Haryana Power Generation Corporation Limited - Haryana
39427658 supply of fabric compensators for ptps, panipat 1 boiler spares item name:fabric compensator size:l:8 mtr w:250mm equipment:ducts, dampers, gates make:not available model:not available capacity:110 mw additional information: for pa rah, working temperature:400 deg celcius 2 boiler spares item name:fabric compensator size:l:12 mtr w:400mm equipment:ducts, dampers, gates make:not available model:not available capacity:110 mw additional information:for sa rah outlet to wind box, working temperature:400 deg celcius 3 boiler spares item name:fabric compensator size:l:20 mtr, w:600mm assembly:ducting guide vanes equipment:air heater make:bhel model:27 vitm 1850 ( 2000 ) capacity:210 mw additional information:for eco.outlet, working temperature:350°c 4 boiler spares item name:fabric compensator size:l:21 mtr, w:300 mm equipment:ducts, dampers, gates make:bhel model:not available capacity:210 mw additional information:for secondary air rah outlet, working temperature 350 degree celcius, design temp. 400 deg. celcius, dust concentration 50 gm / nm3 5 boiler spares item name:fabric compensator size:l:17 mtr, w:500 mm equipment:ducts, dampers, gates make:bhel model:not available capacity:210 mw additional information:for primary air from rah outlet, working temperature:350°c, design temp.:400°c, dust concentration:50 gm / nm3, pressure rating:1000mmwc 6 boiler spares item name:fabric compensator size:l:13 mtr, w:400 mm equipment:ducts, dampers, gates make:bhel model:not available capacity:210 mw additional information:for flue gas rah outlet, est vertical, working temperature:350°c, design temp.:400°c, dust concentration:50gm / nm3 7 boiler spares item name:fabric compensator size:l:26 mtr, w:200 mm equipment:ducts, dampers, gates make:bhel model:not available capacity:210 mw additional information:for for rah utlet, size:3364x8470, working temperature:350°c, design temp.:400°c, dust concentration:50gm / nm3 8 boiler spares item name:fabric compensator size:l:12 mtr, w:300 mm equipment:ducts, dampers, gates make:bhel model:not available capacity:210 mw additional information:dust concentration:50gm / nm3, working temperature: 350°c; suitable for hot pa to mil 9 boiler spares item name:fabric compensator size:l:17mtr, w:400 mm material:silicon coated reinforcement with treated glass fabric equipment:ducts, dampers, gates make:bhel model:not available capacity:210 mw additional information:suitable for rcej of flue gas duct from rah to esp inlet duct, working temperature= 350°c; design temp.=400 deg. celcius, dust concentration 50gm / mm3, pressure rating: 1000mmwc 10 boiler spares item name:fabric compensator type:multilayered size:l:12mtr, w:600 mm material:silicon coated reinforcement with treated glass fabric equipment:ducts, dampers, gates make:bhel model:not available capacity:210 mw additional information:suitable for rcej of hot primary air duct from rah to mill , working temperature= 350°c; design temp.=400 deg. celcius, dust concentration 50gm / mm3, pressure rating: 1000mmwc 11 boiler spares item name:fabric compensator type:multilayered size:l:14mtr, w:500 mm material:silicon coated reinforcement with treated glass fabric equipment:ducts, dampers, gates make:bhel model:not available capacity:210 mw additional information:suitable for rcej of secondary air duct from rah to wind box inlet , working temperature= 350°c; design temp.=400 deg. celcius, dust concentration 50gm / mm3, pressure rating: 1000mmwc 12 boiler spares item name:fabric compensator size:l:18 mtr, w:300 mm equipment:ducts, dampers, gates make:not available model:not available capacity:250 mw additional information:dust concentration:50gm / nm3, working temperature:300 deg celcius 13 boiler spares item name:fabric compensator size:length:27mtr, width:600 mm equipment:ducts, dampers, gates make:not available model:not available capacity:250 mw additional information:dust concentration:50gm / nm3, working temperature:350°c;suitable for eco outlet in flue gas 14 boiler spares item name:fabric compensator size:length:31mtr, width:400mm equipment:ducts, dampers, gates make:not available model:not available capacity:250 mw additional information:dust concentration:50gm / nm3, working temperature:350°c;suitable for aph inlet in flue gas 15 boiler spares item name:fabric compensator size:length:31mtr, width:300mm equipment:ducts, dampers, gates make:not available model:not available capacity:250 mw additional information:dust concentration:50gn / nm3, working temperature:200°c;suitable for aph outlet in flue gas 16 boiler spares item name:fabric compensator size:length:22mtr, width:300mm equipment:ducts, dampers, gates make:not available model:not available capacity:250 mw additional information:dust concentration:50gm / nm3, working temperature:300°c; suitable for aph outlet in secondary air 17 boiler spares item name:fabric compensator size:length:14mtr, width:300mm equipment:ducts, dampers, gates make:not available model:not available capacity:250 mw additional information:dust concentration:50gm / nm3, working temperature:300°c;suitable for secondary air interconnection 18 boiler spares item name:fabric compensator size:length:9.5mtr, width:300mm equipment:ducts, dampers, gates make:not available model:not available capacity:250 mw additional information:dust concentration:50gm / nm3, working temperature:270°c;suitable for hot pa to mill ...