00 11.22 79.22 2254046.66 9.00 256077.00 2510123.66 13 wooden cleats (2holes) nos. 0 69.45 11.46 80.91 0.00 0.00 0.00 0.00 part 1 bidding procedures and requirements 140 sr. no. description of material unit qty. of hisar no. i division (under hisar circle) unit supply rate including gst (inr) overhead charges i.e. 16.5% on supply part (incl. gst) total unit supply rate including gst and overhead charges total supply cost (inr) unit erection rate (inr) total erection cost (inr) total (supply + erection) cost (inr) 14 4 core 120mm2 lt armoured xlpe cable kms. 0.000 644180.00 106289.70 750469.70 0.00 21130.00 0.00 0.00 15 4 core 95mm2 lt armoured xlpe cable kms. 0.000 394042.00 65016.93 459058.93 0.00 17610.00 0.00 0.00 16 4 core 50mm2 lt armoured xlpe cable kms. 0.000 239375.00 39496.88 278871.88 0.00 12300.00 0.00 0.00 17 4 core 25mm2 lt armoured xlpe cable kms. 0.000 144258.00 23802.57 168060.57 0.00 12300.00 0.00 0.00 18 3.5 core 120mm2 lt armoured xlpe cable kms. 0.000 449000.00 74085.00 523085.00 0.00 21130.00 0.00 0.00 19 3.5 core 95mm2 lt armoured xlpe cable kms. 0.000 400363.00 66059.90 466422.90 0.00 17610.00 0.00 0.00 20 3.5 core 50mm2 lt armoured xlpe cable kms. 0.000 245401.00 40491.17 285892.17 0.00 12300.00 0.00 0.00 21 1 core 120mm2 lt armoured xlpe cable kms. 0.000 169117.00 27904.31 197021.31 0.00 8455.85 0.00 0.00 22 1 core 95mm2 lt armoured xlpe cable kms. 103.344 105385.00 17388.53 122773.53 12687907.68 7830.00 809183.52 13497091.20 23 1 core 50mm2 lt armoured xlpe cable kms. 13.489 82315.00 13581.98 95896.98 1293554.36 5590.00 75403.51 1368957.87 24 1 core 25mm2 lt armoured xlpe cable kms. 0.000 52778.00 8708.37 61486.37 0.00 2880.00 0.00 0.00 part 1 bidding procedures and requirements 141 sr. no. description of material unit qty. of hisar no. i division (under hisar circle) unit supply rate including gst (inr) overhead charges i.e. 16.5% on supply part (incl. gst) total unit supply rate including gst and overhead charges total supply cost (inr) unit erection rate (inr) total erection cost (inr) total (supply + erection) cost (inr) 25 11 kv xlpe cable 3cx185mm2 kms. 0.000 1192638.00 196785.27 1389423.27 0.00 33540.00 0.00 0.00 26 11 kv xlpe cable 3cx95mm2 kms. 0.000 871349.00 143772.59 1015121.59 0.00 26830.00 0.00 0.00 27 11 kv xlpe cable 3cx50mm2 kms. 0.000 612948.00 101136.42 714084.42 0.00 22360.00 0.00 0.00 28 acsr dog conductor (100 sqmm) kms. 1133.124 86598.00 14288.67 100886.67 114317107.06 3350.00 3795965.40 118113072.46 29 acsr raccoon conductor (80 sqmm) kms. 0.000 63732.00 10515.78 74247.78 0.00 2520.00 0.00 0.00 30 insulated acsr raccoon conductor (80 sqmm) kms. 0.000 73732.00 12165.78 85897.78 0.00 2520.00 0.00 0.00 31 acsr rabbit conductor (50 sqmm) kms. 0.000 45611.00 7525.82 53136.82 0.00 2070.00 0.00 0.00 32 g.i. channel for wooden cleat (5 kg) 75x40x6mm. nos. 0 524.26 86.50 610.76 0.00 0.00 0.00 0.00 33 ss strap with adjustable screw (for clamping of armour for 25, 50, 95,120 mm2 & support gsl/jubliee clamp nos. 0 15.00 2.48 17.48 0.00 1.00 0.00 0.00 34 ms angle iron for bracing (600mm) 50x50x6mm wt. 2.70 kg. nos. 0 279.44 46.11 325.55 0.00 0.00 0.00 0.00 35 mid span joint (120sq mm). nos. 0 140.00 23.10 163.10 0.00 9.00 0.00 0.00 36 mid span joint (95sq mm). nos. 191 135.00 22.28 157.28 30040.48 8.00 1528.00 31568.48 37 mid span joint (70sq mm). nos. 0 127.00 20.96 147.96 0.00 7.50 0.00 0.00 38 mid span joint (50sq mm). nos. 25 123.00 20.30 143.30 3582.50 7.00 175.00 3757.50 39 mid span joint (25sq mm). nos. 0 118.00 19.47 137.47 0.00 7.00 0.00 0.00 40 gi pipe for earthing of dt 40mm dia 6 mtr long. nos. 749 1901.00 313.67 2214.67 1658787.83 320.32 239919.68 1898707.51 41 gi strip 25x6 9 mtr long 10.8 kg. nos. 749 1148.00 189.42 1337.42 1001727.58 82.00 61418.00 1063145.58 42 earth chemical (coal + salt 3.75 kg each). kgs. 1908.871 13.88 2.29 16.17 30866.44 0.00 0.00 30866.44 43 al. lugs offsize. (120 sqmm) nos. 0 11.90 1.96 13.86 0.00 5.00 0.00 0.00 44 al. lugs offsize. (95 sqmm) nos. 0 10.00 1.65 11.65 0.00 5.00 0.00 0.00 45 insulating piercing connector (50 150 sq.mm) nos. 7370 85.00 14.03 99.03 729851.10 6.00 44220.00 774071.10 part 1 bidding procedures and requirements 143 sr. no. description of material unit qty. of hisar no. i division (under hisar circle) unit supply rate including gst (inr) overhead charges i.e. 16.5% on supply part (incl. gst) total unit supply rate including gst and overhead charges total supply cost (inr) unit erection rate (inr) total erection cost (inr) total (supply + erection) cost (inr) 46 insulating piercing connector (16 95/4 50 sq.mm) nos. 0 72.00 11.88 83.88 0.00 5.00 0.00 0.00 47 eye screw bolts 9”x5/8 wt. 0.483 kg. (g.i) nos. 941 41.00 6.77 47.77 44951.57 0.00 0.00 44951.57 48 insulation mastic tape (2inc x 10 feet). nos. 620 793.00 130.85 923.85 572787.00 48.00 29760.00 602547.00 49 11kv top hamper g.i. weight 1.480 kg nos. 1048 157.00 25.91 182.91 191689.68 0.00 191689.68 50 11kv polymeric pin insulator with pin nos. 3696 189.00 31.19 220.19 813822.24 0.00 813822.24 51 11 kv polymeric disc insulator (45 kn.tounge & clevis type) with fitting nos. 1109 116.00 19.14 135.14 149870.26 0.00 149870.26 52 disc fitting t&c type nos. 0 87.00 14.36 101.36 0.00 0.00 0.00 0.00 53 pg clamp nos. 1109 40.00 6.60 46.60 51679.40 0.00 51679.40 54 v shape x arm g.i. 100x50 mm ( ismc 100) weight 13.2 kg nos. 1048 1365.00 225.23 1590.23 1666561.04 0.00 1666561.04 55 11 kv disc insulator (t&c type) for stay nos. 1356 116.00 19.14 135.14 183249.84 0.00 183249.84 part 1 bidding procedures and requirements 144 sr. no. description of material unit qty. of hisar no. i division (under hisar circle) unit supply rate including gst (inr) overhead charges i.e. 16.5% on supply part (incl. gst) total unit supply rate including gst and overhead charges total supply cost (inr) unit erection rate (inr) total erection cost (inr) total (supply + erection) cost (inr) 56 earthing rod weight 6.175 kg nos. 124 434.00 71.61 505.61 62695.64 151.00 18724.00 81419.64 57 m.s. channel (x arm) 100x50x6mm 2200mm (for h pole) g.i. wt. 21.032 kg nos. 740 2175.00 358.88 2533.88 1875071.20 0.00 1875071.20 58 m.s.angle iron 50x50x6mm 2400mm (for earth wire) g.i. wt.10.80 kg nos. 432 1118.00 184.47 1302.47 562667.04 0.00 562667.04 59 m.s. angle 50x50x6mm 2860mm (bracing h. pole) g.i. wt. 12.87 kg nos. 493 1332.00 219.78 1551.78 765027.54 0.00 765027.54 60 m.s angle 50x50x6mm 2200mm (belting for hpole) g.i. wt. 9.90 kg nos. 493 1025.00 169.13 1194.13 588706.09 0.00 588706.09 61 barbed wire kgs. 1478.400 97.94 16.16 114.10 168685.44 0.00 168685.44 62 danger plate(enamelled with clamp) nos. 1664 68.00 11.22 79.22 131822.08 0.00 131822.08 63 number plate with clamp nos. 1294 68.00 11.22 79.22 102510.68 0.00 102510.68 64 phase plate for each phase set of 3 (on each h pole) set. 308 57.00 9.41 66.41 20454.28 0.00 20454.28 65 gi angle 50x50x6 mm 1400 mm long kgs. 7022.400 86.45 14.26 100.71 707225.90 0.00 707225.90 66 knee bracing (gi flat 50x6mm) kgs. 4928.000 89.21 14.72 103.93 512167.04 0.00 512167.04 part 1 bidding procedures and requirements 145 sr. no. description of material unit qty. of hisar no. i division (under hisar circle) unit supply rate including gst (inr) overhead charges i.e. 16.5% on supply part (incl. gst) total unit supply rate including gst and overhead charges total supply cost (inr) unit erection rate (inr) total erection cost (inr) total (supply + erection) cost (inr) 67 g.i. channel t off 100x50x6 mm 1600mm). wt. 15.296kg nos. 0 1582.00 261.03 1843.03 0.00 0.00 0.00 0.00 68 ht 11kv xlpe 3c x185 sq. mm outdoor heat shrinkable termination kit nos. 0 985.00 162.53 1147.53 0.00 98.50 0.00 0.00 69 ht 11kv xlpe 3c x95 sq. mm outdoor heat shrinkable termination kit nos. 0 825.00 136.13 961.13 0.00 82.50 0.00 0.00 70 ht 11kv xlpe 3c x50 sq. mm outdoor heat shrinkable termination kit nos. 0 775.00 127.88 902.88 0.00 77.50 0.00 0.00 71 suspension clamp assembly with eye hook nos. 0 425.00 70.13 495.13 0.00 0.00 0.00 0.00 72 dead end clamp assembly with eye hook set. 0 244.00 40.26 284.26 0.00 0.00 0.00 0.00 73 u bolt for suspension fittings wt 0.600 kg (gi) nos. 0 50.00 8.25 58.25 0.00 0.00 0.00 0.00 74 ss cable ties releaseable arc for dia 250mm nos. 0 6.00 0.99 6.99 0.00 0.39 0.00 0.00 75 ss cable ties releaseable arc for dia 250mm (for augmentation of existing 11 kv line with overhead xlpe cable of various sizes) nos. 0 6.00 0.99 6.99 0.00 0.00 0.00 0.00 76 gss wire (earth wire) 7/14 swg 2.24mm mtr. 0 0.00 0.00 0.00 1.62 0.00 0.00 kgs. 0.000 103.84 17.13 120.97 0.00 0.00 0.00 77 11kv vcb panel (outgoing 25ka , 475mv refnicng capacity , 24v dc operated indoor type with set of ct/,pts, kwh meter, relays instruments etc complete in all respets conforming to all nigams specifications iss (400a) set. 0 332000.00 54780.00 386780.00 0.00 6708.00 0.00 0.00 78 11kv vcb panel (outgoing), v dc operated indoor type with set of ct/,pts, kwh meter, relays instruments etc complete in all respets (1250a) set. 0 264083.00 43573.70 307656.70 0.00 6708.00 0.00 0.00 79 un armoured copper control cable 10c x 2.5 mm2 mtr. 0 278.76 46.00 324.75 0.00 18.00 0.00 0.00 80 gi flat 50 x 6 mm kgs. 0.000 89.21 14.72 103.93 0.00 5.00 0.00 0.00 81 3/cx185mm sq. i/d heat shrinkable cable box for o/g feeders nos. 0 840.00 138.60 978.60 0.00 84.00 0.00 0.00 part 1 bidding procedures and requirements 147 sr. no. description of material unit qty. of hisar no. i division (under hisar circle) unit supply rate including gst (inr) overhead charges i.e. 16.5% on supply part (incl. gst) total unit supply rate including gst and overhead charges total supply cost (inr) unit erection rate (inr) total erection cost (inr) total (supply + erection) cost (inr) 82 signboard (as per clause 1.7 of sbd part 2 – sow) actual qty. and supply / erection rates will be circulated separately nos. total 1 171618110.62 9167337.88 180785448.49 details of materials (approx.) to be dismantled 1 poles (off sizes) nos. 860 0.00 0.00 0.00 0.00 189.53 162995.80 162995.80 2 old acsr conductor (off sizes) km. 763.548 0.00 0.00 0.00 0.00 615.00 469582.02 469582.02 3 steel items kg. 7297.860 0.00 0.00 0.00 0.00 2.50 18244.65 18244.65 4 lt cable (off sizes) km. 0.270 0.00 0.00 0.00 0.00 6150.00 1660.50 1660.50 5 ht cable (off sizes) km. 0.000 0.00 0.00 0.00 0.00 11180.00 0.00 0.00 total 2 0.00 652482.97 652482.97 grand total (total 1 + total 2) 171618110.62 9819820.85 181437931.46...

Haryana Vidyut Prasaran Nigam Limited - Haryana

39489283 bids are invited for dead end fittings for earth wire 72.5mm (q3) , ss hw fitting for acsr single zebra conductor (q3) , st hw bolted type fitting for acsr twin zebra conductor (q3) , spacer for 0.4 0.4sq inch acsr conductor (q3) , pg clamp for 0.5 0.5sq inch acsr conductor (q3) , st hw bolted type fitting for acsr triple zebra conductor (q3) , ss hw bolted type fitting for aac twin tarantulla conductor (q3) , spacer for aac double tarantulla conductor (q3) , st hw compression type fitting for acsr single zebra conductor (q3) , ss hw fitting for 0.4 0.4sq inch acsr twin conductor (q3) , st hw bolted type fitting for acsr single zebra conductor (q3) , st hw bolted type fitting for aac twin tarantulla conductor (q3) mse total quantity : 4988...

Indian Army - Haryana

39342516 bids are invited for ssl spare parts hyd oil temp gauge , water temp gauge , work light switch , beacon light switch , dual indicator bty heater , dual indicator water temp , fuel gauge , 4 way ignition switch , fan , positive bty cable , negative bty cable , direction indicator light , earth wire , head light , auxilary cable , hydraulic filter , flexible hose clip , air filter element inner , air filter element outer , arm cyl seal kit , cabin cyl seal kit , rotating cyl seal kit , lifting cyl joint kit , swinging arm cyl seal kit , bucket cyl seal kit , decal set , chassis harness , cabin harness total quantity : 36...

Management Development Institute - Haryana

39294949 tender for providing services for electrical equipment installation and repair & maintenance at management development institute gurgaon 1 supply of following sizes copper wire, pvc insulated, single core make havells/finolex rate only 1 a 1.5 mm mtr 1 b 2.5 mm mtr. 1 c 4 mm mtr 1 d 6 mm mtr 1 e 10 mm mtr 1 f 16 mm mtr 1 g 25 mm mtr 1 2 supplying of following sizes of 1.1 kv grade multicore aluminum conductor xlpe insulated armored cable conforming to is:7098, make havells/finolex/kei rate only a 2 c x 10 sq.mm mtr 1 b 4 c x 10 sq.mm mtr. 1 c 4 c x 16 sq.mm mtr 1 d 4 c x 25 sq.mm mtr 1 e 3.5 c x 35 sq.mm mtr 1 f 3.5 c x 35 sq.mm mtr 1 g 3.5 c x 70 sq.mm mtr 1 3 labour charges for the 5 amps light/fan/socket wiring complete job without material. nos 1 4 labour charges for the 15 amps power socket wiring complete job without material. nos 1 5 installation of tube light 40watt/20watt in room up to height 10’ 15’ (labour charge) nos 1 6 installation of fans 48”/56” (labour charges) nos 1 7 installation of distribution board wiring complete job without material (labour charges) nos 1 8 providing/fixing 5 amps light point with pvc conduit/channel poly pack/dip copper wire 1.5 mm and earth wire, switch 5 amps anchor, socket 5 amps anchor, wooden m.s. board, hylem sheet complete up to 5 meter length with all materials labour nos 1 9 providing/fixing 15 amps power points up to 5 meter length with 2.5 mm copper wire with earth wire, 15 amps switch and socket of anchor make, ms/wooden board, hylem sheet pvc channel/conduit pipe heavy duty poly pack/dip plast with all materials & labour nos 1 10 repair of tube lights up to 25’ 30’ height without material (labour charges) nos 1 11 laying of pvc armored cable in trench 3’ depth, providing sand 3” thick above cable and brick protection and refilling of trench complete job (labour charges) only. rate only a 10 mm2 meters 1 b 25 mm2 meters 1 c 35 mm2 meters 1 d 50 mm2 meters 1 e 70 mm2 meters 1 f 95 mm2 meters 1 g 120 mm2 meters 1 h 150 mm2 meters 1 i 185 mm2 meters 1 j 240 mm2 meters 1 k 300 mm2 meters 1 l 400 mm2 meters 1 12 rewinding charges for ceiling fans (size 48/56’’) nos 1 13 labour charges for the repair/service of ceiling fan/wall mounted fan(excluding grease, bearing, repairing etc) nos 1 14 supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of pvc insulated and pvc sheathed / xlpe aluminum conductor cable of 1.1 kv grade as required complete job (make rechem/3m) rate only a 3.5 c x 50 sq. mm to 95 sq.mm nos. 1 b 3.5 c x 120 sq. mm to 185 sq.mm nos. 1 c 3.5 c x 240 sq. mm to 300 sq.mm nos. 1 d 3.5 c x 400 sq.mm nos. 1 15 supplying and making straight through joint with heat shrinkable kit sleeve only with chain system of pvc insulated and pvc sheathed / xlpe aluminum conductor cable of 1.1 kv grade as required complete job with installation charges. rate only a 3.5 c x 50 sq. mm to 95 sq.mm nos. 1 b 3.5 c x 120 sq. mm to 185 sq.mm nos. 1 c 3.5 c x 240 sq. mm to 300 sq.mm nos. 1 d 3.5 c x 400 sq.mm nos. 1 16 providing fault locator machine for terrace the fault indoor/outdoor in campus for lt/ht cable complete job nos. 1...

Indian Army - Haryana

39122003 bids are invited for ssl spare parts hyd oil temp gauge , water temp gauge , work light switch , becon light switch , dual indicator heater , dual indicator water temp , fuel gauge , 4 way ignition switch , fan , positive bty cable , negative bty cable , direction indicator light , earth wire , head light , auxiliary cable , hydrualic filter , flexible hose clip , air filter element inner , air filter element outer , arm cyl seal kit , cabin lift cyl seal kit , rotating cyl seal kit , lifting cyl seal kit , swinging arm cyl seal joint kit , bucket cyl seal kit , decal set , chassis harness , cabin harness total quantity : 36...

Bhakra Beas Management Board - Haryana

39020819 bids are invited for civil works 1 earth work in excavation of foundations of bridges culverts, buildings including handling of material with a combined lead of 15 metres dressing of bed and sides stacking the excavated soil from the edge of excavation and subsequent filling around a. for ordinary gravel soil involving pick work l_r ref no. 6.7 _a of pb csr2020 civil worls 2 cement concrete 1_5_10 with stone aggregate 40mm gauge ii mixing by mechanical means using concrete mixer volumetric type l_r ref no 10.9_b_ii of pb csr2020 civil works 3 cement concrete 1_3_6 with stone blast or shimgle mixing by mechanical means using concrete mixer volumetric type t_r ref no 10.12_a_ii of pb csr2020 civil works 4 cement concrete 1_8_16 with stone aggregate 40mm gauge mixing by mechanical means using concretemixer volumetric type 10.6_b_ii civil works 5 cold twisted deformed ribbed _ tor steel bar bars fe 500 grade as per is 1786_2008 for rcc works where not included in the complete rate of rcc including bending and placing in position in complete t_r ref no 18.18 of pb csr2020 civil works 6 cold twisted deformed (ribbed_ tor steel) bars (fe 415 grade as per is 1786_2008) for rcc works, where not including in the complete rate of rcc including binding and bending and placing in position complete ref no 18.17 of pb csr2020 civil works 7 shuttering for faces of concrete foundations and foundation beam and plinth beam (vertical or battering ) ref no 9.1 of pb csr2020 civil works 8 centering and shuttering for columns (square or rectangular or polygonal in plain) ref no 9.4 of pb csr2020 civil works 9 reinforced cement concrete m20 mechanically batch mixed using batch type concrete mixer as by is1791 and vibrated by needle vibrate but excluding steel reinforcement centring and shuttering in foundation and plinth. ref n. 10.15 of pb csr2020 plusextra for pumping charges of batch mix concrete _ready mix conrete work (rmc) ref pb csr 2020 item no 10.46. zon a t_r plusextra for using admixture in designed mix concrete ref pb csr 2020 item no 10.50. zonea (t_r) plusextra for carriage of rmc/batch mixed concrete with transit mixture beyond 1st km ref pb csr 2020 item no. 10.47 zonea (t_r) civil works 10 first class burnt brick laid in cement sand mortar 1_6 in foundation and plinth ref pb csr 2020 item 11.3i civil work 11 20mm thick cement plaster 1_4 in two coat work ref pb csr 2020 item 15.20 civil work 12 providing weep holes in brick masonry/plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia pvc pipe, extending through the full width of the structure with slope of 1v _20h towards drawing foce. complete as per drawing and technicalspecifications ref pb csr 2020 item 21.35 civil works 13 labour ns item for 1. fixing, leveling , centering, alignment and setting of stub template and dismantling of stub template complete in all respect 2. marking of peg tower location3. marking of pits of tower foundation4. watch and ward for stub, stub template and former boxes for stub foundations 5. transportation of t&p, stub, stub template, former boxes, vibrator etc. at work site muffing 1 reinforced cement concrete m20mechanically batch mixed using batch type concrete mixer as per is1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth ref pb csr 2020 item no. 10.15 muffing 2 cold twisted deformed (ribbed_tor steel) bars (fe 500 grade as per is 1786_2008) , for r.c.c works, where not including in the complete rate ofrcc including bending and binding placing in position complete. (ref. pb. csr2020, item no 18.18) muffing 3 centering and shuttering for columns (circular or curved in plain) ref pb csr 2020 item no. 9.5 muffing 4 capping provided with bitumen at the stub n_s tower material 1 220 kv d_c krr design md type tower weighing around 24773.07 kg including 16094.64 of ht plus 8678.43 ms tower material 2 stub for krr design md type tower 2621.28 kg including 1901.28 of ht plus 720 ms tower material 3 plus 6 mtr extn. for krr design weighing around 5214.42 kg including 2811.35 of ht plus 2403.07 ms tower material 4 stub template for krr design md type tower with 6 mtr extension wt 1230.92 kg approx tower material 5 220 kv d_c krr design nmd type tower including 15 mtr extension weighing around 39207.26 including 23315.38 of ht plus 15891.88 ms tower material 6 stub of nmd type tower weighing around 2621.28 kg including 1901.28 of ht plus 720 ms tower material 7 220 kv d_c dd (tata) design type tower 9213.57 kg per tower including 3691.1 kg of ht and 5522.47 kg of ms steel tower material 8 stub of dd type normal tower wt 396.94 kg ms 23.10 kg. plus ht 373.84 kg tower material 9 stub of dd type plus 6 mtr extension wt 453.36 kg. ms 23.10 kg. plus ht 430.26 kg. tower material 10 stub of dd type plus 15 mtr extension tower wt 428.52 kg ms23.20 kg. plus ht 405.32 kg tower material 11 tata type tower body +6m extn. only wt. 2728.80 kg ms2047.40kg. plus ht681.40 kg tower material 12 tata type tower body plus15m extn only wt. 9390.80 kg.ms7805.00kg plus ht 1585.8kg climbing device tower material 13 weight of stub template required 1no for dd type tower 1075.50kg tower material 14 gi nut and bolts of various sizes tower material 15 g.i spring washers & plain washers off size tower material 16 double tension hardware fitttings suitable for goat conductor tower material 17 dead ending cone clamp for goat conductor tower material 18 acsr conductor 0.3sq inch goat tower material 19 earth wire 7_3.15 mm tower material 20 straight joint for earth wire 7_3.15 mm tower material 21 vibration damper for 7_3.15 mm earth wire tower material 22 earth wire tension fitting tower material 23 earthing complete set including hardware fitting as per specification tower material 24 straight joint for goat conductor tower material 25 220 kv 160kn polymer string insulator. tower material 26 single tension h_w compression type fitting for 0.3sq inch goat conductor tower material 27 vibration damper for 0.3sq inch goat conductor tower material 28 phase plate with nut and bolt set of 3 tower material 29 number plate tower material 30 danger plate tower material 31 circuit plate tower material 32 bird guard tower material 33 anti climbing device (acd) with concertina wire tower material 34 ladder/step bolt with washer tower material 35 span marker/globules day marking spheres tower material 36 form box prototype 1 charges for prototype of tower at fabricators premises prototype 2 preparing of as build drawing from the tower erection drawings of towers erection 1 cost of erection 5 nos 3 no. dd type towers and 2 no. md type towers including extensions tower and allied fitting along with complete stacking of material erection 2 cost for stringing and sagging of conductor and earthwire including measurements, cutting etc. along with installation of globules complete in all respects. erection 3 cost of dismantlement of 4 no existing towers and allied fitting including transportation of all dismantled material from site to bbmb ballabgarh store erection 4 tack welding upto first floor total quantity : 17841...

Indian Army - Haryana

38810075 bids are invited for ssl spare parts head light , cabin bush rear , bushes cabin lift cyl front , auxiliary cable , pc side sheet rh , pc side sheet lh , fan , front door glass , chasiss harness , positive bty cable , negative bty cable , earth wire , hyd filter , rubber bush , cabin harness , fan switch , flexible hose clip , stablizing cyl joint kit , bearing 60134ks , radiator mtg pad top , bty clamping bracket , arm cyl seal kit , bucket cyl seal kit , stud , lock nut , ball joint , fuel sensor unit , quick coupling male , quicl coupling female , lifting cyl joint kit total quantity : 47...

Haryana Vidyut Prasaran Nigam Limited - Haryana

38800544 erection, testing and commissioning of equipments for left out work for construction of 220kv ( gis ) s / stn. roj ka meo. ( a risk purchase case of contract no. hdp 2394 / rec 241 / xen / wb dated 05.03.2019 awarded to m / s ike electric jv m / s deesan agro tech 1 loading and unloading of 02 no. 160 mva, 220/66kv t/f along with erection of 1 no. 100mva, 220/33kv tf and 2 no. 160 mva, 220/66kv t/f with its accessories complete in all respect. 2 erection of mk hv/lv side including loading, unloading charges complete in all respect. 3 erection of 66kv t/f la including loading,unloading charges complete in all respect. (1set=3 no.) 4 erection of 220kv t/f la including loading, unloading charges complete in all respect (1set=3 no.). 5 erection of bus bar including loading, unloading transportation complete in all respect. 6 erection of 66kv/33kv and 220kv nct including loading,unloading charges complete in all respect. 7 providing earth wire complete in all respect. 8 drilling of bore of 40 mm dia. for 30 no bore for depth of 100 feet eachincluding supply of jindal make 40 mm pipe and fittings/socket complete in all respect . 9 loading of gi pipe in the 30 no. bores each of 100 feet after welding with ms flat & compaction around the pipe with mixure coal salt & soil for 30 x 100 = 3000 feet complete in all respect. 10 filling of t/f oil and dehydration of oil by hiring dehydration set complete in all respect. 11 erection, testing and commsisioning of 14 no. 33kv gis modules under supervision of authorised representative of oem or from its authorized channel partner complete in all respect. 12 laying of 220kv xlpe copper cable (1cx 400mm2) to connect 220kv side of 100mva tf with gis including excavation,arranging and spreading of sand, laying of cables, bricks and back filling complete in all respect. 13 laying of 220kv xlpe copper cable (1cx 500mm2) to connect 220kv side of 100mva tf with gis including excavation,arranging and spreading of sand, laying of cables, bricks and back filling complete in all respect. 14 laying of 220kv xlpe copper cable (1cx 1000mm2) to connect 220kv side of 100mva tf with gis including excavation,arranging and spreading of sand,laying of cables, bricks and back filling complete in all respect. 15 laying of 650/1100volts 3.5 core 240mmsq aluminium power cable from aux. t/f to acdb with gis including excavation,arranging and spreading of sand,laying of cables, bricks and back filling complete in all respect. 16 laying of 650/1100volts 3.5 core 70mmsq aluminium power cable for oil filtration set with gis including excavation,arranging and spreading of sand,laying of cables, bricks and back filling complete in all respect. 17 laying of 650/1100volt 4 core 16mmsq armoured copper power cable for mldb etc and other cableincluding excavation,arranging and spreading of sand,laying of cables, bricks and back filling complete in all respect. 18 laying of 1core 50sq mm cables for battery charger to batteryincluding excavation,arranging and spreading of sand,laying of cables, bricks and back filling complete in all respect. 19 laying of 66kv xlpe copper cable (1cx 1000mm2) to connect 66kv side of 220/66kv tf with gis with excavation, arranging and spreading of sand,laying of cables, bricks and back filling complete in all respect. 20 laying of 66kv xlpe copper cable (1cx 800mm2) to connect for each line feeder bay with excavation,arranging and spreading of sand,laying of cables, bricks and back filling complete in all respect. 21 laying of 33kv ht copper cable (1cx 1000mm2) xlpe to connect for each line feeder bay with excavation,arranging and spreading of sand,laying of cables, bricks and back filling complete in all respect. 22 laying of 33kv ht copper cable (3cx 300mm2) xlpe to connect for each line feeder bay with excavation,arranging and spreading of sand,laying of cables, bricks and back filling complete in all respect. 23 laying of 33kv ht copper cable (3cx 95mm2) xlpe to connect for each line feeder bay with excavation,arranging and spreading of sand,laying of cables, bricks and back filling complete in all respect. 24 supply and erection of eot crane as per clause 2.10.7 section 1 and clause 29.0 of gis specification and section 7 of switchyard (10t and 5t each) from the hvpnl approved vendor in line with dimensions of respective gis hall complete in all respect. 25 supply and erection of ahu of 220kv & 66kv gis building hall from the hvpnl approved vendor in line with dimensions of respective gis hall complete in all respect. 26 erection, testing and commissioning of 220kv and 66kv gis modules under supervision of authorised representative of oem or from its authorized channel partner complete in all respect. i) 245kv single 3 phase or 3 single phase tf,line and bus coupler bays (1 set = 1 bay module). ii) 72.5kv single 3 phase or 3 single phase tf,line and bus coupler bays (1 set = 1 bay module). 27 installation of termination kits of 220kv 1cx500 sqmm at both ends under supervision of authorised representative of oem or from its authorized channel partner complete in all respect. 28 installation of termination kits of 220kv 1cx400 sqmm at both ends under supervision of authorised representative of oem or from its authorized channel partner complete in all respect 29 installation of termination kits of 220kv 1cx1000 sqmm at both ends under supervision of authorised representative of oem or from its authorized channel partner complete in all respect 30 installation of termination kits of 66kv 1cx1000 sqmm at both ends under supervision of authorised representative of oem or from its authorized channel partner complete in all respect. 31 installation of termination kits of 66kv 1cx800 sqmm at both ends under supervision of authorised representative of oem or from its authorized channel partner complete in all respect. 32 installation of termination kits of 33kv 1cx100 sqmm at both ends under supervision of oem complete in all respect. 33 installation of termination kits of 33kv 3cx300 sqmm at both ends under supervision of authorised representative of oem or from its authorized channel partner complete in all respect. 34 installation of termination kits of 33kv 3cx95 sqmm at both ends under supervision of authorised representative of oem or from its authorized channel partner complete in all respect. 35 erection of 220kv las on line bays complete in all respect ( 1set= 3 no.) 36 erection of 33kv las on line bays complete in all respect ( 1set= 3 no.). 37 erection of 66kv cvt including transportation, crane charges complete in all respect. 38 erection of 220kv cvt including transportation, crane charges complete in all respect. 39 erection of 220kv c&r panel including transportation, crane charges complete in all respect. 40 erection of 66kv c&r panel including transportation, crane charges complete in all respect. 41 configurations of 220kv and 66kv c&r panel and relays of ge/alsotm make and confguration of 33kv vcb bays module from oem or its authorized channel partner complete in all respect. 42 configuration of sas and scada setup completeincluding communication with sldc from oem or its authorized channel partner complete in all respect. (for all bays). 43 providing y shape jumpers as per site requirement. 44 erection of wave trap complete in all respect 45 erection of 220kv dcdb complete in all respect. 46 erection of 415v acdb complete in all respect 47 erection of 220v, 200ah battery complete in all respect 48 erection of 48v, 300ah battery complete in all respect 49 erection of battery charger complete in all respect 50 erection of fire fighting equipment complete in all respect 51 laying of earth mat using ms rod 40mm dia including supply of ms rod 40m dia as per hvpnl techncial specifications, loading of steel from any location & unloading at work site,excavation and backfilling, welding, jointing,painting with red oxide and providing bitumen at joints and connecting to the bottom of all equipments, structures,junction boxes. 52 fabrication and connect risers from earth mat to structures, equipments, mk, electrical panels,plcc panels,fencing post etc. with supply of ms flats having size 75*12mm and 50*6mm 53 supply of ms rod, galvanized ms flats of size 75*12mm and 50*6mm required for earthing and laying earth mat of complete sub station as per hvpnl technical specifications. 54 un treated earth pits including installation of 40 mm dia rod electrode, disconnecting links, and all required materials and rcc collar/ chambers with bricks, cement mortar 1:4 and completion of related civil works as specified for lms, las, carrier couplings, cts, pts, isolators, breakers, power t/fs and cvts. (cost of rcc collar included) (4p/no.) total bores= 44 including supply of gi pipe of jindal make , coal, salt etc. 55 soil resistivity and earth resistance testing and preparation of earthmat design. 56 erection of substation station transformer including transformer,crane charges complete in all respect. 57 erection of substation steel structure including loading, unloading charges complete in all respect. 58 erection charges of 500kva dg set with accessories including transportation, crane charges complete in all respect. 59 erection charges for 10 mvar, 33kv capacitor bank complete in all respect. 60 laying of unarmoured and armoured control cable including transportation, laying, cleating, termination, preparation of cable schedule and wiring of substation cpmplete in all respect. 61 erection of plccincluding testing and commission ing from oem complete in all respect. 62 installation and erection of high wall split ac in control room 63 erection of yard light complete in all respect. 64 hiring charges of gas cutter with lpg and oxygen cylinder and operator complete in all respect 65 hiring charges of welding set with operator complete in all respect 66 transportation of material from hvnpl d/stores to site by hiring 7 ton truck.hiring of low bed trailor for transportation of power transformer (if required). total =130 trip with an average trip of 500km (to and fro). 67 petty items like ferrule, cable tray, thimbles off size, glands, cable ties, pvc pipe/elbow etc to complete the wiring and other allied works ...

Urban Local Bodies - Haryana

38683693 estimate for construction of stores in the premises of nagar nigam at hisar 1. [10.1]providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. 110.54 sqm 2. [10.100.2]cement concrete 1:8:16 flooring 2. cement concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. 87.54 cum 3. [10.16]providing and laying cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. 87.56 cum 4. [10.37.1]providing and fixing of kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick 16.74 sqm 5. [10.63.2]providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. size of tile 600x600 mm 110.54 sqm 6. [10.67.2]providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 2. size of tile 600x600 mm 11.85 sqm 7. [10.70.2]extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of engineer incharge. 2. size of tile 600x600 mm 155.01 sqm 8. [11.26.1]pointing on tile brick work with cement mortar 1:3 (1 cement : 3 fine sand): 1. flush/ ruled/ struck or weathered pointing 155.01 sqm 9. [11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) 10. [11.60]providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 637.37 sqm 11. [11.65.1]distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer`s specification. 1. two or more coats on new work 515.46 sqm 12. [11.67.1]applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 1. water thinnable cement primer 637.37 sqm 13. [11.68.3]applying priming coat: 3. with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 27.82 sqm 14. [11.77]applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc. 16.72 sqm 15. [11.78]painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. 54.64 sqm 16. [11.95.1]finishing walls with acrylic smooth exterior paint of required shade : 1. new work (two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 314.25 sqm 17. [12.10.2.1]providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including isi marked m.s. pressed butt hinges bright finished of required size with necessary screws. 2.1. kiln seasoned and chemically treated hollock wood 35 mm thick 8.36 sqm 18. [12.102.2]providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 100 mm 32.00 each 19. [12.19.1.1.2]providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 1.1.2. 35 mm thick shutters with isi marked m.s. pressed butt hinges bright finished of required size kiln seasoned and chemically treated hollock wood 8.36 sqm 20. [12.36.1]providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1. 35 mm thick including isi marked stainless steel butt hinges with necessary screws 18.21 sqm 21. [12.50.1]providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coat with approved steel primer all complete. 1. fixed to steel windows by welding 187.20 kg. 22. [12.66.3]providing and fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete : 3. 150x10 mm 23. [12.98.1]providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm 8.00 each 24. [13.3.1.1]providing and fixing pressed steel door frames conforming to is: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including m.s. pressed butt hinges 2.5 mm thick with mortar guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre treatment of the surface as directed by engineer in charge: 1.1. profile b fixing with adjustable lugs with split end tail to each jamb 43.89 metre 25. [13.3.3.1]providing and fixing pressed steel door frames conforming to is: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including m.s. pressed butt hinges 2.5 mm thick with mortar guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre treatment of the surface as directed by engineer in charge: 3.1. profile e fixing with adjustable lugs with split end tail to each jamb 268.00 metre 26. [13.30.1]steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 1. hot finished welded type tubes 1014.00 kg. 27. [13.37.2]supplying and fixing rolling shutters of approved make, made of required size m.s. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to is: 4454 part 1 and m.s. top cover of required thickness for rolling shutters. 2. 80x1.20 mm m.s. laths with 1.20 mm thick top cover 17.84 sqm 28. [20.71.2]supply, erection, testing of ceiling fans is marked (as per is code 374) with suitable gi pipe complete in all respects complete as per directions of engineer in charge 2. 56 (1400mm) 18.00 each 29. [23.22.1.3]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 1.3. supply and erection of modular case circuit breaker single pole/4 pole on existing wall/pedestal/panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the engineerin charge of the work. triple pole mccb 16 to 100 amp, 25 ka 2.00 each 30. [23.22.2.1]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 2.1. mccb enclosure made of sheet steel suitable for mounting mccb of following ratings mccb up to 125 a fp 31. [23.22.4.3]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 4.3. supply and erection of double door sheet steel enclosure distribution board suitable for mcbs and elcbs etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the engineer in charge of the work. spn db double door 12 way ( 2 incoming and 10 outgoing) 1.00 each 32. [23.22.4.5]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 4.5. supply and erection of double door sheet steel enclosure distribution board suitable for mcbs and elcbs etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the engineer in charge of the work. tpn db horizontal type double door 4 way ( 8 incoming and 3phase*4 outgoing) 2.00 each 33. [23.22.5.1]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 5.1. supply and erection of miniature circuit breaker 240/415 v in the existing distribution board including making necessary connections: 6 amp. to 32 amp single pole 20.00 each 34. [23.22.5.6]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 5.6. supply and erection of miniature circuit breaker 240/415 v in the existing distribution board including making necessary connections: 40 amp to 63 amp. mcbs triple pole 2.00 each 35. [23.22.7]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 7. supply and erection of blanking sheet in existing distribution board. 57.00 each 36. [23.23.2.1]miscellaneous 2.1. supply of gi pipe (bclass) for suspension rod of ceiling fan including threading if required. 15 mm dia 10.00 metre 37. [23.4.1.1]copper wiring with modular switches in pvc conduit (surface/recess) 1.1. wiring for light/fan/call bell point with modular type switch/socket and gi box, modular type face plate etc in 1.5 sqmm frls pvc insulated copper conductor cable in 1.6 mm thick pvc conduit pipe. group a 70.00 each 38. [23.4.4.1]copper wiring with modular switches in pvc conduit (surface/recess) 4.1. wiring in pvc conduit system for 3 pin 5amp. plug point by using 2 no 1.5 sqmm frls copper wire and 1 no 1.5 sqmm frls copper wire , including providing 1 no 5/6 amp 3/5 pin modular type socket and 1 no 5/6 amp modular type switch required gi box ,modular face plate etc complete as required group a 15.00 each 39. [23.4.5.1]copper wiring with modular switches in pvc conduit (surface/recess) 5.1. wiring in pvc conduit system for 3 pin 15amp. plug point by using 2 no 4 sqmm frls copper wire and 1 no 4 sqmm frls copper wire for earthling , including providing 1 no 15/16 amp 3/6 pin modular socket and 1 no 15/16 amp modular switch required gi box , modular face plate etc complete as required group a 15.00 each 40. [23.5.6.1]copper wiring in existing pvc/ms conduit pipe surface/recessed for electrical points 6.1. wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire pvc insulated copper conductor cable 1100 volts grade in existing ms/pvc conduit etc as required. 1 run of size 1.50 sqmm(1/1.40mm)...

Translational Health Science And Technology Institute - Haryana

38289248 tender for electrical work in cdsa, first floor ooc building under thsti, ncr biotech science cluster faridabad 1. wiring for circuit/ submain wiring along with earth wire with the 2 x 6 sq. mm + 1 x 4.0 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed steel/pvc conduit as required 2. supply & fixing of dp mcb 63 amp with metal box for input & output electricity supply of ups including connections etc. as required as per site requirement 3. wiring for circuit/ submain wiring along with earth wire with the 2 x 4 sq. mm + 1 x 2.5 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed steel/pvc conduit as required 4. wiring for circuit/ submain wiring along with earth wire with the 2 x 2.5 sq. mm + 1 x 1.5 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed steel/pvc conduit as required 5. supplying and fixing suitable size gi/pvc box with modular plate 6 module and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required....

Maharshi Dayanand University - Haryana

37470380 tender for electrical renovation of store room to be used as office in law department in mdu, rohtak copper wiring with modular switches in pvc conduit pvc conduit pipe only (surface or recessed) for electrical fitting and accessories supply and erection of double door sheet steel enclosure distribution boardsuitable for mcbs and elcbs etc wiring main and sub mains in two single core for phase and neutral wireand one single core for earth wire pvc insulated copper conductor cable1100 volts grade in existing ms/pvc conduit etc supply and fixing of 22 watt twintubelight with integral leddriver, available in single / double side connection options. make philps, havells, bajaj complete as per entire satisfaction of the engineer in charge. supply and fixing of 1 phase 4 module starter type modular switch for air conditioner with protection complete in all respect as per entire satisfaction of engineer work incharge. fixing of led tube light ...

Public Health Engineering Department - Haryana

37098710 tender for replacement of damaged ht ab cable 3 / 95 sqmm unwinding with ht xlpe 3 / c95mm2 on 11 kv line stp independent feeder fed from 66 kv s / station sohna under `op` sub division sohna, during the year 2021 22 1 m / s nut and bolts off size 2 ms angel 50x50x6 3 ms chanal 100x50x6 4 ms flate 50x6 5 steel fabrication 6 e / o ht xlpe cable 95m 7 erection of hdpe pipe dia 8 gi stay wire 7 / 8 swg 9 hdpe pipe 160mm dia 10 ht xlpe cable 3 / c 95mm2 11 erection of boring of earthing @ 31 per ft. ( 31x20=620 ) 12 11 kv pin insulatorwithg.i pin 13 d / o burrant ht ab cable 3c / 95 mm2 ( unwind ) for old ht / ab cable 95 sqmm 14 disc insulator for stay 15 e / o ht xlpe cable box 3c / 95m 16 earthing road 17 erection of 11kv 400amps g.o swith complete with handle pipe and suporting channel, as per nigams technical specification relevant iss and latest ammdments ( 9mtr. long ) 18 erection of earthing 19 erection of h pole complete with 2 stay 20 erection of single pole 11 mtr long 21 gi angle 50x50x6mm 2200mm 22 gi angle 50x50x6mm 2860mm 23 gi angle 50x50x6mm 2400mm ( for earth wire ) wt. 10.80 kg 24 gi channel 100 x 50 x 6mm 2200mm ( for h pole ) wt. 21.100kg 25 gi channel 75x40x6mm 2200mm wt. 15.30 kg 26 gi pipe 45mm dia 6mtr. long for earthing set b class 27 gi strips 25x60mm 9 mtr. long for earthing wt. 10.80 kg ( tata / sail make ) 28 loading transportation of t / f includng loading and undloading form store to site of work. ( 200 kva t / f ) 29 o / d ht xlpe cable box 95mm 30 stay set 8ft long complete with x plate 460mm of angle 65x65x6 elbow and rod wt. 13.80 kg 31 transportation of t / f includng loading and undloading form store to site of work. ( 200 kva t / f ) 32 wooden cleat...

Haryana Urban Development Authority - Haryana

36807399 providing electrification and street lighting in replanned hospital site in sector 13p ii, 15p, 16&17p ( phase ii ) , hisar ( including six years defect liability peirod for transformers and three years for mtc and defect liability period for other items 1 24.1earthing and lighting arrestor 1. earthing with gi earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. 2 24.1earthing and lighting arrestor 2. extra for using salt and charcoal / coke for pipe earth electrode as required. 3 24.1earthing and lighting arrestor 6. supply and laying of 25mm x3mm g.i. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required 4 24.2lta cable 1. supply and erection of lt phase separator on lt line complete in all respect up to entire satisfaction of the engineer in charge of the work. 5 24.3 ht cable 4.3.supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 11 kv grade as required:240 to 400 sqmm 6 23.22 mccb, distribution boards, mcbs rccbs change over etc. 1.3. supply and erection of modular case circuit breaker single pole/4 pole on existing wall/pedestal/ panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the engineer in charge of the work. triple pole mccb 16 to 100 amp 25 ka 7 23.22mccb, distribution boards, mcbs rccbs change over etc.5.1 supply and erection of miniature circuit breaker 240/415 v in the existing distribution board including making necessary connections: 6 amp to 32 amp single pole 8 23.27supply and erection of godrej almirah type m.s. pedestal made of 50mm x 50mm x 6mm angle iron frame made with 3.00mm thick m.s. sheet covering including shutters with suitable hinges and locking arrangement with godrej type handle including round bars. the top covering should have downward overhang of 75mm on all sides of pedestal, having two sets of water proof ventilation holes of suitable size on the sides, at top and bottom, each set containing four nos. holes to discharge the heat produced by the current. the shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof. the pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embedded upto the entire depth in 1:2:4 cement concrete block, projected 75mm all around the pedestal and 200mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the engineer in charge of the work: 3. m.s. pedestal of size 750mm wide, 1200mm high, 300mm deep and bottom totally open, duly embeded in cement concrete block of size 900mm x 450mm x 200mm above ground level, having a base of size 1050mm x600mm x 250mm below ground level. 9 job worksupply and erection of pvc insulated armoured underground cable in existing pipe / trench etc. of size 25 sqmm x 4 core for working voltage upto 1100 volts conforming to is:1554(part i) 1988/7098 (part i) with aluminium conductor isi marked complete in all respect as per standard specification upto the entire satisfaction of engineer in charge (make : grandlay, havell, polycab). 10 job worksupply, installation, testing, commissioning of 3 phase 11kv/0.433 kv 250v, 200 kva oil immersed, naturally cooled, aluminum wound outdoor type distribution transformers with csp (completely self protected) features with external microprocessor based four pole mccb 300amp. to 400amp., 50ka strictly conforming to nigam’s technical specification no. csc v/r i/dh/uh/p & d/2010 2011 read with amendment thereof and as per relevant iss as amended from time to time & losses conforming to 4 star rating of bee as per appd. make and specification of dhbvn/uhbvn including installation of transformer on existing platform upto the entire satisfaction of engineer in charge.valtage rated frequency permitted at 75ºci) maximum load looses at 50% load at 75ºc = 780 watt ii) maximum losses at 100% load at 75ºc = 2300 wattiii) warranty = 78/72 months shall be one time the above losses are maximum allowable & there would not be any positive tolerance. 11 job worksupply and erection of 11 kv g.o. switch with 9 nos. post insulator suitable heavy duty with suitable copper male and female contents for 11kv, g.i. pipe, nut and bolts complete as per iss: 1816/1972 and iss: 2544/1963 as per dhbvn specification with latest amendment thereof compete in all respect. 12 job worksupply and erection of 11kv lightning arrester as per approved makes and relevant is specifications of dhbvn. 13 job worksupply and erection of 11kv polymeric pin insulator 10 kn with gi pin of approved make / specification of dhbvn. 14 job worksupply and erection of acsr conductor of size 50mm2 conforming to is 398 (part ii) 1976/1996, is 4826 1976 is 1521 1972 and is 1778 1980 with latest amendments as per dhbvn specification including stringing & sagging jointing and binding with insulator at supports in all respect upto the entire satisfaction of engineer in charge. 15 job worksupply and erection of lt pvc unarmoured cable of size 300 sqmm single core with aluminium conductor 650/1100 v conforming to iss 1554 (part i) of 1988 is: 7098/part 1/ 1988 with latest amendments upto entire satisfaction of engineer in charge (make: grandlay, polycab, havells, cirtina) 16 job worksupply& erection of fuse unit of l.t. side suitable for 200 kva transformer as per dhbvn specification complete with wooden board, aluminium bus bar ms clamps and ms nut and bolts including all petty material required up to the entire satisfaction of engineer in charge 17 job worksupply & erection of l.t. aerial bunched cable of size 120 sqmm, 4 core + 95 sqmm messenger including making of necessary connection of make polycab, havell’s, grandlay complete in all respect upto the entire satisfaction of engineer in charge. 18 job worksupply and erection of wooden cleats of size 4” wide 1’ 6” long complete with 4 nos. holes suitable to pass through 300/400 sqmm single core cable complete in all respect upto the entire satisfaction of engineer in charge 19 job worksupply and erection of pcc pole as per is:1678 1960 specifications, 11mtr. long 140mm x 200mm at top and 140mm × 400mm at bottom with working load of 400 kg buried 2.20 m in ground as per dhbvnl specification. 20 job worksupply and erection of v shape cross arm suitable for 11 kv system made of out of 1650mm long ms channel of size 100x50x50x6mm as per design & drawing 2 nos. 18mm diaholes provided in the base for fixing of half clamp made of ms flat of size 50x6mm and 2 nos. holes 22mm dia for gi pin on the flange plate of ms flat of size 50x6mm shall be provided on the top and bottom flanges of both end of v shape x arm with 22mm hole in the plate complete in all respect including primer and aluminum paint. 21 job worksupply and erection of top hamper suitable for 11 mtr. long pcc pole and 11kv system made out of ms flat size 50×6mm (a shapes) having approx weight 2.5 kg as per approved design and drawing including primer and aluminium paint complete in all respect 22 job worksupply and erection of 11 kv polymeric disc insulator 45 kn for 11 kv over head lines with fittings, t&c and complete with galvanized strain clamps, bolts, nuts, washers etc. as required as per dhbvn specification. 23 job worksupply and erection of stay set for ht line complete with gss 7/8 swg, disc insulator, gi rod 20mm dia threaded up to 250mm length with nut (wt.6.224kg), cross plate 460 mm of channel 75 × 40 × 6mm (wt. 5.330 kg), (wt.5.330kg), elbow (wt.2.240kg), clamp with nut bolts etc as per dhbvn specification complete in all respect up to the entire satisfaction of engineer in charge. 24 job worksupply and erection of galvanized steel item (flat, angle, channel) including cutting bending to the required shape drilling hole carriage loading unloading complete in all respect upto the entire satisfaction of engineer in charge. 25 job worksupply and erection of galvanized nut and bolts of various sizes carriage loading unloading complete in all respect upto the entire satisfaction of engineer in charge. 26 job worksupply and erection of acsr conductor of size 100mm2 conforming to is 398 (part ii) 1976/1996, is 4826 1976 is 1521 1972 and is 1778 1980 with latest amendments as per dhbvn specification including stringing & sagging jointing and binding with insulator at supports in all respect upto the entire satisfaction of engineer in charge 27 job worksupply and erection of cradle guard made of gi wire of swg including fixing in 11kv line complete in all respect up to satisfaction of engineer in charge 28 job worksupply and erection of pcc pole as per is:1678 1960 specifications 9mtr. long 105mm x 115mm at top and 105mm × 315mm at bottom with working load of 200 kg. buried 1.80 m in ground or as dhbvnl specification. 29 job worksupply and erection of ms d strap iron clamps as per dhbvn design and specifications complete with bolts, nuts and washers, coach screws etc. as required. 30 job work supply and erection of shackle insulator as per dhbvn specification complete in all respect. 31 job worksupply and erection of stay set for lt line complete with gss 7/8 swg, egg, insulator gi rod 20mm dia threaded up to 250mm length with nut (wt.6.224kg), cross plate 460 mm of angle 65×65×6mm (wt.5.330kg), elbow (wt.2.240kg), clamp with nut bolts etc as per dhbvn specification complete in all respect up to the entire satisfaction of engineer in charge. 32 job worksupply and erection of acsr conductor of size 80mm2 conforming to is 398 (part ii) 1976/1996, is 4826 1976 is 1521 1972 and is 1778 1980 with latest amendments as per dhbvn specification including stringing & sagging jointing and binding with insulator at supports in all respect upto the entire satisfaction of engineer in charge. 33 job worksupply and erection of pvc insulated acsr conductor of size 30mm2 conforming to is 398 (part ii) 1976/1996, is 4826 1976 is 1521 1972 and is 1778 1980 with latest amendments as per dhbvn specification including stringing & sagging jointing and binding with insulator at supports in all respect upto the entire satisfaction of engineer in charge. 34 job worksupply, stringing and sagging 8 swg g.i. earth wire complete in all respect to the entire satisfaction of engineer in charge conforming to is 298/1978 and 7807/1973 and with latest amendment thereof 35 job worksupply and erection of 70 watt street light luminaire with multiple led with lighting efficient with power led light with lens pressure die cast aluminium housing, reflector and enclosed with toughened / polycarboniate glass, ip 66 level, having light efficiency of 120 lumens / watt upto the entire satisfaction of engineer in charge of the work make: bajaj / philips / lt (with 3 year free replacement warranty, mtc. including labour charges, free of cost). 36 job worksupply and erection of 40mm dia g.i. pipe (b class) bracket 1mtr. long for fixing of fitting on pcc pole including cost of nut and bolts with two nos. clamps made of 50x6mm m.s. flat clamp and other petty material required to complete the job including painting complete in all respect upto the entire satisfaction of the engineer in charge.. 37 job work supply and erection of of pvc flexible aluminium wire of size 2.50 sqmm single core complete in all respect as per standard specification upto the entire satisfaction of engineer in charge 38 job work supply and erection of cradle guard made of gi wire with guard reel including fixing in the lt line complete in all respect up to the satisfaction of engineer in charge 39 job worksupply, erection, testing & commissioning of elex tws 2ext / amson’s make automatic electric timer to switch on/off the street light / road light automatically. it should have lux level adjustable switch, with extensible mountable sensor.it will change on/off timing automatically as per lux level of season throughout the year as purchase in the timing of sun rising and sun setting suitable for street / road light.it will have three nos. l&t make, 3 pole power contactor model mnx 25 to control 25 amp. per phase with 220 volt coils. it will have auto/manual switching mode for repair of street light during day time and the whole unit fixed on bakelite sheet to assemble the components etc. with mcb 16 amp. capacity to save the time switch.the erection of the complete unit in the existing pedestal with complete wiring upto the satisfaction of the engineer in charge 40 job worksupply & erection of 11 kv (e) 300 sqmm x 3 core xlpe cable standard compact circular alum. conductor screened, xlpe insulated screened with extruded semi conducting compound in combination with copper tape (3.0) la for one second alum. round/ strip armoured and overall pvc sheathed cable as per is 1554 i/1988 complete in all respect upto entire satisfaction of engineer in charge of work ...

Haryana Urban Development Authority - Haryana

36807394 providing electrification and street light in sector 1p ii at hisar ( including six years defect liability peirod for transformers and three years for mtc and defect liability period for other items, free of cost ) 1 24.1earthing and lighting arrestor 1. earthing with gi earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. ( but without charcoal or coke and salt ) as required. 2 24.1earthing and lighting arrestor 2. extra for using salt and charcoal / coke for pipe earth electrode as required. 3 24.1earthing and lighting arrestor 6. supply and laying of 25mm x3mm g.i. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required 4 24.2lta cable 1. supply and erection of lt phase separator on lt line complete in all respect up to entire satisfaction of the engineer in charge of the work. 5 23.22 mccb, distribution boards, mcbs rccbs change over etc. 1.3. supply and erection of modular case circuit breaker single pole / 4 pole on existing wall / pedestal / panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the engineer in charge of the work. triple pole mccb 16 to 100 amp 25 ka 6 23.22mccb, distribution boards, mcbs rccbs change over etc.5.1 supply and erection of miniature circuit breaker 240 / 415 v in the existing distribution board including making necessary connections: 6 amp to 32 amp single pole 7 23.27supply and erection of godrej almirah type m.s. pedestal made of 50mm x 50mm x 6mm angle iron frame made with 3.00mm thick m.s. sheet covering including shutters with suitable hinges and locking arrangement with godrej type handle including round bars. the top covering should have downward overhang of 75mm on all sides of pedestal, having two sets of water proof ventilation holes of suitable size on the sides, at top and bottom, each set containing four nos. holes to discharge the heat produced by the current. the shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof. the pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embedded upto the entire depth in 1:2:4 cement concrete block, projected 75mm all around the pedestal and 200mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the engineer in charge of the work: 3. m.s. pedestal of size 750mm wide, 1200mm high, 300mm deep and bottom totally open, duly embeded in cement concrete block of size 900mm x 450mm x 200mm above ground level, having a base of size 1050mm x600mm x 250mm below ground level. 8 job worksupply and erection of pvc insulated armoured underground cable in existing pipe / trench etc. of size 25 sqmm x 4 core for working voltage upto 1100 volts conforming to is:1554 ( part i ) 1988 / 7098 ( part i ) with aluminium conductor isi marked complete in all respect as per standard specification upto the entire satisfaction of engineer in charge ( make : grandlay, havell, polycab ) . 9 job worksupply, installation, testing, commissioning of 3 phase 11kv / 0.433 kv 250v, 200 kva oil immersed, naturally cooled, aluminum wound outdoor type distribution transformers with csp ( completely self protected ) features with external microprocessor based four pole mccb 300amp. to 400amp., 50ka strictly conforming to nigam’s technical specification no. csc v / r i / dh / uh / p & d / 2010 2011 read with amendment thereof and as per relevant iss as amended from time to time & losses conforming to 4 star rating of bee as per appd. make and specification of dhbvn / uhbvn including installation of transformer on existing platform upto the entire satisfaction of engineer in charge.valtage rated frequency permitted at 75ºci ) maximum load looses at 50% load at 75ºc = 780 watt ii ) maximum losses at 100% load at 75ºc = 2300 wattiii ) warranty = 78 / 72 months shall be one time the above losses are maximum allowable & there would not be any positive tolerance. 10 job worksupply and erection of 11 kv g.o. switch with 9 nos. post insulator suitable heavy duty with suitable copper male and female contents for 11kv, g.i. pipe, nut and bolts complete as per iss: 1816 / 1972 and iss: 2544 / 1963 as per dhbvn specification with latest amendment thereof compete in all respect. 11 job worksupply and erection of 11kv lightning arrester as per approved makes and relevant is specifications of dhbvn. 12 job worksupply and erection of 11kv polymeric pin insulator 10 kn with gi pin of approved make / specification of dhbvn. 13 job worksupply and erection of acsr conductor of size 50mm2 conforming to is 398 ( part ii ) 1976 / 1996, is 4826 1976 is 1521 1972 and is 1778 1980 with latest amendments as per dhbvn specification including stringing & sagging jointing and binding with insulator at supports in all respect upto the entire satisfaction of engineer in charge. 14 job worksupply and erection of lt pvc unarmoured cable of size 300 sqmm single core with aluminium conductor 650 / 1100 v conforming to iss 1554 ( part i ) of 1988 is: 7098 / part 1 / 1988 with latest amendments upto entire satisfaction of engineer in charge ( make: grandlay, polycab, havells, cirtina ) 15 job worksupply& erection of fuse unit of l.t. side suitable for 200 kva transformer as per dhbvn specification complete with wooden board, aluminium bus bar ms clamps and ms nut and bolts including all petty material required up to the entire satisfaction of engineer in charge 16 job worksupply & erection of l.t. aerial bunched cable of size 120 sqmm, 4 core + 95 sqmm messenger including making of necessary connection of make polycab, havell’s, grandlay complete in all respect upto the entire satisfaction of engineer in charge. 17 job worksupply and erection of wooden cleats of size 4” wide 1’ 6” long complete with 4 nos. holes suitable to pass through 300 / 400 sqmm single core cable complete in all respect upto the entire satisfaction of engineer in charge 18 job worksupply and erection of pcc pole as per is:1678 1960 specifications, 11mtr. long 140mm x 200mm at top and 140mm × 400mm at bottom with working load of 400 kg buried 2.20 m in ground as per dhbvnl specification. 19 job worksupply and erection of v shape cross arm suitable for 11 kv system made of out of 1650mm long ms channel of size 100x50x50x6mm as per design & drawing 2 nos. 18mm diaholes provided in the base for fixing of half clamp made of ms flat of size 50x6mm and 2 nos. holes 22mm dia for gi pin on the flange plate of ms flat of size 50x6mm shall be provided on the top and bottom flanges of both end of v shape x arm with 22mm hole in the plate complete in all respect including primer and aluminum paint. 20 job worksupply and erection of top hamper suitable for 11 mtr. long pcc pole and 11kv system made out of ms flat size 50×6mm ( a shapes ) having approx weight 2.5 kg as per approved design and drawing including primer and aluminium paint complete in all respect 21 job worksupply and erection of 11 kv polymeric disc insulator 45 kn for 11 kv over head lines with fittings, t&c and complete with galvanized strain clamps, bolts, nuts, washers etc. as required as per dhbvn specification. 22 job worksupply and erection of stay set for ht line complete with gss 7 / 8 swg, disc insulator, gi rod 20mm dia threaded up to 250mm length with nut ( wt.6.224kg ) , cross plate 460 mm of channel 75 × 40 × 6mm ( wt. 5.330 kg ) , ( wt.5.330kg ) , elbow ( wt.2.240kg ) , clamp with nut bolts etc as per dhbvn specification complete in all respect up to the entire satisfaction of engineer in charge. 23 job worksupply and erection of galvanized steel item ( flat, angle, channel ) including cutting bending to the required shape drilling hole carriage loading unloading complete in all respect upto the entire satisfaction of engineer in charge. 24 job worksupply and erection of galvanized nut and bolts of various sizes carriage loading unloading complete in all respect upto the entire satisfaction of engineer in charge. 25 job worksupply and erection of acsr conductor of size 100mm2 conforming to is 398 ( part ii ) 1976 / 1996, is 4826 1976 is 1521 1972 and is 1778 1980 with latest amendments as per dhbvn specification including stringing & sagging jointing and binding with insulator at supports in all respect upto the entire satisfaction of engineer in charge 26 job worksupply and erection of cradle guard made of gi wire of swg including fixing in 11kv line complete in all respect up to satisfaction of engineer in charge 27 job worksupply and erection of pcc pole as per is:1678 1960 specifications 9mtr. long 105mm x 115mm at top and 105mm × 315mm at bottom with working load of 200 kg. buried 1.80 m in ground or as dhbvnl specification. 28 job worksupply and erection of ms d strap iron clamps as per dhbvn design and specifications complete with bolts, nuts and washers, coach screws etc. as required. 29 job work supply and erection of shackle insulator as per dhbvn specification complete in all respect. 30 job worksupply and erection of stay set for lt line complete with gss 7 / 8 swg, egg, insulator gi rod 20mm dia threaded up to 250mm length with nut ( wt.6.224kg ) , cross plate 460 mm of angle 65×65×6mm ( wt.5.330kg ) , elbow ( wt.2.240kg ) , clamp with nut bolts etc as per dhbvn specification complete in all respect up to the entire satisfaction of engineer in charge. 31 job worksupply and erection of acsr conductor of size 80mm2 conforming to is 398 ( part ii ) 1976 / 1996, is 4826 1976 is 1521 1972 and is 1778 1980 with latest amendments as per dhbvn specification including stringing & sagging jointing and binding with insulator at supports in all respect upto the entire satisfaction of engineer in charge. 32 job worksupply and erection of pvc insulated acsr conductor of size 30mm2 conforming to is 398 ( part ii ) 1976 / 1996, is 4826 1976 is 1521 1972 and is 1778 1980 with latest amendments as per dhbvn specification including stringing & sagging jointing and binding with insulator at supports in all respect upto the entire satisfaction of engineer in charge. 33 job worksupply, stringing and sagging 8 swg g.i. earth wire complete in all respect to the entire satisfaction of engineer in charge conforming to is 298 / 1978 and 7807 / 1973 and with latest amendment thereof 34 job worksupply and erection of 70 watt street light luminaire with multiple led with lighting efficient with power led light with lens pressure die cast aluminium housing, reflector and enclosed with toughened / polycarboniate glass, ip 66 level, having light efficiency of 120 lumens / watt upto the entire satisfaction of engineer in charge of the work make: bajaj / philips / lt ( with 3 year free replacement warranty, mtc. including labour charges, free of cost ) . 35 job worksupply and erection of 40mm dia g.i. pipe ( b class ) bracket 1mtr. long for fixing of fitting on pcc pole including cost of nut and bolts with two nos. clamps made of 50x6mm m.s. flat clamp and other petty material required to complete the job including painting complete in all respect upto the entire satisfaction of the engineer in charge.. 36 job worksupply and erection of 25 watt pressure die cast aluminium housing led street light fitting luminaire with multiple led lenses and leat resislant polycarboniate. cover glass ip65 of complete in all respect as per specifications having light efficiency of 120 lumens / watt upto the entire satisfaction of engineer in charge of the work make: bajaj / philips / lt ( with 3 year free replacement warranty, mtc. including labour charges, free of cost ) . 37 job worksupply and erection of 32mm dia g.i. pipe ( b class ) bracket 1mtr. long for fixing of fitting on pcc pole including cost of nut and bolts with two nos. clamps made of 50x6mm m.s. flat clamp and other petty material required to complete the job including painting complete in all respect upto the entire satisfaction of the engineer in charge 38 job work supply and erection of of pvc flexible aluminium wire of size 2.50 sqmm single core complete in all respect as per standard specification upto the entire satisfaction of engineer in charge 39 job work supply and erection of cradle guard made of gi wire with guard reel including fixing in the lt line complete in all respect up to the satisfaction of engineer in charge 40 job worksupply, erection, testing & commissioning of elex tws 2ext / amson’s make automatic electric timer to switch on / off the street light / road light automatically. it should have lux level adjustable switch, with extensible mountable sensor.it will change on / off timing automatically as per lux level of season throughout the year as purchase in the timing of sun rising and sun setting suitable for street / road light.it will have three nos. l&t make, 3 pole power contactor model mnx 25 to control 25 amp. per phase with 220 volt coils. it will have auto / manual switching mode for repair of street light during day time and the whole unit fixed on bakelite sheet to assemble the components etc. with mcb 16 amp. capacity to save the time switch.the erection of the complete unit in the existing pedestal with complete wiring upto the satisfaction of the engineer in charge...

Central Organisation Railway Electrification - Haryana

36714359 supply of come along clamp for catenary suitable for 65 sq mm [ 19 / 2.108 mm [ conductor 03 ton with load test certificate from govt approved lab . make modern engg, international motor, power equipment their own make and similar. [ warranty period: 30 months after the date of delivery ] , come along clam for earth wire anti creep wire suitable for 19 / 2.5 mm galvanized steel conductor overall dia 12.5 mm capacity 04 tones with load test certificate from government approved lab. make hitronics, power equipments, im their own make. and similar. [ warranty period: 30 months after the date of delivery ] , ccome along clamp suitable for 107 sqmm contact wire conductor capacity 3.5 ton with load test certificate from govt approved lab. make im, pec, sdu sst, hitronics, im their own make and similar [ warranty period: 30 months after the date of delivery ] => limited...

Indian Army - Haryana

36279371 bids are invited for spares of skid steer loader mse earth wire , lead heater , temp sensor , socket snow blower , tee union , hand pump seal kit , cabin lifting pump , dual indicator hyd clog , fan switch , water temp gauge , working light switch , becon light switch , parking brake switch , dual indicator bty water temp oil pressure , dual indicator bty heater glow , left right indicator switch , bty clamping bracket , rotating cyl seal kit , seal kit , lock washer , hyd motor gear , diesel cap , hose assy , control valve hose , flexible hose assy , clevis , brake valve hose total quantity : 40...

Indian Army - Haryana

35786830 bids are invited for spares of skid steer loader mse horn 12v , fan 12v , knob lvever with switch , head light , direction indicator light , way ignition switch , battery cut off switch , battery cable positive , battery cable negative , earth wire , bulb 12v , hour meter , hyd oil temp gauge , cabin light , all type switches , indicator shield , fan , bowex coupling , hose assy , air cleaner clamp total quantity : 94...

Military Engineer Services - Haryana

35258374 tender for repair / maintenance to certain lt equipment alongwith electrical fittings and repair to certain b / r works at af station naraina and afnd in aor of ge ( af ) faridabad taking down carefully copper / aluminium point wiring ( light, fan, socket, bell or power ) completeincluding all electrical fittings & fixtures ( dbs, submain, cables etc ) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified and directed by engineer in charge. 2 m&l for point wiring light point / bell point with single core pvc insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 sq mm ( nominal area ) drawn through in existing concealed conduit, fixed on wall, ceiling with gi saddles gi screws, rawal plugs ( concealed conduit wiring ) with all fittings including tee, junction boxes and provision of modular metal flush boxof suitable sizemodular white cover plate with frame for mounting switch sockets and regulators and drawing continuous earth wire with and including pvc insulated unsheathed 1100 volts grade cable with stranded coper conductor of size 1.5 sq mm ( nominal area ) complete all as specified and directed by engineer in charge for following : .note: after rewiring cutting chasing portion should be matched with existing finishes of walls. 3 all as per item no 2 above but 5 amp socket outlet, independent complete all as specified and directed by engineer in charge. 4 all as per item no 2 above but on the same board complete all as specified and directed by engineer in charge. 5 all as per item no 2 above but 2.5 sq mm wire for one 15 amps socket outlet independent with continuous pvc insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly complete all as specified and directed by engineer in charge. 6 m&l switch flush type bell push 1 module modular typebutton 6 amp after dismantling old one complete all as specified and directed by engineer in charge. 7 m&l for socket outlet 6a 2 / 3 pin combined 2 module modular type complete all as specified and directed by engineer in charge. 8 m&l for socket outlet 6a / 16a 2 / 3 pin combined 2 module modular type complete all as specified and directed by engineer in charge. 9 m&l for switch 6 amps modular type one one way complete all as specified and directed by engineer in charge. 10 m&l for switch 16 amps modular type one one way complete all as specified and directed by engineer in charge. 11 m&l for modular type fan regulator ( step type ) , 120 w 1 module complete all as specified and directed by engineer in charge. 12 m&l metal flush box 3 module complete all as specified and directed by engineer in charge. 13 m&l metal flush box 6 module complete all as specified and directed by engineer in charge. 14 m&l metal flush box 12 module complete all as specified and directed by engineer in charge. 15 m&l for white cover plate with frame, 12 module complete all as specified and directed by engineer in charge. 16 m&l for white cover plate with frame, 6 module complete all as specified and directed by engineer in charge. 17 m&l for white cover plate with frame, 3 module complete all as specified and directed by engineer in charge. 18 s&f bell ding dong ac 230volts single pole complete all as specified and directed by engineer in charge. 19 s &f in replacement switch socket combination 16a, 6pin, 3module 220 / 230 volts complete all as specified and directed by engineer in charge. 20 s&f in replacement switch piano type 5 amp sp one way isi marked complete all as specified and directed by engineer in charge. 21 s&fin replacement switch 15 amps sp one way isi marked complete all as specified and directed by engineer in charge. 22 s&f in replacement socket outlet 3 pin 5 amps flush type complete all as specified and directed by engineer in charge. 23 s&f in replacement socket outlet 2 in 1, 3 pin 5 amp and 15 amps complete all as specified and directed by engineer in charge. 24 m&l for bell push flush type 5 / 6 amps one way complete all as specified and directed by engineer in charge. 25 s&f in replacement of wall mounting slim 18 / 20 watt 4 feet led batten luminaire , white with engineering plastic batten with white acrylic cover sleek design & high efficiency for wall and surface mounted applicationsall as specified and directed by engineer in charge. 26 s&f in replacement of wall mountingled slim 9 / 10 watt 2 feet, white with high efficient leds & glare free opal diffuser complete all as specified and directed by engineer in charge. 27 s & f in replacement enviroment friendly recess / surface mounting led flat panel 2x2, cool white with high efficient leds & glare free opal diffuser ( 36 w ) pf>0.95 driver life >25000 hours, operating range 140v to 280 v includingall accessaries complete all as specified and directed by engineer in charge. 28 s& f led fitting bulkhead 10 watt single phase 50 hz ip 66 outdoor type complete all as specified and directed by engineer in charge. 29 s&f in replacement of recesses mountingled slim round downlighter 12 watt warmwhite with high efficient leds & glare free opal diffuser complete all as specified and directed by engineer in charge. 30 s&f in replacement of recesses mountingled slim square downlighter 12 watt warmwhite with high efficient leds & glare free opal diffuser complete all as specified and directed by engineer in charge. 31 s&f in replacement mcb sp 5 to 32 amps, 240 volts curve c, breaking capacity 10kacomplete all as specified and directed by engineer in charge. 32 s&f in replacement mcb spn32 to 63 amps, 240 volts, curve c, breaking capacity 10 ka, complete all as specified and directed by engineer in charge. 33 s&f in replacement mcb tp 40 to 63 amps, 415 volts curve c, breaking capacity 10kacomplete all as specified and directed by engineer in charge. 34 s&f in replacement mcb tpn 40 amps, 415 volts curve c, breaking capacity 10ka, complete all as specified and directed by engineer in charge. 35 s&f in replacement mcb tpn 63 amps, 415 volts curve c, breaking capacity 10ka, complete all as specified and directed by engineer in charge. 36 s&f in replacement mcb 4 pole 100 amps, 415 volts curve c, breaking capacity 10ka, complete all as specified and directed by engineer in charge. 37 s&f in replacement mccb, four pole, 415 volts, 125 amps , curve c, breaking capacity 10 ka, complete all as specified and directed by engineer in charge. 38 s&f sheet metal enclosuresdbdouble door verticle distribution type, 04 way, tpn db , ip43, 415v & suitable for mccb tp as incomming including shruded neutral bar & pan assy with earthing terminal as provided by manufacturercomplete all as specified and directed by engineer in charge. 39 s&f sheet metal enclosuresdbdouble doordistribution type, 04 way, tpn db , ip43, 415v & suitable for mcb tp as incomming including shruded neutral bar & pan assy with earthing terminal as provided by manufacturer complete all as specified and directed by engineer in charge. 40 s&f sheet metal enclosuresdbdouble doordistribution type, 06 way, tpn db , ip43, 415v & suitable for mcb tp as incomming including shruded neutral bar & pan assy with earthing terminal as provided by manufacturer complete all as specified and directed by engineer in charge. 41 s&f in replacement sheet metal enclosuresdbdouble door type 8 way spn 240 voltincluding 200 amps rated bus bar with neutral link complete all as specified and directed by engineer in charge. 42 s&f in replacement sheet metal enclosuresdbdouble door type 4 way spn 240 voltincluding 200 amps rated bus bar with neutral link complete all as specified and directed by engineer in charge. 43 s&f for ceiling rose surface bakelite 65x50mm two to three terminals complete all as specified and as directed by engr in charge. 44 s& f in repair casing capping of size 15 mmto cover the copper conductor in wall complete all as specified and directed by engineer in charge. 45 s&f in replacement of led electronic driver suitable for 20 watt led batten fitting complete all as specified and directed by engineer in charge. 46 s&f in replacement of led electronic driver suitable for 36 watt led ( 2x2 ) recesses mountedfitting complete all as specified and directed by engineer in charge. 47 supply and fix external wall mounted switch board 15 amps consisting of one number 15 amps switch and socket including frame and sheet complete with screws al as specified and as directed by engineer in charge. 48 supply and fix external wall mounted switch board 5 amps consisting of one number 5 amps switch and socket including frame and sheet complete with screws al as specified and as directed by engineer in charge. 49 taking down pressure pump motor of capacity upto 1 hp, single phase , 230 volt all as per specified and as directed by engineer in charge. 50 m&l for rewinding of presume pump motor of capacity upto 1 hp single phase , 230 volt all as per specified and as directed by engineer in charge. 51 m&l for refixing presume pump motor of capacity upto 1 hp single phase , 230 volt all as per specified and as directed by engineer in charge. 52 m&l earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand includinggalvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means ofnuts and bolts, check nuts and washers of gi and connected to earhing test point and earth dollyall as shown in electrical plate no 3 of mes ssr part i and testing on completion includingnecessary excavation and earth work in any type of soil, pcc ( 1:3:6 ) type c1 chamber, pre cast rcc slab 50mm thic in cement concrete ( 1:2:4 ) , type b1, reinforced with welded steel wire fabric or xpm, ( weight not less than 4 kg per sqm ) with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, gi protection pipe, 15mm dia, light grade, 7.5 mtr long for protection of earth lead upto test point etc complete all as specified and directed by engineer in charge. 53 s&f isi marked self adhesive pvc electrical insulation tape roll of 25 mm wide, 0.125 mm thick and 25 rm lengthcomplete all as specified and directed by engineer in charge. 54 taking down carefully water heater storage type 25 ltrs / 50 ltrs capacity for repair and over hauling and opening to geysers and comprising of heating element thermo stat switch, electric connection cleaning and descaling with descaling solution the geysers tank and checking of leakage on pressure at 150 psi and testing for smooth functioning complete all as specified and directed by engineer in charge. 55 s&f in replacement of heating element 2.00 kw capacity 230 volt suitable for geysers any type as per site requirement isi mark complete all as specified and directed by engineer in charge: 56 all as per item no 55above but 1.5 kw capacity 230 volt complete all as specified and directed by engineer in charge. 57 s&f in replacement thermostat switch connection any type suitable for geyser of any size / model complete all as specified and directed by engineer in charge. 58 s&f in replacement of geyser assembly any make any type for 25 ltrs / 50 ltrs capacity water heater including replacement of rubber seal complete all as specified and directed by engineer in charge. 59 supply and fixing in replacement of indicator lamp ( pilot type ) for 25 ltrs water heater complete all as specified and directed by engineer in charge. 60 supply and fixing in replacement of pvc insulated copper conductor cable 4 sqmm size 3 core grade ( for geyser ) complete all as specified and directed by engineer in charge. 61 s&f in replacement of water storage tank of suitable for 25ltrs capacity incl glass wool complete all as specified and directed by engineer in charge. 62 s&f in replacement of water storage tank of suitable for 50ltrs capacity incl glass wool complete all as specified and directed by engineer in charge. 63 supply & fixing in replacement ofbottom cover suitable cylindrical type geyser for 25 ltrs / 50 ltrscapacity geyser all as specified and directed by engineer in charge 64 all as per item no 63 above but of capacity 50 ltrscomplete all as specified and directed by engineer in charge. 65 m&l for preparation of external surface of geyser body 25 / 50 ltrs rubbing the rusted surface and painting with two coats of spray paint with synthetic enamel paint over a coat of metal primer matching with existing colour complete all as specified and directed by engineer in charge. 66 s& f heavy duty pvc pipe suitable for hot water flow for geysers of capcity 25 to 50 ltrs all as specified and as directed by engineer in charge 67 s& f plug top 3 pin , 15 amps rating all as specified and as directed by engineer in charge 68 s& f plug top 3 pin , 5 amps rating all as specified and as directed by engineer in charge 69 s&f in replacement ac box with plug and socket complete with 16 to 32 amp sp mcb c curve 10 ka complete all as specified and directed by engineer in charge. 70 s& f water heater body metallic type suitable for 25 ltr capacity including glass wool for insulation top and bottom plates complete all as specified and directed by engineer in charge. 71 s&f heating element 2 3 kw thread type / cone type compatible with 10 to 300 ltr solar water heater tank complete all as specified and directed by engineer in charge. 72 supply and in install heating element 2 3 kw thread type / cone type compatible with instant water heater complete all as specified and directed by engineer in charge. 73 s&f in repair wall mounted tpn busbar chamber factory made with busbar of current rating 400 amp, 415 volts complete all as specified and directed by engineer in charge. 74 supply and fixing in replacement of capacitor of following sizes complete all as specified and directed by engineer in charge. ( a ) .2.5 mfd. 75 all as per item no 74 above but 3.15 mfd complete all as specified and directed by engineer in charge. 76 m&l for rewinding of burnt fan1200 mm / 1400 mm sweepwith super enameled copper wire winding, rubber real, u’ clamps, nuts, bolts, washers and split pins of suitable size as per details of any make / model complete all as specified and directed by engineer in charge. 77 taking down ceiling fan 1200 mm / 1400 mm sweep removing cleaning of dust, properly cleaning and greasing of bearing and connecting up complete all as specified and directed by engineer in charge. 78 supply in replacement for rewinding of exhaust fan as per details given below with supper enameled copper wireof suitable size of any make / type / model including transportation complete all as specified and directed by engineer in charge : ( a ) exhaust fan 300mm ( 12’size ) 79 all as per item no 78 abive butexhaust fan 380mm ( 15” size ) complete all as specified and directed by engineer in charge. 80 supply in replacementfor exhaust fan louver of following size complete all as specified and directed by engineer in charge. ( a ) 380 mm 81 all as per item no 80 above but 300 mm complete all as specified and directed by engineer in charge. 82 taking down carefully defective wall mounted fan of any size and make and oiling greasing after opening and refixing the fan to its position after repair and testing complete all as specified and directed by engineer in charge. ( a ) wall fan of size 400mm 83 all as per item no 82 above but wall fan of size 300mm complete all as specified and directed by engineer in charge. 84 m&l for rewinding of wall mounted fan given below with super enameled copper wire including of suitable of size of any make / type model complete all as specified and directed by engineer –in charge : ( a ) wall fan of size 400mm 85 all as per item no 84 above but wall fan of size 300mm complete all as specified and directed by engineer in charge. 86 supply and fixing in replacementventilation fan plastic 250 mm sweepbody 240 v 50 hz single phase all as specified and directed by engineer in charge. 87 supply and fixing in replacementventilation fan plastic 300 mm sweepbody 240 v 50 hz single phase all as specified and directed by engineer in charge. 88 supply and fixing in replacement 450mm sweep wall mounted fan plastic body 240 v single phase 50 hz all as specified and directed by engineer in charge. 89 s&f in replacement for wall mounted fan bushes , shaft and suitable body cover , moving partcomplete all as specified and directed by engineer in charge. 90 supply only isi marked self adhesive pvc electrical insulation tape roll of 25 mm wide, 0.125 mm thick and 25 rm lengthcomplete all as specified and directed by engineer in charge. 91 s&f decorative 45 w led strip light including drivers and necessary connections non integral flexible type with high brihtness for indoor and outdoor applications. strip can be cut at marked interval to suit desired length.all as specified and as directed by engineer in charge 92 m&l submain wiring with 2 runs of copper conductor frls pvc insulated unsheathed cable 1100 volt grade 4 sqmm drawn through pvc conduit medium grade isi marked25mm dia as per is specification fixed concealedin wall / ceiling including conduit and conduit accessories and incl provn of pvc insulated 2.5 sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by engineer in charge. note : two runs of 4 sqmm cable alongwith one run of 2.5 sqmm pvc insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length ) 93 m&l submain wiring with 2 runs of copper conductor frls pvc insulated unsheathed cable 1100 volt grade 6 sqmm drawn through pvc conduit medium grade isi marked25mm dia as per is specification fixed concealedin wall / ceiling including conduit and conduit accessories and incl provn of pvc insulated 4 sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by engineer in charge.note : two runs of 6 sqmm cable alongwith one run of 4 sqmm pvc insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length ) . 94 s&f in repair led 40 wattpost top lantern with die cast aluminum spigot , spun aluminium caoted top cover heat sink , opal diffuser and clear acrylic ip65 complete all as specified and directed by engineer in charge. 95 s&f in repair led 60 wattpost top lantern with die cast aluminum spigot , spun aluminium caoted top cover heat sink , opal diffuser and clear acrylic ip65 complete all as specified and directed by engineer in charge. 96 s&f in replacement ofsingle core frls cable pvcunsheathed with copper conductor of size 1.5 sqmmand drawing into existing conduit complete all as specified and directed by engineer in charge. 97 s&f in replacement ofsingle core frls cable pvcunsheathed with copper conductor of size 2.5 sqmmand drawing into existing conduit complete all as specified and directed by engineer in charge. 98 excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in loose / soft soil and getting out complete all as specified and directed by engineer in charge. 99 returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by engineer in charge. 100 removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by engineer in charge. 101 m & lfor brick protection with sub class b brickslaid dry flat over electric cable in trenches complete all as specified and directed by engineer in charge. 102 m & labour for sand cushioning with a layer of sand 80mm thickconsolidated before laying of cable and 150mm thickconsolidated after laying of cable in trenches ducts for electric cable protection including consolidation complete all as specified and directed by engineer in charge. 103 supply, laying and testing cable xlpe insulated , screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 400 sq mm 3.5 core complete all as specified and directed by engineer in charge. 104 supply, laying and testing cable xlpe insulated , screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 630 sq mm x 3.5 core complete all as specified and directed by engineer in charge. 105 supply, laying and testing cable xlpe insulated , screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed by engineer in charge. 106 supply, laying and testing cable xlpe insulated , screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed by engineer in charge. 107 supply, laying and testing cable xlpe insulated , screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed by engineer in charge. 108 supply and fix in replacement mccb 630 amps , 4 pole , 50 ka , 50 hz , 415 voltincluding under voltage / over voltage relay, adjustable overload setting and short circuit setting complete all as specified and directed by engineer in charge. 109 supply and fix in replacementmccb 400 amps , 4 pole , 36 ka , 50 hz , 415 voltincluding under voltage / over voltage relay, adjustable overload setting and short circuit setting complete all as specified and directed by engineer in charge. 110 supply and fix in replacementmccb 250 amps , 4 pole , 25 ka , 50 hz , 415 voltincluding under voltage / over voltage relay, adjustable overload setting and short circuit setting complete all as specified and directed by engineer in charge. 111 supply and fixing in repair / replacement of solar street light fittings with integrated 12 watt led street light system with solar pv panel 100 wp, integrated led fitting with li ion battery 11.1 v 17 ah , mppt based solar charge controller, motion sensor and tubular pole of height 5 mtrs complete all as specified and directed by engineer in charge. 112 supply and fix in repair on load changeover switch 63 amp 4 pole, 415 v, 50 hz in sheet steel enclosure forsurface mounting with padlocking facilitywith the connecting accessories complete all as specified and directed by engineer in charge. 113 supply and fix in repair air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed by engineer in charge. 114 supply and fix in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by engineer in charge. 115 supply and fix in repair copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by engineer in charge. 116 supply and fix in replacement of starter panel for 7.5 hp motor , 3 phase , 415 v in sheet enclosure including phase corretor complete all as specified and directed by engineer in charge. 117 supply and fix cable jointing kit for 1.1 kv grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3 ½xlpe, armoured, al conductor cable of size 70 to 95 sqmm, outdoor type complete all as specified and directed by engineer in charge. 118 supply and fix cable jointing kit for 1.1 kv grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3 ½xlpe, armoured, al conductor cable of size 16 to 35 sqmm, outdoor type complete all as specified and directed by engineer in charge. 119 supply and fix cable jointing kit for 1.1 kv grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3 ½xlpe, armoured, al conductor cable of size 300 to 400 sqmm, outdoor type complete all as specified and directed by engineer in charge. 120 supply and fix cable jointing kit for 1.1 kv grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3 ½xlpe, armoured, al conductor cable of size 630 sqmm, outdoor type complete all as specified and directed by engineer in charge. 121 supply and fix in repair on load changeover switch 400 amp 4 pole , 415 v, 50 hz in sheet steel enclosure for surface mounting with padlocking facilitywith the connecting accessories complete all as specified and directed by engineer in charge. 122 supply and fix in repair on load changeover switch 630 amp 4 pole , 415 v, 50 hz in sheet steel enclosure for surface mounting with padlocking facilitywith the connecting accessories complete all as specified and directed by engineer in charge. 123 s&f in repair led flood light 120 wattisi marked, enviromental friendly high efficient, pressure die castwith aluminium extruded heat sink ip66 toughened glasscomplete all as specified and directed by engineer in charge. 124 s&f in repair led post top lantern 70 watt with die castaluminum pipe spigot , aluminium pdc heat sink , opal diffuser ip65complete all as specified and directed by engineer in charge. 125 m&l for repair of submersiblepump of capacity 10 hp , 3 phase shifting to workshopcomplete opening for rewinding with super enamled copper wire of existing size & repair / replacement of worn out parts such as shaft, ball bearing, bush, impellers, coupling , mechanical seal, jet assembly etc including re assembling and refixing in position complete all as specified and directed by engineer in charge. 126 m&l for repair of centrifugal pump of capacity 5 hp to 7.5 hp , 3 phase shifting to workshopcomplete opening for rewinding with super enamled copper wire of existing size & repair / replacement of worn out parts such as shaft, ball bearing, bush, impellers, coupling , mechanical seal, jet assembly etc including re assembling and refixing in position complete all as specified and directed by engineer in charge. 127 taking up or down following sizes steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by engineer in charge.25 mm bore 128 all as per item no 127 above but 20 mm bore complete all as specified and directed by engineer in charge. 129 all as per item no 127 above but 15mm bore complete all as specified and directed by engineer in charge. 130 supply, laying and fixing gi water tubing medium grade with all fittings and fixed complete to all walls, ceiling, laid in floors, roof etc withfollowing sizes complete all as specified and directed by engineer in charge. 25 mm bore 131 all as per item no 130 above but 20 mm bore complete all as specified and directed by engineer in charge. 132 all as per item no 130 above but15 mm bore complete all as specified and directed by engineer in charge. 133 supply, installing testing and commissioning in replacement of factory made and tested ( including cpri test cetified ) indoortype floor mountedltpanel board, cubical type suitable for 415 volts 3 phase, 4 wire 50hz, ac supply system having busbar chember with insulated al busbar of rating min. 1.5 times the rated capacity of incomer mccb for phaseinstalled on porcelin / smc insulators. the panel shall be dust and vermin proof ip 54 class protection and made out of 2.00 mm thickcrca ms sheetpowder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with aproaches for cable entry with double door shutter and locking arrangementsincluding internal wiring with pvc insulated stranded copper conductor cable frls is 694 sheathed 1100v grade of appropriate size complete all as specified and directed by engineer in charge..the panel shall be comprising of following: incoming ( i ) mains mccb 4 pole 400 amps with adjustable setting, 415 volts with breaking capacity 36 ka. 01 no. ( ii ) digital type voltmeter 0 500 volts and with selector switch 01 no. ( iii ) digital amp meterwith cts & built in selector switch 01 no. ( iv ) indication lamp ryb 01 set.outgoing ( i ) mccb 4 pole 100 amps, , 415 volts with breaking capacity 16 ka. 05no. ( ii ) mccb 4 pole 63 amps, 415 volts with breaking capacity 16 ka. 01 no. 134 supply, installing testing and commissioning in replacement of factory made and tested ( including cpri test cetified ) outdoortype floor mountedltpanel board, cubical type suitable for 415 volts 3 phase, 4 wire 50hz, ac supply system having busbar chember with insulated al busbar of rating min. 1.5 times the rated capacity of incomer mccb for phaseinstalled on porcelin / smc insulators. the panel shall be dust and vermin proof ip 54 class protection and made out of 3.15 mm thickcrca ms sheetpowder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with aproaches for cable entry with double door shutter and locking arrangementsincluding internal wiring with pvc insulated stranded copper conductor cable frls is 694 sheathed 1100v grade of appropriate size complete all as specified and directed by engineer in charge.the panel shall be comprising of following: incoming ( i ) mains mccb 4 pole 125 amps with adjustable setting, 415 volts with breaking capacity 36 ka. 01 no. ( ii ) digital type voltmeter 0 500 volts and with selector switch 01 no. ( iii ) digital amp meterwith cts & built in selector switch 01 no. ( iv ) indication lamp ryb 01 set.outgoing ( i ) mccb 4 pole 40 amps, 415 volts with breaking capacity 16 ka. 03no. ( ii ) mccb 4 pole 63 amps, 415 volts with breaking capacity 16 ka. 01 no. 135 supply, installing testing and commissioning in replacement of factory made and tested ( including cpri test cetified ) outdoortype floor mountedltpanel board, cubical type suitable for 415 volts 3 phase, 4 wire 50hz, ac supply system having busbar chember with insulated al busbar of rating min. 1.5 times the rated capacity of incomer mccb for phaseinstalled on porcelin / smc insulators. the panel shall be dust and vermin proof ip 54 class protection and made out of 3.15 mm thickcrca ms sheetpowder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with aproaches for cable entry with double door shutter and locking arrangementsincluding internal wiring with pvc insulated stranded copper conductor cable frls is 694 sheathed 1100v grade of appropriate size complete all as specified and directed by engineer in charge.the panel shall be comprising of following: incoming ( i ) mains mccb 4 pole 315 amps with adjustable setting, 415 volts with breaking capacity 36 ka. 01 no. ( ii ) digital type voltmeter 0 500 volts and with selector switch 01 no. ( iii ) digital amp meterwith cts & built in selector switch 01 no. ( iv ) indication lamp ryb 01 set.outgoing ( i ) mccb 4 pole 125 amps, 415 volts with breaking capacity 16 ka. 02no. ( ii ) mccb 4 pole 160 amps, 415 volts with breaking capacity 16 ka. 02no. ( iii ) mccb 4 pole 200 amps, 415 volts with breaking capacity 16 ka. 01 no. 136 supply and fix cable duct cover made of iron of size 320mm x 800 mm of thickness 3.0 mm complete all as specified and directed by engineer in charge. 137 m&lfor providing, pcc 1:3:6 type c 1 using 20 mm graded stone aggreat, for damaged earth pit chamber with fair finish internal surface of concrete chamber of earthcomplete all as specified and directed by engineer in charge. 138 s & f rubber insulation mat of size 1.8 mtr x0.9mtr wide 19mm thick red colour isi marked embozzed for up to 15 kv complete all asspecifiedand as directed by engineer in charge. 139 m&l for painting of water supply pipe lines of any size & length upto20 rm of both pump houses with two coat of synthetic enamal paint of any tint and highlighting the incoming and outgoing water pipes from pumphouse by making the directional aerrows & writing alphabets i & o ( not less than 5 cm height ) with any light colour paint complete all as specified and directed by engineer in charge. 140 supply and fixing led light fitting 1x16 watt flameproof, cmri certified recommended for gas / vapor group of iia & iiib, zone 1 & 2 and ip 65 protection with die cast aluminum hosing with heat resistant toughened glass with led tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by engineer in charge. 141 supply and fix in replacement switch flame proof rotary type with termination box in lm6, 16a, single pole 250v complete all as specified and directed by engineer in charge. 142 m&l for chemical analysis of water sample collected from mes borewellto check the tds and impurities level in the sample complete all as specified and directed by engineer in charge. 143 supply and fix in replacement of flame proof exhaust fan 300 mm sweep iron bodywith all accessories complete all as specified and directed by engineer in charge. 144 s&f in replacement of xlpe insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 6 sqmm 2 coreall as specified and directed by engineer in charge. 145 m&lfor providingdisplay board of size 1m x 1m x1 cm madeup with acrylic sheetmaterial consisting ofpump house no 1 & 2ge ( af ) faridabadand mes logo in capital letterat the top complete with fixing arrangements to the wall complete all as specified and directed by engineer in charge. 146 m&lfor providingdisplay board of size 1m x 1m x1 cm madeup with acrylic sheetmaterial consisting ofpower house 11 kv ge ( af ) faridabad in capital letterat the top with fixing arrangements to the wall complete all as specified and directed by engineer in charge. 147 s&f in replacement of pvc copper cable for submersible pump ofsize 6 sqmm 3 core flatcomplete all as specified and directed by engineer in charge. 148 m&l for rectification of leakage of ug water pipe lines of size 80 to 150 mm bore of any description such as ci / di / gipipe line at any location including necessary excavation, earth work, dewatering, cutting existing pipe lines including repairs with suitable flanges, joints or any other material complete all as specified and directed by engineer in charge. 149 all as per item no 148 above but but for size of 15 mm to50mm dia pipe line complete all as specified and directed by engineer in charge. 150 m&l for rectification of leakage complaints of sluice valves by opening removing gland plate and pumping / taking water from water pit and proving gland packing and refitting by replacing worn out bolts, nuts and washers complete all as specified and directed by engineer in charge.note: bolts, nuts and washers will be paid under relevant items of schedule 151 m&l for dewatering the existing u / g sump of 25000 ltrs capacity and cleaning the internal surface of sump for removingscales, funges, mud and other foreign material , scrubbing with water using wire brush and watering the surfaces with mixture of bleaching powder and water , finally washing with fresh water and treating with one coat of lime wash to internal wall and bottom surfaces etccomplete for one time, writing in enamel paint note in block capital letter as cleaned on ( date ) and due date etc, height not less than 5 cm complete all as specified and directed by engineer in charge. 152 repair maintainance of oil cooled servo voltage stablizer of capacity400 to 630 kva 3 phase by isolating , disconnecting of input / output , supply cable, opening of top of voltage stablizer, detecting of fault , u / s component in control panel / dimmerstat / pcb etc, cleaning of serviceable parts / component all as specified and directed. note: the replacement spare parts shall be measured and paid separately complete all as specified and directed by engineer in charge. 153 supply only spare part of the voltage stablizer 400 / 630 kvacomplete all as specified and directed by engineer in charge as following: rc network 154 ac synchronous motor 10 kg 155 spring loaded finger 156 microproccessor based eletronic control board 157 demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but including ashlar facings, dressed stonework and precast concrete articlescomplete all as specified and directed by engineer in charge 158 m&l for brickwork with subclass b bricks ( old size bricks ) , straight or curved on plan exc 6m mean radius, built in cm 1:6 complete all as specified and directed by engineer in charge 159 all as per item no 158 above here in but except bricks complete all as specified and directed by engineer in charge 160 m&l for brick work with sub class ‘b’ bricks ( old size brick ) straight or curved on plan to any radius in half bricks thick walls, built in cm 1:4 complete all as specified and directed by engineer in charge 161 m&l for cutting holes exc 400 sq cm but n exc 0.10 sqminto or through brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete complete all as specified and directed by engineer in charge 162 m&l for making good in cm 1:4 under cills or over arches, lintels and bressummers. including allpinning when necessary complete all as specified and directed by engineer in charge 163 taking down cement plaster of any description on concrete surfaces such as soffit of rcc slab, chajjas and brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by engineer in charge 164 m&l, rendering 15mm thick in cm 1:4 onof brick work or concrete surfacefinish ever and smooth ( w / o using extra cement ) incl wpc as per user manual at any height etc complete all as specified and directed by engineer in charge. ( wpc will be measured and paid separately ) . 165 supply only liquid water proofing compound complete all as specified and directed by engineer in charge 166 m&l for rendering 5 mm thick in cement and sand mortar 1:3 onother than fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth on ceilings, complete all as specified and directed by engineer in charge 167 m&l for rendering 15 mm thick cement plaster in cm 1:6 onbrick work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed by engineer in charge 168 m&l for 3mm thick wall care putty on wall complete all as specified and directed by engineer in charge. 169 m&l for 3mm thick wall care putty on ceiling complete all as specified and directed by engineer in charge. 170 m&l for preparation of new plastered or concrete surfaces of walland applying two coats of cement base paint upto triple storey height, complete all as specified and directed by engineer in charge. 171 m&l for preparaing old surface ( plastered or unplastered ) by washing, rubbing down and stopping of painted surfaces of walls and applying one coat of cement base paint, complete upto triple storey height, all as specified and as directed by engineer in charge 172 m&l for preparation of new plastered surfaces of walland applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed by engineer in charge. 173 m&l for preparaing old surface ( plastered or unplastered ) by washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of oil bound distemper on walls, complete all as specified and as directed by engineer in charge 174 m&l for preparaing old surface ( plastered or unplastered ) by washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of oil bound distemper on ceilling surfaces, complete all as specified and as directed by engineer in charge 175 m&l for preparaing new surface ( plastered or unplastered ) by washing, rubbing down and stopping of distempered and applying 2 coat of white wash on ceiling, complete all as specified and directed by engineer in charge 176 m&l for non skid ceramic tiles 7 to 8 mm thick any coloured / printed ( square / rectangular ) area of each tile exc 0.06 sqm but not exc 0.18 sqm as in floor of shade & designed as approved by ge, set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles, over 15 mm thick screed bed in cement mortar ( 1:4 ) in floors, incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed by engineer in charge 177 m&l for glazed ceramic tile 450 x 300 x 06 7mm thick ( coloured ) on vertical surfaces such aswall, dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 10 mm thick screed bed in cement and sand mortar 1:4, and dismantlling of existing tiles complete all as specified and as directed by engineer in charge. 178 taking down and refixing of shuttersin same openingafter easing and adjusting of any description exc 1 sq. m and n exc 2 sq. m each including resecuring / changing of builders hardware complete all as specified and directed by engineer in charge 179 m&l for 18 to 20 mm thick granite ( of any type ) work ( table rubbed and polished ) in steps, jambs, pillars, windowcills, cooking platforms, wash basin platformand like in cement mortar ( 1:4 ) including pointing in white cement ( 1:2 ) using marble dust with admixture of pigment to match with marble shade complete all as specified and directed by engineer in chargenote : 1. contractor shall be bounded to carryout repair / maint upto g+3 storey building and the rate shall be deemed including scafolding / double scafolding, safety equipments and misc accessories....

Military Engineer Services - Haryana

34996897 special repair of equipment shed no g 149, g 150, g 151 g 152 of 140 ad regt and provision of drainage from offrs mess bldg no p 144 to main drain in b area, allenby line of age br i under ge ( south ) ambala cantt material and labour for brick work with sub class ‘b’ bricks, straight or curved on plain exceeding 6 metre mean radius in cement mortar ( 1:6 ) including demolition of brick work built in cement mortar including demolition of old brick / stone masonry built in cement mortar of any description including all quoins, archs, pillars etc complete all as specified and directed. 2 material and labour for brick work ( except bricks ) straight or curved on plan exceeding 6 metre mean radius built in cm 1:6 ( old size brick ) including demolition of old brick masonry built in cement mortar of any description including all quoins, archs, pillars etc complete all as specified and directed. 3 taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. 4 material and labour for rendering 15 mm thick on any faces of old brick work in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed. 5 material and labour for rendering 15 mm thick on fair faces of new brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and directed. 6 material andlabour for preparation of exposed brick wall surface by cleaning the surface wire brush to remove all dirt / loose materials from the bricks and from the joints between the bricks. prepared surface should be then washed with diluted hcl acid ( dilution ratio of 1:50 ) for three times in a day for two days. after acid wash surface should be allowed to be air dried for one day. note : further treatment over the surface so achieved will be carried out only after approved of the same by ge. 7 material and labour for carrying out efflorescence treatment to unplastered wall surface comprising of the following specifications and sequence with and including 15 mm thick rendering in cm 1:4 finished even and smooth without using extra cement : ( a ) prime the prepared surface with one of the following product mixed with cement in 1:1 ratio as bonding agent : ( i ) pidicrete urp of m / s pidilite. ( ii ) sika latex of m / s sika. ( iii ) nitobond sbr latex of m / s fosroc. ( b ) immediately after priming the surface pmm ( polymer modified mortar ) to be applied “by hand” while the prime is tacky. pmm should be prepared by mixing one of the following compounds in cement mortar 1:3 as per manufacturer’s instructions: ( i ) pidicrete urp of m / s pidilite. ( ii ) sika latex of m / s sika. ( iii ) nitobond sbr latex of m / s fosroc. ( c ) pmm surface should be allowed to dry for one day. after that it should painted with two coats of one of the following compound mixed with cement only in ratio of 1 ( selected compound ) : 1:5 ( cement ) : ( i ) pidicrete urp of m / s pidilite. ( ii ) sika latex of m / s sika. ( iii ) nitobond sbr latex of m / s fosroc. ( d ) now apply two coats of one of the following compound over the surface. these compounds are to be used as per manufacturer’s instructions: ( i ) pidifin 2k of m / s pidilite. ( ii ) brush coat of m / s sika. ( iii ) brush bond of m / s fosroc.note : both coats should be perpendicular to each other and gap between two coats shall be minimum 6 hours. ( e ) sprinkle loose coarse sand after second coat while surface is tacky.note: ( i ) the item will be executed by authorized applicator only of the selected / approved company. contractor shall submit details of authorised applicator for approval of ge before commencement of work in respect of above item. ( ii ) every stage of work will be approved by ge, then only next layer will be executed by contractor. 8 material and labour for rough cast plaster with and including 15mm thick rendering in cm 1:3 on brick wall or concrete surface as specified in clause 14.22 of ssr part i complete all as specified and directed.note: ( i ) after applying the under coat of cement and sand mortar 1:3 not less than 10 mm thick andwhile it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravelaggregate ( which is generally of size between 6 to 12 mm depending on the texture required ) mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even. ( ii ) the mix of cement and sand shall be made slightly wetter than normal for rendering to ensurethat larger aggregates are thoroughly covered 9 material and labour for preparation of new plastered surfaces of walls and applying three coats of white wash on wall, complete all as specified and directed. 10 material and labour for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primeron walls complete all as specified and directed. 11 material andlabour for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper with hand roller, over a coat of alkaline resistant primer over a coat of wall care puttynot less than 1mm thick as per manufacturers instruction complete all as specified and directed. 12 material andlabour for preparation of old plastered surfaces of walls and applying two coats of white wash complete all as specified and directed. 13 material and labour preparation of old plastered surfaces of walls and applying one coat of cement base paint complete all as specified and directed. 14 supply andfixing of pre painted galvalume aluminium zinc coating gi based corrugatedsteel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa tensile strength as in roof covering / cladding to wall, fixed with self tapping screws or j type hooks including rubber washer etc complete including dismantling asbestos cement corrugated or semi corrugated sheets etc; complete all as specified and as directed. 15 supply andfixing of pre painted galvalume aluminium zinc coating gi based galvanised plain mild steel sheeting 0.50 mm thick of any colour, having 550 mpa tensile strength as in roof covering / ridges and fixed with self tapping screws or j type hooks including rubber washer etc complete including dismantling asbestos cement corrugated or semi corrugated sheets etc; complete all as specified and as directed. 16 dismantling timber scantling 40 sq. cm and over in section, in any position of unframed / framed work complete all as specified and directed. 17 material and labour for preparation of old painted steel surfaces of any description not otherwise described, over 10 cm in width or girth and applying one coat of synthetic enamel paint with approved shade complete all as specified and directed. 18 material and labour for taking down of rolled mild steel roof trusses ( framed ) of clear span above 08.00 metre and upto 12.00 metre any type, taking in safe costudy and refixing the same with and including using new nut bolts, welding & distance pieces, cleats etc., after completion of truss connected repair work etc complete all as specified anddirected. note: any damage to the existing truss during dismantling or refixing etc, shall be made good by the contractor with the same specifications as per existing work, without any extra cost to the govt. 19 dismatling of mild steel beam, purlin of existing truss andrefixing the same ( using nut bolt, welding ) rolled mild steel plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats & other connections gde fe410 0 or fe 310 o complete all as specified and as directed. 20 supply and fixing of rolled mild steel sections as in main & cross beams, hip & jack rafters; purlins where connected to common rafters & running rails & guides for sliding doors; fixed with angle cleats or other connecting plates gde fe410 0 or fe 310 o complete all as specified and as directed. 21 supply andfixing of rolled mild steel work in roof trusses ( framed ) , trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing ( beam, tee, angle, channel or flat sections ) including distance pieces, cleats etc., quality confirming tofe 410 w ( gde e 250 ) quality a, complete, all as specified and as directed. 22 supply andfixing of mild steel plates ( plain or chequered ) channels, square cut or notched ( ordinary and counter sunk ) forming holes, with riveted, bolted or welded attachment conforming to grade fe 410 ( gde 250 ) , complete all as specified and directed. 23 material and labour for steel screw bolts, machine made, dia of neck 11 to 15mm with hexagonal or square head one end and screwed the other or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut exceeding 22.5 cm and not exceeding 30cm long, complete all as specified and directed. 24 material and labour for two coats of synthetic enamel paint on steel surfaces over a coat of red oxide primerincludingpreparation of new steel surfaces of any description not otherwise described over 10 cm width or girth, complete all as specified and as directed. 25 material and labour for hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 26 material and labour for 150mm thick pcc 1:2:4 type b2 using 40mm graded mechanically crushed stone aggregate as in hardstanding / paths, finishing the concrete surface even and smoothwithout using extra cement including formingjoints and fillingwith mixture of bitumen and sand in ratio ( 1:1 ) by weight including necessary formwork etc and including demolition of existing old cement concrete in ground floors and pavings n.exc 15cm thickness ( below or above ) ground level complete all as specified and directed. 27 material and labour for 50mm thick pcc ( 1:3:6 ) type c 1 using 20mm graded mechanically crushedstone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture including demolition of cement concrete in ground floor and pavings not exceeding 15 cm below or above ground level etc complete all as specified and directed. 28 surface excavation not exceeding 30 cm deep, averaging 15 cm deep and getting out in soft / loose soil, complete all as specified and directed. 29 material and labour for 100mm thick pcc ( 1:4:8 ) type d 2 using 40mm graded mechanically crushed stone as in sub base of floor / hard standing finished, complete all as specified and directed. 30 material and labour for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of m 40 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size / shape, made by table vibratory method using pu mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed 31 material and labour for providing and laying of precast pcc solid concrete block, grade c confirming to is 2185 ( part i ) 2005 of 45 cm high, 10 cm thick and of suitable width including chamfers, weatherings, throating etc as in kerb continuous edging jointed in cement mortar 1:4 and struck flush pointing as the work proceeds and finishing with neat cement flush joint, complete all as specified and directed. 32 material andlabour for premium quality, joint free, non skid coloured ceramic tiles, area of each tile exc 0.11sqm but not exceeding 0.18 sqm, 7 to 8 mm thick as in floor, set and jointed in neat cement slurry @ 3.00 kg / square metre and pointed in white or coloured cement to match the surface over and including15mm thick screed bed or layer in cement mortar ( 1:4 ) including dismantling of existing tiles etc including cement mortar bedding ( but not backing ) andrubbish off the premises complete all as specified and directed. 33 material and labour forpremium quality coloured glazed ceramic tiles ( 300x 450x 7mmthick ) in vertical surfacesand jointed in neat cement slurry @ 3.00 kg / square metre and pointed in white or coloured cement to match including rendering 10mm thick in cement plaster 1:3 including dismantling of old floor or wall tiling including cement mortar bedding and removing the rubbish outsidethe defence land complete all as specified and as directed. 34 material and labour for machine cut kota stone slab 20 25 mm thick ( size of each stone not less than 55cm x 55cm ) , laid in flooring, over and including cement screed bed 20mm thick in cement mortar ( 1:4 ) base set and jointed in neat cement slurry @ 3.00 kg / sqm and pointed in white or coloured cement to match the surface mixed with pigment to match shade of the slab over and including 25 mm thick cement concrete type b 0, 1:2:4 ( 12.5 mm graded aggregate ) as in levelling course, including cutting, waste, rubbing and polishing ( mirror finish ) including dismantling of existing stone slab / tiles etc including pcc and cement mortar bedding andrubbish off the premises complete all as specified and directed. 35 material and labour for machine cut kota stone slab 18 20 mm thick ( size of each stone not less than 55cm x 55cm ) , laid on vertical surfaces of skirting / dado, over and including cement screed bed 15 mm thick in cement mortar ( 1:3 ) and set and jointed in neat cement slurry @ 3.00 kg / sqm and pointed in white or coloured cement to match the surface mixed with pigment to match shade of the slab including cutting, waste, rubbing and polishing ( mirror finish ) including dismantling of existing stone slab / tiles etc including cement mortar bedding ( but not backing ) andrubbish off the premises complete all as specified and directed. 36 supply and fixing in repair of 5.5mm thick looking mirror of selected quality, beveled edge 450mmx600mm glass mounted on 6mm thick ac building board with aluminiumbeading andrubber packing and fixed to wall with wooden plug with chromium plated brass screw and cup washer complete all as specified and directed. 37 supply & fixing ( in repair ) vitreous china wash down water closet pedestal pattern ( ewc ) , white including connection to trap and to flushing pipe with ‘p’ or ‘s’ trap, making good to floor, plastic water closet seat cover with mild steel chromium plated hinges and chromium plated jet spray with 1.5 meter flexible ldpe pipe jointed with pipe complete all as specified and directed. 38 supply and fixing in repair of health faucet with 8mm dia, 1metre long flexible tube and wall hook complete all as specified and directed. 39 supply & fixing in repair of vitreous china wash hand basin white flat back of size 550x440mm including ci brackets and 15mm chromium plated pillar tap, pvc connection 450 mm long having ptmt nuts and 32 mm dia brass chromium plated waste coupling and making good to disturbed portion including32 mm dia pvc waste pipe etc., complete all as specified and directed. 40 supply and fixing in repair of 10 litre capacity virgin polypropylene cistern, white, isi marked, coloured at low level complete including supply and fixing45 cm pvc connection, pvc bend / flush pipe andmaking all connection , and removal old complete all as specified and directed. 41 supply and fixingin repair of vitreous china half stall urinal complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, pvc waste pipe, flush pipe, cp waste fitting, grating and union for discharge pipe complete all as specified and directed. 42 supply and fixing in repair of cp bib tap screwed down high pressure, long body, cast copper alloy, chromium plated with crutch or butterfly handles screwed down suitable for 15mm bore pipe or union, complete all as specified. ( note : weight of bib tap shall not be less than 0.575 kg ) 43 supply and fixing of gi tubing, isi marked, 15mm bore, `medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors including necassary cutting / chasing / pinning in wall and making good the disturbed surfaces as per existing whereever required, including taking down of old tubing as existing at site and removal, complete all as specified and as directed. 44 supply and fixing of gi tubing, isi marked, 20mm bore, `medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors including necassary cutting / chasing / pinning in wall and making good the disturbed surfaces as per existing whereever required, including taking down of old tubing as existing at site and removal, complete all as specified and as directed. 45 refixing old serviceable steel water tubing of 15 mm bore, in new or old position, any grade, including s&f new fittings as required, fixed to walls and ceilings or laying in floors including necassary cutting / chasing / pinning in wall and making good the disturbed surfaces as per existing whereever required , including taking down of old tubing as existing at site and removal, complete all as specified and as directed 46 refixing old serviceable steel water tubing of 20 mm bore, in new or old position, any grade, including s&f new fittings as required, fixed to walls and ceilings or laying in floors including necassary cutting / chasing / pinning in wall and making good the disturbed surfaces as per existing whereever required , including taking down of old tubing as existing at site and removal, complete all as specified and as directed 47 supply and fixing in repairs, water storage tank of 500 ltr capacity, hdpe double layer, isi marked, fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, brass valve 20 mm high pressure with polythene float and flynut, isi marked, screwed andsuitable for iron pipe 20 mm bore complete all as specified and directed. note: make of tank shall be engraved on the tank. 48 supply andfixing in repair of angle valve, 15mm dia chromium plated, cast copper alloy, screwed down, high pressure with capstain head, heavy with adjustable wall flange, and removal old complete all as specified and directed. 49 supply & fixed in repair of stop cock, fancy type, chromium plated, long shank and cup ( concealed type ) screwed down high pressure with crutch or butterfly handle screwed both ends suitable for 15mm bore pipe, complete all as specified and directed. ( note : weight of stop cock shall not be less than 0.575 kg ) 50 supply and fixingin repair of chromium plated shower rose with swivel joints and including fixed to gi tubing 15mm bore size of shower not less than 125mm complete all as specified and directed. 51 supply and fixing in repair of chromium plated soap dish with fitting fixed with brass screws complete all as specified and directed. 52 supply and fixing in repair of 20 mm dia gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed. 53 supply andfixing in repair of brass chromium plated tubular towel rail, 20 mm dia, ‘d’ type 60 cm long between flanges complete all as specified and directed. 54 excavating in trenches, not exceeding 1.50 m wide & not exceeding1.5m depth & getting out in hard / dense soil complete all as specified and directed. 55 supply and fixing of pvc ( swr ) 75 mm pipe single socket in any length with rubber ring joints laid in floor or trenches includingdismantling ofpipes of any description any length etc complete all as specified and as directed. 56 supply and fixing of pvc ( swr ) 110 mm pipe single socket in any length with rubber ring joints laid in floor or trenches includingdismantling ofpipes of any description any length etc complete all as specified and as directed. 57 supply and fixing of pvc ( swr ) 110 mm pipe single socket in any length with rubber ring joints fixed to wall with ms clamps including dismantling ofpipes of any description any length etc complete all as specified and as directed. 58 supply and fixingin repair of 110 mm bore pvc ( swr ) bend with access door including jointing with solvent cement, complete all as specified and directed. 59 supply and fixingin repair of pvc ( swr ) 110 mm to 75 mm dia, reducers complete all as specified and directed. 60 supply and fixing in repair of 110 mm bore pvc ( swr ) , junction single t ( equal or unequal ) , including jointing with solvent cement, complete all as specified and directed. 61 supply and fixing in repair of pvc ( swr ) floor trap 75mm dia plain with pvc grating including jointing with solvent cement complete all as specified and directed. 62 taking down chowkats or frames with shutter, areanot exceeding 1.50 square metre ( w / o taking off shutters from frames ) and removing from site, including cutting holes in wall / concrete for taking out existing hold fasts and making good the disturbed portion of jambs andadjoining surfacesin cm ( 1:3 ) and finishing the surfaces to match with existing finish complete all as specified and directed. 63 taking down chowkats or frames with shutter, areaexceeding 1.50 square metrebut not exceeding 4 square metre ( w / o taking off shutters from frames ) and removing from site, including cutting holes in wall / concrete for taking out existing hold fasts and making good the disturbed portion of jambs andadjoining surfacesin cm ( 1:3 ) and finishing the surfaces to match with existing finish complete all as specified and directed. 64 supply and fixing of pressed steel frames for doors of size 125 x 60mm, 1mm thick, with one or more rebates including, hold fasts of 25mm x 4mm fi, 25cm long, 6 nos in each chowkhat, necessary lugs, 3 nos 100 mm ms butt hinges medium weight, cold rolled, welded for each shutters of frame, lock strike plate, including sanding, tarring backs of chowkhats, pcc 1:3:6 type c 0filling in frame and for holdfast, 2 nos 12 mm dia ms tie bars at the bottom of frame and one shop coat of red oxide primer etc complete all as specified and as directed. 65 supplyand fixing of factory made 35 mm thick, second class hard wood rail and style, plain framed, panelled shutter ( two panel ) with lock rail and panel of 9 mm b.w.p commercial ply or 12 mm veneered particle board with commrcial veneering on both faces ace, size of rails and stiles asper is 1003 ( part i ) kiln seasoned and chemical pressure treated complete all as specified and directed. 66 supply and fixing of iind class ( hollock ) factory made 35mm thick glazed skelton door shutters, open rebated and prepared to receive glass, gauge etc. divided into squares edges of framing, plain, chamfered or rounded, mitred fitted with cut and mitred beads for securing glass / gauge etc. with sizes of members of shutters as specified in para 8.24 ( a ) of ssr 2009 ( part i ) , complete all as specified and directed. 67 supply and fixing factory of made pvc hollow door frame of size 50mm x 47mm with wall thickness of 5 mm made out of extended 5 mm rigid pvc foam sheet cut at corner and jointed with 02 nos, 150 mm long brackets of size 15 mm x 15 mm mild steel square tubes 19 gauge including vertical door profiles reinforced with 19 mm x 19 mm steel square tube of 19 gauge ( epdm ) rubber gasket weather seal provided through out the frame and fixed to wall with 65 / 100 mm long mild steel screws through the frame by using pvc fasteners ( minimum of 04 nos of screws to be provided for each vertical numbers & minimum 02 nos for horizontal member ) complete all as specified and directed. 68 supply andfixing factory made solid pvc moulded door shutter, 28 to 30 mm thick ( stiles ) with 2, 4 or 6 raised panel design with 2 mm thick moulded pvc sheet on the front face & 2 mm plain colour pvc sheet on back face includingfixing in frame at site with 03 nos ss hinges, 02 nos aluminium tower bolt 150 mm, 02 nos aluminium handle 150 mm for each shutter all as per specification & drawing complete all as specified and directed. 69 supply and fixing in repair of steel window box type using erw hollow p section comprising double frame for and including gauged and glazed skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs etc. all as shown on drawing no. td 219 ( c ) sheet 1 / 3 to 3 / 3 and td 220 ( c ) sheet 1 / 3 to 3 / 3 as applicable including pcc ( c o , 1:3:6 using 12.5 graded agg ) bed blocks for hold fasts and one shop coat of red oxide primer etc complete all as specified and directed.note: ( i ) for the purpose of measurement & payment double shutter with frame shall be considered as one unit. ( ii ) unit rate quoted against this item shall also include the iron mongery , grills 10mm square bars. ( iii ) only glazing, wire mesh & painting grill shall be measured & paid for separately ) 70 supply and fixingin repairs of mild steel ventilator of section framed fixed type and fixed wire mesh with flat bends 10 mm x 3 mm with nuts / bolts complete including fixing lugs, necessary pcc 1:3:6 type c 1 for filling bed blocks of hold fasts / lugs, etc complete all as specified and directed. 71 supply and fixing of mild steel pressed handle, 150mm long, oval type, stove enameled black, complete all as specified and directed. 72 supply and fixing of mild steel barrel tower bolt stove enamelled black with bright bolt 200mm long complete all as specified and directed. 73 supply and fixing of250 mm long mild steel sliding door bolts , plate type, stove enamelled black, with bright bolt not less than 12mm with and including a minimum of 6 bolts and nuts , four on bolt plate and two on staple plate complete all as specified and directed. 74 returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in soil complete all as specified and directed. 75 removing surplus excavated material ( soil ) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed. 76 material and labour for pcc 1:3:6 type c 2 using 40mm graded mechanically crushed stone aggregate as in foundation filling, mass concrete, sub base etc. complete all as specified and directed 77 material and labour for plain cement concrete 1:2:4 type b 1 ( using 20mm graded mechanically crushed stone aggregate ) as in surface channels and drains, complete all as specified and as directed. 78 material and labour for pcc 1:2:4 type b 1 ( using 20 mm graded mechanically crushed stone aggregate ) ascopings, bed plates, kerbs, and other bands and the like, finished the surface fair andeven, including necessary form work etc including demolition of existing cement concrete of any description and in any position complete all as specified and directed. 79 material and labour for providing and laying of precast cement concrete solid concrete block, type b 1, 1:2:4 ( using 20mm graded stone aggreagate ) confirming to is 2185 ( part i ) 2005 of 30 cm high, 10 cm thick and of suitable width including chamfers, weatherings, throating etc as in kerb continuous edging jointed in cement mortar 1:4 and struck flush pointing as the work proceeds and finishing with neat cement flush joint etc complete all as specified and directed. 80 dismantling / taking down carefully aluminium / copper point wiring ( light, fan, socket or power ) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of wall, floors, ceiling etc to match with the existing surfaces with matching obd / white wash / distemper complete all as specified and as directed. 81 material and labour for concealed point wiring with 1.50 sqmm single core pvc insulated, unsheathed cable frlsh, 1100 volt grade with multi stranded copper conductor drawn through and including medium grade, isi marked, pvc conduit not less than 25 mm dia with frlsh accessories, concealed and including provision of 1.50 sqmm single core pvc insulated, unsheathed cable frlsh 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to is 5139 ( pt i ) of 1969 and is:14772 2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washersand making goodthe disturbed surfaces as per existing for one light / fan point / bell point controlled by one switch complete all as specified and directed. notes : ( i ) the quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall / pillars / columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. the portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories / fittings. ( ii ) point wiring & earth wire shall be connected to each & every flush / sunken box. ( iii ) all screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates. 82 description all as per item no 81.00 above but for socket out let point 5 amps on same board complete all as specified and directed. 83 description all as per item no 81.00 above but for socket out let point 5 amps on independentboard complete all as specified and directed. 84 description all as per srl item no 81.00 above but point wiring for one socket out let 15&5 amps ( independent ) controlled by one switchwith using 2.5 sq mm ( nominal area ) stranded copper conductor complete all as specified and directed. 85 supply and fixing of switch piano 6 amps, flush type, single pole, one way, 230 volt , ac supply, isi marked, complete all as specified and directed. 86 supply and fixing of switch piano 15 amps flush type one way 230 volts, 50 hz, ac supply, isi marked, complete all as specified and directed. 87 supply and fixingsocket outlet 3 pin 5 amps, 230 volts flush type , isi marked, complete all as specified and directed. 88 supply and fixing of socket outlet 2 in 1, 6 / 16 amps, 5 pin 230 volt flush type, isi marked complete all as specified and directed. 89 supply and fixing of ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and directed. 90 supply and fixing offan regulator electronic step type , 230 volts, ac supply, suitable for ceiling fan any type / make / sweep, complete all as specified and directed. 91 supply and fixing lamp holder, pvc / polycarbonate type with back plate suitable for batten fittings, complete all as specified. 92 supply and fixing of led lamp 9 watt suitable for batten holder complete all as specified and directed 93 supply and fixing of double stiff pendants, comprising of galvanised steel or chromium plated brass bell mouth connectors 2 nos. with back plate and 2×1.50 metre long parallel 20mm dia galvanised or stove enamelled screwed steel conduit with two check nuts for fixing tube light fitting and upto 1.5 metre long twin core 0.5 sq. mm copper conductor flexible wire / cable including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. 94 supply and fixing of industrial box channel for fixing of led tube rod, in crca body suitable for 2x18 / 20 watt led tube, high efficient, ac 220 240 volts, 50 hz and connecting with copper conductor flexible cable of size 0.50 sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. note : ( i ) tube rod shall be measured and paid for separately. ( ii ) channel must be get approved from engr in charge to check fesibilty i.e. one end contact or two end contact. 95 supply and fixing of channel for fixing of led tube rod, in crca body suitable for 18 / 20 watt led tube, high efficient, ac 220 240 volts, 50 hz and connecting with copper conductor flexible cable of size 0.50 sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. note : ( i ) tube rod shall be measured and paid for separately. ( ii ) channel must be get approved from engr in charge to check fesibilty i.e. one end contact or two end contact. 96 supply and fixing of 18 w / 20w polycarbonate led tube light, environment friendly, high efficient, t8 with aluminium extrusion heat sink for optimum performance with high luminous efficiency and easy and taking down existing tube light and removal complete all as specified and directed. note: tube rod must be get approved from engineer in charge to check fesibilty i.e. one end contact or two end contact for fixing in existing led fittings. 97 supply and fixing ofbulk head light fitting, 15 watt, energy efficient withlamp 15 watt with provision of 2 / 3 core pvc copper conductor cable 0.5 sqmm size from ceiling rose to light fitting completeincluding disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. 98 supply and fixing in repair bracket for security light made up of 25mm dia, 0.9 metre long gi pipe, light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed. 99 supply and fixing led security light luminaire 50 watt , pressure die cast aluminum housing, toughened heat resistant glass, ip65 protection, better optics for uniform distribution with multiplte leds not less than 2 w each and having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any position complete all as specified and directed. 100 supply and fixing led high efficient bay light 50 watt, die cast aluminum housing, toughened heat resistant glass, ip66 protection, better optics for uniform distribution with all accessories internally pre wired and including connecting up with two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any position complete all as specified and directed. 101 supply and fixing of sheet metal enclosures vertical distribution board vtpn, ( mccb db ) 4 ways, double door, 415 volts with 200 amps rated bus bar ip 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and includingmccb 4 pole thermal release type, 100 amps, 16 kaas incomer and mcbsas out going complete with making suitable size of ms cabinet 2 mm thick dully grouted on the wall ( flush ) with opening arrangement including making connections with suitable size of lugs / thimbles / glands and making good the disturbed surface matching with existing surface including taking down existing unserviciable mccb / dbs including mcbs complete all as specified and directed. 102 supply, installation, testingofspn distibution board 8 way, double door , ip 43, as per is 8623including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, pan assembly for easy installation and also incoming and outgoing connections with suitable size of lugs / thimblesincluding taking down existing unserviciable mcb / dbs including mcbs complete all as specified and directed. 103 supply, installation, testingofspn distibution board 4 way, double door , ip 43, as per is 8623including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, pan assembly for easy installation and also incoming and outgoing connections with suitable size of lugs / thimblesincluding taking down existing unserviciable mcb / dbs including mcbs complete all as specified and directed. 104 supply and fixing of mcb single pole, 240 volts, 50hz , breaking capacity 10ka, b curve 6 to 32 amps, including connection with suitable size copper lugs complete all as specified and directed. 105 supply and fixing of mcb single pole, 240 volts, 50hz , breaking capacity 10ka, b curve 40 to 63 amps, including connection with suitable size copper lugs complete all as specified and directed. 106 supply and fixing of mcb single pole and neutral, 240 volts, 50hz , breaking capacity 10ka, b curve 40 to 63 amps, including connection with suitable size copper lugs complete all as specified and directed. 107 material and labour for concealed sub main wiring with two single core frlsh pvcinsulatedunsheathed copper conductor cable 2.5 sqmm drawnin and including rigid non metallic pvc medium grade 25 mm dia concealed conduit with accessories onwall or ceiling withone additional pvc insulated , strandedcopper conductor frlshof 2.5 sqmm, green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete all as specified and directed.note : 3 run of cable and 1 run ofconduit shall be measured as 1 unit. ( ii ) the quoted rates shall be deemed to be inclusive for cutting chasesin wall / pillars / columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. the portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories / fittings. 108 material and labour for concealed sub main wiring with two single core frlsh pvcinsulatedunsheathed copper conductor cable 4.00 sqmm drawnin and including rigid non metallic pvc medium grade 25 mm dia concealed conduit with accessories onwall or ceiling withone additional pvc insulated , strandedcopper conductor frlshof 4.00 sqmm, green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete all as specified and directed.note : 3 run of cable and 1 run ofconduit shall be measured as 1 unit. ( ii ) the quoted rates shall be deemed to be inclusive for cutting chasesin wall / pillars / columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. the portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories / fittings. 109 material and labour for concealed sub main wiring with two single core frlsh pvcinsulatedunsheathed copper conductor cable 6.00 sqmm drawnin and including rigid non metallic pvc medium grade 25 mm dia concealed conduit with accessories onwall or ceiling withone additional pvc insulated , strandedcopper conductor frlshof 6.00 sqmm, green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete all as specified and directed.note : 3 run of cable and 1 run ofconduit shall be measured as 1 unit. ( ii ) the quoted rates shall be deemed to be inclusive for cutting chasesin wall / pillars / columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. the portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories / fittings. 110 taking out of unserviceable earthing and material and labour for earthing and material & labour for earthing with galvanised steel earth plate electrode 60cmx 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer ofcharcoal dust and common salt filling in alternate layers and electrode connections by usinggalvanised iron wire 4mmas earthing lead ( upto terminal point ) by means ofbolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm diagi pipe connected to main switch board or main control board and gi pipe medium grade 20mm bore for watering and including funnel , wire mesh, 50 mm thick precast rcc 1:2:4 type b1using 20 mm graded stone aggregate , reinforced with 8 mm dia dedormed / tmt bars 3 nos both way 12 mm dia round bar handle and pcc chamber pit with pcc ( 1:3:6 ) type c 2 using 40mm graded stone aggregate, including excavation and earth work in any type ofsoil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate no 3 ofssr 2009 ( part i ) complete all as specified and as directed. note : ( i ) earth lead wire and its protection pipe upto and including 7.50 mtr only from top of earth electrode are included under this item. ( ii ) on testing if the earth resistance is not obtained within permissible limit, earthing will be re done at no extra cost , till the desired earth resistance is obtained. ( iii ) any joint in earth lead from earth electrode to test point shall not be allowed / permitted. 111 supply, laying and testing of cable xlpe insulated, armoured heavy duty electric cable with standred aluminium conductor, 1100 volts grade, cross sectional area of size 25 sqmm 4 core including dismantling existing any type and any size cable complete all as specified and directed. 112 supply, laying and testing of cable xlpe insulated, armoured heavy duty electric cable with standred aluminium conductor, 1100 volts grade, cross sectional area of size 10 sqmm 2 core including dismantling existing any type and any size cable complete all as specified and directed. 113 supply and fixing in repair of gi protection pipe of 40mmdia light grade for cable protection including all fittings laid in trenches or fixed on pole, complete all as specified and as directed. 114 material and labour for supply and filling sand with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. note: punned thickness shall be measurement & paid. 115 material and labour for brick protection covers over cable using sub class b old size brick laid along length of cable complete all as specified and directed. 116 supply and fixing 1100 volts grade heavy duty cable pvc insulated aluminium conductor, served with inner sheathing of pvc tape and overall pvc sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 16sqmm including all incoming and outgoing connection with proper size of thimble including disconnecting and taking down existing cables etc. complete all as directed and specified. 117 supply and fixing in repair of house service bracket ( hook type ) complete with 3.0 m long gi pipe 40mm dia medium grade pipe, two 90 degree bends. ms hook, stay or guy including fixing clamps etc complete all as specified and directed. 118 note: amount of credit ofrs. 74, 062.00 for retrieved materials is mentioned in schedule of credit page no 19 & 20 of tender documents in pdf form which will be deducted offline while acceptance of tender....

Urban Local Bodies - Haryana

34662882 replacement of burnt cctv racks with equipment’s, damaged cctv cameras, installation of cctv cameras in place of stolen cameras with allied items at various locations under jurisdiction of mc panchkula s / i / t / c of 24 core outdoor fiber termination unit fully loaded ( as per actual basis ) ( make: r&m ) 2 s / i / t / c of cat 6 utp cable outdoor with gelly filled ( 305 mtr roll ) . ( make r&m ) 3 fiber cable joint box 4 s / i / t / c of single mode fiber patch cord ( 3 mtr ) ( as per actual basis ) ( make: r&m ) 5 s / i / t / c of single mode fiber pig tails ( as per actual basis ) ( make: r&m ) ) 6 s / i / t / c of industrial grade 10 / 100 / 1000 mbps 8 port poe switch with 4 sfp combo as per specification ( make: allied telsis ) 7 ( new hsr 24.4.8 ) supply and erection of hot dip galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, integral cable termination arrangement 5 mm thick bakelite base plate on suitable welded ms / gi bracket 32 a four way connector 2 no 10 a sp mcb , end cover and all accessories as supplied by the manufacture including providing rcc foundation of m25 grade ( 1 cement:1 stone aggregate: 2 coarse sand ) i / c excavation, steel reinforcement ( fe 500 ) @80 kg / cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of pcc 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of engineer in charge. ( 24.4.8.2 ) 4 metre long pole with top dia 65 mm and bottom dia 130 mm with base plate of size 225 x 225 x12 mm 8 s / i / t / c of full hd box type cameras: with 12.5 50mm ir corrected lens and ip66outdoor housing with heater and blower with as per specification. ( make: axis ) 9 s / i / t / c of mini gbic sfp module ( as per actual basis ) ( make: r&m ) 10 wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire pvc insulated copper conductor cable1100 volts grade in existing ms / pvc conduit etc as required.1 run of size 1.50 sqmm ( 1 / 1.40mm ) ( new hsr 23.5.6.1 ) 11 s / i / t / c of 1kva online ups with 4 hours backup ( make: apc ) 12 s / i / t / c of 24 core outdoor single mode armorerd off ( as per actual basis ) ( make: r&m ) 13 s / i / t / c of 24 port cat 6 patch panel fully loaded ( make: r&m ) 14 soft soil digging 4ft. minimum with sand & amp; bricks ( as per actual basis...

National Security Guard - Haryana

32789129 operation, repair and maintenance of fire fighting equipments for the year 2022 23 ( sh: maintenance on routine basis ) 1 sub head i pumps & motorspreventive maintenance of the fire as per pump list attached. the agency will undertake the maintenance work of the pumps only through the oem or oem authorized dealer. 2 site, model, make, primer mover & qty of pumps 3 old magzine up150 / 45 ( kbl ) engine driven 01 nos up150 / 45 ( kbl ) motor driven 02 nos cphm40 / 26 ( kbl ) motor driven 01 nos 4 niranjan auditoriumdsm80 / 36 ( kbl ) engine driven 01 nosdsm80 / 36 ( kbl ) motor driven 02nosdb32 / 26 ( kbl ) motor driven 01 nosdb50 / 16 ( kbl ) motor driven 02 nos 5 new building dsm100 / 36 ( kbl ) engine driven 01 nosdsm125 / 40 ( kbl ) motor driven 01nosrkb40 / 12l5 ( kbl ) motor driven 01 nos 6 nagrani bk db50 / 16 ( kbl ) motor driven 02 nos 7 total ( pumps ) 15 nos 8 scope of work covered under the preventive maintenece 9 one visit in each three months will be made by an oem ( kbl ) service person with priorintimation. 10 twobreakdown visits included under amc. 11 complete check up of the pump sets as per kbl standards. 12 check free rotation of pumps. 13 check tightness of casing bolts, foundation bolts, and grease ms fasteners. 14 oil levels, grease in bearings, condition of bearing to be checked and replenished if required ( spare shall be provided by deptt ) 15 vibration, noise, bearing temperature, voltage, speed and pressure to be measured and recorded. 16 alignment of pump set to be checked and in case if required rectification to be carried out and readings to be recorded. 17 coupling bushes, pins, rubber parts to be checked and to be replaced if required. ( spare shall be provided by deptt ) 18 mechanical seal condition to be checked and suitable recommendations to be made. 19 service report will be generated afterevery visit recording data anddetails of above checks. 20 training will be provided to site operators to obtain optimum output & lifeof equipment. 21 overhaulingof the following pump including dismentaling, machining , oiling , greasing , assembling & installation at site includingloading and unloading, to and fro transportation ofpump from nsg campus manesar to the workshop. the work will be done through the oem or oem authorized dealer of the pumps, and the repair work will be given a three month warranty by the oem / authorized dealer. model & make. 22 up150 / 45 or dsm80 / 36 or rkb40 / 12l5.kbl make 23 cphm40 / 26.kbl make 24 db32 / 26 or db50 / 16.kbl make 25 dsm100 / 36 or dsm125 / 40.kbl make 26 replacement of the following spare parts of the existing kbl pump up150 / 45 kirloskar make main fire pump driven by electric motor 90kw / 120hp capacitywith a new one if found defective, including testing, complete as required, including credit for old scrap material which will be retained by the contractor etc., complete as required. thework of the pumps will be done only through the oem or oem authorized dealer. 27 mechanical seal 28 mechanical seal plate 29 sleeve moc bronze ( 17458cq001012 ) 30 set of gasket moc non asbestos 31 o ring moc natural rubber 32 ball bearing 2877 moc ss ( x630900400000 ) 33 wear ring moc bronze ( 1712021991012 ) 34 rewinding of ( from 12.5 hp up to 120 h.p. three phase capacity ) electrical motors including all necessary material and of the same characteristics as original with required size of super enameled copper wire and f class insulation material including dismantling, removing of burnt wires, cleaning of slots, varnishing, assembling, greasing, testing etc. complete as required including credit for old scrap material which will be retained by the contractor etc., complete as required. thework of rewinding of motors will be done only through the oem or oem authorized dealer. 35 sub head iifire alarm system sitc / replacement of addressable manual call point complete as required through authorised dealer or oem ( compatible with est3 or equivalent addressable system ) make edward / apollo / siemens / notifier or equivalent 36 sitc / of addressable photo thermal detector complete with mounting base complete as read through authorised dealer or oem ( compatible with est3 or equivalent addressable system ) make edward / apollo / siemens / notifier or equivalent 37 sitc of intelligent addressable programmable sounder complete as required through authorised dealer or oem ( compatible with est3 or equivlent addressable system ) make edward / apollo / siemens / notifier or equivalent 38 sitc of addressable fire control module complete as requiredthrough authorised dealer or oem ( compatible with est3 or equivlent addressable system ) make edward / apollo / siemens / notifier or equivqlent 39 providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinkler of rating 68 degree centigrade with required accessories ( pendant / upright sprinkler ) 40 sitc of horn cum strobe complete as read through authorised dealer or oem . ( compatible with est3 or equivalent addressable system ) make edward / apollo / siemens / notifier or equivalent 41 sitc of wall speaker 1.5 / 3 / 6 w metal box ceiling / wall speaker complete etc. as required make honeywell / bosch / ahuja or equivalent 42 dismantling , cleaning & re fixing intelligence detector , hooter , mcp & riincluding checking, testing and connection etc. as required. 43 supply installation testing commissioning of smps device compatible with two loop firepanel make est3 or equivalent as per direction of engg in charge . 44 servicing , commissioning and reprogramming of existed addressable fire alarm panelcompatible with est3 etc. complete as required. 45 sitc of protective cover locked with plastic tie / metallic wire suitable for addressable manual call pointincluding dismantling & re fixing mcp with necessary arrangements as per direction of engineer in charge make hensel kg9001 / honeywell or equivalent as approved by engg in charge . 46 sub head iii pipes & assecories supplying, fixing, testing & commissioning of double flanged sluice valve of rating pn 1.6 with non rising spindle, bronze / gun metal seat, isi marked complete with nuts, bolts, washers, gaskets and conforming to is 780 of following sizes as required :300mm 47 dismantling and reinstalling the existing 150 mm non return valve in horizontal alignment in the fbc pipeline, as well as providingadditional quantity of 150 mm c class heavy duty ms pipeconforming to is 3589 / is 1239, including welding, fittings such as elbows, flanges, nuts, bolts, gaskets, etc., whichever are required to complete the work, painting with two or more coats of synthetic enamel paint on the pipe of the required shade, testing and commissioning, etc., as required. 48 providing, installation, testing & commissioning of water curtain nozzle 15 / 20 mm dia nickel chrome plated brass, bspt, k factor as per design consideration complete as required 49 providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 3589 / is 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall / ceiling or on pipe with suitable clamp / support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia 50 supplying and fixing single headed external yard hydrant valve with 1 no. 63 mm diainstantaneous fm gunmetal / stainless steel coupling and cast iron wheel, isi marked, conforming to is 5290 ( type a ) with blank gunmetal / stainless steel cap and chain as required 51 single headed gunmetal 52 supplying, fixing, testing and commissioning of butterflyvalve of pn 1.6 rating with bronze / gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required : 53 80mm 54 100mm 55 150mm 56 structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 57 supplying & replacement of weather proof hose cabinet suitable for external hydrant / fbic fabricated out of 2 mm thick ms sheet with 6 mm thick glazed glass door in front having locking arrangement having provision for 02 nos rrl hose pipes & 01 nos nozzlemounted on wall or raise brick platform & duly painted with po redexternally & white internally with synthetic enamelled paint , sign writingetc. complete in all respect as required at site& having min dimension 900mm x 600mm x 500mm deep . 58 supplying and fixing 63 mm dia, 15 m long rrl hose pipe with 63 mm dia male and female couplings duly bound with gi wire, rivets etc. conforming to is 636 ( type a ) as required : gunmetal make newage / safex / safegaurd / essel / lifegaurd 59 providing & fixing of pressure switch in m.s. pipe line including connection etc. as required. make denfoss / indfos / sitzer 60 providing & fixing flow switch in following sizes m.s. pipe including connection etc. as required. 150 mm diamakedenfoss / indfos / sitzer 61 supplying and fixing undermentioned item in existingdrum & bracket arrangementcomplete connection etc. asrequired 62 water hose thermoplastic ( textile reinforced ) type 2 as per is: 12585size 20 mm nominal internal dia x 30 mtr length including credit for old scrap material which will be retained by the contractor etc., complete as required. 63 20 mm nominal internal dia gun metal globe valve with nozzle on existing water hose with ss clampincluding credit for existing gun metal globe valve & nozzle material which will be retained by the contractor etc., complete as required. 64 hose reel drum with brackets conforming to is 884 ms construction spray painted in post office red including credit for exisitng reel drumwhich will be retained by the contractor. etc. complete as required. 65 fabrication supply installation testing commissioning mscabinet made of 1.2mm thick ms sheet with4 mm thick transparent acrylic sheet double leaf door on the front including necessary locking arrangement including mounting on wall, suitable to accommodate different typefire extinguisher duly painted with post office red externally and white internally with synthetic enamel paint without back cover including dismantling & refixing the existing fire extinguisher completely required as per direction of engineer in charge ( min depth 250mm ) as per site condition for a fire extinguisher as required. 66 providing & fixing msclamp suitable for existing fire extinguisher ( dry powder 06 kg / water spray 09 ltr / co2 type 4.5 kg ) 67 sub head iv e &m workearthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. 68 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 69 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 70 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. 71 providing and fixing 25 mm x 5 mm copper strip in 40 mm dia g.i. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re filling etc. as required 72 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required 73 sitc of wall fan 400 mm sweep oscillating type having aerodynamically designed & balanced blade complete with all accessories such as front cover, mounting accessories i / c connection etc. as reqd.havells dzire 400 or equivalent in crompton / usha 74 wiring for submain wiring along with earth wire with following size of frls pvc insulated copper conductor single core cable in surface / recess medium class pvc conduit as reqd 75 2x1.5 sqmm + 1x1.5 sqmm earth wire 76 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5 / 6 a modular socket outlet and 5 / 6 a modular switch, connections etc. as required. 77 providing and fixing following switch gears, meters and accessoriesin existing cubicle panel / starter board including drilling holes in cubicle panel, making connections, etc. as required including credit for old scrap material which will be retained by the contractor etc., complete as required. 78 3pole, 415v , power contactor ac3 rating 18 a 79 3pole, 415v , power contactor ac3 rating 25a 80 3pole, 415v , power contactor ac3 rating 32a 81 3pole, 415v , power contactor ac3 rating 70a 82 3pole, 415v , power contactor ac3 rating 110 a 83 overload thermal relay mn2 l&t 9 15a 84 overload thermal relay mn2 l&t 14 23a 85 overload thermal relay mn5 l&t 66 110a 86 add on block 2no+2nc 87 add on block 1no+1nc 88 sub head v fire fightingequipmentssupply, installation, testing and commissioning of ul listed abc map 90% ( mono ammonium phosphate ) automatic ceiling mounted fire extinguisher for oil charged transformer rooms, capacity 10 kg, applicable fire classes a, b & c, ugts pressure gauge, brass forged sprinkler valves with nozzle and equipped with pressure gauge, external coating pure polyester and internal epoxy polyester powder coated, heat sensitive glass bulb of 68°c. make : firemech / ceasefire / minimax / kanex 89 providing and fixing dry powder ( stored pressure ) type portable fire extinguisher of following capacity with mono ammonium phosphate powder 90 % applicable to fire class a, b, c controllable discharge mechanism with epdm hose and nozzle, ugts pressure gauge, deep drawm with mig welding technology , external pure polyester & internal epoxy polyester powder coated , brass forged valves with safety pin of ss material and welding procedure approved by tpi rating as per 15683 and isi mark with suitable fixing bracket ( ms ) etc. as reqd .make ceasefire / minimax / kanex 90 6 kg powder stored pressure type 91 providing and fixing co2 type ( high pressure ) type portablefire extinguisher of following capacity with co2 gas foo fire class b & c electrical discharge controlmechanism fitted with high pressure steel braided discharge nozzle for dispersed discharge of co2 enamel spray painting powder coated handle , hot spinning seamless isi marked rating as per is 15683 with suitable fixing bracket ( ms ) etc. complete as reqd make ceasefire / minimax / kanex 92 4.5 kg co2 portable fire extinguisher type 93 sub headvi miscellaneous worksitcdiesel engine manual start ( air cooled ) driven make kirloskar taf1 / greeves / field marshal ( with std manual starting ) or equivalent flexiblly coupled with self priming pump kirloskar sp3l or equivalent in crompton / wilo , suction 80mm delivery 80mm mounted on movable trolley fabricated out of c channel complete with solid wheel with movable handle arrnagement & side open canopy of ms sheet. [ warranty 01 year ] 94 supplying, installation, testing & commissioning of 600 kva, 50 hz, servo motor operated line voltage corrector, copper wound, indoor, continuous duty, three phase, suitable for 3 phase unbalanced / balanced input voltage and unbalanced / balanced load conditions, which shall comprise three nos. fully ic controlled sensing circuits microprocessor based, with built in filters to improve the output wave to be pure sinusoidal and control each phase individually. conforming to is 9815:1994 with input voltage 300 460v output 415 ( as set output voltage ) , + 1%, naturally oil cooledwith first filling of transformer oiland necessary bypass arrangements, ms tank enclosure mounted on wheels, withdigital display having facilities to show fault indication, manual / auto indication, manual / auto selection switch, output voltage increase / decrease switch, input / output voltage indication, load current indication, including dismantling and credit for the existingkva stabilizer with transformer oil. the stabiliser should be guaranteed for 12 months from commissioning for any manufacturing defects. in the event of any failure within the above period, replacements or rectification of parts shall be free of cost. the quoted rate should include credit for existing600 kva stabilizer with transformer oil which will be retained by the contractor. ( make vinitec electronic laboratory / precision control instruments / selvon instruments pvt. ltd / automatic electric ( ae ) ) / purevolt ) 95 sitc oflead acid battery 150ah, 12v including the dismantling of existing battery, including credit for existing unserviceable battery of the same rating which will be retained by the contractor etc., complete as required. [ warranty 36month ] make exide xp1500 or equivalent in amaron & luminuous . 96 sitc of 7ah, 12 v, vrla maintenance free battery including the dismantling of existing battery, including credit for existing unserviceable battery of the same rating which will be retained by the contractor etc., complete as required. [ warranty 36month ] make exide12bv7b or equivalent in amaron & luminuous . 97 supplying & fixing pvc suction hose pipe isi marked size 75 / 80mm ( make texmo code a0695 or equivalent 98 providing & fixing cast ironfoot valve size 80 mm to end of pvc hose suction pipe etc. complete as required ( make kirloskar / sant / cri / kartar ) ...

Haryana Police Housing Corporation Limited - Haryana

32690701 supply, installation, testing and commissioning of cctvs with allied items including five year operation and maintenance in police stations and police posts at various locations in haryana state 1 supplying and drawing of 1 no utp 4 pair cat 6 lan cable in the existing surface / recess ms / pvc conduit as required ( hsr 23.23.9 ) 2 supply and erection of double door sheet steel enclosure distribution board suitable for mcbs and elcbs etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the engineer in charge of the work ( hsr 23.22.4. ) 3 23.22.4.1 spn db double door 4 way ( 2 incoming and 2 outgoing ) 4 supply and erection of miniature circuit breaker 240 / 415 v in the existing distribution board including making necessary connections: ( hsr 23.22.5. ) 5 23.22.5.1 ) 6 amp. to 32 amp single pole 6 23.22.5.3 ) 40 amp to 63 amp.double pole 7 earthing and lightening arrestor ( hsr24.1 ) 8 24.1.4. ) earthing with tinned copper earth plate 600mmx600mmx3mm thickincluding accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) etc. complete as required. 9 24.1.5 ) extra for charcoal or coke and salt for g. i. plate or copper plate earth electrode. 10 24.1.9 ) providing and fixing 25 mm x5 mm copper strip in 40 mm dia g.i. pipe from earth electrode as required. 11 24.1.10. ) providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material. 12 providing and fixing gi concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. ( hsr 23.8.10. ) 13 23.8.10.3 ) 4 modules 14 23.8.10.4 ) 6 modules 15 23.8.10.6 ) 12 modules 16 providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. ( hsr 23.8.11. ) 17 23.8.11.1. ) 5 amp 1 way switch 18 23.8.11.4. ) 5 amp socket 19 23.8.11.3. ) 15 amp 1 way switch 20 23.8.11.5. ) 15 amp 6 pin socket 21 23.8.11.10. ) blinking plate 22 23.8.11.11 ) rj 45 computer data socket outlet for cat 6 or cat6e cable modular type 23 wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire pvc insulated copper conductor cable 1100 volts grade in existing ms / pvc conduit etc as required. ( hsr 23.5.6. ) 24 23.5.6.1. ) 1 run of size 1.50sqmm ( 1 / 1.40mm ) 25 23.5.6.3. ) 1 run of size 4sqmm ( 1 / 2.24mm ) 26 sitc of indoor dome camera ( as per rfp vol iv technical spec. ) 27 sitc of outdoor bullet camera ( as per rfp vol iv technical spec. ) 28 server for police station with licensed antivirus, keyboard, mouse, monitor and other allied items ( as per rfp vol iv technical spec. ) 29 phq server with licensed antivirus, keyboard, mouse, monitor and other allied items ( as per rfp vol iv technical spec. ) 30 sitc of 32 / 40 channel nvr with sim for police post ( as per rfp vol iv technical spec. ) 31 sitc of 8 port poe+ switch ( as per rfp vol iv technical spec. ) 32 sitc of 16 port poe+ switch ( as per rfp vol iv technical spec. ) 33 16 port patch panel ( as per rfp vol iv technical spec. ) 34 sitc of 43 display ( as per rfp vol iv technical spec. ) 35 sitc of 65 display ( as per rfp vol iv technical spec. ) 36 supply and erection of hot dip galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, integral cable termination arrangement 5 mm thick bakelite base plate on suitable welded ms / gi bracket ( 32 a four way connector 2 no 10 a sp mcb ) if required, end cover and all accessories as supplied by the manufacture including providing rcc foundation of m25 grade ( 1 cement:1 stone aggregate: 2 coarse sand ) i / c excavation, steel reinforcement ( fe 500 ) @80 kg / cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of pcc 1 :5: 10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of engineer in charge5 metre long pole with top dia 65 mm and bottom dia 130mm with base plate of size 250 x 250 x 16 mm including pole mount bracket for cctv cameras. 37 supply and erection of 25mm heavy pvc conduit with accessories ( surface type ) 38 supply, installation testing and commissioning of sms pack of 3crore sms with sms gateway and all accessories for 5 years 39 supply, installation testing and commissioning of sd card reader 40 supply, installation testing and commissioning of 2tb hdd external usb ( passport ) 41 supply and laying of 3core x 4sq mm power cable ( in mtrs ) 42 supply installation testing commissioning of face plate ( single / dual ) 43 supply installation testing commissioning of utp cat mounting patch cords 3 ft length 44 sitc of smart integrated health monitoring software for dashboard on existing secured network to get alerts over email & sms ofhdd failure, camera equipment malfunction, tampering hdd or camera, connectivity failure, ups / power supplies status ) at district hq and state hq. 45 supply installation testing commissioning of 9 u rack including power distribution kit, cable manager 46 supply installation testing commissioning of24 u rack including power distribution kit, cable manager, etc 47 sitc of 5kva or more ups ( as per rfp vol iv technical spec. ) 48 sitc of battery bank for backup on 5kva ups or more on 12v smf batteries for 10 hours backup ( 12vx 20 no. of 120ah ) 49 sitc of vms license of camera make 50 sitc of 256 gb sd card class 10 51 s / e of workstation including monitor, keyboard, mouse with licensed antivirus and allied items complete in all respect. ( as per rfp vol iv technical spec. ) 52 sitc of 2 kva or more ups ( as per rfp vol iv technical spec. ) 53 sitc of battery bank for backup on 2kva or more ups 12v smf batteries for 10 hours backup ( 12v x 8 no. of 100ah ) 54 note: the bidder has to quote the capex and opex value in percentage of the total boq cost and upload the pdf for stating the capex and opex percentage value ( % ) ...

Public Works Department - Haryana

32596079 set up of vulnerable witness in judicial complex at karnal. ( providing electrical installation only ) . recall 23.1.6.1wiring main , sub mains and circuit wiring in twosingle core for phase and neutral wire and one single core for earth wire pvc insulated copper conductor cable 1100 volts grade in ms conduit etc as required.1 run of size 1.50 sqmm ( 1 / 1.40mm ) 2 23.1.6.21 run of size 2.50 sqmm ( 1.1.80mm ) 3 23.1.6.31 run of size 04 sqmm ( 1.1.80mm ) 4 23.5.1.3wiring only in 1.5 sqmm pvc insulated copper conductor cable for light / fan / call bell point in existing conduit pipe and ms boxes including cost of bakelite cover for ms box, switch, wall socket, ceiling rose / connector etc.group c 5 23.5.4.3wiring in existing conduit and ms box for 3 pin 5amp. plug point by using 2 no 1.5 sqmm frls copper wire and 1no 1.5 sqmm frls copper wire , including providing 1 no 5 / 6 amp 3 / 5 pin socket and 1 no 5 / 6 amp switch etc complete as requiredgroup c 6 23.5.5.3wiring in existing conduit system for 3 pin 15amp. plug point by using 2 no 4 sqmm frls copper wire and 1 no 4 sqmm frls copper wire for earthling , including providing 1 no 15 / 16 amp 3 / 6 pin socket and 1 no 15 / 16 amp switch etccomplete as requiredgroup c 7 23.6.6.1supply and erection of ms conduit pipe 1.6 mm thick , isi marked surface / recessed in slab / wall / ceiling etc. including cost of ms bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of engineer in charge of work. ms pipe of 20 mm dia. 8 supply and erection of pvc conduit isi marked ( medium ) recessed in wall / ceiling etc. including the cost of pvc bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of engineer in charge of work.23.7.6.2pvc pipe of 25 mm dia. 9 23.7.6.3pvc pipe of 32 mm dia. 10 23.7.6.4 pvc pipe of 40 mm dia. 11 23.8.1.1providing and fixing piano type accessories of approved make in existing box and bakelite sheet including fixing and making necessary connections, complete in all respect.switch 5 amp. on existing sheet. 12 23.8.1.2wall socket 5 amp on existing sheet. 13 23.8.1.315 amp. switch on existing sheet. 14 23.8.1.46 pin 15 multi socket on existing sheet 15 23.8.1.5ceiling rose flush / surface type 16 23.8.1.6 call bell 220 / 230 volts musical type 17 23.8.1.8 bell push with 4 metres 2 core, 0.50 sqmm ( 16 / 0.20 mm ) pvc flexible wire. 18 23.8.1.12 bakelite angle / straight button holder large size. 19 23.8.2 supply and fixing bakelite sheet on existing ms / gi / wooden / pvc box etc including fixing with brass screws and washers.5 mm thick 20 23.8.10 providing and fixing gi concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects.1 & 2 modules including combined plate for telephone and data 21 4 modules 22 6 modules 23 8 modules 24 12 modules 25 23.8.11 providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect.5 amp 1 way switch 26 15 amp 1 way switch 27 5 amp socket 28 15 amp 6 pin socket 29 bell push 30 step type fan regulator 2 modules 300 watt 31 23.9erection of exhaust fan in existing opening , complete with necessary earthling of fan including carriage from pwd store to the site of work. 32 23.11making suitable hole in the wall suitable for exhaust fan up to 450 mm sweep including finishing the same and fixing of stainless stell wire mesh 2 mm thick having about 50 meshes per inch at exhaust sidecomplete as required 33 23.12providing and fixing outdoor duty ply of 8 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required 34 23.13supply, erection and fixing of 8 mm thick ply wood board having a circular / rectangular hole etc as required including the cost of making hole, nuts and bolts, painting and other petty material with all labour etc. complete in all respect up to the entire satisfaction of engineer in charge of the work. 35 23.20fixing of led tube light / 2*2 ft square panel fitting directly on wall / ceiling or false ceiling including making connections etc as required. 36 23.22.1 supply and erection of modular case circuit breaker single pole / 4 pole on existing wall / pedestal / panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the engineer in charge of the work.4 pole mccb 6 amp to 100 amp 37 23.22.2 mccb enclosure made of sheet steel suitable for mounting mccb of following ratingsmccb up to 125 a fp 38 23.22.3supply and erection of sheet steel enclosures 1pole / 2 pole / 4 pole including providing sp / dp / tp / fp mcb on wall / on existing pedestal complete with necessary connections etc, : sp enclosure suitable for single pole mcb 39 23.22.4.5supply and erection of double door sheet steel enclosure distribution board suitable for mcbs and elcbs etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to to the entire satisfaction of the engineer in charge of the work.tpn dbhorizontal type double door 4 way ( 8 incoming and 3phase*4 outgoing ) 40 23.22.5.supply and erection of miniature circuit breaker / isolator 240 / 415 v in the existing distribution board including making necessary connections: 6 amp. to 32 amp single pole 41 23.22.5.36 amp. to 32 amp double pole 42 6 amp. to 32 amp mcbs four pole 43 40 amp to 63 amp. mcbs four pole 44 24.1.1earthing with gl earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. ( but without charcoalor coke and salt ) as required. 45 24.1.2extra for using salt and char coal / coke for pipe earth electrode as required. 46 24.1.6supplying and laying 25mm x 3mm g.i. strip at 0.5 metre below ground as strip earth electrode including solderingetc. as required. 47 24.1.14supply and erection of 20mm x 3 mm thick gi, tape fixed with suitable g.i. stapples of same size. 48 24.2.7.3supply and erection ofsuitable compression type brass cable glands for underground cable : 25 sqmm to 50 sqmm cable 2 to 4 core 49 24.2.8.5supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the engineer in charge of the work. 25 sqmm 50 ns items supply and erection of under ground aluminum armoured cablexlpe insulated loose in existing pipe or trenches complete with necessary connection. make rr / havells / polycab / grandlay / suraj.25 sqmm 4 core...

Indian Institute Of Management - Haryana

32142659 onsite providing and installation of electricals items for offices / classroom / hostels block at iim rohtak refrigerant piping: sitc of interconnecting following size of refrigerant copper pipe work, insulated with 13 mm thick closed cell electrometric nitrile rubber tubular insulation between each set of indoor & outdoor units properly fixed / supported with suitable size of clamp. make of copper pipe: maxflow / rajco / equivalent. makes of insulation : k flex / a flex / superlon / equivalent 15.6 mm o.d. ( soft copper; insulation : 13 mm ) 6.4 mm o.d. ( soft copper, insulation : 13 mm ) drain piping : supply, installation, testing and commissioning of rigid pvc piping on ceiling / vertical wall complete with fittings, supports as per specifications and duly insulated with 3 / 6 mm thickness of closed cell nitrile rubber. ( 25 mm dia ) control and transmssion wiring: supply, installation, testing and commissioning of annealedflexible tinned copper conductor shielded as per is:8130 1984 control cum communication cable of 4 core x 2.5sq mm communication on suitable refrigerant pipetray as per site requirements between outdoor &indoor unit complete. cu wire make; fusion / fhinolex / equivalent covering for copper pipe. 16a 3 pin power plug top floor stand for 2 tonne ac comprehensivemaintenanceof60no.ssplitac&10nostoweracfor02years ( 24months ) whichincludepreventivemaintenanceservices03no.s, cleaningofheatexchanger, filteretc, diagnoseofelectronicconnection, checkmotorperformance, unitperformance, currentetc.tocheckedpreandpostservice, breakdowncalls inspectionandresolution, replacementofcompressor, gascharging ( 2timesinayear ) , electricalparts, electronicparts, remotecontroller, repair / replacementofcoolingcoilandcondenser, replacementofplasticpartsasspecifiedbyengineerincharge, aftercompletionofdefectliability period as per tender documents / agreement. pvc batton 65*50mm for copper pipe wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit / batton with modular switch, modular plate, suitable gi / pvcbox and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. note make: anchor and as per govt approved make. group a wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. note make:polycab, havells, grandlay, l&t, rr cable, batra hanlay, bonton, bch and as per govt. approved make. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 4 x 10 sq. mm + 2 x 6 sq. mm earth wire supplying and fixing of following sizes of medium class pvc conduit / batton along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. note make: akg, bkg, bec, polypac and as per govt approved make. 25mm supply, installation, testing and commissioning of three star 2.0 tonne split ac with indoor and outdoor units as having following. make: ( hitachi / o general / diakin ) . power points & electrical fittings for faculty offices & ipl / ipm classrooms ) total amount section asupplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. note make: anchor and as per govt. approved make. supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.note make: anchor and as per govt. approved make. supplying and fixing suitable size gi / pvc box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 a modular socket outlet and 15 / 16 a modular switch, connections etc. as required note make: anchor and as per govt. approved make. supplying and fixing suitable size gi / pvc box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5 / 6 a modular socket outlet and 2 nos. 5 / 6 a modular switch, connections etc. as required. ( for light plugs to be used in non residential buildings ) note make: anchor and as per govt. approved make. supplying and fixing 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. note make: l&t, siemens and per govt. approved makes. single pole supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required note make: l&t, siemens and as per govt. approved makes. 100a supplying installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. note make usha, phillips, bajaj, crompton, wipro, havells and as per govt approved make supplying installation , testing, commissioning of wall bracket / ceiling fittings of all sizes and shapes containing upto two gls / cfl / led lamps per fitting, complete with all accessories including connections etc. as required. note make phillips , bajaj, ge, wipro , havells and as per govt approved make supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator note make: scheinder, legrand, l&t and as govt. approved make. 6 way ( 4 + 18 ) , double door 100 amp fpmccb incomer mdb panel note: make l&t, adlec, advance panel, abb, spc electrotech, tricolite and as per govt approved make laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. note make finolex, polycab, havells and as per govt approved make above 185 sq. mm and upto 400 sq. mm supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable 1.1 kv grade as required. 3½ x 240 sq. mm ( 62mm ) note comet, cosmos, baliga lightening and as per govt approved make supplying and installing following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspenders etc as required note make: slotco, steelways, equiptech and as per govt. approved make. 150 mm width x 50 mm depth x 1.6 mm thicknesssupplying and laying 25 mm x 5 mm g.i strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with g.i. nut, bolt, spring, washer etc. as required. ( jointing shall be done by overlapping and with 2 sets of g.i. nut bolt & spring washer spaced at 50mm ) earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. supplying of pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size 3½ x 240 sq. mm note make polycab, havells, finolex and as per govt approved make...

Haryana Board Corporation - Haryana

31981637 upgradation of 66 kv substation sadhaura to 220 kv level 1 a ) 100 mva 220 / 66 kv power transformer along with 10%extra t / f oil b ) nifpes for 100 mva t / f 2 a ) 100 mva, 220 / 33 kv power transformer along with 10%extra t / f oil with b ) nifpes for 100 mva t / f 3 25 / 31.5 mva, 66 / 11 kv power transformer 4 12.5 / 16 mva, 66 / 11 kv power transformer ( to be provided by hvpnl ) 5 220 kv sf 6 breaker along with 20% extra sf 6 gas 6 220 kv isolator with e / switch 7 220kv isolator without e / switch 8 220 kv surge arrestor 9 220 kv post insulator 10 220 kv cts for line & bus coupler ( 1200 800 400 / 1 1 1 1 1a ) 11 220 kv ct for transformer ( 450 300 / 0.577 1 1 1 1a ) 12 220 kv cvt 13 220kv c&r panelsline protection & circuit breaker control panel ( with auto reclose ) 14 transformer protection& ckt breaker control panel ( without auto reclose ) for both hv & lv side of 220 / 66kv t / f. ( 1 set for each t / f ) 15 transformer protection& ckt breaker control panel ( without auto reclose ) for both hv & lv side of 220 / 33kv t / f. 16 bus coupler cum bus bar protection & ckt breaker control panel without auto reclose ( double bus bar ) 17 220 kv nct ( 450 300 / 1a ) 18 220 kv pt 19 66 kv sf 6 breaker with 20% extra sf 6 gas 20 66 kv isolator with e / switch 21 66 kv isolator without e / switch 22 66 kv surge arrestor 23 66 kv ct for line ( 600 300 150 / 1 1 1a ) 24 66 kv ct for bus coupler ( 1500 1000 / 1 1a ) 25 66 kv ct for transformer i / c ( 1500 1000 / 0.577 1 1 1a ) 26 66 kv ct for 12.5 / 16 mva, 66 / 11kv transformer ( 300 200 150 / 0.577 1 1a ) 27 66 kv ct for 25 / 31.5 mva, 66 / 11kv transformer ( 300 200 150 / 0.577 1 1a ) 28 66kv pt 29 66kv nct for 220 / 66kv t / f ( 1500 1000 / 1a ) 30 66 kv nct for 25 / 31.5 mva, 66 / 11kv t / f ( 300 200 150 / 1a ) 31 66 kv nct for 12.5 / 16 mva, 66 / 11kv t / f ( 300 200 150 / 1a ) 32 66 kv cvt for line 33 66 kv c&r panelsline protection & circuit breaker control panel ( without auto reclose ) 34 transformer protection& ckt breaker control panel ( without auto reclose ) for lv side of 220 / 66 kv t / f. 35 transformer protection& ckt breaker control panel ( without auto reclose ) for 25 / 31.5 mva.66 / 11kv power t / f. 36 transformer protection& ckt breaker control panel ( without auto reclose ) for 12.5 / 16 mva.66 / 11kv power t / f. 37 bus coupler protection & ckt breaker control panel without auto reclose ( double bus bar ) 38 time synchronizationequipment 39 33 kv vcb 2000a for bus coupler & incomer 40 33 kv vcb 630a 41 33 kv capacitor vcb 630a 42 33 kv la’s 43 33 kv isolator 630a 44 33 kv isolator 2000a forbus coupler &incomer 45 33 kv l&e switch for lines & cap. bank 630 amp 46 33 kv bus pt 47 33 kv line cum capacitor ct 400 300 / 5 1a 48 33 kv i / c transformer ct 2000 1000 / 0.577 5 5 1a 49 33 kv bus coupler ct 2000 1000 / 5a 50 33 kv nct ( 2000 1000 / 5a ) 51 33kv c&r panels33kv line protection & circuit breaker control panel ( without auto reclose ) 52 33kv t / f incomer c&r panel without autoreclose alongwith 1 no. sem 53 33 kv ckt. breaker control panel without auto reclose and capacitor protection panel 54 33kv bus coupler protection & ckt breaker control panel without auto reclose ( double bus bar ) 55 11 kv nct for 25 / 31.5 mva, 66 / 11kv t / f ( 1800 900 / 5a ) 56 11 kv nct for 12.5 / 16 mva, 66 / 11kv t / f ( 1800 900 / 5a ) 57 11 kv la 58 11 kv 13 panel board ( 1250a ) with one sem on each t / f i / c panel. 59 11 kv 15 panel board ( 2000a ) with one sem on each t / f i / c panel. 60 1x21.744mvar33 kv capacitor bank along with str. & allied equipment ( nct, series reactor etc., ) as per specification. 61 3.4mvar 11kv automatically switched capacitor bank along with allied equipment for 12.5 / 16 mva, 66 / 11kv transformer 62 6.804 mvar 11kv automatically switched capacitor bank along with allied equipment for each 25 / 31.5 mva, 66 / 11kv transformer 63 220v 200 ah battery 64 220 v battery charger 65 220 v d.c.d.b. suitable for 200ah battery 66 415 v lt ac mccb board 500 a 67 11 / 0.4 kv station transformer 200 kva with csp. 68 100 kva dg set along with associated accessories 69 1.1 kv copper control cable armoured for 220 kv bays of size2cx6mm2, 7cx4mm2, 4cx4mm2, 2cx4mm2, 16cx2.5mm2, 10cx2.5mm2, 7cx2.5mm2, 3cx2.5mm2 including junction box ( as per section 5 of copper control cables specifications and section 7, switchyard erection ) . 70 1.1 kv copper control cable unarmoured for 66 kv bays of size 2cx6mm2, 7cx4mm2, 4cx4mm2, 2cx4mm2, 16cx2.5mm2, 10cx2.5mm2, 7cx2.5mm2, 3cx2.5mm2 including junction box ( as per section 5 of copper control cables specifications and section 7, switchyard erection ) . 71 1.1 kv copper control cable unarmoured for 33 kvbays of size 2cx6mm2, 7cx4mm2, 4cx4mm2, 2cx4mm2, 16cx2.5mm2, 10cx2.5mm2, 7cx2.5mm2, 3cx2.5mm2 including junction box ( as per section 5 of copper control cables specifications and section 7, switchyard erection ) . 72 650 / 1100 volts 3.5 core 240 mm2 aluminum power cable from aux. transformer to acdb 73 650 / 1100 volt 3.5 core 70 mm2 aluminum cable for oil filtration set. 74 650 / 1100 volt 4 core 16 mm2 armoured copper power cable for mldb and other cable required as per contract for 220kv bays. 75 650 / 1100 volt 4 core 16 mm2 unarmoured copper power cable for mldb and other cable required as per contract for 66kv bays. 76 650 / 1100 volt 4 core 16 mm2 unarmoured copper power cable for mldb and other cable required as per contract for 33kv bays. 77 11kv 1cx1000 mm2aluminum cable for t / f to 11kv incomer with termination kit for both ends ( 2 runs per phase for each transformerallocating them 1 runs per phase for each 11kv i / c ) for 12.5 / 16 mva t / f and 4 runs per phase for each transformerallocating them 2 runs per phase for each 11kv i / c for 25 / 31.5 mva t / f 78 11 kv power cable xlpe ( aluminum ) 3c x 400sq mm for capacitor bank with termination kit for both ends for cap. bank ( 6.804 mvar ) 79 11 kv power cable xlpe ( aluminum ) 3c x 185 sq mm for capacitor bank with termination kit for both ends for cap. bank ( 3.4mvar ) 80 11 kv power cable xlpe ( aluminum ) 3c x 50 sq mm for station t / f with termination kit for both ends. ( for each stn t / f ) 81 earthing mat material and connectivity of earth mat with existing earth mat. the earth mat will be designed / quoted for soil resistivity of 50o. in case soil resistivity is more than 50o then the earth mat will be designed for actual soil resistivity. the payment of extra material to be used for earth mat shall be made on pro rata basis. the approximate area of earth mat to be laid is given in the corresponding columns of the substations. however, item will remain a lot item. ( aprox. 26400 sq mtr ) 82 fire fighting equipments as per section 6 22.5 kg capacity fe co2 type, trolley mounted 83 25 kg capacity fe dcp type, trolley mounted 84 dcp 9 kg capacity, wall mounted 85 fe co2 6.5 kg capacity, wall mounted 86 dcp 6 kg capacity, wall mounted 87 foam type 9 litre capacity, wall mounted 88 water co2 9 litre, wall mounted 89 fire buckets ( 12 no.s with stand in one set ) 90 supply and installation of 2 fittings of 240w led lamps with all accessories for complete lighting of outdoor switch yard area including all accessories, cables etc. as per clause 16.0 of section 7 of the specifications. 91 complete lighting of road and street by providing 90w led lamps on tubular steel poles at a distance of 15meter along the roads and streets including all accessories, cables etc. as per clause 16.0 of section 7 of the specification 92 ( a ) supply and installation of 35w led tube fitting on tubular steel poles along fencing / boundary wall at a distance of 30 meter including all accessories, cables etc. as per clause 16.0 of section 7 of the specification. 93 ( b ) supply and installation of post top lantern 40w led lamps with all complete accessories at the entrance gate of sub station. 94 ( c ) supply and installation of 40w led lamps with all complete accessories on corners of control room building. 95 high wall type split ac unit of 2 ton capacity for computer room ( as per technical specification ) 96 testing of ium system at nabl accredited lab 97 complete substation automation system for 220 / 66 / 33 kv substations including hardware ( along with transducers ) & software for present bays and software for future bay along with associated equipment for the bays as defined in the technical specification, section sub station automation system ) as per technical specification. the scope for present and future is as under: 220kv bayspresent bays future baysline bays62transformer bays3 bus coupler bay 1 66kv bays line bays 85transformer bays 3166 / 11kv66kv t / f i / c bay2 bus coupler bay1 33kv bays line bays 42transformer i / c bays11bus coupler bay 1 capacitor bay1 98 computer system ( sff ) with intel core i5, 9th generation processor, 8gb ram, 1 tb hdd, 19.5 display with ups. 99 mono chrome multi functional printer, a 4, 25 ppm, wi fi 100 bolted type 220 kv single tension string assembly with silicone rubber polymer composite insulators ( e&m strength 9000 kg ) with all hardware accessories including ball & socket connection and tension clamp set suitable for twin tarantula ( string ) . 101 bolted type 220 kv single suspension string assembly with silicone rubber polymer composite insulators ( e&m strength 9000 kg ) with all hardware accessories including ball & socket connection suitable for twin tarantula ( string ) . 102 bolted type 220 kv single tension string assembly with silicone rubber polymer composite insulators ( e&m strength 9000 kg ) with all hardware accessories including ball & socket connections and tension clamp sets suitable for single tarantula ( string ) . 103 bolted type 220 single suspension string assembly with silicone rubber polymer composite insulators ( e&m strength 9000 kg ) with all hardware accessories including ball & socket connections and suspension clamp sets suitable for single tarantula conductor. 104 bolted type 66 kv single tension string assembly with silicone rubber polymer composite insulators ( e&m strength 9000 kg ) with all hardware accessories including ball & socket connection and tension clamp set suitable for twin tarantula ( string ) . 105 bolted type 66kv single suspension string assembly with silicone rubber polymer composite insulators ( e&m strength 9000 kg ) per string with all hardware accessories including ball & socket connection suitable for twin tarantula ( string ) . 106 bolted type 66 kv single tension string assembly with silicone rubber polymer composite insulators ( e&m strength 9000 kg ) with all hardware accessories including ball & socket connections and tension clamp sets suitable for single zebra ( string ) . 107 bolted type 66 single suspension string assembly with silicone rubber polymer composite insulators ( e&m strength 9000 kg ) with all hardware accessories including ball & socket connections and suspension clamp sets suitable for single zebra conductor ( string ) . 108 bolted type 33 kv single tension string assembly with silicone rubber polymer composite insulators ( e&m strength 9000 kg ) with all hardware accessories including ball & socket connection and tension clamp set suitable for twin tarantula ( string ) . 109 bolted type 33 kv single suspension string assembly with silicone rubber polymer composite insulators ( e&m strength 9000 kg ) with all hardware accessories including ball & socket connection suitable for twin tarantula ( string ) . 110 bolted type 33 kv single tension string assembly with silicone rubber polymer composite insulators ( e&m strength 9000 kg ) with all hardware accessories including ball & socket connections and tension clamp sets suitable for single tarantula ( string ) . 111 bolted type 33 kv single suspension string assembly with silicone rubber polymer composite insulators ( e&m strength 9000 kg ) with all hardware accessories including ball & socket connection suitable for single tarantula ( string ) . 112 bolted type 11 kv single tension string assembly with silicone rubber polymer composite insulators ( e&m strength 9000 kg ) with all hardware accessories including ball & socket connections and tension clamp sets suitable for twin tarantula ( string ) . 113 boltless c type wedge connectors matching with conductor size. 114 copper lugs glands, pvc ferrules for control cabling. 115 fiber cleats, aluminium clamps, bolts, nuts, washers etc for fixing control cables in trenches 116 galvanised iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 150x25x2 mm, 100x25x2 mm and 75x25x2 mm and g.i conduits of 50 / 100mm diameter from equipment to main trench as per section 7 for switchyard erection. 117 2.5” dia hdd / pvc pipe for 4cx4mm2 control cable from ct, vt to metering system as per section 5, chapter 5. 118 aac tarantula conductor 119 acsr zebra conductor for 66kv line bays and t / f bays only 66kv side 120 7 / 3.15 gs earth wire 121 spacers for twin tarantula / zebra conductor 122 u bolt 20mm dia 123 lattice type steel structure for 220 kv substations sadhura supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 220 / 66 / 33 kv switchyard fabricated from steel conforming to is: 2062 including nuts bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner.main substation tower and beamtower type at 1 124 tower type at 3 125 tower type at 4 126 tower type at 6 127 beam type ab 1 128 beam type ab 2 129 beam type cb 6 130 beam type cb 7 131 tower type ct 4 132 tower type ct 5 133 tower type ct 6 134 tower type ct 8 135 beam type dd 1* 136 beam type dd 2* 137 beam type dt 3 138 beam type db 2x 139 tower type dt 2 140 220 kv ct drawing no. htd / st 147 141 220 kv nct drawing no. htd / st 150 142 220 kv pt / cvt drawing no. htd / st 147 143 220 kv surge arrestor drawing no.htd / st – 93r 144 220 kv bus post insulator drawing no. htd / st 116 145 220 kv isolator / l&e drawing no. htd / st 170 146 66 kv ct / cvt drawing no. htd / st 88r 147 66 kv nct drawing no. htd / st 145 148 66kv bus pt drawing. no. hhw / st 66 149 66 kv surge arrestor drawing no. hw / st 89 150 66 kv isolator / l&e drawing no. htd / st 87 151 33 kv la drawing no. htd / st 89r 152 33 kv ct drawing htd / st 88 153 33 kv isolator / l&ehtd / st 110 154 33 kv nct drawing htd / st 88 155 33 kv pt drawing htd / st 88 156 11kv nct drawing no. htd / st 149 ( for 66 / 11kvt / f ) ( if required ) 157 plc terminals ( no. ) 158 plc terminal with prot.coupler ( no. ) 159 wave trap 1250a 160 ltu ( p / p ) ( set. ) 161 48v battery 300ah& battery charger 300ah ( 1 each ) 162 hf cable ( kms ) 163 earth work in filling1.1 earth filling with good earth ( as per satisfaction of executive engineer / civil works division ) , laying in layers ( as per specification ) , dressing, including carriage, irrespective of lead, loading, unloading, watering and compaction in layers with roller including compensation of earth complete in all respect. 164 foundationssupply of labour, t&p, material and construction of rcc footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & drawings attached with the tender document including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc.and other items not mentioned herein but required for the completion of work.a. gantry towers i ) at 1 165 ii ) at 3 166 iii ) at 4 167 iv ) at 6 168 v ) ct 4 169 vi ) ct 5 170 vii ) ct 6 171 viii ) ct 8 172 ix ) dt 2 173 x ) dt 3 174 b. equipment 220kv sidei ) 220kv la 175 ii ) 220kv isolator / l&e switch 176 iii ) 220kv cvt 177 iv ) 220kv pt 178 v ) 220kv ct 179 vi ) 220kv post insulator 180 vii ) 220kv nct 181 66kv sidei ) 66kv la 182 ii ) 66kv ct 183 iii ) 66kv cvt 184 iv ) 66kv pt 185 v ) 66kv l&e / isolator 186 vi ) 66kv nct 187 33 kv sidei ) 33kv la 188 ii ) 33kv isolator / l&e switch 189 iii ) 33 kv nct 190 iv ) 33 kv ct 191 v ) 33 kv pt 192 3. breaker foundationdesign, engineering, supply of labour, material and construction of breaker foundations including all associated works, rcc, pcc, reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications. i ) 220kv sf 6 breaker 193 ii ) 66kv sf 6 breaker 194 iii ) 33kv vcb 195 4. roadssupply of labour, material and construction of cement concrete roads and walkways / shoulders from nh / sh / etc. to switch yard / switch house building as per gelo / clo as per sectional detail drawing no. hcd / sk 181 r1 and technical specification.i. 6.0m near main road 196 ii.5.0m wide road within substation land 197 iii. 3.66m wide road within substation land 198 5. capacitor bank foundationsdesign, engg. & supply of labour, material & construction of foundations for following rating capacitor bank with capacitor unit ( with allied equipments ) & series reactor etc. including chain link fencing 1.8m height around cap. bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification.i. 1x21.744 mvar 33 kv capacitor bank 199 ii. 1x3.4 mvar 11 kv capacitor bank 200 iii. 1x6.804 mvar 11 kv capacitor bank 201 6. road culvertdesign, engineering and const. of pipe culvert ( s ) at suitable locations under the approach road ( from main pwd / huda / municipal / village road to the sub station entry point ) including, cost of labour, material complete in all respects as per i.r.c. standards. 202 7. transformer foundation7.1 design, engg., supply of labour, material and construction of t / f foundation including radiator foundations etc. complete transformer foundations including all associated works, rcc, pcc, reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications and hvpnl drawing. in case additional foundation is / are required as per approved equipment drawing, the same shall be constructed by the successful bidder without any extra cost to hvpnl. such drawing ( s ) shall, however, be got approved from hvpnl.i ) 100mva, 220 / 66 kv t / f foundation 203 ii ) 100mva, 220 / 33kv t / f foundation 204 7.2 construction of transformer foundation including all associated works, rcc, pcc, reinforcement steel, misc. structural steel and other items not mentioned herein but required for completion of work as per technical specifications & drawing attached. in case extra foundation ( s ) has / have to be constructed ( as per approved t / f drawing ) to complete the job, nothing extra would be paid on this account.iii ) 25 / 31.5 mva, 66 / 11 kv t / f foundation 205 iv ) 12.5 / 16 mva, 66 / 11 kv t / f foundation 206 7.3 design, engg., supply of labour, t&p and material including rcc, pcc, reinforcement steel, misc. structural steel & other item ( s ) not mentioned herein but required for the completion of work as per tech. specs. for construction of below mentioned t / f foundations. i ) 200kva 11 / 0.4kv station t / f 207 ii ) 100kva dg set 208 8. outdoor cable trenchessupply of labour, material such as cement, reinforcement steel, gi angles, flats, pcc & brick pillars below cable trenches for construction of out door cable trenches ( odct ) of required depth / type with pre cast rcc covers including associated works like cable trench culverts crossings for roads and sumpit cum pump chamber with 2hp motor of reputed make, starter, volt meter, amp meter etc. as per approved trench layout plan, hvpnl drgs. & tech. specs. complete in all respect. 209 9. site surfacing9.1 providing, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed / crushed / broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of xen / civil works division. 210 9.2 providing, supplying & laying 100mm thick pcc ( 1:4:8 ) using 20mm nominal coarse aggregates and supplying & spreading 100mm thick layer of 40mm nominal size uncrushed / crushed / broken stone pebbles over the pcc including construction of toe wall ( exposed wall plastered with cement mortar 1:5 ) to hold 40mm single size uncrushed / crushed / broken stone pebbles wherever required in the bays covered under the present scope as detailed in the gelo & instructions of concerned xen / civil works division. 211 10. boundary wall10.1 supply of labour, t&p, material & construction of front, side & u / c boundary walls ( brickwork below dpc level ) as per gelo / clo, tech. spec. & hvpnl drgs including excavation, pcc, back filling etc. complete in all respects. 212 10.2 supply of labour, material and construction of front, c & u / c boundary walls above dpc including main gate foundationsas per gelo / clo, technical specifications. & hvpnl drg. hcd / ts 1176 r3 including dpc complete in all respect.i. 6 ft. high u / c b / wall with barbed wire on angles at top including construction of entrance gate ( w / o wicket gate ) for yard. 213 ii. 4½ ft. high front wall including providing grill at top of wall & construction of main entrance gate ( with wicket gate ) . 214 11. control roomsupply of labour, material & construction of control room building complete in all respect as per tech. specs. & approved drgs. attached including exterior & interior acrylic emulsion paint, all internal services like water supply including supply & providing of 5000ltr. capacity triple layered sintex / diplast pvc tank, sewerage system, staircase, electrification including wiring, modular switches, maximum 20w 4ft. long led tubes with fittings minimum 1960 lumens, ceiling / exhaust fans , finishing, plinth protection, indoor trenches, trench covers, soakage pit near the switch house building, connection of sewerage system to soakage pit / sewerage system of local authorities ( as applicable ) , connection to main water supply system of local authority / submersible bore ( as applicable ) etc. & any other item not mentioned herein but required for completion of works. the successful bidder shall also provide water supply connection from bore well / huda / municipal / public health or panchyat water supply scheme ( as per available source of portable water ) to the control room bldgs. without any extra cost of hvpnl. 215 12. u / c fencing & gates providing & fixing chain link fencing including foundations, gi angle iron posts and gate ( s ) complete as per electrical layout & tech. spec. & as per drawing attached. 216 13. pcc pavementconstruction of pcc pavement in front, rear or side ( as per site requirement of the switch house building ) as per drawing no. hcd / sk 172 & technical specifications. 217 14. drainage cum rain harvesting system14.1 supply of labour, material for construction of recharge structures with bore well ( s ) as per hvpn drawings & specs. complete in all respect. the location of recharge structures shall preferably be located on corner ( s ) of the substation and shall be got decided from the concerned xen / civil works division on the basis of surroundings of the substation ( s ) . in case ground water table is less than 8m from fgl, rain harvesting well shall not be constructed ( the drainage system with sump pit is to be constructed as per item mentioned below ) . 218 the successful bidder shall evolve design & drawing for drains, manholes with rcc covers andsettlement tankincluding preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard ( s / stn. ) area into respective bore well ( s ) in such a way that there shall be no ponding of water on the roof and switch yard ( s / stn. ) . the layout so developed shall be got approved from the employer. the location of sump pit cum pump chamber shall preferably be locatedon corner ( s ) of the s / stn. and shall be got decided from the concerned xen / civil works division on the basis of surroundings of the substation ( s ) . the successful bidder will also supply labour and material for construction of sump pit cum pump chamber as per hvpnl drgs. & provide two no. non clog pump ( s ) of 5hp of reputed make capacity with main switch, starter, volt meter, amp. mtr. etc. ( for each sump pit ) for disposal of excess water to outfall point. any other item ( s ) not mentioned herein but is / are required for completion of works shall be done by the successful bidder without any extra cost to the employer. 219 15. ac kiosk ( rcc framed structure ) design, engineering ( architectural and structural drawings of ac kiosk room ) , supply of labour, material and construction of ac kiosk room on rcc framed structure including anti termite treatment, plinth protection, electrification ( ceiling led tubes with fitting, modular switches, boxes, ac, electric wire etc. ) , acrylic emulsion and weather proof ( exterior acrylic paint ) , aluminum work ( doors / windows / ventilators frames etc ) , false ceiling, floor finishing, indoor rcc cable trenches, double brick wall with 50mm thick glass / mineral wool insulation complete in all respect as per technical specification. items, which are not mentioned but required for completion of work shall be provided by the successful bidder without any extra cost.i. 220 kv ac kiosk 220 ii. 66 kv ac kiosk 221 iii. 33 kv ac kiosk 222 16. rcc m 20 inclusive of labour, material, shuttering, steel reinforcement etc. complete in all respects to compensate excess quantity required to be executed due to difference in existing natural ground level and the formation level to be fixed after contouring or difference on account of revised drawing issued at the time of construction and the tender drawing. 223 17. barbed wire with rcc postsupply of labour and material for providing barbed wire with rcc post including gate etc. complete in all respect as per clo, technical specification and attached drawings. 224 18. rcc antifire wallconstruction of rcc anti fire wall of suitable height between t / f as per hvpnl drawing and all associated works including supply of labour, material, cement, reinforcement steel, steel form work etc. as per technical specification.i ) . anti firewall for 100 mva t / f plinth 225 ii ) anti firewall for 25 / 12.5 mva t / f plinth 226 19. dismantlementdismantling of existing u / c fencing, overhead tank, sump pit, old quarters & control room buildingat66 kv s / stn., complete in all respect. removal and disposal of malba / debris whatsoever received after dismantlement is in the scope of successful bidder and is to be disposed of as per satisfaction of engineer incharge. the material whatsoever shall be the property of the successful bidder. the dismantled material shall not be allowed for reuse at any of the sub stations....

Dakshin Haryana Bijli Vitran Nigam Limited - Haryana

31693919 supply, installation, testing & commissioning on partially turnkey basis for execution of work of replacement of lt un armoured/ab cables and additional work on 2 no. urban feeders and 4 no. rds feeders under (op) divn palwal (op circle, palwal) under the jurisdiction of dhbvn. 1 pcc pole 11 mtr. 2 pcc pole 9 mtr. 3 stay sets 8 long complete with x plat 460mm of angle 65x65x6 elbow & rod wt. 13.80 kg. 4 stay wire 7/8 swg 5 gsl 8 swg 6 m.s nuts bolts off sizes 7 11 kv disc insulator with fitting 8 11 kv disc insulator without fitting for stay 9 11 kv pin insulator with pin 10 lt insulator 11 v shape x arm 100x50x6 mm wt. 12.135 kg. 12 v shape x arm 75x40x6 mm wt. 8.4 kg. 13 m.s. channel (x arm) 100x50x6mm 2200mm (for h pole) wt. 17.38 kg. 14 ms channel 75x40x6mm (2200mm) for fuse unit. wt. 12.54 kg. 15 ms channel of various size 16 m.s. angle 50x50x6mm 3220mm (bracing 4 pole) wt. 14.49 kg. 17 m.s. angle 50x50x6mm 2860mm (bracing h. pole) wt. 12.87 kg. 18 m.s.angle iron 50x50x6mm 2400mm (for earth wire) wt.10.80 kg. 19 m.s angle 50x50x6mm 2200mm (belting for h pole) wt. 9.90 kg. 20 m.s. angle 50x50x6mm 2040mm (belting 4 pole) wt. 9.180 kg. 21 ms flat for t off bracing (900mm) 50x6mm wt. 2.160 kg. 22 ms flat 50x6mm 23 channel 75x40x6mm (galanized) for earth wire for h pole 24 angle 50x50x6mm 25 p.g. clamps for 30/50/80/100 mm2. 26 half clamps wt. 1.47 kg. hvpn drg. no. 2380 27 full clamps wt.2.325 kg. hvpn drg. no. 2349 28 11 kv top brackets / hamper wt. 1.480 kg. 29 acsr conductor 50mm2 ( rabbit) 30 acsr conductor 80mm2 ( raccoon) 31 11 kv 400 amps. go switch complete with handle, pipe & supporting channel. 32 lightening arrestor 9 kv 33 lightening arrestor 11 kv (set of 3 pcs) rs. 2420/ each 34 earthing set with complete material i.e. gi pipe, strips, earthing rod, coal & salt etc. 35 earthing rodwt. 6.175 kg. 36 eye screw bolts 9”x5/8 wt. 0.483 kg. 37 alluminium thimble off size 38 barbed wire 39 number plate 40 d straps 41 danger plate 42 ms x plate 43 suspension clamp 44 11 kv vcb 18.4 ka, 350 mva rapturing capacity, 24 volt dc operated indoor type rating 400 amps. for outgoing panel 45 11 kv vcb complete panel 220 v dc 46 11 kv cable box 35+70 mm2 o/d 47 11kv xlpe cable 3c 185mm2 48 11kv xlpe cable 3c 185mm2+150 mm2 49 3/cx185 mm sq.o/d heat shrinkable cable box 50 3/cx185 mm sq.i/d heat shrinkable cable box 51 c.i. pipe 250 mm dia 14 mm thickfor railway crossing 52 11 kv xlpe cable 3 core 300 mm2 for railway crossing 53 drilling for railway crossing 54 eye hook...