Department Of Atomic Energy - Haryana

33954668 bids are invited for addressable intelligent smoke detector with base , addressable intelligent heat detector , manual call point mcp , strobe cum sounder , control module , fire alarm control panel , fire alarm repeater panel , response or remote indicator , 12 core 6 pairs one point five sq mm frls cooper armoured cable , 2 core one point five sq mm frls cooper armoured cable , 20mm flexible gi conduit ,20 terminal junction box , pvc mounting box for detector ,test devices and detector removal or installation tool kit ,aerosol gas cans , addressable intelligent fault isolator ,installation testing and commissioning of addressable firealarm system total quantity : 2805...

Military Engineer Services - Haryana

33190218 provision of office armoury for dsc and naval armoury and magazine at nts gurgaon under ge ( af ) gurgaon 1 sch a section i & viii under srl no.2.0 to 9.0 these schedules are pre priced by mes. details of section i to vii are given in tender documents 2 lump sum price worked out by the contractor for single storey building of office and armoury for dsc and naval armoury and magazines at nts gurugaon with permanent specifications and as per drawing details as listed in sch a sec i building works ( refer prepriced shedule attached seperately ) 3 lump sum price worked out by the contractor for septic tank for 25 users as listed in sch a section i building works ( refer prepriced shedule attached seperately ) 4 lump sum price worked out by the contractor for soak well of 1.80 m dia x 3.0 mtr deep as listed in sch a section ibuilding works ( refer prepriced shedule attached seperately ) 5 lump sum price worked out by the contractor for site clearance as listed in sch a section ii ( refer prepriced shedule attached seperately ) 6 lump sum price worked out by the contractor for as listed in sch a sewage disposal as listed in sch a section iii ( refer prepriced shedule attached seperately ) 7 lump sum price worked out by the contractor for internal water supplyas listed in sch a section iv ( refer prepriced shedule attached seperately ) 8 lump sum price worked out by the contractor for external water suply as listed in sch a section v ( refer prepriced shedule attached seperately ) 9 lump sum price worked out by the contractor for internal electrification as listed in sch a section vi ( refer prepriced shedule attached seperately ) 10 lump sum price worked out by the contractor for external electric supply as listed in sch a section vii ( refer prepriced shedule attached seperately ) 11 lump sum price worked out by the contractor for cooling appliances as listed in sch a section viii ( refer prepriced shedule attached seperately ) 12 miscellaneous items under sch a section ix are not prepriced by mes and item rate to be quoted by contractor for each item. 13 supply and fix indor type water cooler electric driven ( single phase ) , 230 v + 10%, 50 hz, having approx storage capacity of 80 litre and nominal cooling capacity of 60 litres per hour with inbuilt uv and ro system, cfc free refrigerent ( r134a ) incl all accessories complete all specified and directed. 14 supply and fix voltage stabilizer suitable for water cooler for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of ± 11% and capacity of size 2 kva complete all specified and directed. 15 material and labour for cutting gi pipe line of size up to 15 mm to provide new connection by inserting new tee, branches connecting to water cooler complete all as specified. 16 m&l for cutting existing ci or steel tubing of any size for alternation or additions and screwing complete all as specified and directed. 17 m&l for boring of holes under road, pavement, hard standing by trenchless technology using ultra sound techniques and necessary machines including 150 mm hdpe pipe suitable for 0.4 mpa working pressure complete all as specified and directed. 18 s & f vtpn distribution board 8 way, double door, sheet metal enclosure, 415v, 200amps rating and earth bus and din rail including 01 no mccb, 3 pole, 415 volts, 50 hz, 125 amp, 16 ka breaking capacity as incomer compelte all as specified and directed. 19 s&f in chromium plated brass health faucet of 15mm bore pipe with 1.5 mtr. flexible pipe screwed for iron pipe fancy type long body complete all as specified and as directed. complete all as specifiedand directed. 20 s&f modular metal flush box 12 module complete all as specifiedand directed. 21 s&f modular cover plate with frame 12 module complete all as specifiedand directed. 22 supply and installation fire alarm panel complete all as specifiedand directed. 23 s&f smoke / heat detector, mfad, complete all as specifiedand directed. 24 s&f mcp complete all as specifiedand directed. 25 s&f hooter, complete all as specifiedand directed. 26 s&f ups 1 kva complete all as specifiedand directed. 27 s&f conduit 25mmcomplete all as specifiedand directed. 28 s&f 2 core, 1.5 sqmm frls armoured shielded complete all as specifiedand directed. 29 supply, installation of system including testing complete all as specifiedand directed....

Department Of Atomic Energy - Haryana

31010236 bids are invited for supply of addressable intelligent photo thermal detector with base (q3) , supply of addressable intelligent heat detector with base (q3) , supply of response indicator (q3) , supply of manual call point (q3) , supply of sounder cum strobe (q3) , supply of intelligent addressable relay/control module (q3) , supply of addressable intelligent fire alarm panel (q3) , supply of fire alarm repeater panel (q3) , supply of 2 core 1.5 sq. mm. frls cu. unarmoured cable including all fixing arrangement (q3) , supply of 2 core 1.5 sq. mm. frls cu. armoured cable including all fixingarrangement (q3) , supply of nickel plated doublecompression brass cable gland (q3) , supply of 25 mm rigidgi conduit including all accessories (q3) , supply of 20 mmflexible gi conduit (q3) , supply of 4 way gi mounting boxfor detector (q3) , supply of test devices and detectorremoval/ installation tool kit (q3) , supply of aerosol gascans 250 ml (q3) , installation, testing and commissioningof addressable fire alarm system as complete (q3) total quantity : 3127...

Department Of Atomic Energy - Haryana

26965856 bids are invited forsupply of addressable intelligent photo thermal detector with base as per specification. , supply of addressable intelligent heat detector with base as per specification , supply of response indicator as per specification. , supply of manual call point as per specification. , supply of sounder cum strobe as per specification. , supply of intelligent addressable relay/control module as per specification , supply of addressable intelligent fire alarm control panel as per specification , supply of fire alarm repeater panel as per specification , supply of 2 core 1.5 sq. mm. frls cu. unarmored cable as per specification. , supply of 2 core 1.5 sq. mm. frls cu. armoured cable as per specification. ,supply of nickel plated double compression brass cablegland as per specification , supply of 25 mm gi conduitincluding all accessories as per specification. , supply of 20mm flexible gi conduit , supply of 4 way gi/steel mountingbox suitable for detector base as per specification , supplyof test devices and detector removal/ installation tool kitas per specification , supply of aerosol test gas can 250ml(for testing smoke detector) , installation, testing andcommissioning of addressable fire alarm system ascomplete as per specific total quantity : 3127...

Haryana State Cooperative Supply And Marketing Federation Ltd - Haryana

24738155 annual maintenance contract for operation and maintenance of complete fire detection , protection carbon dioxide and wet riser system installed at hafed corporate office , sector 5 , panchkula , operation ( l 1 shall be declared strictly on the basis of the rates quoted for item no . 1 . ) , provision of 1 fireman per shift for 3 shifts of 8 hours each for operation and maintenance of complete fire detection , protection carbon dia oxide and wet riser system installed at hafed corporate office , sector 5 , panchkula . note: bidders should not quote their rates less than rs . 7 , 95 , 000/ , provision ( if required ) maintenance , supply & erection of material / components to replace during the contract period valid to minimum 12 months ( i ) smoke detector , ( ii ) heat detector ( rate of rise type ) , ( iii ) hooter , ( iv ) amplifier , ( v ) speaker , ( vi ) hose pipe 15m , ( vii ) nozzle , ( viii ) discharge nozzle , ( ix ) wet riser nozzle , ( x ) filling of abc map dry powder charge 6 kg . ...

National Hydroelectric Power Corporation Limited - Haryana

24697533 non comprehensive annual maintenance contract for one year for repair and maintenance of fire alarm system installed at neer shakti sadan , nhpc office complex , sector 33 , faridabad , non comprehensive amc of fire alarm system installed at neer shakti sadan office complex , faridabad as per scope of work . first year , optical smoke detector with inbuilt isolator make notifier , model nfxi opt iv , adderessable bases for optical smoke/ multi criteria/ fixed cum rate of rise heat detector make notifier , model b501ap/iv , multi criteria detector with inbuilt isolator make notifier , model nfxi smt1/iv , fixed cum rate of rise heat detector with inbuilt isolatormake notifier , model nfxi/tdif , conventional beam detector with relay module and fault isolatormake notifier , model 6500r , control relay modulemake notifier , model m701 240 , monitor module with inbuilt fault isolatormake notifier , model m701 , manual call point with inbuilt isolatormake notifier , model m701kaci fg , wall sounder/ strobe/ beacon redmake notifier , model nfxi wsf rr , low profile basemake notifier , model lpbw...

Military Engineer Services - Haryana

24462347 ge/sra 35 of 2019 2020 as per boq , annual maintenance contract for fire fighting system , fire alarm & fire detection system at atc , complete all as specified and as directed comprising of the following : fire fighting system : ( a ) fire fighting panel 01 no . ( b ) jockey pump 10 hp 01 no . ( c ) electric driven pump 75 hp 01 no . ( d ) diesel engine driven pump 75 hp 01 no . ( e ) fire hydrant landing valve 16 no . ( f ) hose box 10 no . ( g ) branch pipe 10 no . ( h ) hose reel drum 10 no . ( j ) hose 15 metre long 10 no . ( k ) fire hydrant stand post 06 no . ( l ) ci sluice valve 80mm 05 no . ( m ) fire brigade 01 no . ( n ) ci non return valve 100mm 05 no . ( o ) ci foot valve 100mm 03 no . ( p ) ms erw pipe 150mm 185 rm ( q ) ms erw pipe 100mm 209 rm ( r ) ms erw pipe 80mm 95 rm ( s ) gi heavy duty pipe 80mm 12 rm ( t ) gi heavy duty pipe 40mm 190 rm ( u ) gi heavy duty pipe 25mm 160 rm ( v ) sprinkle glass tube type 92 no . ( w ) sprinkle glass tube upright type 59 no . fire detection & alarm system : ( a ) fire alarm control panel four loop 01 no . ( b ) fire alarm control panel two loop 05 no . ( c ) smoke detectors 58 no . ( d ) heat detectors 58 no . ( e ) manual call point 14 no . ( f ) control module 59 no . ( g ) fault/ short circuit isolator 05 no . ( h ) remote response indicator 116 no ( j ) pvc conduit pipe 25mm 850 rm ( k ) copper flexible wire 1660 rm , annual maintenance contract for fire alarm & fire detection system at wsa , complete all as specified and as directed comprising of the following : fire detection & alarm system : ( a ) fire alarm control panel four loop 01 no . ( b ) fire alarm control panel two loop 05 no . ( c ) smoke detectors 58 no . ( d ) heat detectors 58 no . ( e ) manual call point 14 no . ( f ) control module 59 no . ( g ) fault/ short circuit isolator 05 no . ( h ) remote response indicator 116 no . ( j ) pvc conduit pipe 25mm 850 rm ( k ) copper flexible wire 1660 rm , annual maintenance contract for lift of 08 passenger/ 544 kg at atc as per terms and conditions given as follows : ( a ) servicing of lift at regular intervals and as frequently as the company deems necessary based on the age , nature and condition of the elevator and take all reasonable care and maintaining of lift equipment in safe and proper working condition . ( b ) carry out the servicing work as required whenever possible on a day including sundays & holidays and during regular working hours . ( c ) replenish the gear and motor bearing with necessary manufacturer recommended lubricants whenever necessary and all parts of the lift will be checked , cleaned and lubricated to keep them , both mechanically and electrically in perfect working condition . replacement of unserviceable parts will be included in quoted unit rate . ( d ) carry out according to its standards customary annual safety test to examine all safety devices . ( e ) lift amc will be as per terms and conditions of schindler company . ( f ) contractor has to submit amc within 20 days after acceptance of tender . if the contractor fails then necessary recovery will be made as per terms and conditions of the contract . note : contractor is responsible for working and inspection of registration for the year 2019 20 of lift by lift inspector cum executive engineer , electrical inspectorate , haryana hisar is included in quoted unit rate . , annual maintenance contract for lift of 06 passenger/ 408 kg at smc as per terms and conditions given as follows : ( a ) servicing of lift at regular intervals and as frequently as the company deems necessary based on the age , nature and condition of the elevator and take all reasonable care and maintaining of lift equipment in safe and proper working condition . ( b ) carry out the servicing work as required whenever possible on a day including sundays & holidays and during regular working hours . ( c ) replenish the gear and motor bearing with necessary manufacturer recommended lubricants whenever necessary and all parts of the lift will be checked , cleaned and lubricated to keep them , both mechanically and electrically in perfect working condition . replacement of unserviceable parts will be included in quoted unit rate . ( d ) carry out according to its standards customary annual safety test to examine all safety devices . ( e ) lift amc will be as per terms and conditions of johnson company . ( f ) contractor has to submit amc within 20 days after acceptance of tender . if the contractor fails then necessary recovery will be made as per terms and conditions of the contract . note : contractor is responsible for working and inspection of registration for the year 2019 20 of lift by lift inspector cum executive engineer , electrical inspectorate , haryana hisar is included in quoted unit rate . ...

Haryana State Cooperative Supply And Marketing Federation Ltd - Haryana

23421468 annual maintenance contract for operation and maintenance of complete fire detection , protection carbon dioxide and wet riser system installed at hafed corporate office , sector 5 , panchkula , operation , provision of 1 fireman per shift for 3 shifts of 8 hours each for operation and maintenance of complete fire detection , protection carbon dia oxide and wet riser system installed at hafed corporate office , sector 5 , panchkula . note: bidders should not quote their rates less than rs . 7 , 95 , 000/ , provision ( if required ) maintenance , supply & erection of material / components to replace during the contract period valid to minimum 12 months ( i ) smoke detector , ( ii ) heat detector ( rate of rise type ) , ( iii ) hooter , ( iv ) amplifier , ( v ) speaker , ( vi ) hose pipe 15m , ( vii ) nozzle , ( viii ) discharge nozzle , ( ix ) wet riser nozzle , ( x ) filling of abc map dry powder charge 6 kg . ...

Military Engineer Services - Haryana

22238302 annual maintenance contract for fire fighting system , fire alarm & fire detection system at atc , complete all as specified and as directed comprising of the following : fire fighting system : ( a ) fire fighting panel 01 no . ( b ) jockey pump 10 hp 01 no . ( c ) electric driven pump 75 hp 01 no . ( d ) diesel engine driven pump 75 hp 01 no . ( e ) fire hydrant landing valve 16 no . ( f ) hose box 10 no . ( g ) branch pipe 10 no . ( h ) hose reel drum 10 no . ( j ) hose 15 metre long 10 no . ( k ) fire hydrant stand post 06 no . ( l ) ci sluice valve 80mm 05 no . ( m ) fire brigade 01 no . ( n ) ci non return valve 100mm 05 no . ( o ) ci foot valve 100mm 03 no . ( p ) ms erw pipe 150mm 185 rm ( q ) ms erw pipe 100mm 209 rm ( r ) ms erw pipe 80mm 95 rm ( s ) gi heavy duty pipe 80mm 12 rm ( t ) gi heavy duty pipe 40mm 190 rm ( u ) gi heavy duty pipe 25mm 160 rm ( v ) sprinkle glass tube type 92 no . ( w ) sprinkle glass tube upright type 59 no . fire detection & alarm system : ( a ) fire alarm control panel four loop 01 no . ( b ) fire alarm control panel two loop 05 no . ( c ) smoke detectors 58 no . ( d ) heat detectors 58 no . ( e ) manual call point 14 no . ( f ) control module 59 no . ( g ) fault / short circuit isolator 05 no . ( h ) remote response indicator 116 no ( j ) pvc conduit pipe 25mm 850 rm ( k ) copper flexible wire 1660 rm , annual maintenance contract for fire alarm & fire detection system at wsa , complete all as specified and as directed comprising of the following : fire detection & alarm system : ( a ) fire alarm control panel four loop 01 no . ( b ) fire alarm control panel two loop 05 no . ( c ) smoke detectors 58 no . ( d ) heat detectors 58 no . ( e ) manual call point 14 no . ( f ) control module 59 no . ( g ) fault / short circuit isolator 05 no . ( h ) remote response indicator 116 no . ( j ) pvc conduit pipe 25mm 850 rm ( k ) copper flexible wire 1660 rm , annual maintenance contract for lift of 08 passenger / 544 kg at atc as per terms and conditions given as follows : ( a ) servicing of lift at regular intervals and as frequently as the company deems necessary based on the age , nature and condition of the elevator and take all reasonable care and maintaining of lift equipment in safe and proper working condition . ( b ) carry out the servicing work as required whenever possible on a day including sundays & holidays and during regular working hours . ( c ) replenish the gear and motor bearing with necessary manufacturer recommended lubricants whenever necessary and all parts of the lift will be checked , cleaned and lubricated to keep them , both mechanically and electrically in perfect working condition . replacement of unserviceable parts will be included in quoted unit rate . ( d ) carry out according to its standards customary annual safety test to examine all safety devices . ( e ) lift amc will be as per terms and conditions of schindler company . ( f ) contractor has to submit amc within 20 days after acceptance of tender . if the contractor fails then necessary recovery will be made as per terms and conditions of the contract . note : contractor is responsible for working and inspection of registration for the year 2019 20 of lift by lift inspector cum executive engineer , electrical inspectorate , haryana hisar is included in quoted unit rate . , annual maintenance contract for lift of 06 passenger / 408 kg at smc as per terms and conditions given as follows : ( a ) servicing of lift at regular intervals and as frequently as the company deems necessary based on the age , nature and condition of the elevator and take all reasonable care and maintaining of lift equipment in safe and proper working condition . ( b ) carry out the servicing work as required whenever possible on a day including sundays & holidays and during regular working hours . ( c ) replenish the gear and motor bearing with necessary manufacturer recommended lubricants whenever necessary and all parts of the lift will be checked , cleaned and lubricated to keep them , both mechanically and electrically in perfect working condition . replacement of unserviceable parts will be included in quoted unit rate . ( d ) carry out according to its standards customary annual safety test to examine all safety devices . ( e ) lift amc will be as per terms and conditions of johnson company . ( f ) contractor has to submit amc within 20 days after acceptance of tender . if the contractor fails then necessary recovery will be made as per terms and conditions of the contract . note : contractor is responsible for working and inspection of registration for the year 2019 20 of lift by lift inspector cum executive engineer , electrical inspectorate , haryana hisar is included in quoted unit rate ....

Military Engineer Services - Haryana

22015493 annual maintenance contract for fire fighting system , fire alarm & fire detection system at atc , complete all as specified and as directed comprising of the following : fire fighting system : ( a ) fire fighting panel 01 no . ( b ) jockey pump 10 hp 01 no . ( c ) electric driven pump 75 hp 01 no . ( d ) diesel engine driven pump 75 hp 01 no . ( e ) fire hydrant landing valve 16 no . ( f ) hose box 10 no . ( g ) branch pipe 10 no . ( h ) hose reel drum 10 no . ( j ) hose 15 metre long 10 no . ( k ) fire hydrant stand post 06 no . ( l ) ci sluice valve 80mm 05 no . ( m ) fire brigade 01 no . ( n ) ci non return valve 100mm 05 no . ( o ) ci foot valve 100mm 03 no . ( p ) ms erw pipe 150mm 185 rm ( q ) ms erw pipe 100mm 209 rm ( r ) ms erw pipe 80mm 95 rm ( s ) gi heavy duty pipe 80mm 12 rm ( t ) gi heavy duty pipe 40mm 190 rm ( u ) gi heavy duty pipe 25mm 160 rm ( v ) sprinkle glass tube type 92 no . ( w ) sprinkle glass tube upright type 59 no . fire detection & alarm system : ( a ) fire alarm control panel four loop 01 no . ( b ) fire alarm control panel two loop 05 no . ( c ) smoke detectors 58 no . ( d ) heat detectors 58 no . ( e ) manual call point 14 no . ( f ) control module 59 no . ( g ) fault / short circuit isolator 05 no . ( h ) remote response indicator 116 no ( j ) pvc conduit pipe 25mm 850 rm ( k ) copper flexible wire 1660 rm , annual maintenance contract for fire alarm & fire detection system at wsa , complete all as specified and as directed comprising of the following : fire detection & alarm system : ( a ) fire alarm control panel four loop 01 no . ( b ) fire alarm control panel two loop 05 no . ( c ) smoke detectors 58 no . ( d ) heat detectors 58 no . ( e ) manual call point 14 no . ( f ) control module 59 no . ( g ) fault / short circuit isolator 05 no . ( h ) remote response indicator 116 no . ( j ) pvc conduit pipe 25mm 850 rm ( k ) copper flexible wire 1660 rm , annual maintenance contract for lift of 08 passenger / 544 kg at atc as per terms and conditions given as follows : ( a ) servicing of lift at regular intervals and as frequently as the company deems necessary based on the age , nature and condition of the elevator and take all reasonable care and maintaining of lift equipment in safe and proper working condition . ( b ) carry out the servicing work as required whenever possible on a day including sundays & holidays and during regular working hours . ( c ) replenish the gear and motor bearing with necessary manufacturer recommended lubricants whenever necessary and all parts of the lift will be checked , cleaned and lubricated to keep them , both mechanically and electrically in perfect working condition . replacement of unserviceable parts will be included in quoted unit rate . ( d ) carry out according to its standards customary annual safety test to examine all safety devices . ( e ) lift amc will be as per terms and conditions of schindler company . ( f ) contractor has to submit amc within 20 days after acceptance of tender . if the contractor fails then necessary recovery will be made as per terms and conditions of the contract . note : contractor is responsible for working and inspection of registration for the year 2019 20 of lift by lift inspector cum executive engineer , electrical inspectorate , haryana hisar is included in quoted unit rate . , annual maintenance contract for lift of 06 passenger / 408 kg at smc as per terms and conditions given as follows : ( a ) servicing of lift at regular intervals and as frequently as the company deems necessary based on the age , nature and condition of the elevator and take all reasonable care and maintaining of lift equipment in safe and proper working condition . ( b ) carry out the servicing work as required whenever possible on a day including sundays & holidays and during regular working hours . ( c ) replenish the gear and motor bearing with necessary manufacturer recommended lubricants whenever necessary and all parts of the lift will be checked , cleaned and lubricated to keep them , both mechanically and electrically in perfect working condition . replacement of unserviceable parts will be included in quoted unit rate . ( d ) carry out according to its standards customary annual safety test to examine all safety devices . ( e ) lift amc will be as per terms and conditions of johnson company . ( f ) contractor has to submit amc within 20 days after acceptance of tender . if the contractor fails then necessary recovery will be made as per terms and conditions of the contract . note : contractor is responsible for working and inspection of registration for the year 2019 20 of lift by lift inspector cum executive engineer , electrical inspectorate , haryana hisar is included in quoted unit rate ....

Military Engineer Services - Haryana

21369850 annual maintenance contract for fire fighting system , fire alarm & fire detection system at atc , complete all as specified and as directed comprising of the following : fire fighting system : ( a ) fire fighting panel 01 no . ( b ) jockey pump 10 hp 01 no . ( c ) electric driven pump 75 hp 01 no . ( d ) diesel engine driven pump 75 hp 01 no . ( e ) fire hydrant landing valve 16 no . ( f ) hose box 10 no . ( g ) branch pipe 10 no . ( h ) hose reel drum 10 no . ( j ) hose 15 metre long 10 no . ( k ) fire hydrant stand post 06 no . ( l ) ci sluice valve 80mm 05 no . ( m ) fire brigade 01 no . ( n ) ci non return valve 100mm 05 no . ( o ) ci foot valve 100mm 03 no . ( p ) ms erw pipe 150mm 185 rm ( q ) ms erw pipe 100mm 209 rm ( r ) ms erw pipe 80mm 95 rm ( s ) gi heavy duty pipe 80mm 12 rm ( t ) gi heavy duty pipe 40mm 190 rm ( u ) gi heavy duty pipe 25mm 160 rm ( v ) sprinkle glass tube type 92 no . ( w ) sprinkle glass tube upright type 59 no . fire detection & alarm system : ( a ) fire alarm control panel four loop 01 no . ( b ) fire alarm control panel two loop 05 no . ( c ) smoke detectors 58 no . ( d ) heat detectors 58 no . ( e ) manual call point 14 no . ( f ) control module 59 no . ( g ) fault / short circuit isolator 05 no . ( h ) remote response indicator 116 no ( j ) pvc conduit pipe 25mm 850 rm ( k ) copper flexible wire 1660 rm , annual maintenance contract for fire alarm & fire detection system at wsa , complete all as specified and as directed comprising of the following : fire detection & alarm system : ( a ) fire alarm control panel four loop 01 no . ( b ) fire alarm control panel two loop 05 no . ( c ) smoke detectors 58 no . ( d ) heat detectors 58 no . ( e ) manual call point 14 no . ( f ) control module 59 no . ( g ) fault / short circuit isolator 05 no . ( h ) remote response indicator 116 no . ( j ) pvc conduit pipe 25mm 850 rm ( k ) copper flexible wire 1660 rm , annual maintenance contract for lift of 08 passenger / 544 kg at atc as per terms and conditions given as follows : ( a ) servicing of lift at regular intervals and as frequently as the company deems necessary based on the age , nature and condition of the elevator and take all reasonable care and maintaining of lift equipment in safe and proper working condition . ( b ) carry out the servicing work as required whenever possible on a day including sundays & holidays and during regular working hours . ( c ) replenish the gear and motor bearing with necessary manufacturer recommended lubricants whenever necessary and all parts of the lift will be checked , cleaned and lubricated to keep them , both mechanically and electrically in perfect working condition . replacement of unserviceable parts will be included in quoted unit rate . ( d ) carry out according to its standards customary annual safety test to examine all safety devices . ( e ) lift amc will be as per terms and conditions of schindler company . ( f ) contractor has to submit amc within 20 days after acceptance of tender . if the contractor fails then necessary recovery will be made as per terms and conditions of the contract . note : contractor is responsible for working and inspection of registration for the year 2019 20 of lift by lift inspector cum executive engineer , electrical inspectorate , haryana hisar is included in quoted unit rate . , annual maintenance contract for lift of 06 passenger / 408 kg at smc as per terms and conditions given as follows : ( a ) servicing of lift at regular intervals and as frequently as the company deems necessary based on the age , nature and condition of the elevator and take all reasonable care and maintaining of lift equipment in safe and proper working condition . ( b ) carry out the servicing work as required whenever possible on a day including sundays & holidays and during regular working hours . ( c ) replenish the gear and motor bearing with necessary manufacturer recommended lubricants whenever necessary and all parts of the lift will be checked , cleaned and lubricated to keep them , both mechanically and electrically in perfect working condition . replacement of unserviceable parts will be included in quoted unit rate . ( d ) carry out according to its standards customary annual safety test to examine all safety devices . ( e ) lift amc will be as per terms and conditions of johnson company . ( f ) contractor has to submit amc within 20 days after acceptance of tender . if the contractor fails then necessary recovery will be made as per terms and conditions of the contract . note : contractor is responsible for working and inspection of registration for the year 2019 20 of lift by lift inspector cum executive engineer , electrical inspectorate , haryana hisar is included in quoted unit rate ....

Military Engineer Services - Haryana

21185464 annual maintenance contract for fire fighting system , fire alarm & fire detection system at atc , complete all as specified and as directed comprising of the following : fire fighting system : ( a ) fire fighting panel 01 no . ( b ) jockey pump 10 hp 01 no . ( c ) electric driven pump 75 hp 01 no . ( d ) diesel engine driven pump 75 hp 01 no . ( e ) fire hydrant landing valve 16 no . ( f ) hose box 10 no . ( g ) branch pipe 10 no . ( h ) hose reel drum 10 no . ( j ) hose 15 metre long 10 no . ( k ) fire hydrant stand post 06 no . ( l ) ci sluice valve 80mm 05 no . ( m ) fire brigade 01 no . ( n ) ci non return valve 100mm 05 no . ( o ) ci foot valve 100mm 03 no . ( p ) ms erw pipe 150mm 185 rm ( q ) ms erw pipe 100mm 209 rm ( r ) ms erw pipe 80mm 95 rm ( s ) gi heavy duty pipe 80mm 12 rm ( t ) gi heavy duty pipe 40mm 190 rm ( u ) gi heavy duty pipe 25mm 160 rm ( v ) sprinkle glass tube type 92 no . ( w ) sprinkle glass tube upright type 59 no . fire detection & alarm system : ( a ) fire alarm control panel four loop 01 no . ( b ) fire alarm control panel two loop 05 no . ( c ) smoke detectors 58 no . ( d ) heat detectors 58 no . ( e ) manual call point 14 no . ( f ) control module 59 no . ( g ) fault / short circuit isolator 05 no . ( h ) remote response indicator 116 no ( j ) pvc conduit pipe 25mm 850 rm ( k ) copper flexible wire 1660 rm , annual maintenance contract for fire alarm & fire detection system at wsa , complete all as specified and as directed comprising of the following : fire detection & alarm system : ( a ) fire alarm control panel four loop 01 no . ( b ) fire alarm control panel two loop 05 no . ( c ) smoke detectors 58 no . ( d ) heat detectors 58 no . ( e ) manual call point 14 no . ( f ) control module 59 no . ( g ) fault / short circuit isolator 05 no . ( h ) remote response indicator 116 no . ( j ) pvc conduit pipe 25mm 850 rm ( k ) copper flexible wire 1660 rm , annual maintenance contract for lift of 08 passenger / 544 kg at atc as per terms and conditions given as follows : ( a ) servicing of lift at regular intervals and as frequently as the company deems necessary based on the age , nature and condition of the elevator and take all reasonable care and maintaining of lift equipment in safe and proper working condition . ( b ) carry out the servicing work as required whenever possible on a day including sundays & holidays and during regular working hours . ( c ) replenish the gear and motor bearing with necessary manufacturer recommended lubricants whenever necessary and all parts of the lift will be checked , cleaned and lubricated to keep them , both mechanically and electrically in perfect working condition . replacement of unserviceable parts will be included in quoted unit rate . ( d ) carry out according to its standards customary annual safety test to examine all safety devices . ( e ) lift amc will be as per terms and conditions of schindler company . ( f ) contractor has to submit amc within 20 days after acceptance of tender . if the contractor fails then necessary recovery will be made as per terms and conditions of the contract . note : contractor is responsible for working and inspection of registration for the year 2019 20 of lift by lift inspector cum executive engineer , electrical inspectorate , haryana hisar is included in quoted unit rate . , annual maintenance contract for lift of 06 passenger / 408 kg at smc as per terms and conditions given as follows : ( a ) servicing of lift at regular intervals and as frequently as the company deems necessary based on the age , nature and condition of the elevator and take all reasonable care and maintaining of lift equipment in safe and proper working condition . ( b ) carry out the servicing work as required whenever possible on a day including sundays & holidays and during regular working hours . ( c ) replenish the gear and motor bearing with necessary manufacturer recommended lubricants whenever necessary and all parts of the lift will be checked , cleaned and lubricated to keep them , both mechanically and electrically in perfect working condition . replacement of unserviceable parts will be included in quoted unit rate . ( d ) carry out according to its standards customary annual safety test to examine all safety devices . ( e ) lift amc will be as per terms and conditions of johnson company . ( f ) contractor has to submit amc within 20 days after acceptance of tender . if the contractor fails then necessary recovery will be made as per terms and conditions of the contract . note : contractor is responsible for working and inspection of registration for the year 2019 20 of lift by lift inspector cum executive engineer , electrical inspectorate , haryana hisar is included in quoted unit rate ....

Indian Oil Corporation Limited - Haryana

19255792 supply of fenwal make heat detectors to iocl panipat naptha cracker, panipat, haryana, supply of fenwal make heat detectors to iocl panipat naptha cracker...

Engineers India Limited - Haryana

16050158 deluge valve and heat detectors spray nozzle fire fighting, deluge valve and heat detectors spray nozzle fire fighting => limited tender => ( s ) for retender, dates...