40431168
special repair to bldg. no. 200 ( block of 6 qtrs ) in cw lines andprovision ofsteel utensil rack in 118 x jcos / or govt md accnin cw lines & albert ekka line and provision of 50 xexhaust fans for jcos md accn in cw lines in the area ofage b / r i under ge ( n ) ambala cantt ; 1 schedule a part i ( b / r items ) taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by the engineer in charge. 2 demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the engr in charge. 3 m&lbrick work with sub class b old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the engineer in charge. 4 m&lbrick work with sub class b old size bricks straight or curved on plan to anyradius in half brick thick wall built in cement mortar 1:4 complete all as specified and as directed by the engineer in charge. 5 m & l rendering 15 mm thick on brick work or concrete wall surfaces in cement mortar 1:4including mixing water proofing compound @ 2% by weight of cement or as per manufacturers instruction and finished fair and even without using extra cement complete all as specified and as directed by the engineer in charge. ( wpc shall be measured and paid for separately ) 6 material and labour rendering 10 mm thick on any faces of brick work or concrete wall surfaces in cement mortar 1:6 andfinishedeven and fair without using extra cement complete all as specified and as directed by the engineer in charge. 7 supply only water proofing compound complete all as specified and as directed by the engineer in charge. 8 material and labour rendering 05 mm thick on fairfaces of brick work or concrete ceilingsurfaces in cement mortar 1:3 andfinishedeven and smooth without using extra cement complete all as specified and as directed by the engineer in charge. 9 m&l preparation of newly plastered / unplastered surfaces of walls and applying two coats of oil bound distemperwith painting roller over a coat of alkali resistant primer over and inlcuding 1mm to 2mm thick wall care putty white cement based in two or more coats to achive smooth surfacecomplete all as specified and as directed by the engineer in charge. 10 m & l complete removal of existing treatment on walls ( any number of layers ) by scrapping with steel scrappers or any other means, washing down with water to remove loose particles etc and applying two coats of oil bound distemperwith painting roller over a coat of alkali resistant primer over and including 1mm to 2mm thick wall care putty white cement based in two or more coats to achieve smooth surfacecomplete all as specified and as directed by the engineer in charge. 11 m&l preparation of new plastered / unplastered surfaces of brick / concrete ceiling and applying three coats of white lime wash complete all as specified and as directed by the engineer in charge. 12 m&l preparation of old decorated brick / concrete, plastered / un plastered surfaces ofceiling and applying two coats of white lime wash complete all as specified and as directed by the engineer in charge. 13 m&lpreparation of newly plastered surfaces of wall and applying two coats of cement based paint complete all as specified and as directed by the engineer in charge. 14 m & l complete removal of existing treatment on walls ( any number of layers ) by scrapping with steel scrappers or any other means, washing down with water to remove loose particles etc and applying two coats of cement base paint complete all as specified and as directed by the engineer in charge. 15 m & l complete removal of existing treatment on walls ( any number of layers ) by scrapping with steel scrappers or any other means, washing down with water to remove loose particles etc and applying two coats of 100% premium acrylic emulsion paint having voc less than 50 gm / litre and uv resistance as per is 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade ( company depot tinted ) with silicon additives @ 1.43 litre / 10 sqmover and including priming coat of exterior primer applied @ 0.90 litre per 10 sqmcomplete all as specified and as directed by the engineer in charge. 16 dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ) , removing servicable tiles to store and rubbish off the premises complete all as specified and as directed by the engineer in charge. 17 m & l25 mm thick pcc 1:2:4, type b0 as in sub base of floor ( using 12.50mm gradedcrushed stone aggregate ) , finished even & fair without using extra cement complete all as specified and as directed by the engr in charge. 18 m&lnon skid coloured ceramic tiles joint freepremium / 1st quality 7 to 8 mm thick, ( square / rectangular ) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over andinculding15mm thick screed bed in cm 1:6 complete all as specified and as directed by the engineer in charge. 19 m&lnon skid coloured ceramic tiles joint free premium / 1st quality of same description as of floor tiles in serial item no18 abovebut 100mm to 200mm heightas in skirting, set and jointed in neat cement slurry and pointed in white or colouredcement mixed with pigmentto match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4complete all as specified and as directed by the engineer in charge. 20 material and labour glazed ceramic coloured tiles joint free 1st quality in vertical surfaces / skirtings / dados of size 450x300x7mm thick / 300 x 600 x 7 mm thickor nearest size as required , set and jointed in neat cement slurry and pointed in white or colouredcement mixed with pigmentto match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4complete all as specified and as directed by the engineer in charge. 21 m&lnon skid coloured ceramic tiles joint freepremium / 1st quality 7 to 8 mm thick, ( square / rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over andincluding15mm thick screed bed in cm 1:6 complete all as specified and as directed by the engineer in charge. 22 material and labour for marble work, baroda green, 16 18mm thick, in one piece in width and length not less than 1.8 m ( except in case of slab is more than 1.80 meter and less than 2.40 meter smaller size as approved by engr in charge may be used ) table rubbed & polished in shelves, coocking plateform, tread of stair case, window cill and similar locationetc including 15mm thick bedding layer in cement mortar ( 1:4 ) including pointing in white cement ( 1:2 ) using marble dust with admixture of pigment to match with marble including rounding of exposed edges and finally granite finish polishing complete all as specified and as directed by the engineer in charge. 23 m & l formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, chajjas including edges etc., work in rough finished flat surfaces of concrete complete all as specified and as directed by the engineer in charge. 24 demolition of reinforced cement concrete in roofs, floors, beams, chajjas, staircases, landings and similar suspended work ( reinforcement cut as required to facilitate demolition ) complete all as specified and as directed by the engineer in charge. 25 m & l reinforced cement concrete 1:1 1 / 2:3 ( nominal mix ) using 20mm graded crushed stone aggregates as inchajjas, beams, lintels over 1.5 mtr spanand the like complete all as specified and as directed by the engineer in charge. 26 m & lprovidingpcc precast 1:2:4 type b1 using 20mm gradedcrushed stone aggregate as in landings, precast cover slabs ( for manholes etc. ) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including chamfers, weathering, throating etc and setting in cement mortar1:4 complete with joints to match, complete all as specified and as directed by the engineer in charge. 27 m & lmild steel framed work such as grills, gratings, etc. with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, walk ways, railingsconforming to fe.290.gde e 165 complete all as specified and as directed by the engineer in charge. 28 m electric meter, kept in safe cloudy of contractor s storetillcompletion of civil works and after completion of civil works cleaning the electric meter and refixingon the same location, making electrical connection, testing complete all as specified and as directed by the engr in charge. 122 disconnecting water supplyconnection, taking down electric geyser of any make, kept in safe cousdy of contractor s storetillcompletion of civil works and after completion of civil works cleaning the geyser body, filling the cavity, rubbing with sand paper, taking off old paint with the help of chemicals & painting the electric geyser with one coat of superior quality synthetic enamel paint including writing the mes numberon the electric geyserwithsynthetic enamel paint, and refixingon the same location making electrical connection with 3 core copper conductorflexible cable, testing complete all as specified and as directed by the engr in charge. 123 disconnecting electrical connection, taking down mcb db tpn / spn, kept in safe cousdy of contractor s storetillcompletion of civil works and after completion of civil works cleaning the mcb dband refixingon the same location, making electrical connection, testing complete all as specified and as directed by the engr in charge. 124 disconnecting electrical connection, taking down mcbs of any size and type, kept in safe cousdy of contractor s storetillcompletion of civil works and after completion of civil works cleaning the mcbsand refixingon the same location, making electrical connection, testing complete all as specified and as directed by the engr in charge. 125 material and labour for point wiring with 1.50 sqm single core pvc insulated , unsheathed cable frls h, 1100 volt grade with multi stranded copper conductor drawn through and including medium grade, isi marked, pvc conduit not less than 20 mm dia with accessories, concealed on wall / ceiling surfaces and including provision of 1.50 sqm single core pvc insulated , unsheathed cable frls h, 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size / modules as required at site with earth dolly ( boxesshall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally ) including provision of new covered plate over sunken box for housing themodular switches , modular socket outlets, modularfan regulators etc.for one light / fan / exhaust fan point controlledby one way switch, complete all as specified and as directedby engineer in charge. note : a ) .all chases will be cut by chase cutter only b ) switch, socket outlet and fan regulators to be measured and paid forseparately . 126 description same all as per item no.125but for one 3 pin, 5 amps, socket outlet controlled by one switch on independent board, complete all as specified and as directedby engineer in charge. 127 description same allas per item no. 125 but for one 3 pin 5 amps socket outlet controlled by one switch on same board, complete all as specified and as directedby engineer in charge. 128 description same all as per item no.125butone light point controlled by two way switch complete all as specified and as directedby engineer in charge. 129 description same all as per srl item no 125 here in before but for one socket outlet 15 amp with 2.50 sq mm pvc insulated, unsheathedcable frls h, 1100 volt grade isi marked with multi stranded copper conductor along with 2.50 sqmm pvc insulated , unsheathed cable green colour frls h, 1100 volt grade isi marked with multi stranded copperwire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the engineer in charge. 130 description same all as per srl item no 125 here in before but for one socket outlet 15 amp with 4.00 sq mm pvc insulated, unsheathedcable frls h, 1100 volt grade isi marked with multi stranded copper conductor along with 4.00 sqmm pvc insulated , unsheathed cable green colour frls h, 1100 volt grade isi marked with multi stranded copperwire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the engineer in charge. 131 supply and fix modular switch 1 module, single pole, one way 6 amps flush type, 230 voltscomplete all as specified and as directedby engineer in charge. 132 supply and fix modular switch 1 module, single pole, one way 16 amps flush type, 230 voltscomplete all as specified and as directedby engineer in charge. 133 supply and fix modular switch 1 module, single pole, twoway 6 amps flush type, 230 voltscomplete all as specified and as directedby engineer in charge. 134 s&f modular bell push 6 amp, 1 way, 1 module, 230 volts complete all as specified and as directed by the engineer in charge. 135 supply& fixmodular socket outlet2 / 3 pin combined, 6 amp, one way, two module, 230 voltscomplete all as specified and as directedby engineer in charge. 136 supply& fixmodular socket outlet3 / 3 pin combined, ( 6pin ) , 6 / 16 amp, one way, two module, 230 voltscomplete all as specified and as directedby engineer in charge. 137 s&f electronic fan regulator modular 100 watt, 1 module, 230 volts , 50 hz, ac supply suitable for ceiling fan any type / make / sweep complete all as specified and as directed by the engineer in charge. 138 supply and fix ceiling rose surface type 2 / 3 terminalpolycarbonate, isolated body complete all as specified and as directed by the engineer in charge. 139 supply & fixcalling bell ding dong 230 volt including removing unserviceable bell, complete all as specified and as directed by the engr in charge. 140 s&f9 / 12 watt led light fitting wall mounting fixture ( sketch type ) including led lamp compact and energy efficient epoxy powder coated luminaire and connecting with copper conductor flexible cablefrom ceiling rose to connector of the light as in repair completeall as specified and as directed by the engineer in charge. 141 supply and fixing as in repairindoor decorative led tube light fitting box type 18 / 20 wattwith electronic driver, opal diffuser, high efficient pvc housing body suitable for led tube, high efficient, ac 220 240 volts, 50 hzincluding 18 / 20 watt led tube rod luminaries environment friendly, high efficient, t8 with aluminium extrusion heat sinkand connecting with copper conductor flexible cablefrom ceiling rose to connector of the lightcomplete all as specified and as directedby engineer in charge. 142 supply and fixingled surface mounted bulk head luminaries 8 10 watt with min 800 lumen, industrial model, ip 65, aluminium housing, surge protection including driver & led lampetc complete with all accessories, connecting with copper conductor flexible cablefrom ceiling rose to connector of the light as in repair complete all as specified and as directed by the engineer in charge. 143 s&f as in repair mirror light 9 / 12wattled wall mounting fixture, one feet , aluminium housing compact & energy efficient epoxy powder coated crca light luminaire, connecting with copper conductor flexible cablefrom ceiling rose to connector of the light complete all as specified and as directed by the engineer in charge. 144 s&fled bldg. security light fittings of capacity 20 25 watt made up of die castaluminiumhousing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with ip 65 protection and other connected accessories including electronic driver, service bracketof mild steelpipe 32 mm bore medium grade of length 0.9 mtr with ms clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to ms pipe as required at site and two coats ofsynthetic enamel paintoverone coat of red oxide primer on mild steel work and making electrical connection, as in repair complete all as specified and as directed by the engineer in charge. 145 supply and fix mcb sp, 6 40 amps, 240 volt, 10 ka , b curve as per site requirement including removing old unserviceable mcb complete all as specified and as directed by the engineer in charge. 146 m & las in repair sub main wiring with two run of 6 sqmm pvc insulated , unsheathed cable frls h, 1100 volts grade isi marked with multi stranded copper conductor and one run of 6 sqmm pvc insulated , unsheathed cable frls h, 1100 volt grade isi markedmulti stranded copper conductor as earth continuity conductor connected to common earth dolly including concealed on wall / ceiling surfaces in pvc conduit medium gradeisi marked of adequate size for housing the wires complete all as specified and as directed by the engineer in charge.note: ( i ) thimble / lugs of rating of mcb should be used with wire for fixing in the mcb. ( ii ) three runs of cable and one run of pvc conduit shall be measured and paid as one unit length. 147 material & labourfor earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground ( earth pit not less than 2.25m deep below the ground level ) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earthwire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.earth wire protected by gi pipe 15mm bore ( medium grade ) and connected to earthing test pointas directed and as specified and shown in electrical plate no. 3 of ssr part i ( 2009 ) including necessary concrete pit in pcc ( 1:3:6 ) type c1, pre cast rcc ( 1:2:4 ) type b1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia tmt bars @ 15cm c / cboth ways with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia gi pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testingas in repair complete all as directed by engineer in charge and earth testing on completion . 148 material and labour cutting of existing walls in circular / square shape for making opening suitable for fixing 300 mm sweep exhaust fan and15 mm thick cement plaster on any faces of brick wallincement mortar 1:4, finishedeven and fair without using extra cement and applying two coats of white lime wash complete all as specified and as directed by the engineer in charge. 149 supply and fixingheavy duty exhaust fan 300mm sweep with corrosion resistant metallic body, minimum noise, operation and maintenance free design, totally enclosed, highly efficient, heavy duty motor with pressure die cast aluminium rotor mounted on two ball bearings, aerodynamically contoured blades, metallic base framewith rubbermountings for silent operation, maximum watt input not more than 55 watt, 1400 rpm, metal blades and shutter type louvers self openable / closeble for protecting the entrance of birds as per is :2132 1967 and testing complete all as specified and as directedby engineer in charge. 150 note: amount of credit ofrs. 72, 957.00 for retrieved materials is mentioned in schedule of credit page no. 47to 48 of tender documents in pdf form which will be deducted offline while acceptance of tender....
Due Date : November 20, 2023
Tender Value : ₹ 38 Lakhs