Department Of Heavy Industry - Haryana

39037133 bids are invited for misc electrical items mse contactor 3tf46 , contactor 3tf31 , contactor 3tf32 , contactor 3tf33 , contactor 3tf34 , overload relay 3ua58 00 2fz1 , overload relay 3ua55 00 2c , overload relay 3ua52 00 2b , overload relay 3ua50 00 1j , overload relay 3ua50 002s , pvc insulated copper flexible cable 2core 1sqmm , pvc copper cable 1119250 1sqmm 50 core , pvc insulated copper flexible cable 8core 1sqmm , pvc insulated copper flexible wire red color 1sqmm , pvc insulated copper flexible wire black color 1sqmm , pvc insulated copper flexible wire blue color 1sqmm , pvc connector suitable for connecting 1sqmm wire along with blanker plates , pvc tape , selector switch with 3positions , mcb double pole 10amp , air flow switch , smps power supply 230vac , start green led light push button with no element , stop red led light push button with nc element , cable tie 250mm , pvc u clip 20mm , pvc u clip 50mm total quantity : 1145...

Haryana Power Generation Corporation Limited - Haryana

36850333 supply of flow switch, position transmitter and dew point meter , supply of flow switch, position transmitter and dew point meter as per details given at annexure i and ia , flow switch, model: mn dsf320lm 16 1050v.9 a2wl st 175d,make: universal flow monitors inc., usa, set point 175lpm( going down, d) or equivalent , position transmitter:2 – wire contactless, input angle range : 0 to 90 degree, output: 4 20ma dc, operating power supply: 10vdc to 60 vdc, ingress protection: ip67, operating temperature: 0 to 80 deg c , online dew point meter series: s5; instrument number: mts5zx071164y; rated voltage: 220vac; power:4w; geoelectric host no. 5 13820e; sensor no. 347195 pr including installation at site detail as per annexure ia...

Northern Railway - Haryana

35845361 supply of air flow switch model no: bimco 1001, contact rating ( voltage & current ) universal max.230v, 5a forlhb power car. make : bimco [ warranty period: 30 months after the date of delivery ] ...

Military Engineer Services - Haryana

34977589 repair / maintenance of central air conditioning plant including misc items in zone a, zone b and zone c at af stn ambala under ge ( af ) ambala repair / maint of central air conditioning plant including misc items in zone a, zone b and zone c at af stn ambala under ge ( af ) ambala preventive, comprehensive & periodical maintenance / breakdown maintenance ofwater cooled scroll chiller plant of capacity 3x52tr / 3x50tr, checking servicibility of theparts of microprocessor based control panel such as microcontroller cards, sensors, relays, contactor, switches etc., compressor oil checking, checking of leakage of refrigerant piping etc. and descaling of condensor with suitable descaling chemical complete all as specified & directed. location: darin ii & nglgk make: blue star, model no: xwc4s 052ar2 2 preventive, comprehensive & periodical maintenance / breakdown maintenance of water cooled scroll chiller plant of capacity 3x37.7tr, checking servicibility of the parts of microprocessor based control panel such as microcontroller cards, sensors, relays, contactor, switches etc., compressor oil checking, checking of leakage of refrigerant piping etc.and descaling of condensor with suitable descaling chemical complete all as specified & directed. location: atcmake: blue star, model no: xwc3s 039ar2 3 preventive, comprehensive & periodical maintenance / breakdown maintenance ofwater cooled scroll chiller plant of capacity 3x25tr, checking servicibility of theparts of microprocessor based control panel such as microcontroller cards, sensors, relays, contactor, switches etc., compressor oil checking, checking of leakage of refrigerant piping etc. and descaling of condensor with suitable descaling chemical complete all as specified & directed. location: base ops, mcw, esc bay, storage iii & wsamake: blue star, model no: xwc2s 026ar2 4 preventive, comprehensive & periodical maintenance / breakdown maintenance ofwater cooled scroll chiller plant of capacity 3x25tr, checking servicibility of theparts of microprocessor based control panel such as microcontroller cards, sensors, relays, contactor, switches etc., compressor oil checking, checking of leakage of refrigerant piping etc. and descaling condensor with suitable descalingchemical complete all as specified & directed.location: second line service buildingmake: voltas, model no: wcuds 027dmn 5 preventive, comprehensive & periodical maintenance / breakdown maintenance ofwater cooled scroll chiller plant of capacity 3x12.5tr, checking servicibility of theparts of microprocessor based control panel such as microcontroller cards, sensors, relays, contactor, switches etc., compressor oil checking, checking of leakage of refrigerant piping etc. and descaling of condensor with suitable descalingchemical complete all as specified & directed.location: storage i & iimake: voltas, model no: wcuds 014dmn1x1 6 notes for boq item no. 1.00 to 5.00 here in before: ( i ) the descaling chemicalshould be non corrosive and non polluting in nature and safe to handle. descaling chemical compound is rxsol 41 8865 25. makes of desclaing chemical compound are scalebreak / vizag chemical / chemtex / west india chemical. ( ii ) the job includes all three units, condensers & cleaningand re assembling the complete plant after necessary maintenance and shall be measured as one job.. ( iii ) restarting and maintaining of the required / desired parameters should be provided by thecontractor. ( iv ) all the cleaning equipment i.e brush, cotton clothes, nuts, bolts of ciwashers etcas required of suitable sizesare included in quoted rates. ( v ) date wise record of stage passing register maintained when servicing of each unit of each plant alongwith consumable used in each unit to be maintained dully signed by contractor, je & engineer in charge. 7 preventive, comprehensive & periodical maintenance / breakdown maintenance ofair cooled scroll chiller plant of capacity 2x37.7tr, checking servicibility of theparts of microprocessor based control panel such as microcontroller cards, sensors, relays, contactor, switches etc., compressor oil checking, checking of leakage of refrigerant piping etc. and cleaning of condensor coil, servicing of condensor fan motor of chiller plant complete all as specified & directed. location: jaguar simulatormake: blue star model no. xac3s 036ma 8 preventive, comprehensive & periodical maintenance / breakdown maintenance ofair cooled scroll chiller plant of capacity 3x24tr, checking servicibility of theparts of microprocessor based control panel such as microcontroller cards, sensors, relays, contactor, switches etc., compressor oil checking, checking of leakage of refrigerant piping etc. and cleaning of condensor coil, servicing of condensor fan motor of chiller plant complete all as specified & directed. location: wwr storage iv & vmake: blue star model no. xac2s 024ma 9 notes for boq item no. 1.00 to 7.00 here in before: ( i ) the preventive, comprehensive & periodical maintenance / breakdown maintenance services shall be done through oem i.e. voltas or blue star. ( ii ) the contractor shall submit a mou signed by oem on stamp paper duly notarized, as per performa specified here in after alongwith a copy of annual maintenance contract from oem before commencement of work, failing which the contract will be liable to be cancelled and work shall be got executed at the risk & cost of the contractor. ( iii ) contractor will arrange oem visits for inspection and to check the functionality of the plants including maintenance services as required and shall provide state of chiller plant as & when and any no. of time as directed by engineer in charge. ( iv ) any breakdown intimated shall be attended within 48 hours failing which contractor shall be liable for a penalty of rs. 2000.00 for every 24hrs beyond initial 48hours. ( v ) the maintenance shall run for one year from the date of commencement of contract and during this period the smooth funcitoning of plant is responsibility of contractor. ( vi ) the job includes maintenance of all two / three units and re assembling the complete plant after necessary maintenance and shall be measured as one job. 10 notes for boq item no. 1.00 to 7.00 here in before ( contd... / ) : ( vii ) the maintenance of water / air cooled chiller plant at each location shall be considered as each job and payment shall be made accordingly. ( viii ) spare parts, compressor oil, refregerant shall be measured & paid seperetely. cost of minor part which are not catered here in after is deemed to be included in the quoted rates ( ix ) the rates quoted shall be deemed to be inclusive of the all above aspects. ( x ) the taking down of old unserviceable spare parts deemed to be included in quoted rates unless otherwise specifically not mentioned here in after. 11 m&l in replacement of existing micro processor based control panel of make blue star water cooled chiller plant model no: xwc2s 026ar2 with r 22 / 407c refrigerant basedscroll type of 25.1tr capacity complete in all respect with all electrical switchgear including undermentioned accessories complete all as specified & directed. ( i ) mcb c series, 50amp: 02 nos. ( ii ) motor protection device and single phase preventer vsp 3 : 02 nos. ( iii ) relay ( iv ) sensing transformer :02 nos. ( v ) contactor mnx50 :02 nos. ( make of contactor / switch gear : l&t, siemens, schneider ) ( vi ) current transformer100 amp / 05: 02 nos. ( vii ) printed circuit board ( pcb ) with display unit: 01 no.location: wwr building 12 m&l in replacement of existing micro processor based control panel of make blue star water cooled chiller plant model no: xwc4s 052ar2 with r 22 / 407c refrigerant basedscroll type of 50 / 52tr capacity complete in all respect with all electrical switchgear including undermentioned accessories complete all as specified & directed. ( i ) mcb c series, 50amp: 04 nos. ( ii ) motor protection device and single phase preventer vsp 3 : 04 nos. ( iii ) relay ( iv ) sensing transformer :04 nos. ( v ) contactor mnx50 :04 nos. ( make of contactor / switch gear : l&t, siemens, schneider ) ( vi ) current transformer 100 amp / 05: 04 nos. ( vii ) printed circuit board ( pcb ) with display unit: 01 no.location: nglgk 13 m&l in replacement of existing micro processor based control panel of make blue star water cooled chiller plant model no: xwc3s 039ar2 with r 22 / 407c refrigerant basedscroll type of 37.7tr capacity complete in all respect with all electrical switchgear including undermentioned accessories complete all as specified & directed. ( i ) mcb c series, 50amp: 03 nos. ( ii ) motor protection device and single phase preventer vsp 3 : 03 nos. ( iii ) relay ( iv ) sensing transformer :03 nos. ( v ) contactor mnx50 :03 nos. ( vi ) current transformer 100 amp / 05: 03 nos. ( vii ) printed circuit board ( pcb ) with display unit: 01 no.location: atc 14 notes for boq item no. 8.00 to 10.00: ( a ) the job includes replacement of complete internal and outer micorcontroller cards and display to achieve following conditions as undermentioned. micro processor based controller shall be as per following specification: ( i ) local mode: start / stop through touch screen. ( ii ) equalization of compressor runtime. ( iii ) micro processor control should ensure equal run time of compressor. ( iv ) safety and protection ( v ) motor protection device : protects chiller from ?phase unbalance ?phase loss ?phase reversal ?overload ?underload ( vi ) voltage protection device : protects chiller from ?phase loss ?phase reversal 15 notes for boq item no. 8.00 to 10.00 ( continued ) : ( vii ) additional safety features: protects system from ?freezing ?low pressure ? anti recycle ?low chilled water temperature?high pressure ?sensor error ?low water flow in condenser, ( b ) cost of replacement of field devices, chilled water inlet sensor and outlet sensor with their mounting and fixing accessories and high pressure and low pressurecut off switches of make : danfos / indfos deemed to be included in the quoted rate. ( c ) cost of the control panel wiring included in the quoted rate. 16 supply & installation of glycerin filled analogue pressure gauge with gauge cock, having following specification complete all as specified & directed: ( i ) pressure gauge; case & bazel ring : ss 304 ( ii ) snap action bayonet type ( iii ) bourdon & movement : ss 304 ( iv ) pressure element : ss 316 ( v ) ambient temp: 10°c ~ 45°c ( vi ) socket : ss 304 ( vii ) window : toughened glass ( viii ) mounting : bottom center ( ix ) accuracy class: 1.6 as per en 837 1. ( x ) nominal dia size: 100 mm. ( xi ) pointer: not adjustable, aluminum black. ( xii ) gauge cock: gauge cock should be in stainless steel with threaded connection suitable for nominal pressure of 16 bar. ( xiii ) connection size : 1 / 4 bsp. make : dwyer / forbes marshall / warrie / wika 17 supply & installation of thermometer, case and bezel moc shall be cast aluminum 304, weather proof as per ip 65. immersion length around 200 mm, connection 1 / 2 bsp with ss 304 thermowell dully filled with glycerin / equivalent complete all as specified & directed. 18 supply, installation, testing and commissioning of automatic purge valve, moc shall be of brass and plastic cap shall be provided on the outlet to shut the air vent when not in use. there shall be check valve at the bottom to seal the system when the auto air vent is removed for servicing. auto air vent shall be installed on all high points in the water piping system to automatically remove the trapped air. 3 / 8 bsp suitable for maximum operating pressure at 10 bar complete all as specified & directed. 19 s&f water flow switch of model hfs 25 complete all as specified & directed. 20 supply, installation, testing & commisioning of compressor scroll type, 380 to 400volt, 3 phase, 50 hz, thermally protected, lubricant mineral oil 160poe, refigerant type r 22 / 407c of capacity 12.5tr complete all as specified & directed.make: danfoss ( model no: sm185s4rc ) / daikin / copeland / emerson / carriernote: ( i ) the compressor should be installed by the authorisedcompanys refrigerant mechanic. ( ii ) after successful installation, the compressor should be vaccumed by the nitrogen at desired pressure and leakage should be checked. ( iii ) the rate offirst charge of refrigerant gas in the compressor deemed to be included in quoted rates. 21 s&f expansion valve with fixed orifice suitable for every type of refrigeration and air conditioning plants of existing makes and complete all as specified & directed. make: danfoss ( cat part no tgex 11 tr r22 / 407c ) 22 s&f liquid line filter drier / drier core filter as existing complete all as specified & directed.make: danfoss cat part no dcl 305 or equivalent model as recommended by the manufacturers. 23 s&f lwt / ewt ( leaving water temp and entering water temp ) sensors with probe as per the plant capacity alongwith minimum 6mtr of suitable core of copper cable as per existing size complete all as specified & directed. make: danfoss, invotec, abb, indfos. 24 s&f angle valves 1 / 4 x1 / 4complete all as specified & directed. 25 s&f crank case heater for scroll compressor ( 11 tr to 13.1 tr ) complete all as specified & directed. 26 s&f safety valvecomplete all as specified & directed. 27 s&f hrcfusewith holder, 20amp 40amps, 415volt complete all as specified & directed 28 supply & filling / top up of compressor oil, non freezing or as recommended by oem in ac plant including vaccum testing complete all as specified & directed. notes : ( i ) oil shall be brought by the contractor at site from authorised dealer / manufacturer company in sealed canes of standard packing with test certificate and purchase vouchers ( ii ) fillingshall be done in the presence of engineer in charge. 29 supply & charging of refrigerant gas r 407c in plant after detections / rectification of any leakages in the system using n2 gas and flushing the complete system thoroughly with nitrogen gas including pressure test complete all as specified & directed. 30 supply & charging of refrigerant gas r 410a in plant after detections / rectification of any leakages in the system using n2 gas and flushing the complete system thoroughly with nitrogen gas including pressure test complete all as specified & directed. 31 supply & charging of refrigerant gas r 22 in plant after detections / rectification of any leakages in the system using n2 gas and flushing the complete system thoroughly with nitrogen gas including pressure test complete all as specified & directed.notes for boq item no. 24.00 to 26.00 : ( a ) gas to be brought by the contractor at site from the authorised dealer / manufacturer and shall be in companys sealed cylinder and empty cylinders shall be returned to the contractor. ( b ) the unit rate quoted are inclusive of the cost of nitrogen / co2 gas used for leakage test and pressure test prior to filling / charging of gas. 32 supply only refrigerant gas r 22 in sealed cylinder complete all as specified & directed. 33 supply only refrigerant gas r 407c / 410a in sealed cylinder complete all as specified & directed. 34 supply only nitrogen gas in sealed cylinders of 10 kgs gas having pressure rating of 90psi of each cylinder for checking of leakage in all refrigerant piping and compressors complete all as specified & directed. notes for boq item no. 27.00 to 29.00 ( a ) gas to be brought by the contractor at mes store from the authorised dealer / manufacturer and shall be in companys sealed cylinder alongwith purchase vouchers. ( b ) empty cylinders shall be returnedto contractor aftercompletion of contract. 35 m&l periodical servicing of ahus capacity 6000 cfm to 10000 cfm by opening air filter, nut bolts, tray for ahu including cleaning of air filter panel, cleaning of cooling coil bycoil cleaner solution and high pressure water and rectified refrigerant leakage in cooling coilcomplete with brazing and soldering, opening and disconnectning ofahu motor fromblower room checkingseviceability fan, pulley, fan belt and oiling / greasing complete, replacement of unserviciable vibrating pads / springinside of ahufor equal air flow from blower to difuserofany type / capacity blower complete all as specified & directed. 36 m&l periodical servicing of ahus of capacity more than 12000cfm by opening air filter, nut bolts, tray for ahu including cleaning of air filter panel, cleaning of cooling coil bycoil cleaner solution and high pressure water and rectified refrigerant leakage in cooling coilcomplete with brazing and soldering, opening and disconnectning ofahu motor fromblower room checkingseviceabilityofshaft, fan, pulley, fan belt and oiling / greasing complete, replacement of unserviciable vibrating pads / springinside of ahufor equal air flow from blower to difuserofany type / capacity blower complete all as specified & directed. 37 m&l rewinding of ahus electric motor of capacity 15hp to 20hp three phase 415 volts by removing old unserceable burnt copper winding wire, cleaning of slots and insertion of insulating paper in the slots in appropriate size and rewinding with super enameled copper wire of suitable size alongwith insertion of superior quality of insulating material, winding, varnishing and drying, including dismantling of electric motors connections and refixing back after rewinding, replacement of connection plate and making necessary electric connection and testingcomplete all as specified & directed. 38 description all as per boq item no. 32.00 here in before but capacity 5hp to 10hp. 39 description all as per boq item no. 32.00 here in before but capacity 2hp to 3hp. 40 supply, installation, testing & commissioning in replacement 50mm dia electronic, self balancing, pressure independent type dynamic balancing valve with integrated modualating control valves in a single body. the actuator shall be capable of accepting upto 10volt dc and upto 20ma electric signal and shall provide similar transduced feedback output to control system. maximum close off pressure shall not be less than 6bar for upto 50mm valves and not be less than 7bar for 65mm & above. valves should have pressure rating of 25bar minimum. valve & actuator combination should be able to give logarithmic control characteristics to achieve linear control.the valve shall have manual override facility & the scope shall include proportionate thermostat, transformer as required and wiringfor interconnection with 1.5sqmm copper conductor multicore armoured cable complete all as specified & directed. make:honeywell, siemens, danfoss 41 s&f in replacement pre fine air filters panel of size 20 x 20 x 2inch for dust filtration of particles up to 5microns at 99% efficiency having air velocity through the filter approx 350 to 400 fpm complete all as specified & directed.make : zenith filters / afi / spectraco / asian filters 42 servicing of cooling towerof varying capacity 15tr to 50tr ac plant, dismantling of cooling tower for removing of top cover andreplacement of pvc frills and unserviceable nozzle, replacement of rusted nuts, bolts with washers etc and cleaning bottom tank to remove mud and dust complete all as specified & directed.note: spare parts i.e. float valve, pvc nozzels shall be measured & paid separately. 43 description all as per boq item no. 37.00 here in before but capacity more than 50tr. 44 m&l rewinding of electric fan motor of different cooling towers of capacity 2hp to 5hp, three phase 415 volts by removing old unserviceable burnt copper winding wire, cleaning of slots and insertion of insulating paper in the slots in appropriate size and rewinding with super enameled copper wire isi markedof suitable sizealongwith insertion of superior quality of insulating material, winding, varnishing and drying, including dismantling of electric motors connections and refixing back after rewinding including replacement of connection plate and making necessary electric connection and testingcomplete all as specified & directed. 45 s&f in replacement triple layer isi marked rotational molded polyethylene water storage tanks ( cylindrical vertical with closed top ) hoisted and fixed in position of capacity 5000 liters complete all as specified & directed. 46 s&f in repair galvanized wire mesh with wire of 1.40 mm dia, mesh size not less than 25 mm fixed on cooling tower by nut / bolts etc. complete all as specified & directed. 47 s&f in repair pvc float valve assembly 25 / 20mm complete all as specified & directed. 48 s&f in repair pvc nozzles as per existing complete all as specified & directed. 49 m&l water hydra / sprinkler for cooling tower of capacity 15tr to 50tr ac plant by dismantling of cooling tower electric motor and disconnecting all pvc nozzles from hydra and taking dwon & replacement of the same as per existing size / model hydra for suitable water flow by pvc nozzles withreplacement of rusted nuts, bolts with washers etccomplete all as specified & directed. 50 description all as per boq item no. 44.00 here in before but capacity more than 50tr. 51 s&f in replacement multi blade propeller fan of cooling tower having capacity of 15tr to 50tr . thefan blade construction moc should be aluminium alloy / frp as per existing at site complete all as specified & directed. note: sample shall be taken from site. 52 s&f in replacement drift eliminator of cooling tower having capacity of 50tr to 75tr as per existing at site complete all as specified & directed. 53 m&l in replacement of pvc fill blocks of size 600mm x 300mm x 150mm complete all as specified & directed. 54 s&f in replacement of air cooled condensor fan of size 660mm complete all as specified & directed. ac plant model no xac3s 036ma / xac2s 024mamake: delta 55 m&l in replacement ms pipe heavy grade of size 200mm bore with all fittings, welding, testings etc. laid in floors or fixed to walls and ceilings etc of sizes including providing two coats of anti corrosive paint over & including one coat of primers on external surfaces of pipes complete all as specified & directed. 56 description all as per boq item no. 50.00 here in before but size 150mm bore. 57 description all as per boq item no. 50.00 here in before but size 100mm bore. 58 description all as per boq item no. 50.00 here in before but size 80mm bore. 59 m&l in replacement gi pipe 50mm bore medium grade isi markedwith all fittings laid in floors or fixed to walls and ceilings etc complete all as specified & directed. 60 description all as per boq item no. 54.00 here in before but 40mm bore. 61 description all as per boq item no. 54.00 here in before but 25mm bore. 62 description all as per boq item no. 54.00 here in before but 20mm bore. 63 supply, fixing & testing in replacement butterfly valve ( manual ) size 150mm with ci body ss disc, insulated, nitrile rubber seal & o ring pn 16 pressure rating for chilled water / hot heater circulation complete all as specified & directed.make: castle, zoloto, sant, venus 64 description all as per boq item no. 58.00 here in before but size 100mm. 65 description all as per boq item no. 58.00 here in before but size 80mm. 66 description all as per boq item no. 58.00 here in before but size 50mm / 40mm. 67 s&f in replacement non return valve, size 150mm with dual plate of ci body ss plates vulcanized nbr seal flanged end & pn 16 pressure rating for chilled / hot water circulation including insulation complete all as specified & directed. make : audco, honeywell, intervalve, ksb, vtm 68 description all as per boq item no. 62.00 here in before but size 100mm. 69 description all as per boq item no. 62.00 here in before but size 80mm. 70 description all as per boq item no. 62.00 here in before but size 50mm / 40mm. 71 s&f in replacement y strainer size 150mm of ductile ci body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation complete all as specified & directed. 72 description all as per boq item no. 66.00 here in before but size 100mm. 73 s&f in replacement of gun metal gate valve isi marked including cutting / threading and welding to existing gi pipe of size 50mm dia complete all as specified & directed. 74 description all as per boq item no. 68.00 here in before but size 40mm dia. 75 description all as per boq item no. 68.00 here in before but size 25mm dia. 76 description all as per boq item no. 68.00 here in before but size 20mm dia. 77 m&l rewinding of condensor and chilled water electric motor of capacity 7.5hp to 12.5hp, three phase 415 volts by removing old unserviceable burnt copper winding wire, cleaning of slots and insertion of insulating paper in the slots in appropriate size and rewinding with super enameled copper wire isi markedof suitable sizealongwith insertion of superior quality of insulating material, winding, varnishing and drying, including dismantling of electric motors connections and refixing back after rewinding, replacement of connection plate and making necessary electric connection and testingcomplete all as specified & directed. 78 description all as per boq item no. 72.00 here in before but capacity 3hp to 5hp. 79 decoupling of monoblock pump from electric motor, dismantling from the foundation and shifting to local workshopfor repair / overhauling of monoblock pumping set capacity 7.5hp to 12.5hp ( condensor and chilled water pump ) taking out impeller bush bearing shaft stuffing box reassembling the same after replacing the defective parts & carrying out the necessary repair remetallingturning polishing the pump shaft replacement including replacement of steel studs and unserviceable nuts and bolts repair / replacement of ball bearing impellor stuffing box greasing etc and testing on completion and commisioning and installation at site complete all as specified & directed.notes: ( i ) the complete job includes making good the existing pumps water leakage proof. ( ii ) cost of the spare parts except gm bush, impeller, stuffing box and ball bearing shall deemed to be included in the quoted rate. 80 s&f bearing for 7.5hpto 12.5hp pumpsets complete all as specified & directed.make: skf / nbc 81 s&f bronze / gm impeller of pumpset of capacity 7.5hpto 12.5hp complete all as specified & directed. 82 s&f stuffing box alongwith pressure plate and hexa nuts studds etc required for gland packing and pump shaft as per existing make pumpset of capacity 7.5hpto 12.5hp complete all as specified & directed. 83 s&f gun metal bush of pumpset of capacity 7.5hp to 12.5hp complete all as specified & directed. 84 decoupling of monoblock pump from electric motor, dismantling from the foundation and shifting to local workshopfor repair / overhauling of monoblock pumping set capacity 3hp to 5hp ( condensor and chilled water pump ) taking out impeller bush bearing shaft stuffing box reassembling the same after replacing the defective parts & carrying out the necessary repair remetallingturning polishing the pump shaft replacement including replacement of steel studs and unserviceable nuts and bolts repair / replacement of ball bearing impellor stuffing box greasing etc and testing on completion and commisioning and installation at site complete all as specified & directed.notes: ( i ) the complete job includes making good the existing pumps water leakage proof. ( ii ) cost of the spare parts except gm bush, impeller, stuffing box and ball bearing shall deemed to be included in the quoted rate. 85 s&f bearing for 73hpto 5hp pumpsets complete all as specified & directed.make: skf / nbc 86 s&f bronze / gm impeller of pumpset of capacity 3hpto 5hp complete all as specified & directed. 87 s&f stuffing box alongwith pressure plate and hexa nuts studds etc required for gland packing and pump shaft as per existing make pumpset of capacity 3hpto 5hp complete all as specified & directed. 88 s&f gun metal bush of pumpset of capacity 3hp to 5hp complete all as specified & directed. 89 s&f in replacement gland packing for monoblock pumpset / centrifugal end suction pumpset of capacity 3hp to 15hp as per existing make complete all as specified & directed. 90 m&lattending day to day complaints pertainsto ac plant of any capacity as and when required with skilled refregeration mechanic / electrician & helper alongwith necessary t&pfor checking the equipment at existing location and find out the faults / defects and rectify the defects in situ and cleaning / normal maintenance to the equipments ( including lugs wire phase preventer, nuts, bolts etc as required on site ) complete to make the equipment functional in all respect complete all as specified & directed.note : ( i ) spare parts shall be measured and paid separately except minor items like thimbles / lugs wire etc. ( ii ) taking out / down & fixing of new spare parts included in quoted rates unless otherwise specifically not mentioned here in after. 91 supply only single phase preventer system of supply 415volt, 50hz model vsp2 of make minilec or equivalent of l&t / abb complete all as specified & directed 92 supply only auxiliary contactormnx a 2 for 415volt 10amps for contactor25amp complete all as specified & directed.make: l&t, havells, legrand 93 supply only contactor mnx 25 40 amp complete all as specified & directed make: l&t, havells, legrand 94 supply only contactor mnx 50 70 amp complete all as specified & directed make: l&t, havells, legrand 95 supply only contactor mnx 18 amp complete all as specified & directed make: l&t, havells, legrand 96 supply only side mounting add on block with aux contact 1no+1nc suitable for mnx 9 to 40amp contactor of complete all as specified & directed. make: l&t, havells, legrand 97 supply only electronic timers type et 100, 110 / 240 volt, 50 hz complete all as specified & directed. 98 supply only timer gt 200 complete with coilvoltage 220volt complete all as specified & directed.make: bch, l&t 99 supply only overload relay 6 to 10 amps, 3 pole, directly operated complete all as specified & directed.make: bch, l&t 100 supply only overload relay 9 to 14 amp 3 pole, directly operated complete all as specified & directed.make: bch, l&t 101 supply only overload relay 20 to 32 amp 3 pole, directly operated complete all as specified & directed.make: bch, l&t 102 supply only overload relay 28 to 42 amp 3 pole, directly operated complete all as specified & directed.make: bch, l&t 103 supply only selector switch 4 way for voltmeter complete all as specified & directed. 104 supply only toggle switch spst 10 amps complete all as specified & directed. make: kayceel, l&t 105 supply only voltmeter 0 500volt digital type, complete all as specified & directed.make: ae, crompton greaves 106 supply only ammeter0 100amps digital type, complete all as specified & directed.make: ae, crompton greaves 107 supply only mcb 25 amp to 63 amp triple pole complete all as specified & directed. 108 supply only mcb 16 amp to 32 amp, triple pole neutral complete all as specified & directed. 109 supply only mcb 40 amp to 100 amps, triple pole neutral complete all as specified & directed. 110 supply only mccb, adjustablethermal and adjustable magnetic setting of capacity 250amp, 415volt, four pole, 36 kacomplete all as specified & directed 111 supply only mccb, adjustablethermal and adjustable magnetic setting of capacity 200 amps, 415volt, four pole, 36 ka complete all as specified & directed 112 supply only mccb, adjustablethermal and adjustable magnetic setting of capacity 160 amps, 415volt, four pole, 36 ka complete all as specified & directed 113 supply only mccb, adjustablethermal and adjustable magnetic setting of capacity 125 amps, 415volt, four pole, 16 ka complete all as specified & directed 114 supply only mccb, adjustablethermal and adjustable magnetic setting of capacity 100 amps, 415volt, four pole, 16 ka complete all as specified & directed 115 supply only mpcb, thermal magnetic release and adjustable setting of capacity 9 to 13 amps, 415volt, three pole, 25 ka complete all as specified & directed 116 supply only mpcb, thermal magnetic release and adjustable setting of capacity 11 to 17 amps, 415volt, three pole, 20 ka complete all as specified & directed 117 m&l in replacement pvc insulated, armoured, shielded , multistranded copper conductor cable for instrumentation havingsignal capacity of ( 4 20 ) ma / 24vac / 24vdc of size 01 sqmm 4 core including saddles, & screws with laying in & including ms conduit light gradeperfectly complete all as specified & directed. 118 s&f in replacement ofcomplete set of heating element 220 / 380 volts or required for 63kilowatt hot water generator complete all as specified & directed.. 119 s&f in replacement of electric strip heaters3 kilowatt capacity isi marked complete all as specified & directed. 120 m&l in replacement to suction / discharge valve of teflon sheet ‘o’ ring etc complete all as specified & directed. 121 m&l in replacement for providing thermal insulation to supply air ducts / return air ducts with 32 mm thick , epdm rubber with factory laminated glass cloth 7mil, 200 gsm sheet, use adhesive fevicol sr 998, joint should be sealed withtape of at least2 wide ( standard type ) and finished withcoating of fevicol ac duct king lag coating af: 5590 and finally finish with uv resistance paint as per client choice complete all as specified & directed. 122 s&f in replacement pin up display board of wooden of size 2x3 feet alongwith 50 pins complete to pin up the fire safety orders, sop, standing orders for the ac plants complete all as specified & directed. 123 supply, installation, testing & commisioning ofpump suitable for 7.5hp electric motor, bronze / ss impeller, gm bushes, stuffing box and making all connection with existing condensor and chiller system complete with all accessories / pipe fittings including taking down of existing pump and making connections to starter complete all as specified & directed. 124 supply, installation, testing & commisioning of monoblock pump set of motors capacity 2 / 3 hp electric motor 3 phase 415 volt, ie3 and making all connection with existing condesor and chiller system complete with all accessories / pipe fittings includingtaking down of existing pump and making connections to starter complete all as specified & directed. 125 supply, installation, testing & commisioning of electric motor of capacity 7.5hp for prime mover of pumpset, 3 phase 415 volt, ie3 and making all connection with existing condesor and chiller system complete with all accessories / pipe fittings includingtaking down of existing electric motor and making connections to starter complete all as specified & directed. 126 description all as per boq item no. 120.00 here in before but capacity 5hp. 127 description all as per boq item no. 120.00 here in before but capacity 1 / 2hp. 128 s&f electrical insulating rubber mat of size ( 2mtr x 1mtr x 3mm ) tested for lt voltage 1100 volts complete all as specified & directed. 129 m&lfor spray painting to central ac plant completecomprisingof compressors, motors, condensor, cooling tower and cooling tower pumps, pump / monoblocks, ms / gi pipe lines of sizes etc after preparation of old painted surface as per colour code includingand marking arrow, sm / mes nos, colour for 11 to 100tr acs plantcomplete all as specified & directed. 130 s&f v belt of size a 50 / 54 / 65 / 81, b 47 / 56 / 59 / 70 / 72 / 75 / 76 / 78 / 80 / 82 / 90 / 94 / 101 / 102 / 103, c 107 complete all as specified & directed. 131 s&f in replacement outdoor fan of package type ac plant of capacity 17tr, suitable for plant of make bluestar, model no dpa2163r3 i. the moc of the fan blade shall be frp type complete all as specified & directed. 132 s&f in replacement outdoor fan of package type ac plant of capacity 11tr, suitable for plant of make bluestar, model no dpa1441r3 i. the moc of the fan blade shall be frp type complete all as specified & directed. 133 m&l for descaling and cleaning oftubes of condenser ( heat exchanger ) unit, tube of central ac plant including opening and refixing in original position all as required at site for shell and tube condensor unit of package type ac plant by using proper descaling solution by suitable size of drill rod, wire brush, cleaning by circulating pressure water by pressure pumps till the complete deposits / scale is removed as ordered, replacement of packing gasket, nuts, bolts with washer of both ends of condensor complete all as specified & directed. 134 s&f, testing & installation ofduct mounted temperature and rh transmitter with digital display complete all as specified & directed.. make: invotec / honeywell / danfoss. 135 m&l for writing sm / mes no. with suitable paint / color ( as approved ) on the ac ( window / split type ) , coolers / desert coolers, water coolers etc possessed by user complete all as specified & directed. note: contractor shall deploy his painter who will approach the user with the permission of department and shall write sm / mes no. and quoted rate deemed to be included the cost of visit of deployed painter to user. 136 s&f in replacement balancing valve of size 80mm with built in flow measuring facility with ci body flanged construction with epdm coated disc with long pitch with protected out pipe insulation & pn 16 pressure rating for chilled / hot water circulation complete all as specified & directed. 137 description all as per boq item no. 131.00 here in above but size 50mm. 138 for credit schedule, refer tender documents. the amount of credit schedule shall be deducted from total quoted amount of boq to arrive contract sum....

Bharat Heavy Electricals Limited - Haryana

33838293 supply and etc of acvs items for 220 kv gis for iocl panipat supply and etc of acvs items for 220 kv gis for iocl panipat , supply steam control valve , supply condensate transfer pump set ( condensate transfer pump with drive ) , supplychilled water pump sets ( chilled water pump with drive ) , supplydesuperheating pump ( desuperheating pumps with drive ) , supplypressure reducing desuperheating station ( prds ) , supplycs pipe 150 mm dia ( confirming to astm a106 gr b, seamless ) , supplycs pipe 100 mm dia ( confirming to astm a106 gr b, seamless ) , supplycs pipe 40 mm dia ( confirming to astm a106 gr b, seamless ) , supplycs pipe 25 mm dia ( confirming to astm a106 gr b, seamless ) , supplyms pipe 200 m dia ( confirming to is : 3589 ) , supplyms pipe 25 mm dia ( confirming to is: 1239 part 1 ) , supplybalancing valve 200 mm dia , supplybalancing valve 150 mm dia , supplygate valve 200 mm dia , supplynon return valve 150 mm dia , supplynon return valve 40 mm dia , supply3 way mixing valve ( size shall be as per requirement ) , supplyball valve 25 mm dia , supplyy strainer 200 nb ( t strainer ) , supplyy strainer 150 nb , supplyy strainer 50 nb , supplyy strainer 25 nb , supplycs gate valve 150 nb confirming to astm astm a216 gr. wcb , supplycs gate valve 100 nb confirming to astm astm a216 gr. wcb, for steam line , supplycs gate valve 40 nb confirming to astm a105, for condensate line , supplycs gate valve 25 nb confirming to astm a105 , supplyair filter regulator , supplythermodynamic steam trap , supplyflexible rubber coupling , supplyautomatic air vents , supplyinsulated condensate tank ( insulated condensate tank with instruments ) , supplythermal insulation for chilled water piping 150 nb ( cold insulation ) , supplythermal insulation for steam piping 100 nb , supplythermal insulation for steam piping 50 nb , supplyair handling unit ( ahu ) ( 59000 cfm double skinned air handling units complete with filters, cooling coil with motor, v belt drive, flexible canvas connection etc. ) , supplymotorised volume control damper , supplymotorised actuator for volume control damper , supplymake up water tank ( insulated make up water tank with instruments ) , supplyvolume control damper ( duct mounted volume control dampers ) , supplymotorised fire damper , supplymotorised actuator ( actuators for operating the fire dampers ) , supplychemical filter unit ( 9500 cfm fresh air system with chemical filter unit, pre filter, fine filter & centrifugal fans for ahu room ) , supplynon return damper ( non return damper for fresh air fan ) , supplygss duct sheet18 gair conditioning system ( supply & return air gss ducts with duct supports & accessories as applicable ) , supplygss duct sheet20 gair conditioning system ( supply & return air gss ducts with duct supports & accessories as applicable ) , supplygss duct sheet22 gair conditioning system ( supply & return air gss ducts with duct supports & accessories as applicable ) , supplygss duct sheet24 gair conditioning system ( supply & return air gss ducts with duct supports & accessories as applicable ) , supplythermal insulation for supply air duct , supplythermal insulation for return air duct , supplyaccoustic insulation , supplysupply air grill with vcd , supplyreturn air grill with vcd , supplysupply air diffuser with collar damper , supplyreturn air diffuser with collar damper , supplystrip heaters ( electric strip heaters for winter heating / monsoon dehumidification ontrols like humidistats, thermostats etc. as required ) , supplystrip heater 20 kw capacity with controls ( electric strip heaters for winter heating / monsoon dehumidification ontrols like humidistats, thermostats etc. as required ) , supplypan humidifier ( pan type humidifier for humidification during winter in ahu room ) , supplytemperature gauge , supplythermostat , supplygeyserstat , supplyhumidistat , supplytemperature cum rh sensor , supplyair flow switch , supplyinclined tube manometer , supplypressure gauge , supplylevel gauge , supplythermometer ( digital thermometer ) , supplythermowell , supplywater flow switch , supplydp switch , supplyjunction box ( jb in ahu room & ac plant room for wiring of field devices to plc panel ) , supplyplc panel ( plc based centralized automatic control panel for the hvac system with provision for human machine interface with alarm and anunciation facility ) , supplyannunciation panel ( audio visual annunciation panel ) , supplyaxial flow exhaust fans with flp motor7500 cmh ( axial flow exhaust fans ( bifurcated type, spark proof construction, wall mounted ) complete with casing, flame proof motor & mounting frame, ms rain protection cowl, bird screen and all other accessories epoxy painted ( suitable for 415v / 3 phase supply ) , capacity 7, 500 cmh, static 15 mmwc , axial flow exhaust fans4000 cmh ( axial flow exhaust fans ( wall mounted ) complete with casing, motor & mounting frame, ms rain protection cowl, bird screen and all other accessories ( suitable for 415v / 3 phase supply ) . capacity 4, 000 cmh, static 10 mmwc. , supplyaxial flow exhaust fans10000 cmh ( axial flow exhaust fans ( wall mounted ) complete with casing, motor & mounting frame, ms rain protection cowl, bird screen and all other accessories ( suitable for 415v / 3 phase supply ) . capacity 10, 000 cmh, static 10 mmwc. , supplychain pulley block , supply maintenance tools & tackles ( as per clause 5.5.0 ( e ) of section 1 of technical specification , supply mechanical seal for pumps , supply v belt ( spare for ahu ) , supply pre filter ( spare for ahu ) , supply fine filter ( spare for ahu ) , supply bearing ( de & nde ) ( spare for ahu motor ) , supply terminal studs / bushing assembly ( spare for ahu motor ) , supply washer , etc steam control valve , etc condensate transfer pump set ( condensate transfer pump with drive ) , etc chilled water pump sets ( chilled water pump with drive ) , etc desuperheating pump ( desuperheating pumps with drive ) , etc pressure reducing desuperheating station ( prds ) , etc cs pipe 150 mm dia ( confirming to astm a106 gr b, seamless ) , etc cs pipe 100 mm dia ( confirming to astm a106 gr b, seamless ) , etc cs pipe 40 mm dia ( confirming to astm a106 gr b, seamless ) , etc cs pipe 25 mm dia ( confirming to astm a106 gr b, seamless ) , etc ms pipe 200 m dia ( confirming to is : 3589 ) , etc ms pipe 25 mm dia ( confirming to is: 1239 part 1 ) , etc balancing valve 200 mm dia , etc balancing valve 150 mm dia , etc gate valve 200 mm dia , etc non return valve 150 mm dia , etc non return valve 40 mm dia , etc 3 way mixing valve ( size shall be as per requirement ) , etc ball valve 25 mm dia , etc y strainer 200 nb ( t strainer ) , etc y strainer 150 nb , etc y strainer 50 nb , etc y strainer 25 nb , etc cs gate valve 150 nb confirming to astm astm a216 gr. wcb , etc cs gate valve 100 nb confirming to astm astm a216 gr. wcb, for steam line , etc cs gate valve 40 nb confirming to astm a105, for condensate line , etc cs gate valve 25 nb confirming to astm a105 , etc air filter regulator , etc thermodynamic steam trap , etc flexible rubber coupling , etc automatic air vents , etc insulated condensate tank ( insulated condensate tank with instruments ) , etc thermal insulation for chilled water piping 150 nb ( cold insulation ) , etc thermal insulation for steam piping 100 nb , etc thermal insulation for steam piping 50 nb , etc air handling unit ( ahu ) ( 59000 cfm double skinned air handling units complete with filters, cooling coil with motor, v belt drive, flexible canvas connection etc. ) , etc motorised volume control damper , etc motorised actuator for volume control damper , etc make up water tank ( insulated make up water tank with instruments ) , etc volume control damper ( duct mounted volume control dampers ) , etc motorised fire damper , etc motorised actuator ( actuators for operating the fire dampers ) , etc chemical filter unit ( 9500 cfm fresh air system with chemical filter unit, pre filter, fine filter & centrifugal fans for ahu room ) , etc non return damper ( non return damper for fresh air fan ) , etc gss duct sheet18 gair conditioning system ( etc & return air gss ducts with duct supports & accessories as applicable ) , etc gss duct sheet20 gair conditioning system ( etc & return air gss ducts with duct supports & accessories as applicable ) , etc gss duct sheet22 gair conditioning system ( etc & return air gss ducts with duct supports & accessories as applicable ) , etc gss duct sheet24 gair conditioning system ( etc & return air gss ducts with duct supports & accessories as applicable ) , etc thermal insulation for etc air duct , etc thermal insulation for return air duct , etc accoustic insulation , etc etc air grill with vcd , etc return air grill with vcd , etc etc air diffuser with collar damper , etc return air diffuser with collar damper , etc strip heaters ( electric strip heaters for winter heating / monsoon dehumidification ontrols like humidistats, thermostats etc. as required ) , etc strip heater 20 kw capacity with controls ( electric strip heaters for winter heating / monsoon dehumidification ontrols like humidistats, thermostats etc. as required ) , etc pan humidifier ( pan type humidifier for humidification during winter in ahu room ) , etc temperature gauge , etc thermostat , etc geyserstat , etc humidistat , etc temperature cum rh sensor , etc air flow switch , etc inclined tube manometer , etc pressure gauge , etc level gauge , etc thermometer ( digital thermometer ) , etc thermowell , etc water flow switch , etc dp switch , etc junction box ( jb in ahu room & ac plant room for wiring of field devices to plc panel ) , etc plc panel ( plc based centralized automatic control panel for the hvac system with provision for human machine interface with alarm and anunciation facility ) , etc annunciation panel ( audio visual annunciation panel ) , etc axial flow exhaust fans with flp motor7500 cmh ( axial flow exhaust fans ( bifurcated type, spark proof construction, wall mounted ) complete with casing, flame proof motor & mounting frame, ms rain protection cowl, bird screen and all other accessories epoxy painted ( suitable for 415v / 3 phase etc ) , capacity 7, 500 cmh, static 15 mmwc , axial flow exhaust fans4000 cmh ( axial flow exhaust fans ( wall mounted ) complete with casing, motor & mounting frame, ms rain protection cowl, bird screen and all other accessories ( suitable for 415v / 3 phase etc ) . capacity 4, 000 cmh, static 10 mmwc. , etc axial flow exhaust fans10000 cmh ( axial flow exhaust fans ( wall mounted ) complete with casing, motor & mounting frame, ms rain protection cowl, bird screen and all other accessories ( suitable for 415v / 3 phase etc ) . capacity 10, 000 cmh, static 10 mmwc. , etc chain pulley block...

National Security Guard - Haryana

32789129 operation, repair and maintenance of fire fighting equipments for the year 2022 23 ( sh: maintenance on routine basis ) 1 sub head i pumps & motorspreventive maintenance of the fire as per pump list attached. the agency will undertake the maintenance work of the pumps only through the oem or oem authorized dealer. 2 site, model, make, primer mover & qty of pumps 3 old magzine up150 / 45 ( kbl ) engine driven 01 nos up150 / 45 ( kbl ) motor driven 02 nos cphm40 / 26 ( kbl ) motor driven 01 nos 4 niranjan auditoriumdsm80 / 36 ( kbl ) engine driven 01 nosdsm80 / 36 ( kbl ) motor driven 02nosdb32 / 26 ( kbl ) motor driven 01 nosdb50 / 16 ( kbl ) motor driven 02 nos 5 new building dsm100 / 36 ( kbl ) engine driven 01 nosdsm125 / 40 ( kbl ) motor driven 01nosrkb40 / 12l5 ( kbl ) motor driven 01 nos 6 nagrani bk db50 / 16 ( kbl ) motor driven 02 nos 7 total ( pumps ) 15 nos 8 scope of work covered under the preventive maintenece 9 one visit in each three months will be made by an oem ( kbl ) service person with priorintimation. 10 twobreakdown visits included under amc. 11 complete check up of the pump sets as per kbl standards. 12 check free rotation of pumps. 13 check tightness of casing bolts, foundation bolts, and grease ms fasteners. 14 oil levels, grease in bearings, condition of bearing to be checked and replenished if required ( spare shall be provided by deptt ) 15 vibration, noise, bearing temperature, voltage, speed and pressure to be measured and recorded. 16 alignment of pump set to be checked and in case if required rectification to be carried out and readings to be recorded. 17 coupling bushes, pins, rubber parts to be checked and to be replaced if required. ( spare shall be provided by deptt ) 18 mechanical seal condition to be checked and suitable recommendations to be made. 19 service report will be generated afterevery visit recording data anddetails of above checks. 20 training will be provided to site operators to obtain optimum output & lifeof equipment. 21 overhaulingof the following pump including dismentaling, machining , oiling , greasing , assembling & installation at site includingloading and unloading, to and fro transportation ofpump from nsg campus manesar to the workshop. the work will be done through the oem or oem authorized dealer of the pumps, and the repair work will be given a three month warranty by the oem / authorized dealer. model & make. 22 up150 / 45 or dsm80 / 36 or rkb40 / 12l5.kbl make 23 cphm40 / 26.kbl make 24 db32 / 26 or db50 / 16.kbl make 25 dsm100 / 36 or dsm125 / 40.kbl make 26 replacement of the following spare parts of the existing kbl pump up150 / 45 kirloskar make main fire pump driven by electric motor 90kw / 120hp capacitywith a new one if found defective, including testing, complete as required, including credit for old scrap material which will be retained by the contractor etc., complete as required. thework of the pumps will be done only through the oem or oem authorized dealer. 27 mechanical seal 28 mechanical seal plate 29 sleeve moc bronze ( 17458cq001012 ) 30 set of gasket moc non asbestos 31 o ring moc natural rubber 32 ball bearing 2877 moc ss ( x630900400000 ) 33 wear ring moc bronze ( 1712021991012 ) 34 rewinding of ( from 12.5 hp up to 120 h.p. three phase capacity ) electrical motors including all necessary material and of the same characteristics as original with required size of super enameled copper wire and f class insulation material including dismantling, removing of burnt wires, cleaning of slots, varnishing, assembling, greasing, testing etc. complete as required including credit for old scrap material which will be retained by the contractor etc., complete as required. thework of rewinding of motors will be done only through the oem or oem authorized dealer. 35 sub head iifire alarm system sitc / replacement of addressable manual call point complete as required through authorised dealer or oem ( compatible with est3 or equivalent addressable system ) make edward / apollo / siemens / notifier or equivalent 36 sitc / of addressable photo thermal detector complete with mounting base complete as read through authorised dealer or oem ( compatible with est3 or equivalent addressable system ) make edward / apollo / siemens / notifier or equivalent 37 sitc of intelligent addressable programmable sounder complete as required through authorised dealer or oem ( compatible with est3 or equivlent addressable system ) make edward / apollo / siemens / notifier or equivalent 38 sitc of addressable fire control module complete as requiredthrough authorised dealer or oem ( compatible with est3 or equivlent addressable system ) make edward / apollo / siemens / notifier or equivqlent 39 providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinkler of rating 68 degree centigrade with required accessories ( pendant / upright sprinkler ) 40 sitc of horn cum strobe complete as read through authorised dealer or oem . ( compatible with est3 or equivalent addressable system ) make edward / apollo / siemens / notifier or equivalent 41 sitc of wall speaker 1.5 / 3 / 6 w metal box ceiling / wall speaker complete etc. as required make honeywell / bosch / ahuja or equivalent 42 dismantling , cleaning & re fixing intelligence detector , hooter , mcp & riincluding checking, testing and connection etc. as required. 43 supply installation testing commissioning of smps device compatible with two loop firepanel make est3 or equivalent as per direction of engg in charge . 44 servicing , commissioning and reprogramming of existed addressable fire alarm panelcompatible with est3 etc. complete as required. 45 sitc of protective cover locked with plastic tie / metallic wire suitable for addressable manual call pointincluding dismantling & re fixing mcp with necessary arrangements as per direction of engineer in charge make hensel kg9001 / honeywell or equivalent as approved by engg in charge . 46 sub head iii pipes & assecories supplying, fixing, testing & commissioning of double flanged sluice valve of rating pn 1.6 with non rising spindle, bronze / gun metal seat, isi marked complete with nuts, bolts, washers, gaskets and conforming to is 780 of following sizes as required :300mm 47 dismantling and reinstalling the existing 150 mm non return valve in horizontal alignment in the fbc pipeline, as well as providingadditional quantity of 150 mm c class heavy duty ms pipeconforming to is 3589 / is 1239, including welding, fittings such as elbows, flanges, nuts, bolts, gaskets, etc., whichever are required to complete the work, painting with two or more coats of synthetic enamel paint on the pipe of the required shade, testing and commissioning, etc., as required. 48 providing, installation, testing & commissioning of water curtain nozzle 15 / 20 mm dia nickel chrome plated brass, bspt, k factor as per design consideration complete as required 49 providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 3589 / is 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall / ceiling or on pipe with suitable clamp / support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia 50 supplying and fixing single headed external yard hydrant valve with 1 no. 63 mm diainstantaneous fm gunmetal / stainless steel coupling and cast iron wheel, isi marked, conforming to is 5290 ( type a ) with blank gunmetal / stainless steel cap and chain as required 51 single headed gunmetal 52 supplying, fixing, testing and commissioning of butterflyvalve of pn 1.6 rating with bronze / gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required : 53 80mm 54 100mm 55 150mm 56 structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 57 supplying & replacement of weather proof hose cabinet suitable for external hydrant / fbic fabricated out of 2 mm thick ms sheet with 6 mm thick glazed glass door in front having locking arrangement having provision for 02 nos rrl hose pipes & 01 nos nozzlemounted on wall or raise brick platform & duly painted with po redexternally & white internally with synthetic enamelled paint , sign writingetc. complete in all respect as required at site& having min dimension 900mm x 600mm x 500mm deep . 58 supplying and fixing 63 mm dia, 15 m long rrl hose pipe with 63 mm dia male and female couplings duly bound with gi wire, rivets etc. conforming to is 636 ( type a ) as required : gunmetal make newage / safex / safegaurd / essel / lifegaurd 59 providing & fixing of pressure switch in m.s. pipe line including connection etc. as required. make denfoss / indfos / sitzer 60 providing & fixing flow switch in following sizes m.s. pipe including connection etc. as required. 150 mm diamakedenfoss / indfos / sitzer 61 supplying and fixing undermentioned item in existingdrum & bracket arrangementcomplete connection etc. asrequired 62 water hose thermoplastic ( textile reinforced ) type 2 as per is: 12585size 20 mm nominal internal dia x 30 mtr length including credit for old scrap material which will be retained by the contractor etc., complete as required. 63 20 mm nominal internal dia gun metal globe valve with nozzle on existing water hose with ss clampincluding credit for existing gun metal globe valve & nozzle material which will be retained by the contractor etc., complete as required. 64 hose reel drum with brackets conforming to is 884 ms construction spray painted in post office red including credit for exisitng reel drumwhich will be retained by the contractor. etc. complete as required. 65 fabrication supply installation testing commissioning mscabinet made of 1.2mm thick ms sheet with4 mm thick transparent acrylic sheet double leaf door on the front including necessary locking arrangement including mounting on wall, suitable to accommodate different typefire extinguisher duly painted with post office red externally and white internally with synthetic enamel paint without back cover including dismantling & refixing the existing fire extinguisher completely required as per direction of engineer in charge ( min depth 250mm ) as per site condition for a fire extinguisher as required. 66 providing & fixing msclamp suitable for existing fire extinguisher ( dry powder 06 kg / water spray 09 ltr / co2 type 4.5 kg ) 67 sub head iv e &m workearthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. 68 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 69 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 70 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. 71 providing and fixing 25 mm x 5 mm copper strip in 40 mm dia g.i. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re filling etc. as required 72 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required 73 sitc of wall fan 400 mm sweep oscillating type having aerodynamically designed & balanced blade complete with all accessories such as front cover, mounting accessories i / c connection etc. as reqd.havells dzire 400 or equivalent in crompton / usha 74 wiring for submain wiring along with earth wire with following size of frls pvc insulated copper conductor single core cable in surface / recess medium class pvc conduit as reqd 75 2x1.5 sqmm + 1x1.5 sqmm earth wire 76 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5 / 6 a modular socket outlet and 5 / 6 a modular switch, connections etc. as required. 77 providing and fixing following switch gears, meters and accessoriesin existing cubicle panel / starter board including drilling holes in cubicle panel, making connections, etc. as required including credit for old scrap material which will be retained by the contractor etc., complete as required. 78 3pole, 415v , power contactor ac3 rating 18 a 79 3pole, 415v , power contactor ac3 rating 25a 80 3pole, 415v , power contactor ac3 rating 32a 81 3pole, 415v , power contactor ac3 rating 70a 82 3pole, 415v , power contactor ac3 rating 110 a 83 overload thermal relay mn2 l&t 9 15a 84 overload thermal relay mn2 l&t 14 23a 85 overload thermal relay mn5 l&t 66 110a 86 add on block 2no+2nc 87 add on block 1no+1nc 88 sub head v fire fightingequipmentssupply, installation, testing and commissioning of ul listed abc map 90% ( mono ammonium phosphate ) automatic ceiling mounted fire extinguisher for oil charged transformer rooms, capacity 10 kg, applicable fire classes a, b & c, ugts pressure gauge, brass forged sprinkler valves with nozzle and equipped with pressure gauge, external coating pure polyester and internal epoxy polyester powder coated, heat sensitive glass bulb of 68°c. make : firemech / ceasefire / minimax / kanex 89 providing and fixing dry powder ( stored pressure ) type portable fire extinguisher of following capacity with mono ammonium phosphate powder 90 % applicable to fire class a, b, c controllable discharge mechanism with epdm hose and nozzle, ugts pressure gauge, deep drawm with mig welding technology , external pure polyester & internal epoxy polyester powder coated , brass forged valves with safety pin of ss material and welding procedure approved by tpi rating as per 15683 and isi mark with suitable fixing bracket ( ms ) etc. as reqd .make ceasefire / minimax / kanex 90 6 kg powder stored pressure type 91 providing and fixing co2 type ( high pressure ) type portablefire extinguisher of following capacity with co2 gas foo fire class b & c electrical discharge controlmechanism fitted with high pressure steel braided discharge nozzle for dispersed discharge of co2 enamel spray painting powder coated handle , hot spinning seamless isi marked rating as per is 15683 with suitable fixing bracket ( ms ) etc. complete as reqd make ceasefire / minimax / kanex 92 4.5 kg co2 portable fire extinguisher type 93 sub headvi miscellaneous worksitcdiesel engine manual start ( air cooled ) driven make kirloskar taf1 / greeves / field marshal ( with std manual starting ) or equivalent flexiblly coupled with self priming pump kirloskar sp3l or equivalent in crompton / wilo , suction 80mm delivery 80mm mounted on movable trolley fabricated out of c channel complete with solid wheel with movable handle arrnagement & side open canopy of ms sheet. [ warranty 01 year ] 94 supplying, installation, testing & commissioning of 600 kva, 50 hz, servo motor operated line voltage corrector, copper wound, indoor, continuous duty, three phase, suitable for 3 phase unbalanced / balanced input voltage and unbalanced / balanced load conditions, which shall comprise three nos. fully ic controlled sensing circuits microprocessor based, with built in filters to improve the output wave to be pure sinusoidal and control each phase individually. conforming to is 9815:1994 with input voltage 300 460v output 415 ( as set output voltage ) , + 1%, naturally oil cooledwith first filling of transformer oiland necessary bypass arrangements, ms tank enclosure mounted on wheels, withdigital display having facilities to show fault indication, manual / auto indication, manual / auto selection switch, output voltage increase / decrease switch, input / output voltage indication, load current indication, including dismantling and credit for the existingkva stabilizer with transformer oil. the stabiliser should be guaranteed for 12 months from commissioning for any manufacturing defects. in the event of any failure within the above period, replacements or rectification of parts shall be free of cost. the quoted rate should include credit for existing600 kva stabilizer with transformer oil which will be retained by the contractor. ( make vinitec electronic laboratory / precision control instruments / selvon instruments pvt. ltd / automatic electric ( ae ) ) / purevolt ) 95 sitc oflead acid battery 150ah, 12v including the dismantling of existing battery, including credit for existing unserviceable battery of the same rating which will be retained by the contractor etc., complete as required. [ warranty 36month ] make exide xp1500 or equivalent in amaron & luminuous . 96 sitc of 7ah, 12 v, vrla maintenance free battery including the dismantling of existing battery, including credit for existing unserviceable battery of the same rating which will be retained by the contractor etc., complete as required. [ warranty 36month ] make exide12bv7b or equivalent in amaron & luminuous . 97 supplying & fixing pvc suction hose pipe isi marked size 75 / 80mm ( make texmo code a0695 or equivalent 98 providing & fixing cast ironfoot valve size 80 mm to end of pvc hose suction pipe etc. complete as required ( make kirloskar / sant / cri / kartar ) ...

Haryana Dairy Development Cooperative Federation Limited - Haryana

31967246 automation & expansion of existing refrigeration plant 1 high stage compressor for cold store kirloskar / fric or equivalent reputed make. 2 cyclone type oil separator model osw 150 40 flanged connections with companion flanges and oil drain valve 3 abb / siemens make 40 hp, 4 pole, ie2, ip 55, class f insulation, ambient 50°c, imb3 mount, tefc sq. cage induction motor suitable for electric supply of 3ph x 415v x 50hz, ac supply with slide rails for compressor. 4 l&t / equiv make star delta starter for the above motors. 5 alfa laval / equiv. make semi welded phe type water cooled ammonia condenser. 6 advance / equiv. make cooling tower for circulation of water through phe condenser. 7 lubi / equiv. make centrifugal pumps suitable capacity of water through chiller against 24 m head. the pump will be complete with coupling, coupling guard, motor, base frame and foundation bolts. 8 ammonia receiver of size 20” dia. x 12’ long constructed with liquid inlet and outlet valves, safety valve, charging valve, drain valve, purge valve, pressure gauge and gauge glass with valves. 9 alfa laval make semi welded phe type water chiller with accumulator. 10 water chiller controls liquid line solenoid valve liquid level controller digital temp. indicator chilled flow switch bprv 11 ms ‘c’ class refrigerant pipes, pipe fittings and ammonia valves to interconnect above equipment in the system comprising of suction, discharge, liquid and oil lines as per pid and based on compact plant layout. 12 g.i ‘b’ class pipes, pipefitting and valves for condenser make up water, cylinder head cooling defrost and drain line piping as per pid and based on assumption that condenser shall be placed at a distance have not more than 10 m from the plant room. 13 puf insulation for accumulators / vessel, suction line, liquid lines and wet return lines with fixing material bitumen / cprx compound and aluminum cladding of 26g with in battery limit. 14 structural material for pipe installation and plat form piping support to be fabricated and installed at site with steel channel and steel angle distance between the supports to be approx. 5 meters, with variance depend on the building condition. 15 mcc panel will be cubical type switchboard with bus bar, incoming acb, indicating lamps, push buttons, switches, fuses, voltmeters, voltmeter switch, ammeters, ammeters switch and starter fora ) compressors motor, b ) condenser fan motor & pump, c ) cooling coil fan motor, 16 16. power & control cabling with cable tray for complete refrigeration plant. up to 3 hp copper unarmored cable above 3 hp aluminum armored cable 17 manual gas purger with safety valve for purging non condensable gases from the system. 18 first charge of ammonia gas and lubricant compressor oil. 19 lubi / equiv. make monobloc centrifugal pump set of suitable capacity for compressor jacket cooling. 20 installation, testing & commissioning of the complete refrigeration plant and putting in operation. our scope is as follows: joberection of the equipment as per our layout with proper operation and alignmentconnecting various equipment’s with pipelines, fittings, controls and instrumentspainting of equipment & pipingpressure testing, charging of gas and commissioning of the plant. 21 5 amp 2 way switch ( hsr code no. 23.8.11.2 ) 22 15 amp 1 way switch ( hsr code no. 23.8.11.3 ) 23 5 amp socket ( hsr code no. 23.8.11.4 ) 24 15 amp 6 pin socket ( hsr code no. 23.8.11.5 ) 25 supply and erection of 25mm pvc conduit isi marked ( medium ) recessed in walvceiling etc. including the cost of pvc bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of engineer in charge of work ( hsr code no. 23.7.6.2 ) ...

Ministry Of Petroleum And Natural Gas - Haryana

31907825 bids are invited for copper tube , refrigerant , blower fan assembly , main controller chiller unit, , controller chiller unit , oil heator , water flow switch , out door fan motor , out door motorfan blade total quantity : 1181...

Haryana Dairy Development Cooperative Federation Limited - Haryana

31373008 automation of existing referigeration plant automation of existing referigeration plant , high stage compressor for cold store kirloskar/fric or equivalent reputed make. , cyclone type oil separator model osw 150 40 flanged connections with companion flanges and oil drain valve , abb/ siemens make 40 hp, 4 pole, ie2, ip 55, class f insulation, ambient 50°c, imb3 mount, tefc sq. cage induction motor suitable for electric supply of 3ph x 415v x 50hz, ac supply with slide rails for compressor. , l&t/ equiv make star delta starter for the above motors. , alfa laval / equiv. make semi welded phe type water cooled ammonia condenser. , advance / equiv. make cooling tower for circulation of water through phe condenser. , lubi / equiv. make centrifugal pumps suitable capacity of water through chiller against 24 m head. the pump will be complete with coupling, coupling guard, motor, base frame and foundation bolts. , ammonia receiver of size 20” dia. x 12’ long constructed with liquid inlet and outlet valves, safety valve, charging valve, drain valve, purge valve, pressure gauge and gauge glass with valves. , alfa laval make semi welded phe type water chiller with accumulator. , water chiller controls liquid line solenoid valve liquid level controller digital temp. indicator chilled flow switch bprv , ms ‘c’ class refrigerant pipes, pipe fittings and ammonia valves to interconnect above equipment in the system comprising of suction, discharge, liquid and oil lines as per pid and based on compact plant layout. , g.i ‘b’ class pipes, pipefitting and valves for condenser make up water, cylinder head cooling defrost and drain line piping as per pid and based on assumption that condenser shall be placed at a distance have not more than 10 m from the plant room. , puf insulation for accumulators/vessel, suction line, liquid lines and wet return lines with fixing material bitumen/ cprx compound and aluminum cladding of 26g with in battery limit. , structural material for pipe installation and plat form piping support to be fabricated and installed at site with steel channel and steel angle distance between the supports to be approx. 5 meters, with variance depend on the building condition. , mcc panel will be cubical type switchboard with bus bar, incoming acb, indicating lamps, push buttons, switches, fuses, voltmeters, voltmeter switch, ammeters, ammeters switch and starter fora) compressors motor, b) condenser fan motor & pump, c) cooling coil fan motor, , 16. power & control cabling with cable tray for complete refrigeration plant. up to 3 hp copper unarmored cable above 3 hp aluminum armored cable , manual gas purger with safety valve for purging non condensable gases from the system. , first charge of ammonia gas and lubricant compressor oil. , lubi / equiv. make monobloc centrifugal pump set of suitable capacity for compressor jacket cooling. , installation, testing & commissioning of the complete refrigeration plant and putting in operation. our scope is as follows: job erection of the equipment as per our layout with proper operation and alignment connecting various equipment’s with pipelines, fittings, controls and instruments painting of equipment & piping pressure testing, charging of gas and commissioning of the plant. , 5 amp 2 way switch (hsr code no. 23.8.11.2) , 15 amp 1 way switch (hsr code no. 23.8.11.3) , 5 amp socket (hsr code no. 23.8.11.4) , 15 amp 6 pin socket (hsr code no. 23.8.11.5) , supply and erection of 25mm pvc conduit isi marked (medium) recessed in walvceiling etc. including the cost of pvc bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of engineer in charge of work (hsr code no. 23.7.6.2)...

Military Engineer Services - Haryana

31162227 repair / replacement of reinforced rubber lined ( rrl ) fair house nozzle and flow switch at bldg no p163 at chm mil stn under ge ( u ) chm...

Department Of Heavy Industry - Haryana

30305189 bids are invited for 2811221 contact pressure gauge 100 mm dia4 0 140 bar fb mounting single contact type , 2811224 lubricationpositionindicator , 2811223 oil level guage for tank depth of 300 mm with magnetic proximity switches of 3 nos for high,medium and low level proximity switches with led status indication plug and socket,arrangement and 5 meter cable , 9234901 in line flow control valve (gate valve) 1/2 bsp thread , 2826070 single solenoid valve 2/2 way spring return type mnih 2 1/4 ms (part no.161725)(b) coil msnig 24 dc (part no,123060) (c)socket mssd c (partno.34583) , 2826047 directional control valve dsg 01 2b2 d24 n1 50(24vdc coil) yuken make / equivalent , 2825538 in line non return valve nrz 10lr , 2826027 non return valve hgl 14 , 2811212 pressure gauze bott0m type 5 11 connection,direct mtg. size 63mm thread connection bsp 1/8 pressure gauge 0 100 bar , 2826073 (a) double solinoid valve 5/3 way g1/4 type mfh 5/3 g1/4 b(part no.19787) (b) solenoid coil msfw 24(part no.4534) or sy7320 5dz 02f, solenoid valve 24 v dc, 1/4 bsp, 5/3 center closed (smc make) / equalent , 2826020 single solenoid directional control valvedg4v 3 2a uz b 10 , 7426618 level switchtype: ls 1700 1/8 npt brass stem,n float,p/n:01701, make:gem , 7426712 flow switch 0.5 to 2 lpm suitable for in line mounting with 1/2 bsp thread 24 vdc total quantity : 1...

Indian Oil Corporation Limited - Haryana

28256073 supply of different type of field instruments at nrpl, panipat 2 flp / wp emergency shut down push button switches along with all mounting & other accessories 3 flow switch , thermal type, spherical tip, for 3 in 150# line, including calibration along with all mounting & other accessories 4 flow switch , thermal type, spherical tip, for 8 in 150# line, including calibration along with all mounting & other accessories 5 ir based explosion proof & weather proof ( point type ) hydrocarbon detectors along with all mounting & other accessories. 6 uv / ir flame detector along with all mounting & other accessories 7 multi sensor detectors ( addressable ) along with all mounting & other accessories 8 multisensor detectors with relay output along with all mounting & other accessories 9 response indicators along with all mounting & other accessories 10 hooters along with all mounting & other accessories 11 pressure transmitters with range max ( 1 to 5 kg / cm2 ) with all mounting & other accessories 12 pressure transmitters with range max ( 0 to 20 kg / cm2 ) with all mounting & other accessories 13 pressure transmitters with range max ( 0 to 100 kg / cm2 ) with all mounting & other accessories 14 pressure transmitters with range max ( 0 to 160 kg / cm2 ) with all mounting & other accessories 15 differential pressure transmitter with range max ( 0 to 3 kg / cm2 ) with all mounting & other accessories 16 differential pressure transmitter with range max ( 0 to 1 kg / cm2 ) with all mounting & other accessories 17 pressure switch ( 15.5 to 69 bar ) with all mounting & other accessories 18 temperature transmitter with rtd range max ( 0 to 100 0c ) with all mounting & other accessories 19 temperature transmitter, with surface mounted duplex rtd with weld pad range max ( 0 to 100 0c ) with all mounting & other accessories...

Indian Oil Corporation Limited - Haryana

25480535 arc for supply of analyser spares , list of item ( s ) / work ( s ) as per tender documents , pmprebldkit ( knf ) f48c co anl pn 108002 00 , pump repair kit , p/n 8606 , so2 analyser , capillary , 13 mil l ( b/y ) , p . n . 8919 , capillary o ring part4800 , sox analy , cil , sample and air filter p/n 8630 , uv lamp thermo p/n 8666 , front panel p b board;p/n 100480 00 , processor board for 43i , p/n: 110570 07 , mother board assembly p/n 100533 00 , i/o exp . board part100542 00 , sox analy , , front panel connector board;p/n102340 00 , front panel display p/n 102496 00 , transformer , step down , p/n : 101399 00 , measurement interfaceboard p/n 100862 00 , input board assembly p/n 102273 00 , trigger pack , p/n 8774 , so2 analyser , pressure sensor p/n:101023 00 , flow senser for 43c so2p/n 102055 00 , pcb flash intensity assy . p/n:8884 , pmt , p/n 8868 , so2 analyser , pmt power supply p/n:101024 00 , pmt base assy , p/n100727 00 , thermofisher , pump assy ( w/bumper kit ) , p/n 111553 01 , ac receptacle assembly;p/n 101055 00 , power supply asembly 24 vdc pn 101681 00 , amb temp conector thermist p/n 101688 00 , fan , 24vdc;p/n 100907 00 , o ring , so2 analyser , p/n : 4829 , o ring , so2 analyser , p/n : 4830 , o ring , p/n 4808 , 42 c , nox analyser , o ring , p/n 4821 , 42 c , nox analyser , o ring , p/n 4822 , 42 c , nox analyser , o ring ( pk/5 ) p/n:9212 , pump repair kitfor 42c noxp/n 107751 00 , repair kit nox analyzr knf pump , p/n:9267 , capillary0 . 008in , thermo , 42c , p/n 4119 , capillary 0 . 015in , thermo , 42c , p/n 4127 , dessicant p/n:6998 , interface board for nox p/n:100536 00 , temperature control board;p/n 100856 00 , i/p board , p/n100545 00 , thermofisher , ozonator assembly , p/n 9973 , ozonator tr assy , 42c nox , p/n 101419 00 , flowtransducer ( sample ) p/n 101021 00 , flow switch ( ozone ) ;p/n 101620 00 , photo multiplier tube , p/n: 9367 , base socket ( c series ) p/n:9981 , solenoid valves p/n 101390 00 , cooler assembly , p/n: 9995 . , reaction chamber assembly;p/n 102648 01 , molybdenum cartridge , thermo , pn 9269 , pump vacuum 115v/60hz p/n: 101011 01 , optical filter kit for p/n 6556 , processor board for 42i , p/n: 110570 01 , mirror assembly ( single ) , p/n: 8888 , 43i , inline filter , 2136 . 232 , thermo , pure qtz wool f 48 c coanl p/n 2126 . 081 , grphit ferule10 forc coanl p/n 2049 . 020 , orifice , critical , p/n 2126 . 044 , analyser , glass orifice ( 100ml/min ) , p/n:2126 . 044 , antisizecompoudfor48c coanl p/n 4090 . 003 , dilution assy gold washer p/n 0041 . 337 , silica gel coloumn , p/n n798car1 , charcoal p/n:iea720000001 , charcoal , activated , p/n 4158 , 42c , analyser , scrubber , lime soda , p/n : iea720000004 , dilution air reg , 200l , thermo , p/n 6984 , flowmeter , 2 . 5 lpm , 200l , thermo , p/n 4495 , vacuum gauge , 200l , thermo , p/n 4546 , gauge 0 100 psi , p/n:6963 , dilution probe w/out ext , p/n epm . 303 h...

Indian Oil Corporation Limited - Haryana

21351282 supply of atlas copco compressor elements spare part kitatlas copco compressor elements spare part kit , compressor element spare part kit ( 3 . 7kw 10b ) ( product no . 2902022202 ) , supply of cable water pump 753c 220 / 230v for leyland ecomet , supply of water pump 753c 220 / 230v for fcu , supply of flow switch fuel for fcu , leyland ecomet , supply of flow switch water 753c for fcu , leyland ecomet , lump sum service charges for installation & commissioning above including all expenses e . g . transportation / local transportation , accommodation etc . ) ...

Indian Oil Corporation Limited - Haryana

21243040 supply of atlas copco compressor elements spare part kitatlas copco compressor elements spare part kit , compressor element spare part kit ( 3 . 7kw 10b ) ( product no . 2902022202 ) , supply of cable water pump 753c 220 / 230v for leyland ecomet , supply of water pump 753c 220 / 230v for fcu , supply of flow switch fuel for fcu , leyland ecomet , supply of flow switch water 753c for fcu , leyland ecomet , lump sum service charges for installation & commissioning above including all expenses e . g . transportation / local transportation , accommodation etc . ) ...

Department Of Irrigation - Haryana

16015398 rate contract for two years extendable for purchase of consumables for use in anaesthesiology deptt pgims rohtak 69. disposable single line pressure transducer 70. single use, arterial cannula, medical grade teflon, with flow switch for arterial cannulation gauge 20, gauge 22. 71. single use, arterial cannula, medical grade teflon, without flow switch for arterial cannulation gauge 20 , gauge 22 72. arterial canula, polyethylene material, disposable, with guide wire,seldinger type, 20g, lenth 8cm, radioopaque 73. arterial canula, polyurathane material, disposable, with guide wire,seldinger type, 22g, lenth 6 cm, radioopaque 74. co2 sample line for monitoring of agent gas monitor and co2 with standard connectors for ett elbow and to be used/ compatible with philips mp 50 patient monitor 75. nasal prongs 76. electrodes for (bispectral index) bis, disposable of good standard compatible with aspect monitoring system. 77. water proof transparent dressing imported with label of sizes 8x7 with a slit for cannula fixation. 78. disposable oxygen delivery mask for oxygen therapy to patients, transparent made of medical grade pvc, with diffuser, should be able to deliver fio2 upto 90% with flow upto 15 litre,of o2. adult & kids 79. flesh coloured elastic adhensive bandage with porous adhesive with fast edges, 10 cm x stretched length 4/6 metre. 80. co axial patient breathing circuit with apl valve fixed with rebreathing bag at machine end, with adaptor for attachment with machine length 1.6 meter, according to international standards, 2 liter reservoir bag.with extra bag. 81. co axial patient breathing circuit, long, with apl valve fixed with rebreathing bag at machine end, with adaptor for attachment with machine length 2.4 meter, according to international standards with extra reservoir bag.. 82. reservoir bag for patient breathing circuit, international standard, medical grade rubber, latex free, non sticky inner walls, capacity 2 lit, 1 lit and 50...

Indian Oil Corporation Limited - Haryana

5937767 miscellaneous instrumentation jobs cable laying on trays/ structures, cable glanding & termination with single compression brass glands,cable glanding & termination with double compression brass glands, letter writing for alpha numeric tagging ( with synthetic enamel), transportation of gas cylinders, fixing of pressure gauge / vacuum gauge(standard), removal of pressure gauge / vacuum gauge(standard), fixing of pressure transmitter / dp transmitter / pressure switch (standard), removal of pressure transmitter / dp transmitter / pressure switch (standard), fixing of pressure gauge / vacuum gauge / draught gauge (remote seal), fixing of pressure transmitter / dp transmitter / pressure switch (remote seal), removal of pressure transmitter / dp transmitter / pressure switch (remote seal), cleaning & flushing of transmitterimpulse line, dechoking of transmitter impulse line, fixing of pitot tube/annubar/target type flow transmitter / vortex / turbine flow meter, removal of pitot tube / annubar / target type flow transmitter /vortex / turbine flowmeter, fixing of p.d. meters / mass flow meters, removal of p.d. meters / mass flow meters, hydraulic testing of transmitter manifold & connected impulse line, fixing of external displacer type level trol / gauge glass/level gauge/ level switch / servo / radar type tank level indicator / float & tape type level indicator / flush mounted level transmitter, removal of external displacer type level trol / gauge glass/level gauge/ level switch /servo / radar type tank level indicator / float & tape type level indicator / flush mounted level transmitter, fixing of internal displacer type level trol / level switch, removal of internal displacer type level trol / level switch, cleaning & servicing of level gauge / gauge glass in position, installation/fixing of temperature transmitter, installation / fixing of temperature gauge / temp. switch / thermocouple / rtd with out thermowell, removal of temp. gauge / temp. switch / thermocouple / rtd with out thermowell, fixing of thermowell, fixing of i/p, p/i, e/i, f/i convertor, removal of i/p, p/i, e/i, f/i convertor, fixing of air filter regulator, removal of air filter regulator, servicing of air filter regulator, installation din rail mounted instruments, relay & other similar type of panel mounted devices inside a panel, panel wiring, termination of wire, fixing of din rail mounted, removal of din rail mounted, removal of panel wiring, removal & fixing back of false flooring tiles, installation of solenoid valve / output meter / limit switch, fixing of solenoid valve / outputmeter / flow switch / limit switch, removal of solenoid valves, out put meter, flow switch & limit switches etc., fixing of misc. instruments in panel, fixing of junction box, removal of junction box, dismantling & servicing of all instruments & accessories of rov....