Military Engineer Services - Haryana

39457410 repair / maintenance of solar water heating system, electric geysers and other items at af stn palam under ge ( af ) gurgaon no. 1; 2 supply and fixing in replacement of gi pipe, medium grade, isi marked, 15 mm bore including all fittings and fixing arrangements complete all as specified and directed. 3 supply and fixing in replacementgi pipe, medium grade, isi marked, 20 mm bore including all fittings and fixing arrangements complete all as specified and directed. 4 supply and fixing in replacementgi pipe, medium grade, isi marked, 25 mm bore including all fittings and fixing arrangements complete all as specified and directed. 5 supply and fixing in replacementgi pipe, medium grade, isi marked, 32 mm bore including all fittings and fixing arrangements complete all as specified and directed. 6 supply and fixing in replacementgi pipe, medium grade, isi marked, 50 mm bore including all fittings and fixing arrangements complete all as specified and directed. 7 s&f in replacement gun metal, globe or gate valves, with iron wheel head, screwed both ends to iron pipe and fixed to 15 mm bore pipe complete all as specified and directed. 8 s&f in replacement gun metal, globe or gate valves, with iron wheel head, screwed both ends to iron pipe and fixed to 20 mm bore pipe complete all as specified and directed. 9 allas per srl item no 6 here in before but for size25 mm bore ditto . 10 allas per srl item no 6 here in before but for size32 mm bore ditto . 11 allas per srl item no 6 here in before but for size50 mm bore ditto . 12 supply and fixing in replacement of 20 mm ballvalves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by engr in charge. 13 supply and fixing in replacement 25 mm ballvalves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by engr in charge. 14 material & labour for pcc 1:2:4, type b1 ( using 20 mm graded crushed stone aggregate ) for making rectangular cube of size 20x20x45cm for installation of solar collectors and support of hot water tank / hot water pipes etc including frame work and demolition of old pcc blocks complete all as specified and directed. 15 m&l for demolition of cement concrete in any description below or above ground level and removal from site complete all as specified and directed. 16 s&f providing glass wool insulation 100mm thick insulated covered by cladding of aluminium sheet 24 swg on warm gi water line of any size complete all as specified & as directed by engr in charge. 17 servicing of solar water systems bypouring the anti corrosion / anti scaling agentsolutionin the make up tank to clear the water circulated pipes of heat convertors sets upto ten solar panels of capacity 1000 lpd and drain out the solution by opening the nuts and bolts of dead plugs placed at the end of the system andmake the system serviceableas per site requirement complete all as specified and directed by engr in charge. 18 servicing of solar water systems bypouring the anti corrosion / anti scaling agentsolutionin the make up tank to clear the water circulated pipes of heat convertors sets upto five solar panels of capacity 500 lpd and drain out the solution by opening the nuts and bolts of dead plugs placed at the end of the system andmake the system serviceableas per site requirement complete all as specified and directed by engr in charge. 19 servicing of solar water systems bypouring the anti corrosion / anti scaling agentsolutionin the make up tank to clear the water circulated pipes of heat convertors sets upto three solar panels of capacity 300 lpd and drain out the solution by opening the nuts and bolts of dead plugs placed at the end of the system andmake the system serviceableas per site requirement complete all as specified and directed by engr in charge. 20 material & labour for ms framed work, fabricated from structural steel sections including welding, bending, cold or hot, drilling holes for bolts, in any shape or size and as indicated or directed having ms angle of size 40x40x4mm thickness on top for placing the collector panels / water tank / supporting hot water pipes / ladders for approch etcinclusive of two coats of synthetic enamel paint over a coat of red oxide primer and fixing in walls / roof etc complete all as specified and directed by engr in charge.note: cost of taking down / dismantling is deemed to be included in quoted rates by contractor. 21 material & labour for inspection and checking offault in solar water heating system of 1000 lpd and rectify the fault including water supply pipe lines complete all as specefied and as directed by engnr in charge. note: rectification of fault should be done on same working day 22 material & labour for inspection and checking offault in solar water heating system of 500 lpd and rectify the fault including water supply pipe lines complete all as specefied and as directed by engnr in charge. note: rectification of fault should be done on same working day 23 material & labour for inspection and checking offault in solar water heating system of 300 lpd and rectify the fault including water supply pipe lines complete all as specefied and as directed by engnr in charge. note: rectification of fault should be done on same working day 24 material & labour for cleaning of solar panels toughned glass with detergent and after that with coline solution and make the glass completely clean including repairing of minor leakages complete all as specified. note : ( a ) cleaning ofsolar panel glasses should be done once in a month for entiresystems which is installed at 13 brd is consider as one job. ( b ) labour / cleaning material rates for the same shall be included in rate quotedby the contractor ( details of solar water heater systems airmen billet 1000 ltr capacity 02 nos, 500 ltr cap 03 nos, omq map qtr 500 ltr cap 03 nos , smq map qtr 400 ltr cap 04 , smq map qtr 300 ltr cap 04 nos ) 25 cleaning of 1000 ltr capacity pvc solar water tanks forwith bleaching powder / non toxic solution throughly including removal of sand , clay silt, or any other material from inside the tank and making date of cleaning on tankcomplete all as directed. 26 cleaning of 500 ltr capacity pvc solar water tanks forwith bleaching powder / non toxic solution throughly including removal of sand , clay silt, or any other material from inside the tank and making date of cleaning on tankcomplete all as directed. 27 cleaning of 300 ltr capacity pvc solar water tanks forwith bleaching powder / non toxic solution throughly including removal of sand , clay silt, or any other material from inside the tank and making date of cleaning on tankcomplete all as directed. 28 supply and fixing in replacement hose pipe clamps as per existing size up to 32 mm dia pipecomplete all as specified and directed by engr in charge. 29 supply & fixing of nut, m6 ( stainless steel ) as per matching / existing complete all as specified and directed by engr in charge. 30 supply & fixing of bolt, m6 x 25, hex head ( stainless steel ) as per matching / existing complete all as specified and directed by engr in charge. 31 supply & fixing washers, m6 x 25, hex head ( stainless steel ) as per matching / existing complete all as specified and directed by engr in charge. 32 supply & fixing of collector screws ( stainless steel. ) as per matching / existing complete all as specified and directed by engr in charge. 33 supply & fixing in replacement of gasket suitable for solar water heater panels as per matching / existing complete all as specified and directed by engr in charge. 34 supply and fixing in replacement 25 / 32 mm dia hose pipe as per existing material size complete all as specified and directed by engr in charge. 35 m&l for rectification of leakage from gi 15 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 15 mm bore medium grade pipe for stopping the leakage by making welding / replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 rm complete all as specifed and as directed by engineer in charge. 36 m&l for rectification of leakage from gi 20 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 20 mm bore medium grade pipe for stopping the leakage by making welding / replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 rm complete all as specifed and as directed by engineer in charge. 37 m&l for rectification of leakage from gi 25 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 25 mm bore medium grade pipe for stopping the leakage by making welding / replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 rm complete all as specifed and as directed by engineer in charge. 38 m&l for rectification of leakage from gi 32 / 40 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 32 mm bore medium grade pipe for stopping the leakage by making welding / replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 rm complete all as specifed and as directed by engineer in charge. 39 m&l for rectification of leakage from gi 50 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 50 mm bore medium grade pipe for stopping the leakage by making welding / replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 rm complete all as specifed and as directed by engineer in charge. 40 m&l for descaling the heat collector panel ( capacity 100 ltr each ) by descaling pump using commercial grade acid mixed with water in the ratio of 1:10 ( acid : water ) after opening / dismantling the heat collector panel from each other and re fixing the same after complete cleaning including providing new nuts & bolts, gasket packing, worn out brass flange including brazing work , all other required hidden work for complete descaling complete all as specified and as directed by engr in charge. 41 supply and fixing in replacement of old flat plate solar collectors toughned glass as per matching existing type, including all fixing accessories complete all as specified and as directed . 42 supply and fixing in replacement of old flat plate solar collectors frame box, including all fixing accessories complete all as specified and as directed. 43 supply and fixing in replacement of old flat plate solar collectors copper absorber, including all fixing accessories complete all as specified and as directed by engr in charge. 44 supply and fixing in replacement of flat plate solar collectors of size 1992x1090x100 mm complete puff insulated collector accessories complete as per matching / existing all as directed by engg in charge.make :arinna / surya shakti india pvt ltd or equivalent makefrom list of make. 45 supply, installation, testing and commissioningin replacement ofglass lined insulated hot water storage solartank of stainless steel ss 304 ofcapacity 1000 ltrs duly insulated with glass wool, wire mesh, thermacoal including allinlet / outlet connections etconexistingms angle iron / channel support for hot water tank completeall as specified and directed by engr in charge. make :arinna / surya shakti india pvt ltd or equivalent makefrom list of make. note : ( a ) the rate for taking downis deemed to fit in the quoted rate, no extra payment made on this account. ( b ) any damage to the building while installing hot water storage tank should repaired in quoted amount, no extra payment made on this account. 46 supply, installation, testing and commissioningin replacement ofglass lined insulated hot water storage solartank of stainless steel ss 304 ofcapacity 500 ltrs duly insulated with glass wool, wire mesh, thermacoal including allinlet / outlet connections etconexistingms angle iron / channel support for hot water tank completeall as specified and directed by engr in charge. make: arinna / surya shakti india pvt ltd or equivalent isi marked. note : ( a ) the rate for taking downis deemed to fit in the quoted rate, no extra payment made on this account. ( b ) any damage to the building while installing hot water storage tank should repaired in quoted amount, no extra payment made on this account. 47 supply, installation, testing and commissioningin replacement ofglass lined insulated hot water storage solartank of stainless steel ss 304 ofcapacity 300 ltrs duly insulated with glass wool, wire mesh, thermacoal including allinlet / outlet connections etconexistingms angle iron / channel support for hot water tank completeall as specified and directed by engr in charge. make: arinna / surya shakti india pvt ltd or equivalent isi marked. note : ( a ) the rate for taking downis deemed to fit in the quoted rate, no extra payment made on this account. ( b ) any damage to the building while installing hot water storage tank should repaired in quoted amount, no extra payment made on this account. 48 supply and fixing in replacement tripple layer rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) of capacity 1000 ltrs hoisted and fixed in position complete all as specified and as directed by engineer in charge. 49 supply and fixing in replacement tripple layer rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) ( isi marked ) of capacity 500 ltrs hoisted and fixed in position complete all as specified and as directed by engineer in charge. 50 supply and fixing in replacement ofheat proof rubber pvc gasket suitable for 25 lrs geyser as per site requirement and complete all as specified & as directed by engineer in charge. 51 supply and fixing in replacement of heavy duty element holding assembly with provision of safety valve in its inlet pockets for thermostate, drain plug complete all as per site requirement and all as specified & directed by engineer in charge. 52 supply & fix in replacement ofinsulation of 25 ltrs geyser as per existing insulating material in existing quantity for each geyser complete all as specified and as directed by engineer in charge. 53 supply & fix in replacement of fasteners up to 8 inch for fixing of geyser complete all as specified and as directed by engineer in charge. 54 s&f in replacement of metal clad plug 20a 2p+e, 230v ac , complete all as specified and as directed by engr in charge. make: indoasian / anchor / havells 55 s&f in replacement of metal clad socket20a 2p+e, 230v ac , complete all as specified and as directed by engr in charge. make: indoasian / anchor / havells 56 supply and fixing in replacement of3 core flexible copper conductor of size 2.5 sqmm cable 1100v grade complete all as specified and as directed by engineer in charge. 57 supply and fixing in replacement of brass ends wiremesh type stainless steel flexible hotwater connection pipe upto 2.0 feet as per requirement complete all as specified and as directed by engineer in charge. 58 supply and fixing in replacement of auto cutoff system for geyser as per matching existing complete all as specified and as directed by engineer in charge. 59 supply and fixing in replacement of mts thermostate for geyser as per matching existing complete all as specified and as directed by engineer in charge. 60 supply and fixing in replacement of mts rectangle element 1.5 / 2.0 kw for geyser as per matching existing complete all as specified and as directed by engineer in charge. 61 supply and fixing in replacement of mts round element 1.5 / 2.0 kw for geyser as per matching existing complete all as specified and as directed by engineer in charge. 62 supply and fixing in replacement of triangle type heating element 1.5 / 2.0 kw for geyser as per matching existing complete all as specified and as directed by engineer in charge. 63 supply and fixing in replacement of indicating lamps as per the site requirement complete all as specified and as directed by engineer in charge. 64 supply & fix in replacement ofinnertank suitable for 25 lrs capacity geyser as per existing gauge and shape complete all as specified and as directed by engineer in charge. 65 supply & fix in replacement of outer body 18 gauge complete with bottom and top cover as per matching to existing type and size for upto 50 ltrs capacity geyser complete all as specified and as directed by engineer in charge.. 66 supply & fix in replacement of top cover complete as per matching to existing type and size for upto 50 ltrs capacity geyser complete all as specified and as directed by engineer in charge. 67 supply & fix in replacement of bottom cover complete as per matching to existing type and size for upto 50 ltrs capacity geyser complete all as specified and as directed by engineer in charge. 68 supply & fix in replacement of outer ring gi steel of 18 gauge upto 3 inches height for holding of tank in geyser of capacity 25 to 50 ltrs capacity complete all as specified and as directed by engineer in charge. 69 supply & fix in replacement of apparture plate for geyser of capacity 25 to 50 ltrs capacity as per matching to existing complete all as specified and as directed by engineer in charge. 70 supply & fix in replacement of sleeve for protection of wire of geysers complete all as specified and as directed by engineer in charge. 71 s&f in replacement of mcb sp of rating, 20 amps, 240 volt, 10 ka b series complete all as specified and as directed by engineer in charge. 72 supply & fix in replacement of sheet metal enclosurefor220 volts 20 amps with a three pin and earth plug top with socket and one single pole mcb20 amps complete as well as specified and directed. 73 disconnecting carefully water and electric connection from geysers and taking down of storage type water heater of capacity upto 50 ltr, 230 volt for cleaning and descaling of inner tank, heating plate assembly and element with suitable descaling solution properly including welding, soldering / brazing if requiredto arrest the minor leakage and re assembling the complete geyser and refixing in existing position with fixing arrangement including necessary testings complate all as specified and directed. 74 taking down unserviceable any type of submain wiring and m&l for concealed sub main wiring of two run with 04 sqmm single core pvc insulated, frls, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including pvc conduit pipe 25 mm dia medium grade and accessories of suitable size and fixed on concealed surface of wall / ceiling with cutting chases for conduit including one run of 4.0 sqmm single core pvc insulated, frls , flexible multi stranded copper cable as earth continuity conductor in green color all as specified and as directed.note ( a ) two runs of single core cable with one run of earth continuity cable including pvc conduit and its accessories will be measured and paid as one unit. ( b ) make disturbed surface good to wall / floors . 75 taking down unserviceable any type of submain wiring and m&l for sub main wiring of two run with 04 sqmm single core pvc insulated, frls, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including pvc conduit pipeas per site requirement medium grade and accessories of suitable size and fixed on wall / ceiling including one run of 4.0 sqmm single core pvc insulated, frls , flexible copper cable as earth continuity conductor in green color all as specified and as directed. 76 supply and fixing in replacement ofpvc conduit pipe of size of size 20 mm complete all as specified and as directed by engineer in charge. 77 supply and fixing threaded type pvc water tank cover suitable for upto 1000 ltr capacity pvc tank complete all as specified and as directed by engineer in charge. 78 supply and fixing in replacement of 16 amp 3 pin plug complete all as specified and as directed by engineer in charge. make : anchor / cone / roma 79 supply and fixing in replacement of 16 amp 3 / 5pin multi socket complete all as specified and as directed by engineer in charge. 80 supply and fixing in replacement of 16 amp 3 pin switch complete all as specified and as directed by engineer in charge. 81 s&f led driver 15w 240 volt 50hz suitable for existing philips fancy rounded ceilling light type: dn170c led10s 6500 psu wh complete all as specified and as directed by engr in charge. make: philips / syska / c&s or equivalent out of makes specified in list of make. 82 s&f led driver 21 w 240 volt 50hz suitable for existing philips fancy rounded ceilling light type: dn170c led10s 6500 psu wh complete all as specified and as directed by engr in charge. make: philips / syska / c&s or equivalent out of makes specified in list of makes. 83 s&fin replacement of wall red & green lamp fitting with bulb holder & led bulb complete with all accessories complete all as specified and as directed . 84 s&f in replacement of 2x2 surface / ceiling mounted light fitting 40 / 42w ( 10 % variation ) led including white diffuser complete with all connected accessories as per sample complete all as specified and as directed by engr in charge. 85 s&f in replacement ofled driver 38 / 40 w 240 volt 50hz suitable for existing 2×2 rectangular ceilling light complete all as specified and as directed by engr in charge. make: halonix / syska / c&s / or equivalent out of makes specified in list of makes. 86 s&f in replacement of lamp / batten holderfor wall / surface mounted light fitting complete all as specified and as directed by engineer in charge. 87 s&fin replacement of fancy type wall fitting with led bulb of 07w complete with all accessories as per sample complete all as specified and as directed by engineer in charge. 88 s&f in replacement of surface mounted round shaped 7 watt led light fittingincluding white diffuser complete with all connected accessories as per sample complete all as specified and as directed by engineer in charge. 89 supply & fix in replacement of fluorescent tube light fitting flame proof flp wp of t5, 1×28 w including integral reflector made of aluminium alloy lm6, with electronic ballest, bipin holders, connector blocks, etc and all accessories pre wired and including connecting up with twincore twisted flxible copper condector with suitable size complete all as spceified and as directed by engr ni charge. make: philips / bajaj / crompton or makes specified in list of makes. 90 supply and fix in replacement of industrial wall mounted plug socket combined in polycarbonate enclosure suitable for ip44 degree of protection 16 / 20 amps rating 2p+e, complete all as specified and as directed by engineer in charge.make neptune / schneider / havells 91 note: ( i ) the amount of rs 1, 40, 301.00 against schedule of credit on page nos 113 to 114 shall be deducted from the total amount quoted against sch awhile deriving the contract sum for acceptance ( ii ) any material required to be replaced for complaint rectification other than insulation tape, thimbles and as specified in complaint item shall be measured and paid seperately under respective supply only item. ( iii ) the cost of unit rate per item shall also include the cost of stationery required for recording complaint, complaint slips and its reports as directed by engineer in charge. ( iv ) all the complaint registered ( except point wiring / sub main wiring and connected s&f items ) before 0930 hrs of every day shall be rectified on same day upto 1700 hrs. any delay in complaint rectification a penalty shall be recovered @ rs.100 / per complaint per day. ( v ) the items supplied by contractor as supply only shall be taken on charge by deptt. ( vi ) all t&p required to electrician deployed by the contractor for complaint rectification shall be provided by the contractor at his own cost. ( vii ) any disturbed surface during execution of work shall be made good as existing. nothing extra shall be paid in this respect. the quoted rate are deemed to be included the same cost....

Public Health Engineering Department - Haryana

37851789 tender for annual maintenance estimate for pha in haryana bhawan. 1 outsourcing of works/ o & m job work through contractor cleaning of grease chamber and dumping of waste away from the campus including loading and unloading once in a month complete in all respect as per ndmc norms. / mtc of grease chamber / haryana bhawan campus (07/06/2023 to 12/06/2023 i.e 06 days) 2 outsourcing of works/ o & m job work through contractor mtc. of public health amenities i.e gi/ci pipeline and its fittings, jaquar cp fittings, accessories sanitary ware, gt, mh, ic in vip suites, cm suite, committee room ,general toilets and kitchen , monitoring of solar water system. / mtc. of moderate type pha i.e gi/ci pipeline and c/w ,cp fittings / haryana bhawan campus (07/06/2023 to 12/06/2023 i.e 06 days)...

Public Health Engineering Department - Haryana

37759307 tender for a/mtc. estimate for pha in haryana bhawan cleaning of grease chamber and dumping of waste away from the campus including loading and unloading once in a month complete in all respect as per ndmc norms. / mtc of grease chamber / haryana bhawan campus (01/06/23 to 06/06/23 06 days) mtc. of public health amenities i.e gi/ci pipeline and its fittings, jaquar cp fittings, accessories sanitary ware, gt, mh, ic in vip suites, cm suite, committee room ,general toilets and kitchen , monitoring of solar water system. / mtc. of moderate type pha i.e gi/ci pipeline and c/w ,cp fittings / haryana bhawan campus (01/06/2023 to 06/06/2023 06 days)...

Military Engineer Services - Haryana

36277468 provision of otm accn under ge ( af ) gurgaon schedule `a part i ( building works ) is not prepriced by mes and prepriced rates indicates 0.0 under column 6 signified this fact only. 2 construction of single living accn for jcoscomplete all as specified and shown on drawings. 3 construction of single living accn for havs / ors complete all as specified and shown on drawings. 4 construction of cook house and dining hall complete all as specified and shown on drawings. 5 construction of office accn complete all as specified and as shown on drawings. 6 construction of mt shed ( 3 x 2.5 ton and 1 x als ) complete all as specified and as shown on drawings. 7 construction of mt shed ( 2 x gepsy & 1 x motor cycle ) complete all as specified and as shown on drawings. 8 construction of garage for 32 motor cycle complete all as specified and as shown on drawings. 9 construction of garage for 02 gypsy complete all as specified and as shown on drawings. 10 construction of storage accn complete all as specified and as shown on drawings. 11 construction of unit shop complete all as specified and as shown on drawings. 12 note: schedule ‘a’ part iito xii under are prepriced by mes. 13 lump sum price worked out by the contractor for “excavation and earth work” as listed in schedule ‘a’part ii 14 lump sum price worked out by the contractor for “internal electrification as listed in schedule ‘a’part iii 15 lump sum price worked out by the contractor for “internal water supply as listed in schedule ‘a’part iv 16 lump sum price worked out by the contractor for sewage disposal” as listed in schedule ‘a’part v 17 lump sum price worked out by the contractor for “area drainage” as listed in schedule ‘a’part vi 18 lump sum price worked out by the contractor for “road, path and culvert” as listed in schedule ‘a’part vii 19 lump sum price worked out by the contractor for“external water supply ” as listed in schedule ‘a’part viii 20 lump sum price worked out by the contractor for“external electrification ” as listed in schedule ‘a’part ix 21 lump sum price worked out by the contractor for“compound wall & gate ” as listed in schedule ‘a’part x 22 lump sum price worked out by the contractor for“cooling appliances ” as listed in schedule ‘a’part xi 23 lump sum price worked out by the contractor for“heating appliances ” as listed in schedule ‘a’part xii 24 schedule `a part xiii miscb / r & e / m itemsis not prepriced by mes and prepriced rates indicates 0.0 under column 6 signified this fact only. 25 internal electrification 26 s&f led lamp 10 watt, 230 volts retrofit type complete all as specified and directed. 27 s&f energy saving decorative box type batten led tube light fitting 230 volts surface mounted complete with high efficiency pmma diffuser soft glare free light led tube light 20w, blue coloured end caps with all accesseries prewired with three core flexible copper cable 0.50 sqmm pvc insulated sheathed complete all as specified and directed. 28 s&f led sleek mirror light fitting 10 watt surface mounted provided with high output diffuser 2 ft long, 230 volts, complete with all accessories, pre wired including lamp and providing flexible copper wire, three core cable pvc insulated sheathed complete all as specified and directed. 29 s&f led building security light fitting 20 watt having uniformity ratio 0.25, high pressure dia cast aluminium housing, heat resistant toughened glass with frame, ip66 protection complete with lamp & connected items and connection with suitable cable from ceiling rose to light fitting and including gl pipe bracket made out of suitable dia gl pipe medium grade 1.2mtr long bent to shape and fixed on wall with flat iron clamps, nut. bolts washer etc all as specified and directed. 30 s&f led light fitting 36 watt, 600x600mm size, surface mounted provided with high output diffuser, 230 volts complete with all accessories, pre wired including lamp and prewired with three core flexible copper cable 0.50 sqmm pvc insulated sheathed complete all as specified and directed. 31 s&f mcb sp6 to 32 amps, c curve type, 10ka breaking capacity, 240 volts complete all as specified and directed. 32 external water supply 33 m&l for construction of valve pit chamber 90 cmx90cm ( inner dimension ) and 90 cm deep , from the top of ms cover fixed on pcc base, top cover shall be of 3 mm thick ms sheet with locking arrangement of pad lock of 50mm size including brick work with sub classb bricks in cm 1:4 including 15 mm thick plaster in cm 1:4 ( internally and externally ) and necessary earth work in anu type of soil including returning filling in and disposal of surplus oil to a distance n exc 50 mtrs and 150 mm thick pcc 1:4:8 , type d 2 , using 40mm graded stone aggregates as in floor complete all as specified and directed. 34 external electric supply 35 supply, installing, connecting electrically, testing and commissioning factory made cubicle type dust and vermin proof lt panel box of suitable size outdoor type, made out of 3.15 mm thick crca sheet and 50x50x6 mm ( isa 5050 ) ms angle frame with hinged cubicle doors with locking arrangement, duly spray painted comprising of the following accessoriesincoming ( i ) mccb, ac 415 volts, 4 pole, 200 amps current rating, 36 ka rupturing capacity with adjustable ( 70% to 100% ) thermal setting and fixed magnetic setting conforming to is: 13947 11 complete with connections to the bus bars. 01 no. ( ii ) aluminium bus bar strip of rated capacity 300 amps with coloured pvc insulating sleeves, mounted on post insulators, 1100 volt grade. 04 nos. ( iii ) voltmeter 0 500 volts digital type, flush mounting with selector switch 01 set ( iv ) ammeter 0 100 amps digital type, flush mounted, with cts and selector switch. 01 set ( v ) phase indicator lamps, led type 01 set ( ryb ) ( vi ) panel instrument fuses 01 setoutgoings ( i ) mccb 160amp 25ka 4p 415volts 01nos with adjustable thermal magnateic release ( ii ) mccb 32amp 16ka4p 415volts 04nos with adjustable thermal magnateic release 36 supply, installing, connecting electrically, testing and commissioning factory made cubicle type dust and vermin proof lt panel box of suitable size outdoor type, made out of 3.15 mm thick crca sheet and 50x50x6 mm ( isa 5050 ) ms angle frame with hinged cubicle doors with locking arrangement, duly spray painted comprising of the following accessories : incoming ( i ) mccb, ac 415 volts, 4 pole, 160 amps current rating, 25 ka rupturing capacity with adjustable ( 70% to 100% ) thermal setting and fixed magnetic setting conforming to is: 13947 11 complete with connections to the bus bars. 01 no. ii ) aluminium bus bar strip of rated capacity 300 amps with coloured pvc insulating sleeves, mounted on post insulators, 1100 volt grade. 04 nos. iii ) voltmeter 0 500 volts digital type, flush mounting with selector switch. 01 set ( iv ) ammeter 0 100 amps digital type, flush mounted, with cts and selector switch. 01 set ( v ) phase indicator lamps, led type. 01 set ( ryb ) vi ) panel instrument fuses 01 setoutgoings ( i ) mccb 80amp 16ka 4p 415volts 03nos with adjustable thermal magnateic release 37 supply, installing, connecting electrically, testing and commissioning factory made cubicle type dust and vermin proof lt panel box of suitable size outdoor type, made out of 3.15 mm thick crca sheet and 50x50x6 mm ( isa 5050 ) ms angle frame with hinged cubicle doors with locking arrangement, duly spray painted comprising of the following accessories : incoming ( i ) mccb, ac 415 volts, 4 pole, 80 amps current rating, 16 ka rupturing capacity with adjustable ( 70% to 100% ) thermal setting and fixed magnetic setting conforming to is: 13947 11 complete with connections to the bus bars. 01 no. ii ) aluminium bus bar strip of rated capacity 200 amps with coloured pvc insulating sleeves, mounted on post insulators, 1100 volt grade. 04 nos. iii ) voltmeter 0 500 volts digital type, flush mounting with selector switch. 01 set ( iv ) ammeter 0 100 amps digital type, flush mounted, with cts and selector switch. 01 set ( v ) phase indicator lamps, led type. 01 set ( ryb ) vi ) panel instrument fuses 01 setoutgoings ( i ) mccb 63amp 16ka 4p 415volts 01nos with adjustable thermal magnateic release. ( i ) mccb 32amp 16ka 4p 415volts 02nos with adjustable thermal magnateic release 38 note for item no 5.01 & 5.03 : the rate quoted by the contractor shall be deemed to include following provision of platform for the panel with pcc 1:4:8 type d 2 using 40mm graded crushed stone aggregate, 15 cm thick in foundation, brick work in cm 1:6 with sub class b old size bricks, rendering sub class b old size bricks, rendering 15 mm thick in cm 1:6 on exposed surfaces and 100mm thick pcc padding ( 1:3:6 ) type c 1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. the platform shall be at a height of 45 cm above the nearest road level. the platform shall be constructed as per manufacturer drawing and design. 39 m&l for earthing complete with galvanized steel earth plate electrode 600x600x6.0mm thick buried directly in ground ( earth pit not less than 2.25 meters deep below ground level ) with top edge of the plate not less that 1.5 meters below normal ground level connected to galvanized iron strip 25 x 4 mm mm as earthing by means of bolts nuts and washers of galvanized iron including excavation and earth work and disposal of surplus soil including 40 mm gl tubing light grade and necessary fittings for protection of gl strip including laying of charcoal, dust and common slat, pcc 1:2: 4 type b 1 using 20 mm graded aggregate with earth pit with 40 x 40 x 6.0 mm ms angle iron frame rcc cover 40 mm thick ( 1:2: 4 ) type c1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75 mm c / c both way with plastering 15 mm thick cm ( 1:6 ) internally and up to 150 mm below ground level externally . pgi funnel with wire mesh , 20 mm dia medium grade gl pipe for watering complete all as shown on electrical plate no : 03 of ssr part 1 2009 and connected to earth test point including testing completed all specified and directed. ( note: 14 numbers for internal electrification & 8 number for external elecrification ) 40 all as per srl item no.5.05 above but gi earth lead wire 4.00 mm dia earthing for street light poles etc complete all as specified and directed. 41 s&f led security light fitting energy efficient 45 watt high pressure die cast aluminium housing, heat resistant toughened glass with frame, ip 66 protection complete and connection with suitable cable from weather proof street light junction box to light fitting and fixing on gl pipe bracket made out of suitable dia gl pipe medium grade 1.2 mtr long bend to shape and fixed on pole with flat iron clamps, nut, bolts, washer etc all as specified and directed. 42 s&f weather proof street light junction box double door of size 325 x 225 x 150 mm made out of pvc / hdpe fir retardant, non fusing, shock & rust proof, single piece moulded / smc housing and smc cover with hinged door, pole mounting type comprising of al busbar 6amp mcb fixed on pole with ms clamp with necessary nuts, washer, duly painted with two coats of synthetic enamel paint over a red oxide primer on steel surface / clamps and embossing / painting of danger sign of size not less than 10cmx 7.5 cm with letter and conventional skull and bones in signal red colour on front face of street light junction box complete all as directed. 43 s&f automatic timer switch to switches on / off the street lights base on pre set timings current rating 15 amps, 220 volts, 50 hz. the microprocessor based astronomical based timer should also have over voltage protection alongwith suitable power contactor, mcb and support terminals should be enclosed in pole / wall mountable enclosure made of rust proof electric shock proof termite proof and fr grade special moulding compounds confirming to ip 54. the contactor mcb and circuit wiring shall have enough capacity to take load of 5 kw equally distributed over 3 phase complete all as specified and directed. 44 labour only for carrying out horizontal boring below roads / pcc hard standing / drain suitable for 80mm dia gl pipe medium grade all as specified as directed incl inserting gl pipe to a depth upto 1.5m & including hardstanding upto width of 12m complete all as specified and as directed. 45 heating applicances 46 s&f mcb single pole 6 to 32 amps 240 v.10ka, b series complete all as specified and as directed. 47 supply, installation, testing and commissioning of solar water system ( flat plate collector ) based on indirected transfer of heat of capacity 300 lpd with electrical heating back upto 3kw including suitable size angle iron stand for stagging of solar water heater and pcc, hot water and cold water connection, electric connection with all accessories complete all as specified and directed. 48 cooling appliances 49 supply and install desert cooler with isi marked fan and made out of ms sheet 11.6mm thickness electric driven single phase copper wound fan motor and water pump motor having nominal air flow capacity of 5000 cubic meter per hour or nearest higher sire ( without any financial effect ) in steel body.it includes the provision of connect gl tubing 15mm size with pvc connection, gland, ball valve and wire for electric connection copper wire 3 core size 1.5 sqmm appx length 3 mtr in desert cooler complete all as specified and as directed by engineer in charge.note wire for electric connection is deemed to be included in quoted rate but pvc connection, ball valve and gl tubing are separately measured. 50 supply and installed voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 135 v to 280 v with: output voltage stabilized at 230 v with accuracy of ± 2.5% and of capacity 1 kva used for deep freezer / refrigerator complete all as specified and directed. 51 supply and install frost free, double door, isi marked 5 star convertible refrigerator electric driven, single phase of capacity 310 litres or nearest higher capacity ( without any financial affect ) complete all as directed. 52 road, path and culvert 53 m&l for thermoplastic paint on black top surfaces or existing paint surfaces applied hot mixing plant of heating of thermo plastic materials to a standard temp with gas and laying standard thickness of approx 2mm, by using thermo plastic material @ 6.5 kg / sqm, and glass beads @ 250 gms / sqm including cleaning of old surfaces, complete all as specified and directed....

Military Engineer Services - Haryana

34957044 tender for provision of otm accn for ge ( af ) gurgaon schedule `a part i ( building works ) is not prepriced by mes and prepriced rates indicates 0.0 under column 6 signified this fact only. 2 construction of single living accn for jcoscomplete all as specified and shown on drawings. 3 construction of single living accn for havs / ors complete all as specified and shown on drawings. 4 construction of cook house and dining hall complete all as specified and shown on drawings. 5 construction of office accn complete all as specified and as shown on drawings. 6 construction of mt shed ( 3 x 2.5 ton and 1 x als ) complete all as specified and as shown on drawings. 7 construction of mt shed ( 2 x gepsy & 1 x motor cycle ) complete all as specified and as shown on drawings. 8 construction of garage for 32 motor cycle complete all as specified and as shown on drawings. 9 construction of garage for 02 gypsy complete all as specified and as shown on drawings. 10 construction of storage accn complete all as specified and as shown on drawings. 11 construction of unit shop complete all as specified and as shown on drawings. 12 note: schedule ‘a’ part iito xii under are prepriced by mes. 13 lump sum price worked out by the contractor for “excavation and earth work” as listed in schedule ‘a’part ii 14 lump sum price worked out by the contractor for “internal electrification as listed in schedule ‘a’part iii 15 lump sum price worked out by the contractor for “internal water supply as listed in schedule ‘a’part iv 16 lump sum price worked out by the contractor for sewage disposal” as listed in schedule ‘a’part v 17 lump sum price worked out by the contractor for “area drainage” as listed in schedule ‘a’part vi 18 lump sum price worked out by the contractor for “road, path and culvert” as listed in schedule ‘a’part vii 19 lump sum price worked out by the contractor for“external water supply ” as listed in schedule ‘a’part viii 20 lump sum price worked out by the contractor for“external electrification ” as listed in schedule ‘a’part ix 21 lump sum price worked out by the contractor for“compound wall & gate ” as listed in schedule ‘a’part x 22 lump sum price worked out by the contractor for“cooling appliances ” as listed in schedule ‘a’part xi 23 lump sum price worked out by the contractor for“heating appliances ” as listed in schedule ‘a’part xii 24 schedule `a part xiii miscb / r & e / m itemsis not prepriced by mes and prepriced rates indicates 0.0 under column 6 signified this fact only. 25 internal electrification 26 s&f led lamp 10 watt, 230 volts retrofit type complete all as specified and directed. 27 s&f energy saving decorative box type batten led tube light fitting 230 volts surface mounted complete with high efficiency pmma diffuser soft glare free light led tube light 20w, blue coloured end caps with all accesseries prewired with three core flexible copper cable 0.50 sqmm pvc insulated sheathed complete all as specified and directed. 28 s&f led sleek mirror light fitting 10 watt surface mounted provided with high output diffuser 2 ft long, 230 volts, complete with all accessories, pre wired including lamp and providing flexible copper wire, three core cable pvc insulated sheathed complete all as specified and directed. 29 s&f led building security light fitting 20 watt having uniformity ratio 0.25, high pressure dia cast aluminium housing, heat resistant toughened glass with frame, ip66 protection complete with lamp & connected items and connection with suitable cable from ceiling rose to light fitting and including gl pipe bracket made out of suitable dia gl pipe medium grade 1.2mtr long bent to shape and fixed on wall with flat iron clamps, nut. bolts washer etc all as specified and directed. 30 s&f led light fitting 36 watt, 600x600mm size, surface mounted provided with high output diffuser, 230 volts complete with all accessories, pre wired including lamp and prewired with three core flexible copper cable 0.50 sqmm pvc insulated sheathed complete all as specified and directed. 31 s&f mcb sp6 to 32 amps, c curve type, 10ka breaking capacity, 240 volts complete all as specified and directed. 32 external water supply 33 m&l for construction of valve pit chamber 90 cmx90cm ( inner dimension ) and 90 cm deep , from the top of ms cover fixed on pcc base, top cover shall be of 3 mm thick ms sheet with locking arrangement of pad lock of 50mm size including brick work with sub classb bricks in cm 1:4 including 15 mm thick plaster in cm 1:4 ( internally and externally ) and necessary earth work in anu type of soil including returning filling in and disposal of surplus oil to a distance n exc 50 mtrs and 150 mm thick pcc 1:4:8 , type d 2 , using 40mm graded stone aggregates as in floor complete all as specified and directed. 34 external electric supply 35 supply, installing, connecting electrically, testing and commissioning factory made cubicle type dust and vermin proof lt panel box of suitable size outdoor type, made out of 3.15 mm thick crca sheet and 50x50x6 mm ( isa 5050 ) ms angle frame with hinged cubicle doors with locking arrangement, duly spray painted comprising of the following accessoriesincoming ( i ) mccb, ac 415 volts, 4 pole, 200 amps current rating, 36 ka rupturing capacity with adjustable ( 70% to 100% ) thermal setting and fixed magnetic setting conforming to is: 13947 11 complete with connections to the bus bars. 01 no. ( ii ) aluminium bus bar strip of rated capacity 300 amps with coloured pvc insulating sleeves, mounted on post insulators, 1100 volt grade. 04 nos. ( iii ) voltmeter 0 500 volts digital type, flush mounting with selector switch 01 set ( iv ) ammeter 0 100 amps digital type, flush mounted, with cts and selector switch. 01 set ( v ) phase indicator lamps, led type 01 set ( ryb ) ( vi ) panel instrument fuses 01 setoutgoings ( i ) mccb 160amp 25ka 4p 415volts 01nos with adjustable thermal magnateic release ( ii ) mccb 32amp 16ka4p 415volts 04nos with adjustable thermal magnateic release 36 supply, installing, connecting electrically, testing and commissioning factory made cubicle type dust and vermin proof lt panel box of suitable size outdoor type, made out of 3.15 mm thick crca sheet and 50x50x6 mm ( isa 5050 ) ms angle frame with hinged cubicle doors with locking arrangement, duly spray painted comprising of the following accessories : incoming ( i ) mccb, ac 415 volts, 4 pole, 160 amps current rating, 25 ka rupturing capacity with adjustable ( 70% to 100% ) thermal setting and fixed magnetic setting conforming to is: 13947 11 complete with connections to the bus bars. 01 no. ii ) aluminium bus bar strip of rated capacity 300 amps with coloured pvc insulating sleeves, mounted on post insulators, 1100 volt grade. 04 nos. iii ) voltmeter 0 500 volts digital type, flush mounting with selector switch. 01 set ( iv ) ammeter 0 100 amps digital type, flush mounted, with cts and selector switch. 01 set ( v ) phase indicator lamps, led type. 01 set ( ryb ) vi ) panel instrument fuses 01 setoutgoings ( i ) mccb 80amp 16ka 4p 415volts 03nos with adjustable thermal magnateic release 37 supply, installing, connecting electrically, testing and commissioning factory made cubicle type dust and vermin proof lt panel box of suitable size outdoor type, made out of 3.15 mm thick crca sheet and 50x50x6 mm ( isa 5050 ) ms angle frame with hinged cubicle doors with locking arrangement, duly spray painted comprising of the following accessories : incoming ( i ) mccb, ac 415 volts, 4 pole, 80 amps current rating, 16 ka rupturing capacity with adjustable ( 70% to 100% ) thermal setting and fixed magnetic setting conforming to is: 13947 11 complete with connections to the bus bars. 01 no. ii ) aluminium bus bar strip of rated capacity 200 amps with coloured pvc insulating sleeves, mounted on post insulators, 1100 volt grade. 04 nos. iii ) voltmeter 0 500 volts digital type, flush mounting with selector switch. 01 set ( iv ) ammeter 0 100 amps digital type, flush mounted, with cts and selector switch. 01 set ( v ) phase indicator lamps, led type. 01 set ( ryb ) vi ) panel instrument fuses 01 setoutgoings ( i ) mccb 63amp 16ka 4p 415volts 01nos with adjustable thermal magnateic release. ( i ) mccb 32amp 16ka 4p 415volts 02nos with adjustable thermal magnateic release 38 note for item no 5.01 & 5.03 : the rate quoted by the contractor shall be deemed to include following provision of platform for the panel with pcc 1:4:8 type d 2 using 40mm graded crushed stone aggregate, 15 cm thick in foundation, brick work in cm 1:6 with sub class b old size bricks, rendering sub class b old size bricks, rendering 15 mm thick in cm 1:6 on exposed surfaces and 100mm thick pcc padding ( 1:3:6 ) type c 1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. the platform shall be at a height of 45 cm above the nearest road level. the platform shall be constructed as per manufacturer drawing and design. 39 m&l for earthing complete with galvanized steel earth plate electrode 600x600x6.0mm thick buried directly in ground ( earth pit not less than 2.25 meters deep below ground level ) with top edge of the plate not less that 1.5 meters below normal ground level connected to galvanized iron strip 25 x 4 mm mm as earthing by means of bolts nuts and washers of galvanized iron including excavation and earth work and disposal of surplus soil including 40 mm gl tubing light grade and necessary fittings for protection of gl strip including laying of charcoal, dust and common slat, pcc 1:2: 4 type b 1 using 20 mm graded aggregate with earth pit with 40 x 40 x 6.0 mm ms angle iron frame rcc cover 40 mm thick ( 1:2: 4 ) type c1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75 mm c / c both way with plastering 15 mm thick cm ( 1:6 ) internally and up to 150 mm below ground level externally . pgi funnel with wire mesh , 20 mm dia medium grade gl pipe for watering complete all as shown on electrical plate no : 03 of ssr part 1 2009 and connected to earth test point including testing completed all specified and directed. ( note: 14 numbers for internal electrification & 8 number for external elecrification ) 40 all as per srl item no.5.05 above but gi earth lead wire 4.00 mm dia earthing for street light poles etc complete all as specified and directed. 41 s&f led security light fitting energy efficient 45 watt high pressure die cast aluminium housing, heat resistant toughened glass with frame, ip 66 protection complete and connection with suitable cable from weather proof street light junction box to light fitting and fixing on gl pipe bracket made out of suitable dia gl pipe medium grade 1.2 mtr long bend to shape and fixed on pole with flat iron clamps, nut, bolts, washer etc all as specified and directed. 42 s&f weather proof street light junction box double door of size 325 x 225 x 150 mm made out of pvc / hdpe fir retardant, non fusing, shock & rust proof, single piece moulded / smc housing and smc cover with hinged door, pole mounting type comprising of al busbar 6amp mcb fixed on pole with ms clamp with necessary nuts, washer, duly painted with two coats of synthetic enamel paint over a red oxide primer on steel surface / clamps and embossing / painting of danger sign of size not less than 10cmx 7.5 cm with letter and conventional skull and bones in signal red colour on front face of street light junction box complete all as directed. 43 s&f automatic timer switch to switches on / off the street lights base on pre set timings current rating 15 amps, 220 volts, 50 hz. the microprocessor based astronomical based timer should also have over voltage protection alongwith suitable power contactor, mcb and support terminals should be enclosed in pole / wall mountable enclosure made of rust proof electric shock proof termite proof and fr grade special moulding compounds confirming to ip 54. the contactor mcb and circuit wiring shall have enough capacity to take load of 5 kw equally distributed over 3 phase complete all as specified and directed. 44 labour only for carrying out horizontal boring below roads / pcc hard standing / drain suitable for 80mm dia gl pipe medium grade all as specified as directed incl inserting gl pipe to a depth upto 1.5m & including hardstanding upto width of 12m complete all as specified and as directed. 45 heating applicances 46 s&f mcb single pole 6 to 32 amps 240 v.10ka, b series complete all as specified and as directed. 47 supply, installation, testing and commissioning of solar water system ( flat plate collector ) based on indirected transfer of heat of capacity 300 lpd with electrical heating back upto 3kw including suitable size angle iron stand for stagging of solar water heater and pcc, hot water and cold water connection, electric connection with all accessories complete all as specified and directed. 48 cooling appliances 49 supply and install desert cooler with isi marked fan and made out of ms sheet 11.6mm thickness electric driven single phase copper wound fan motor and water pump motor having nominal air flow capacity of 5000 cubic meter per hour or nearest higher sire ( without any financial effect ) in steel body.it includes the provision of connect gl tubing 15mm size with pvc connection, gland, ball valve and wire for electric connection copper wire 3 core size 1.5 sqmm appx length 3 mtr in desert cooler complete all as specified and as directed by engineer in charge.note wire for electric connection is deemed to be included in quoted rate but pvc connection, ball valve and gl tubing are separately measured. 50 supply and installed voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 135 v to 280 v with: output voltage stabilized at 230 v with accuracy of ± 2.5% and of capacity 1 kva used for deep freezer / refrigerator complete all as specified and directed. 51 supply and install frost free, double door, isi marked 5 star convertible refrigerator electric driven, single phase of capacity 310 litres or nearest higher capacity ( without any financial affect ) complete all as directed. 52 road, path and culvert 53 m&l for thermoplastic paint on black top surfaces or existing paint surfaces applied hot mixing plant of heating of thermo plastic materials to a standard temp with gas and laying standard thickness of approx 2mm, by using thermo plastic material @ 6.5 kg / sqm, and glass beads @ 250 gms / sqm including cleaning of old surfaces, complete all as specified and directed....

Industrial Training Institute - Haryana

34936758 bids are invited for list of item 2 / 69 measuring scale , portable disk sander , solar water system , plane table , templates , prismatic compass , leveling staff , gun spray with gravity feed cup with complete accessories , conventional spray gun for pressure feed with complete accessories , electric spray gun with complete accessories , pencil hardness tester , airless sprey gun unit with complete accessories , spanner ring set of 12 metric sizes 6 to 32 mm , steel tool box with lock and key folding type 400x200x150 mm , 3 furrow disc plough with scrapper syk , allen key set of 12 pieces 2 mm to 14 mm , chaser hand ww 9 to 40 t.p.i. set of 11 internal , dial gauge type 1 grade a complete with clamping devices and with magnetic stand , groover , insulated screw driver 20x9 cm , insulated screw driver 30 cm x9mm blade , lifting jack screw type 3 ton capacity , screw driver set of 5 pieces 100 mm to 300 mm , portable oil monitoring indicator , rear axle assembly gear box steering box assembly of the diesel engine , spanner d.e. set of 12 pieces 6 mm to 32 mm , spanner socket with speed handle t bar ratchet and universal upto 6mm to 32 mm set of 28 pieces with box , spring tension tester , vaccum gauge to read 0 to 760 mm of hg , vernier caliper 0 300 mm with least count 0.02 mm , voltmeter 50vdc , wire gauge metric , work bench with 4 vice , injector multi hole type , caliper inside with spring , caliper outside with spring , divider with spring , diesel smoke meter , air ratchet with standard accessories , hand operated crimping tool , hand reamer adjustable , set of stock dies metric , fuel injection pump ve pump distributor fuel rotary pump dpc pumps along with special tool and accessories total quantity : 383...

Military Engineer Services - Haryana

31912701 provision of otm accn under ge ( af ) gurgaon construction of single living accn for jcoscomplete all as specified and shown on drawings. 3 construction of single living accn for havs / ors complete all as specified and shown on drawings. 4 construction of cook house and dining hall complete all as specified and shown on drawings. 5 construction of office accn complete all as specified and as shown on drawings. 6 construction of mt shed ( 3 x 2.5 ton and 1 x als ) complete all as specified and as shown on drawings. 7 construction of mt shed ( 2 x gepsy & 1 x motor cycle ) complete all as specified and as shown on drawings. 8 construction of garage for 32 motor cycle complete all as specified and as shown on drawings. 9 construction of garage for 02 gypsy complete all as specified and as shown on drawings. 10 construction of storage accn complete all as specified and as shown on drawings. 11 construction of unit shop complete all as specified and as shown on drawings. 12 note: schedule ‘a’ part iito xii under are prepriced by mes. 13 lump sum price worked out by the contractor for “excavation and earth work” as listed in schedule ‘a’part ii 14 lump sum price worked out by the contractor for “internal electrification as listed in schedule ‘a’part iii 15 lump sum price worked out by the contractor for “internal water supply as listed in schedule ‘a’part iv 16 lump sum price worked out by the contractor for sewage disposal” as listed in schedule ‘a’part v 17 lump sum price worked out by the contractor for “area drainage” as listed in schedule ‘a’part vi 18 lump sum price worked out by the contractor for “road, path and culvert” as listed in schedule ‘a’part vii 19 lump sum price worked out by the contractor for“external water supply ” as listed in schedule ‘a’part viii 20 lump sum price worked out by the contractor for“external electrification ” as listed in schedule ‘a’part ix 21 lump sum price worked out by the contractor for“compound wall & gate ” as listed in schedule ‘a’part x 22 lump sum price worked out by the contractor for“cooling appliances ” as listed in schedule ‘a’part xi 23 lump sum price worked out by the contractor for“heating appliances ” as listed in schedule ‘a’part xii 24 schedule `a part xiii miscb / r & e / m itemsis not prepriced by mes and prepriced rates indicates 0.0 under column 6 signified this fact only. 25 internal electrification 26 s&f led lamp 10 watt, 230 volts retrofit type complete all as specified and directed. 27 s&f energy saving decorative box type batten led tube light fitting 230 volts surface mounted complete with high efficiency pmma diffuser soft glare free light led tube light 20w, blue coloured end caps with all accesseries prewired with three core flexible copper cable 0.50 sqmm pvc insulated sheathed complete all as specified and directed. 28 s&f led sleek mirror light fitting 10 watt surface mounted provided with high output diffuser 2 ft long, 230 volts, complete with all accessories, pre wired including lamp and providing flexible copper wire, three core cable pvc insulated sheathed complete all as specified and directed. 29 s&f led building security light fitting 20 watt having uniformity ratio 0.25, high pressure dia cast aluminium housing, heat resistant toughened glass with frame, ip66 protection complete with lamp & connected items and connection with suitable cable from ceiling rose to light fitting and including gl pipe bracket made out of suitable dia gl pipe medium grade 1.2mtr long bent to shape and fixed on wall with flat iron clamps, nut. bolts washer etc all as specified and directed. 30 s&f led light fitting 36 watt, 600x600mm size, surface mounted provided with high output diffuser, 230 volts complete with all accessories, pre wired including lamp and prewired with three core flexible copper cable 0.50 sqmm pvc insulated sheathed complete all as specified and directed. 31 s&f mcb sp6 to 32 amps, c curve type, 10ka breaking capacity, 240 volts complete all as specified and directed. 32 external water supply 33 m&l for construction of valve pit chamber 90 cmx90cm ( inner dimension ) and 90 cm deep , from the top of ms cover fixed on pcc base, top cover shall be of 3 mm thick ms sheet with locking arrangement of pad lock of 50mm size including brick work with sub classb bricks in cm 1:4 including 15 mm thick plaster in cm 1:4 ( internally and externally ) and necessary earth work in anu type of soil including returning filling in and disposal of surplus oil to a distance n exc 50 mtrs and 150 mm thick pcc 1:4:8 , type d 2 , using 40mm graded stone aggregates as in floor complete all as specified and directed. 34 external electric supply 35 supply, installing, connecting electrically, testing and commissioning factory made cubicle type dust and vermin proof lt panel box of suitable size outdoor type, made out of 3.15 mm thick crca sheet and 50x50x6 mm ( isa 5050 ) ms angle frame with hinged cubicle doors with locking arrangement, duly spray painted comprising of the following accessoriesincoming ( i ) mccb, ac 415 volts, 4 pole, 200 amps current rating, 36 ka rupturing capacity with adjustable ( 70% to 100% ) thermal setting and fixed magnetic setting conforming to is: 13947 11 complete with connections to the bus bars. 01 no. ( ii ) aluminium bus bar strip of rated capacity 300 amps with coloured pvc insulating sleeves, mounted on post insulators, 1100 volt grade. 04 nos. ( iii ) voltmeter 0 500 volts digital type, flush mounting with selector switch 01 set ( iv ) ammeter 0 100 amps digital type, flush mounted, with cts and selector switch. 01 set ( v ) phase indicator lamps, led type 01 set ( ryb ) ( vi ) panel instrument fuses 01 setoutgoings ( i ) mccb 160amp 25ka 4p 415volts 01nos with adjustable thermal magnateic release ( ii ) mccb 32amp 16ka4p 415volts 04nos with adjustable thermal magnateic release 36 supply, installing, connecting electrically, testing and commissioning factory made cubicle type dust and vermin proof lt panel box of suitable size outdoor type, made out of 3.15 mm thick crca sheet and 50x50x6 mm ( isa 5050 ) ms angle frame with hinged cubicle doors with locking arrangement, duly spray painted comprising of the following accessories : incoming ( i ) mccb, ac 415 volts, 4 pole, 160 amps current rating, 25 ka rupturing capacity with adjustable ( 70% to 100% ) thermal setting and fixed magnetic setting conforming to is: 13947 11 complete with connections to the bus bars. 01 no. ii ) aluminium bus bar strip of rated capacity 300 amps with coloured pvc insulating sleeves, mounted on post insulators, 1100 volt grade. 04 nos. iii ) voltmeter 0 500 volts digital type, flush mounting with selector switch. 01 set ( iv ) ammeter 0 100 amps digital type, flush mounted, with cts and selector switch. 01 set ( v ) phase indicator lamps, led type. 01 set ( ryb ) vi ) panel instrument fuses 01 setoutgoings ( i ) mccb 80amp 16ka 4p 415volts 03nos with adjustable thermal magnateic release 37 supply, installing, connecting electrically, testing and commissioning factory made cubicle type dust and vermin proof lt panel box of suitable size outdoor type, made out of 3.15 mm thick crca sheet and 50x50x6 mm ( isa 5050 ) ms angle frame with hinged cubicle doors with locking arrangement, duly spray painted comprising of the following accessories : incoming ( i ) mccb, ac 415 volts, 4 pole, 80 amps current rating, 16 ka rupturing capacity with adjustable ( 70% to 100% ) thermal setting and fixed magnetic setting conforming to is: 13947 11 complete with connections to the bus bars. 01 no. ii ) aluminium bus bar strip of rated capacity 200 amps with coloured pvc insulating sleeves, mounted on post insulators, 1100 volt grade. 04 nos. iii ) voltmeter 0 500 volts digital type, flush mounting with selector switch. 01 set ( iv ) ammeter 0 100 amps digital type, flush mounted, with cts and selector switch. 01 set ( v ) phase indicator lamps, led type. 01 set ( ryb ) vi ) panel instrument fuses 01 setoutgoings ( i ) mccb 63amp 16ka 4p 415volts 01nos with adjustable thermal magnateic release. ( i ) mccb 32amp 16ka 4p 415volts 02nos with adjustable thermal magnateic release 38 note for item no 5.01 & 5.03 : the rate quoted by the contractor shall be deemed to include following provision of platform for the panel with pcc 1:4:8 type d 2 using 40mm graded crushed stone aggregate, 15 cm thick in foundation, brick work in cm 1:6 with sub class b old size bricks, rendering sub class b old size bricks, rendering 15 mm thick in cm 1:6 on exposed surfaces and 100mm thick pcc padding ( 1:3:6 ) type c 1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. the platform shall be at a height of 45 cm above the nearest road level. the platform shall be constructed as per manufacturer drawing and design. 39 m&l for earthing complete with galvanized steel earth plate electrode 600x600x6.0mm thick buried directly in ground ( earth pit not less than 2.25 meters deep below ground level ) with top edge of the plate not less that 1.5 meters below normal ground level connected to galvanized iron strip 25 x 4 mm mm as earthing by means of bolts nuts and washers of galvanized iron including excavation and earth work and disposal of surplus soil including 40 mm gl tubing light grade and necessary fittings for protection of gl strip including laying of charcoal, dust and common slat, pcc 1:2: 4 type b 1 using 20 mm graded aggregate with earth pit with 40 x 40 x 6.0 mm ms angle iron frame rcc cover 40 mm thick ( 1:2: 4 ) type c1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75 mm c / c both way with plastering 15 mm thick cm ( 1:6 ) internally and up to 150 mm below ground level externally . pgi funnel with wire mesh , 20 mm dia medium grade gl pipe for watering complete all as shown on electrical plate no : 03 of ssr part 1 2009 and connected to earth test point including testing completed all specified and directed. ( note: 14 numbers for internal electrification & 8 number for external elecrification ) 40 all as per srl item no.5.05 above but gi earth lead wire 4.00 mm dia earthing for street light poles etc complete all as specified and directed. 41 s&f led security light fitting energy efficient 45 watt high pressure die cast aluminium housing, heat resistant toughened glass with frame, ip 66 protection complete and connection with suitable cable from weather proof street light junction box to light fitting and fixing on gl pipe bracket made out of suitable dia gl pipe medium grade 1.2 mtr long bend to shape and fixed on pole with flat iron clamps, nut, bolts, washer etc all as specified and directed. 42 s&f weather proof street light junction box double door of size 325 x 225 x 150 mm made out of pvc / hdpe fir retardant, non fusing, shock & rust proof, single piece moulded / smc housing and smc cover with hinged door, pole mounting type comprising of al busbar 6amp mcb fixed on pole with ms clamp with necessary nuts, washer, duly painted with two coats of synthetic enamel paint over a red oxide primer on steel surface / clamps and embossing / painting of danger sign of size not less than 10cmx 7.5 cm with letter and conventional skull and bones in signal red colour on front face of street light junction box complete all as directed. 43 s&f automatic timer switch to switches on / off the street lights base on pre set timings current rating 15 amps, 220 volts, 50 hz. the microprocessor based astronomical based timer should also have over voltage protection alongwith suitable power contactor, mcb and support terminals should be enclosed in pole / wall mountable enclosure made of rust proof electric shock proof termite proof and fr grade special moulding compounds confirming to ip 54. the contactor mcb and circuit wiring shall have enough capacity to take load of 5 kw equally distributed over 3 phase complete all as specified and directed. 44 labour only for carrying out horizontal boring below roads / pcc hard standing / drain suitable for 80mm dia gl pipe medium grade all as specified as directed incl inserting gl pipe to a depth upto 1.5m & including hardstanding upto width of 12m complete all as specified and as directed. 45 heating applicances 46 s&f mcb single pole 6 to 32 amps 240 v.10ka, b series complete all as specified and as directed. 47 supply, installation, testing and commissioning of solar water system ( flat plate collector ) based on indirected transfer of heat of capacity 300 lpd with electrical heating back upto 3kw including suitable size angle iron stand for stagging of solar water heater and pcc, hot water and cold water connection, electric connection with all accessories complete all as specified and directed. 48 cooling appliances 49 supply and install desert cooler with isi marked fan and made out of ms sheet 11.6mm thickness electric driven single phase copper wound fan motor and water pump motor having nominal air flow capacity of 5000 cubic meter per hour or nearest higher sire ( without any financial effect ) in steel body.it includes the provision of connect gl tubing 15mm size with pvc connection, gland, ball valve and wire for electric connection copper wire 3 core size 1.5 sqmm appx length 3 mtr in desert cooler complete all as specified and as directed by engineer in charge.note wire for electric connection is deemed to be included in quoted rate but pvc connection, ball valve and gl tubing are separately measured. 50 supply and installed voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 135 v to 280 v with: output voltage stabilized at 230 v with accuracy of ± 2.5% and of capacity 1 kva used for deep freezer / refrigerator complete all as specified and directed. 51 supply and install frost free, double door, isi marked 5 star convertible refrigerator electric driven, single phase of capacity 310 litres or nearest higher capacity ( without any financial affect ) complete all as directed. 52 road, path and culvert 53 m&l for thermoplastic paint on black top surfaces or existing paint surfaces applied hot mixing plant of heating of thermo plastic materials to a standard temp with gas and laying standard thickness of approx 2mm, by using thermo plastic material @ 6.5 kg / sqm, and glass beads @ 250 gms / sqm including cleaning of old surfaces, complete all as specified and directed....

Military Engineer Services - Haryana

9234751 repair / replacement to ceiling fans, exhaust fans wall mounted fans, gysers, solar water system with connected wiring and e / m items at af stn sirsa...

Military Engineer Services - Haryana

9033752 repair / replacement to ceiling fans, exhaust fans, wall mounted fans, gysers, solar water system with connected wiring and electromechanical items....

Military Engineer Services - Haryana

7431822 repair/ replacement to gysers, solar water system, ceiling fans, exhaust fans with connected wiring of electromechanical items at af stn sirsa, ge/sra/t 50/14 15...

Military Engineer Services - Haryana

7357786 repair/ replacement to gysers, solar water system, ceiling fans, exhaust fans with connected wiring of electromechanical items at af stn sirsa, ge/sra/t 50/2014 15...