Military Engineer Services - Haryana

40426663 tender for repair / maintenance of ht ug / oh network, ht vcbs, rmus, distribution transformers and connected works at sector b area under ge ( utility ) ambala cantt; 1 excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes,for under ground cable / erection of poles, stays etc not exceeding 10 square metre on plan and getting out in soft/loosesoil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and as directed. 2 all as per item no. 1 above but excavation depth exceeding 1.5 metre and not exceeding 3.0 metre. 3 material and labourfor sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cmsdeep after laying the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed.note: punned thickness 18cm shall be measured for payment purposes. 4 supplying and laying un reinforced precast cement concrete cable cover, class hv, type 1, with peak, size 300mm x 180 mm x 40 mm, complete, all as specified and as directed. 5 supply and erecting prestressed concrete pole 11.0 mtr long in true vertical position 152x152 mm at top and 152x260 mm at bottom, class 9, conforming to is 1678 and including marking alternate 05 nos white and black strip 30cm height with two coats ofsynthetic enamel paint includingpreparation of surfaces, upto 1.5 metre above the coping of pole, starting with black strip, including dismantling and taking down of old unserviceable pcc ht pole complete all as specified and as directed. note: excavation, earth work, pcc work, channel, clamps, nuts, bolts etc shall be measured and paid separately. 6 supply and erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 sp 55 (11.0 metres long) conforming to is 1678 and including marking alternate 05 nos white and black strip 30cm height with two coats ofsynthetic enamel paint includingpreparation of surfaces, upto 1.5 metre above the coping of pole, starting with black strip, including dismantling and taking down of old unserviceable steel tubular ht pole complete all as specified and directed. note: excavation and earth wok and pcc for foundation, channel, clamps nuts, bolts to be measured and paid separately. 7 material and labour for plain cement concrete 1:4:8 type d 2 (using 40 mm graded mechanically crushed stone aggregate), as in foundation filling and mass concrete, complete, all as specified and as directed. 8 material and labour for plain cement concrete 1:3:6 type c 2 (using 40 mm graded mechanically crushed stone aggregates) as in fixing of hold fast, coping of pole and strut, bed plates and the like, finishing the surface fair and even, including necessary form work, complete, all as specified and as directed. 9 returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick of any description, complete, all as specified and as directed. 10 removing excavated soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.5m above the starting point, complete, all as specified and as directed. 11 supply and fixing in replacement of gi tubing, 80mm bore, light grade, for cable protection along/on poles/culvert/drainage or under road crossing, complete, all as specified and as directed. 12 supply and fixing in replacement of gi tubing, 100mm bore, light grade, for cable protection along/on poles/culvert/drainage or under road crossing, complete, all as specified and as directed. 13 supply and fixing in replacement of gi tubing, 150mm bore, light grade, for cable protection along/on poles/culvert/drainage or under road crossing, complete, all as specified and as directed. 14 supply and fixing in replacement of danger notice plate 1.60 mm thick of size 25x20 cm, mild steel sheet, vitreous enameled red colour, with letters, figures and conventional skull and bones in signal white colour and fixed with m.s. clamps, bolts and nuts of approved size for ht, complete, all as specified and as directed. 15 supply, installing, testing and commissioning of air break gang operated triple switch (godo) outdoor type, vertical mounting type of capacity 200 amp with drop out fuse consisting 12 insulators, isi marked mechanically operated, mounted on insulator and frame work with operating gi rods and mechanical work from ground level with locking arrangement including godrej pad lock with two keys complete with fuse carrier and ht fuse element having upto 200 amp rating suitable for ht 11 kv 50 hz ac supply including necessary electric connection and dismantling and taking down of old unserviceable god complete all as specified and directed. 16 material and labour in replacement of lightning arrester expulsion type, suitable for 11000 volt, with allfittings, trasmission class,discharge capacity 65 ka including connecting with ht line and dismantling and taking down of old unserviceable lightning arrester complete all as specified and as directed. 17 material and labour for aluminium conductor steel reinforced (acsr)weasel/squirrel conductor from 66 kv sub station and other areas, including fixing, stretching on poles and proper noseling with binding wire to insulator of any size on 11 kv oh line as required at site and dismantling and taking down of old unserviceable acsr conductor complete all as specified directed. 18 takingout old unserviceable earthing material and provision of new earthing complete with galvanisedearth plate electrode 600mm x 600mmx 6mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m belowground level with top edge of the earthplate not less than 1.5m belownormal groundlevel, connected to 4.00 mmwire earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 15mm dia (light grade) and connected to main switch or main control board all as shown in electrical plate no.3 of ssr part i & including necessary excavation and earth work. the rate also include charcoal & salt in alternate layers, 20mm dia gi pipe (light grade) for watering, protection pipe, funnel, wire mesh,rcc cover etc, complete, all as specified or indicated and as directed including testing on completion. 19 taking out old unserviceable earthing material and provision of new earthing complete galvanisedearth plate electrode 600mm x 600mmx 6.00mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m belowground level with top edge of the earthplate not less than 1.5m belownormal groundlevel, connected to 25x4 mm gi strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm dia (light grade) and connected to main switch or main control board all as shown in electrical plate no.3 of ssr part i & including necessary excavation and earth work. the rate also include charcoal & salt in alternate layers, 20mm dia gi pipe (light grade) for watering and 40mm giprotection pipe, funnel, wire mesh,cast iron cover andframe etc, complete, all as specified or indicated and as directed including testing on completion. 20 taking out old unserviceable earthing material and provision of new earthing complete copper plate electrode 600mm x 600mmx 3.15mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m belowground level with top edge of the earthplate not less than 1.5m belownormal groundlevel, connected to 20x3 mm copper strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 32mm dia (medium grade) and connected to main switch or main control board all as shown in electrical plate no.3 of ssr part i & including necessary excavation and earth work. the rate also include charcoal & salt in alternate layers, 20mm dia gi pipe (light grade) for watering and 40mm giprotection pipe, funnel, wire mesh,cast iron cover andframe etc, complete, all as specified or indicated and as directed including testing on completion.notes for item nos 18.00, 19.00 & 20.00 : (i) the quoted rate shall include the cost of earth work, gi pipe for watering, gi protection pipe, funnel, wire wesh, rcc cover, etc. complete. rcc cover shall be 50mm thick in 1:2:4 type b 1 using 8mm bars @10cm c/c both way.(ii) the quoted rate shall include the cost of earth pit covers to be conspicuously marked of plate with stand grouted in pcc.(iii) on testing after completion if the desired earth resistance is more than 2 ohm the earthing will be redone at no extra cost. 21 dismantling and taking down of old unserviceable cross arms, clamps, bracing, etc. of any section from pole including nuts, bolts, washers and cutting of bolts (slag bolts) if required complete and material and labour for new cross arm bracing supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling hole for bolts in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide primer complete, all as specified and as directed. 22 supply and fixing pin type, porcelain,vitreous,white or brown or green insulators,11000 volts grade of 150 mm dia, 150 mm height including one galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nuts and dismantling and taking down of old unserviceable insulators complete all as specified and as directed. 23 supply and fixing disc type insulators, porcelain, vitreous 145 mm height and 255 mm dia ball and socket type, white, brownor green single disc assembly for tension with tension clamps for conductor, working pressure 11000 volts grade,and dismantling and taking down of old unserviceable insulators complete all as specified and as directed. 24 supply and fixing of stay assembly complete with all accessories such as stay plate 300mmx300mmx6mm,stay rod 20 mm dia and 215cm long threaded end with nuts including 14mm dia gistay bow. turn buckle,etc. complete, all as shown in electrical plate no 1 of ssr part i 2009 complete including dismantling and taking down of old unserviceable stay assembly all as specified and as directed. note the quoted rate shall include the cost of loop type insulator, stay clamps, excavation, pcc, stay wire, stay bow, turn buckle, nuts etc., excavation, demolition and removal of demolished concrete outside defence land complete. 25 supply only in replacement of silica gel 4 6 mesh suitable for transformers breather andprotect vcbs, rmus from moisture at66 kv / 11 kv stations complete as per site requirement complete, all as specified and as directed. 26 material and labour for detecting of fault in ug cable with fault locator equipment which is capable to supplyas per cable of (11 kv/430 volts) serviceable to cable complete all as specified and directed.note : (a) the fault which is detected through cable fault locater will only be paid under this item. (b) charges of cable fault locator and dg set including transportation charges deemed to be included in the quoted rate. (c ) earth fault locator will be provided by the contractor for even singlefault and no dealy on this account will be acceptable otherwise penality will levied rs 500/ per day.(d) (d) necessarytesting of cable after making joint will be deemed to be including in the cost of relevent item. however necessary earth work cable cutting, joint making jointwill be paid under relevant item. 27 supply andfixing of self fusing ethylene propylene rubber(epr)based high insulating voltage tape of width not less than 19 mm and thickness not less than 0.75 mm of any length to protectht/lt xlpe cable from moisture and current leakage complete, all as specified and as directed. 28 material and labour for boaring of holes under road, pavement, hard standing of any material and description,by trench less technology using ultra sound technique or manual boringincluding providing hdpe pipe of 80 150mm dia suitable for 0.4 mpa working pressure complete, all as specified and as directed.note: boring depth as decided by engineer in charge.material and labour for augering of hole of suitable dia & providing heavy duty hdpe pipe of size 80 150mm dia in true horizontal drill under existing national highway,road and railway track, buildings comlpete all as directed by engineer in charge.note: (i) the auguring of horizontal hole will be carried out through trenchless horizontal boring machine as shown in site plan.(ii) the cost of hdpe pipe machinery ,transportation,dg set etc included in the rate quoted.(iii) the boring will be carried out upto 03 mtr deep below the railway track ground level and nh 1 a line cost of excavation of working space as both side of trenchless boring will be deemed to be included in the rate quoted. (iv) while carrying out the work below railway track and nh 1 a , the contractor will adhere to instruction issued by the respective authority. the work will be carried out of at such places under the supervision of mes and railway/ highway authirities. (v) any damage of other property like sewage pipes, other cables , water pipes etc will be repaired/replaced under this item without extra cost , department will not responsible of any damage. 29 supplying and laying of xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 95 sqmm 3 core, suitable for 11 kv earthed system confirming to is 7098 part 2 for insulation and for conductors class 2 to is 8130 84, in trenches, floors, ducts passing through pipe forroad crossing etc, including connecting & testing and disconnecting and taking down of old unserviceable ht cable complete all as specified and directed.(note : excavation, earth work, brick protection, sand cushioning and gi pipe etc shall be measured & paid for separately). 30 supplying and laying of xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 120 sqmm 3 core, suitable for 11 kv earthed system confirming to is 7098 part 2 for insulation and for conductors class 2 to is 8130 84, in trenches, floors, ducts passing through pipe forroad crossing etc, including connecting & testing and disconnecting and taking down of old unserviceable ht cable complete all as specified and directed.(note : excavation, earth work, brick protection, sand cushioning and gi pipe etc shall be measured & paid for separately). 31 supplying and laying of xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 185 sqmm 3 core, suitable for 11 kv earthed system confirming to is 7098 part 2 for insulation and for conductors class 2 to is 8130 84, in trenches, floors, ducts passing through pipe forroad crossing etc, including connecting & testing and disconnecting and taking down of old unserviceable ht cable complete all as specified and directed.(note : excavation, earth work, brick protection, sand cushioning and gi pipe etc shall be measured & paid for separately). 32 material and labour for cable jointing kit for 11 kv (earthed) grade cable for straight through heatshrinkable type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 50 sqmm to 95 sqmm incl taking down old unsv ht joint complete all as specified and directed . 33 material and labour for cable jointing kit for 11 kv (earthed) grade cable for straight through heatshrinkable type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 120 sqmm to 185 sqmm incl taking down old unsv ht joint complete all as specified and directed . 34 m&l for cable end termination jointing kit ht 11 kv grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for ht xlpecable 50 95 sqmm 3 core 11 kv grade earthed system incl taking down old unsv ht joint complete all as specified and directed . 35 m&l for cable end termination jointing kit ht 11 kv grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for ht xlpecable 120 185 sqmm 3 core 11 kv grade earthed system incl taking down old unsv ht joint complete all as specified and directed . 36 taking down old unserviciable board and supply and fixing of retro reflective sign board of size 600 x 750 sqmm made of acp sheet of 3mm thick acp sheet shall be fixed on ms frame with legs of ms angle section 40mm x 40mm x 5mm grouted in pcc 1:3:6 type c 1, 750mm above the ground level and 600mm below the ground level. the background of board to be provided with red colour, letters and border with white retro reflective tape. same description shall be mentioned on both sides of acp sheet complete all as specified and directed.note: (i) excavation, earth work, pcc, nuts, bolts, fasners, paint on ms frame and legs shall be included in quoted rates by contractor.(ii) the size of letters and description shall be all as per sample approved by engr in charge. 37 material and labour for cable route indicator showing mes ht ug 11 kv and route of cable with arrow (should be embossed or engraved) made of rcc in suitable shape and fixed in pcc block 1:3:6 type c 2 using 40mm graded aggregate) 60cm xz 30cm in ground, 30cm below ground level and 30cm above ground level to show clear indication of cable including painting the complete slab with red paint and making the engraved/embossed letters/arrows with white paint, complete all as specified and as directed. 38 material and labour for shifting heavy items /excavating /cleaning areas /clearing site by providing crane/hydra/excavators as required at site complete all as specified and as directed. 39 material and labour for for loose filling in substations, under poles, under transformers of hard core broken to gauge not exc 63 mm broken stone/boulders including leveling and spreading lime stone powder under stones complete all as specified and as directed. 40 material and labour for prepration of old concrete surface of ht poles, 11 metres high including pcc coping, removing old paint particles and apply two coats of cement base paint on the surface of pole and pcc coping, applying two coat of aluminium paint on cross arms, bracing, supports, clamps, eye hooks, security light bracket clamp etc and marking black and white strips with synthetic enamel paint, 30 cm wide, alternatively upto 1.5 mtr above the coping of pole starting with black strip complete, all as specified and directed.note.(i)the quoted rate shall include marking of numbers on each ht pole as per direction of engr in charge.(ii)the quoted rates includes the cost of repairing of coping in cement mortar 1:3 finishing surfaces even and smooth without using extra cement. 41 material and labour for prepration of old steel surface of htpoles, 11 metres high including pcc coping, removing old paint particles and apply two coats of synthetic paint on the surface of pole and two coat of cement base paint on surface of pcc coping, applying two coat of aluminium paint on cross arms, bracing, supports, clamps, eye hooks, security light bracket clamp etc and marking black and white strips with synthetic enamel paint, 30 cm wide, alternatively upto 1.5 metre above the copping of pole starting with black strip complete, all as specified and directed.note.(i)the quoted rate shall include marking of numbers on each ht pole as per direction of engr in charge.(ii)the quoted rate include the cost of repairing of coping in cement mortar 1:3 finishing surfaces even and smooth without using extra cement. 42 supplying and laying in replacement of synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 kv forlectrical purpose as per is 15652 2006, (superseding is 5424) suitable for electrical shock safety of sizes 10m x 1m complete all as specified and diercted. 43 calibration of vcbs relay by injecting high voltage through cts checking the over load system of vcb upto 90% rated load and artificial fault creation and setting of relay by 10 to 15% of rated load removing unseviceable overload and earth fault relay including connections with power pack, opening out the trolley, checking the operation of vcb mechanically and electrically through shunt trip coil includng energizing of automatically, checking of tnc switch including testing and commissioning complete all as specified and directed.note : calibration to be carried out by authorised person and test certificate shall be furnished 44 taking out the ht 11 kv metalclad vaccum circuit breaker of capacity 630a/1250 a, 11000 volts,3 ph, 50 hz, 350 mva of any make and type from the cubical panel, for repairs/overhauling and servicing including replacement of wornout parts comprising the following works (a) removing the complete fixed contacts, moving contacts, cleaninig the contacts, removing the fittings and fixing back to the breakers after adjusting the pressure.(b) checking charging motor, motor relay, anti pump relay of the breaker, lubricate and align properly for smooth and perfect operation. (c) check and service the operating mechanism closing mechanism, and tripping mechanism including spring pressure, position etc. the labour charges are deemed to be included in the quoted unit rate for this item.note (i) servicing shall be performed by authorised service personnel of oem i.e m/s abb/seimens. (ii) servicing certficate shall be provided to engineer in charge. (iii) replacement of minor spares like push button lever, green push button, red push buttons and shaft for operating handles etc. are inclusive of rate quoted by tenderer (iv) measurment of resistance value, tools, labour, petroleum jelly are incl in this quoted rates (v) part will be replaced under relevent items. 45 material and labour for highly ht insulating opaque red coloured anti track compound spray 320 of mosil lubicants that forms flexible chemical resistant coating to class h winding for electrical apparatus, in 500 ml spray bottles to protect ht equipments, bus bar, cts, pts from current leakage due to moisture complete all as specified and as directed. 46 material and labour for danment chemical spray (dc>2.26 having container 415ml/300g) for precision blended multipurpose product to protect ht equipments from corrosion due to moisture complete all as specified and as directed.make : danmet chemical pvt ltd or equivalent as specified. 47 material and labour for spraying chemical (roundup) on area to remove unwanted vegitation/ grass at various locations as directed by engr in chargenote : (i)labour and equipments required to spray chemical on required area are included in the quoted rates. (ii)spray shall be repeated quarterly all as per directionof engr in charge 48 supply and fixing in replacement of pole assembly (vacuum interrupter bottle assembly) complete breaker of abb suitable for fixing in sector b substationcomplete all as specified and directed. 49 supply and fixing in replacement of vacuum interrupter pulling rod suitable for abb/siemens suitable breaker for existing model for fixing in 66kv/11kv substations complete all as specified and directed. 50 supply and fixing in replacement of unserviceable spout of vcb panel for suitable model fromht panel abb/seimens of 11 kv substations complete, all as specified and as directed. 51 supply and fixing in replacement of unserviceable spout contant of vcb panel for suitable model fromht panel abb/seimens of 11 kv substations complete, all as specified and as directed. 52 supply and fixing in replacement ofhousing of pole assembly for abb/seimens suitable model breaker from ht panel of 11 kv substations, complete all as specified and directed. 53 supply and fixing in replacementof unserviceable strip heaters 100 watt, ac 240 volts from ht panel of 11 kv substations complete all as specified and directed. 54 supply and fixing in replacement of unserviceable thermostat from ht panel of 11 kv substations complete all as specified and directed. 55 supply and fixing in replacement of unserviceable strip heaters 80 watt from ht panel of 11 kv substations complete all as specified and directed. 56 supply and fixing in replacement of unserviceable indicator with complete wiring of red/green/yellow colour from ht panel of 11 kv substations complete all as specified and as directed. 57 supply and fixing in replacement potential transformer (pt) of rating 11000/110v size and model as suitable for existing pts installed at 11 kv substations including re wiring and testing complete all as specified and directed. 58 supply and fixing in replacement current transformer of rating 500 250/5a of size and model as suitable for existing pts installed at 11 kv sub stations including re wiring and testing complete, all as specified and directed. 59 supply and fixing in replacement current transformer of rating 200 100/5a of size and model as suitable for existing pts installed at 11 kv sub stations including re wiring and testing complete all as specified and directed. 60 supply and fixing in replacement of shunt closing release coil 24 v/110v dc/ac suitable for 12 kv 1250 a 31.5 ka vcbs for suitable model of make abb//seimens/schneidercomplete all as specified and directed. 61 supply and fixing in replacement of geared motor (el)220 250 v ac/dc suitable for 12 kv 1250 a 31.5 ka vcbs for suitable model of make abb//seimens/schneider complete all as specified and directed. 62 supply and fixing in replacement of unserviceable limit switch for spring charging motor for suitable model of make abb//seimens/schneider ht panel of 11 kv substations complete all as specified and as directed. 63 supply and fixing in replacement of tripping coil 24 volt dc suitable for 12 kv 1250 a 31.5 kavcbs for suitable model of make abb//seimens/schneider complete all as specified and directed. 64 supply and fixing in replacement of racking mechanism to restrict uncessary blocking of trolley arrangement for suitable model of abb/siemens breaker complete all as specified and directed. 65 supply and fixing in replacement of tulip contacts 08/12 fingers of circuit breaker for suitable model of abb/siemens circuit breaker complete all as specified and directed. 66 supply and fixing in replacement of tnc switch for vcbs at different 11 kv substations complete all as specified and directed. 67 supply and fixing in repair pt fuse of capacity 11 kv suitable to fit on existing pts in 11 kv incommer vcbs at varioussubstations under ge (u) ambala complete all as specified and directed. 68 supply and fixing in replacement of combined overcurrent and earth fault relay rej601/7sr1205 of make abb/siemens including fixing in ht panels at66 kv mrs and 11 kv substations with connections as per company diagram from oem complete all as specified and as directed. 69 supply and fixing in replacement of master tripping relay of auxillary voltage 24 v/110 v ac/dc of make abb//seimens/schneider including fixing in ht panels at 11 kv substations with connections as per company diagram from oem complete all as specified and as directed. 70 supply and fixing in replacement of supervision relay of make abb/siemens including fixing in ht panels at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed. 71 supply and fixing in replacement ofauxiliarycontact suitable for make abb//seimens incl fixing in ht panels at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed by engr in charge. 72 supply and fixing in replacement ofdigital type ammeter with 1.0 accuracy class (+)1% of full scale 1 count 0 to 300 amps, stranded voltage burden 0.25 va max/phase working on ac auxillary supply voltage 230 volts, sencing ct 5 amps flush mounted type of size 96mm x 96mm x 75mm suitable for make abb//seimens vcbs complete all as specified and directed. 73 supply and fixing in replacement of digital type voltmeter to measure ac voltage 0 to 500 volts with 1.0 accuracy class, stranded voltage burden 0.25 va max/phase working on ac auxillary supply voltage 230 volts,flush mounted type of size 96mm x 96mm x 75mm suitable for make abb//seimens vcbs complete all as specified and directed. 74 supply and fixing in replacement of busbar insulatorin ht panels at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed by engr in charge. make abb//seimens/schneider 75 supply and fixing in replacement pvc unsheathed multi stranded copper cable (fr lsh) 1.5 sqmm nominal cross sectional area 1100 volts conforming to is 694 including electrical connection suitable size of lugs,nuts and bolts in vcbs complete all as specified and directed. 76 supply and fixing in replacement pvc unsheathed multi stranded copper cable (fr lsh) 2.5 sqmm nominal cross sectional area 1100 volts conforming to is 694 including electrical connection suitable size of lugs,nuts and bolts in vcbs complete all as specified and directed. 77 supply and fixing inreplacement copper terminals (thimbles) utype after cutting the worn out/faulty cable end suitable forvcbcontrol wiring 1.5/2.5 sqmmincluding crimping with crimping tools all as specified and directed. 78 supply and fixing inreplacement copper terminals (thimbles) pintype after cutting the worn out/faulty cable end suitable forvcbcontrol wiring 1.5/2.5 sqmmincluding crimping with crimping tools all as specified and directed. 79 supply and fixing inreplacementpower pack with battery backup input230 volt ac and out put 110 volt dc, 1a suitable for existingmake alan model no app 230110 sns invcbs abb/seimens complete allas specified and directed. 80 supply and fixing inreplacementdoor locksuitable for existingmakevcbs abb/seimens complete allas specified and directed. 81 taking down of ht rmu after disconnecting ht supply and reinstalled the same after repairing, servicing and testing of ht rmu and breakers, removing moisture and dust from ht bus bar and from inside of rmu panel of 11 kv substations complete all as specified and directed.note (i) the job shall be carried out through oem only. (ii)mesurement of (ir) resistance value tools, labour, petroleum jelly are included in this quoted rates.(iii) parts will be replaced under relevent items. 82 supply and fixing in replacement of combined over current and earth fault relay of make ashida model no adr141c or equivalent as specifiedincl fixing in rmu make abb at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed by engr in charge. 83 supply and fixing in replacement of pressure guage of rmu complete of make abb incl fixing in ht panels at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed by engr in charge. 84 supply and fixing in replacement of indicator with electric wiring complete of make abb incl fixing in rmu at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed by engr in charge. 85 supply and fixing in replacement of cable boot of make abb incl fixing in rmu at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed by engr in charge. 86 supply and fixing in replacement of bushing with o ring of make abb incl fixing in rmu at 11 kv sub stations with connections complete as per diagram from oem all as specified and directed by engr in charge. 87 supply and filling sf6 gas upto required level by using gas filling adopter including testing after completioncomplete all as specified and as directed. note: necassary filling kit shall be provided by contractor and quoted rates are deemed to be included for the same. 88 supply & fixing in replacement of rmu mechanismsuitable for existing model fo rmu make abbcomplete all as specified and directed. 89 supply and fixing in replacement push button red/green make abb incl fixing in rmu at 11 kv sub stations with connections completeall as specified and directed by engr in charge. 90 supply and fixing in replacement of tripping coil24 v dc suitable for existing rmu make abbcomplete all as specified and directed. 91 supply and fixing in replacement of geared motorsuitablefor existing rmu make abb complete all as specified and directed 92 s & f in replacement of unsv limit switch forgeared motorfor suitableexisting rmu make abbcomplete as per direction of engr in charge. 93 s&f in replacement of current transformer of rating 400 200/1a size and model as suitable as existing rmu of make abb complete all as specified and directed. 94 s&f in replacement of current transformer of rating 200 100/1a size and model as suitable as existing rmu of make abb complete all as specified and directed. 95 disconnecting the ht & lt connections and taking down of existing indoor/outdoor/canopy type transformer of capacity upto 200 kva mounted on 2/4 pole structure/plinth/substation and transport to factory from site/power house/ age e/m yard for repair and back to site/power house/ age e/m yard after necessary repair/replacement of defective parts including installation in the same location and testing, complete, all as specified and directed by engr in charge.note:(a)the rate quoted for the item includes thefollowing : (i)arrangement of manpower, tools , plants , crane and recovery vehicle fortransportation and shifting of transformerto work shop and back. (ii)toping up of transformer oil, replacement of transformer oil as required basis under intimation to the department. (transformer oil will be measured and paid seperately). (iii) re winding of defective winding of transformer, if required will be carried out under this item .(winding material shall be measured and paid separately under respective items) . (b)re winding of transformer and replacement of defective part will be carried out only after inspection of engineer in charge.( rewinding of transformer will be paid separately)(c)any damage occurred to transformer during the process of disconnecting/taking down/transportation, shall be made good by the contractor to the entire satisfaction of the eng in charge at his own expenses. 96 all as per serial item no 95.00 above but for transformer of capacity above 200 kva and upto 1000 kva complete all as specified and directed. 97 supply and fixing in replacement for non metal part hv bushingcomplete with packing for outdoor/indoor/canopy type of transformer of capacity upto 200 kva and for working pressure 11000 volts complete all as specified and as directed by engineer in charge. 98 supply and fixing in replacement for non metal part hv bushingcomplete with packing for outdoor/indoor/canopy type of transformer of capacity exceeding 200 kva but not exceeding 1000 kva and for working pressure 11000 volts complete all as specified and as directed by engineer in charge. 99 supply and fixing in replacement ht, brassbush rodof suitable size for outdoor/indoor/canopy type of transformer of capacity upto 200 kvacomplete all as specified and as directed by engr in charge. 100 supply and fixing in replacement ht, brassbush rodof suitable size for outdoor/indoor/canopy type of transformer of capacity exceeding 200 kva and upto 1000 kva, complete, all as specified and directed by engineer in charge. 101 supply and fixing in replacement for non metal part lv bushingwith packing for outdoor/indoor/canopy type of transformer of capacity upto 200 kva complete all as specified and as directed by engr in charge. 102 supply and fixing in replacement for non metal part lv bushingwith packing for outdoor/indoor/canopy type of transformer of capacity exceeding 200 kva and upto 1000 kva complete all as specified and as directed by engr in charge. 103 supply and fixing in replacement lt bush rod made of brass of suitable size for outdoor/indoor/canopy type of transformer of capacity upto 200 kva complete all as specified and as directed by engr in charge. 104 supply and fixing in replacement lt bush rod made of brass of suitable size for outdoor/indoor/canopy type of transformer of capacity exceeding 200 kva and upto 1000 kva, complete, all as specified and directed by engineer in charge. 105 supply and fixing in replacement top cover gasket of suitable size for outdoor/indoor/canopy type of transformer upto 1000 kva complete all as specified and as directed by engr in charge. 106 dismantling of old burnt tap changer and supply and fixing new tap changing switch as per existing size including making connection to transformer of various capacities/make complete all as specified and as directed by engr in charge. 107 supply and fixing in replacement 100 mm dia, temperature gauge including maximum temperature indicator complete all as specified and as directed by engr in charge. 108 material and labour for preparing surfaces of transformer of capacity up to 200 kva by rubbing old paint and applying two coats of spray painting with grey deco paintfrom outside, complete all as specified and as directed by engr in charge.note.painting of transformer will be carried out for plinth mounted and pole mounted transformer.necessary tools and plants shall be arranged by the contractor. 109 description all as per srl item no 108 hereinbefore but capacity of transformer exceeding 200 kva and upto 1000 kva , complete all as specified and as directed by engr in charge. 110 supply and fixing in replacement of gate valve with drain plug of suitable size for existig transformer, complete all as specified and as directed by engr in charge. 111 supply and fixing in replacement of conservator tank for step down distribution transformers of capacity upto 1000 kvacomplete all as per specification and direction of engr in charge. 112 supply and fixing in replacement of locking arrangement door with handle,hinges and door opennig system including welding, cutting, bending and riveting for compact sub station step down distribution transformers of capacity from 400 kva to 1000 kva complete all as per specification and direction of engr in charge. 113 material and labour forheating, filtration and dehydration of transformer oil as per is : 10028 (part iii) 1981, para 5.2 (obtained from transformer/servo voltage stabilizer switch under repair at workshop) with dehydration/ filtration plant to achieve dielectric strength of 40kv at4 mm gap, complete all as specified and as directed by engr in charge.note: any damage occurred to transformer during the process of dehydration, shall be made good by the contractor to the entire satisfaction of the engr in charge at his own expenses. 114 supply and pouring new transformer oil as per is : 335 (1993)for transformers installed at various site for topping up after dehydration to achieve the di electric strength 60 kv at 4 mm gap and topping up in the transformer under repair in workshop complete all as specified and as directed by engr in charge.note : transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of engr in charge, container shall be deposited by the contractor to the deptt, which will be returned after completion of conract. 115 material and labour for rewinding of hv side of copper wound transformer with super enameled winding wire as per relevant is, copper winding wire as per is : 1180 and and using original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer including taking down of old unserviceable copper winding wire complete all as specified and as directed . 116 material and labour for rewinding of hv side of copper wound transformer with dpc winding wire as per relevant is, copper winding wire as per is : 1180 and and using original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer including taking down of old unserviceable copper winding wire complete all as specified and as directed . 117 material and labour for rewinding of lv side of copper wound transformer with dpc winding stripas per relevant is, copper winding strip as per is : 1180 and using as per original gauge/dataincluding insulating materials such as cotton tape, packingand sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer including taking down of old unserviceable copper winding strip complete all as specified and as directed. 118 material and labour for rewinding of hv side of aluminium wound transformer with super enameled winding wire as per relevant is, aluminium winding wire as per is : 1180 and and using original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for aluminium wound transformer including taking down of old unserviceable aluminium winding wire complete all as specified and as directed . 119 material and labour for rewinding of hv side of aluminium wound transformer with dpc winding wire as per relevant is, aluminium winding wire as per is : 1180 and and using original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for aluminium wound transformer including taking down of old unserviceable aluminium winding wire complete all as specified and as directed . 120 material and labour for rewinding of lv side of aluminium wound transformer with dpc winding stripas per relevant is, aluminium winding strip as per is : 1180 and using as per original gauge/dataincluding insulating materials such as cotton tape, packingand sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for aluminium wound transformer including taking down of old unserviceable aluminium winding strip complete all as specified and as directed. 121 supply and fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity upto 200 kva complete all as per specification and direction of engr in charge. 122 supply and fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity from 200 kva to 1000 kva complete all as per specification and direction of engr in charge. 123 m&l for repairing the god mechanism pipe and handle lever, etc. by way of welding, greasing and including supply and fixing of new male and female contact complete all as specified and directed 124 surface dressing/cleaning of various 11 kv sub stations free from vegetation of any type including trimming of tree branches, bushes, creepers, etc. complete all as specified & directed.note: the frequency of surface dressing shall not be less than 2 months. 125 trimming of tree branches upto 75 mm dia to clear the route of ht/lt over head conductors in switch yards and open joints upto 3m from the 125 conductor including removing the cut branches from site and depositing at places n exc 50m all as directed by engineer in charge. note: (i) one/more tree branches covering 3m shall be considered as one unit. (ii) the frequency of trimming of tree branches shall not be less than 2 months. 126 note: amount of credit ofrs. 233722.50 for retrieved materials is mentioned in schedule of credit page no. 17 & 18 of tender documents in pdf form which will be deducted offline while acceptance of tender. ...

Dakshin Haryana Bijli Vitran Nigam Limited - Haryana

39571242 tender for site survey, planning, design, engineering, assembly manufacturing, testing, supply, loading, transportation, unloading, insurance, delivery at site, handling, storage, installation, testing, commissioning and documentation of all items/material required to complete the lrp works in the hisar no. i division (under hisar circle) which inter alia include replacement of lt bare conductor with lt armoured xlpe cable of various sizes, re conductoring of existing worn out lt line with new acsr conductor of various sizes in urban area, augmentation of existing 11 kv line with new acsr conductor / xlpe cable of various sizes, bifurcation of existing 11 kv feeders and installation of vcbs 1 pcc poles 9.0 m long. nos. 942 2500.00 412.50 2912.50 2743575.00 798.00 751716.00 3495291.00 2 pcc poles 9.0 m long. (for re conductoring of existing worn out lt line with new acsr conductor of various sizes) nos. 2277 2500.00 412.50 2912.50 6631762.50 379.05 863096.85 7494859.35 3 pcc poles 11.0 m long. nos. 1664 5343.00 881.60 6224.60 10357734.40 898.00 1494272.00 11852006.40 4 stay sets 8 long complete with x plat 460mm of angle 65x65x6 elbow & rod wt. 13.80 kg. set. 1626 1228.00 202.62 1430.62 2326188.12 299.00 486174.00 2812362.12 5 stay wire 7/8 swg kgs. 14886.300 99.12 16.35 115.47 1718921.06 0.00 0.00 1718921.06 6 gsl no.8 swg for (earthing & guarding) mtr. 153052 0.00 0.00 0.00 0.00 1.12 171418.24 171418.24 kgs. 19131.475 94.40 15.58 109.98 2104079.62 0.00 0.00 2104079.62 7a gi nuts bolts off sizes with washer kgs. 4962.650 84.00 13.86 97.86 485644.93 0.00 0.00 485644.93 part 1 bidding procedures and requirements 139 sr. no. description of material unit qty. of hisar no. i division (under hisar circle) unit supply rate including gst (inr) overhead charges i.e. 16.5% on supply part (incl. gst) total unit supply rate including gst and overhead charges total supply cost (inr) unit erection rate (inr) total erection cost (inr) total (supply + erection) cost (inr) 7b gi nuts bolts off sizes with washer (for re conductoring of existing worn out lt line with new acsr conductor of various sizes) kgs. 5690.525 84.00 13.86 97.86 556874.78 7.00 39833.68 596708.45 8 half clamps wt. 1.47 kg. hvpn drg. no. 2380 nos. 2033 156.00 25.74 181.74 369477.42 0.00 0.00 369477.42 9 full clamps wt.2.325 kg. hvpn drg. no. 2349 nos. 1626 247.00 40.76 287.76 467897.76 0.00 0.00 467897.76 10a lt insulator nos. 3766 10.00 1.65 11.65 43873.90 0.00 0.00 43873.90 10b lt insulator (for reconductoring of existing worn out lt line with new acsr conductor of various sizes) nos. 28453 10.00 1.65 11.65 331477.45 1.00 28453.00 359930.45 11 egg/guy insulator nos. 270 10.00 1.65 11.65 3145.50 0.00 0.00 3145.50 12a d straps nos. 3766 68.00 11.22 79.22 298342.52 0.00 0.00 298342.52 12b d straps (for reconductoring of existing worn out lt line with new acsr conductor of various sizes) nos. 28453 68.00 11.22 79.22 2254046.66 9.00 256077.00 2510123.66 13 wooden cleats (2holes) nos. 0 69.45 11.46 80.91 0.00 0.00 0.00 0.00 part 1 bidding procedures and requirements 140 sr. no. description of material unit qty. of hisar no. i division (under hisar circle) unit supply rate including gst (inr) overhead charges i.e. 16.5% on supply part (incl. gst) total unit supply rate including gst and overhead charges total supply cost (inr) unit erection rate (inr) total erection cost (inr) total (supply + erection) cost (inr) 14 4 core 120mm2 lt armoured xlpe cable kms. 0.000 644180.00 106289.70 750469.70 0.00 21130.00 0.00 0.00 15 4 core 95mm2 lt armoured xlpe cable kms. 0.000 394042.00 65016.93 459058.93 0.00 17610.00 0.00 0.00 16 4 core 50mm2 lt armoured xlpe cable kms. 0.000 239375.00 39496.88 278871.88 0.00 12300.00 0.00 0.00 17 4 core 25mm2 lt armoured xlpe cable kms. 0.000 144258.00 23802.57 168060.57 0.00 12300.00 0.00 0.00 18 3.5 core 120mm2 lt armoured xlpe cable kms. 0.000 449000.00 74085.00 523085.00 0.00 21130.00 0.00 0.00 19 3.5 core 95mm2 lt armoured xlpe cable kms. 0.000 400363.00 66059.90 466422.90 0.00 17610.00 0.00 0.00 20 3.5 core 50mm2 lt armoured xlpe cable kms. 0.000 245401.00 40491.17 285892.17 0.00 12300.00 0.00 0.00 21 1 core 120mm2 lt armoured xlpe cable kms. 0.000 169117.00 27904.31 197021.31 0.00 8455.85 0.00 0.00 22 1 core 95mm2 lt armoured xlpe cable kms. 103.344 105385.00 17388.53 122773.53 12687907.68 7830.00 809183.52 13497091.20 23 1 core 50mm2 lt armoured xlpe cable kms. 13.489 82315.00 13581.98 95896.98 1293554.36 5590.00 75403.51 1368957.87 24 1 core 25mm2 lt armoured xlpe cable kms. 0.000 52778.00 8708.37 61486.37 0.00 2880.00 0.00 0.00 part 1 bidding procedures and requirements 141 sr. no. description of material unit qty. of hisar no. i division (under hisar circle) unit supply rate including gst (inr) overhead charges i.e. 16.5% on supply part (incl. gst) total unit supply rate including gst and overhead charges total supply cost (inr) unit erection rate (inr) total erection cost (inr) total (supply + erection) cost (inr) 25 11 kv xlpe cable 3cx185mm2 kms. 0.000 1192638.00 196785.27 1389423.27 0.00 33540.00 0.00 0.00 26 11 kv xlpe cable 3cx95mm2 kms. 0.000 871349.00 143772.59 1015121.59 0.00 26830.00 0.00 0.00 27 11 kv xlpe cable 3cx50mm2 kms. 0.000 612948.00 101136.42 714084.42 0.00 22360.00 0.00 0.00 28 acsr dog conductor (100 sqmm) kms. 1133.124 86598.00 14288.67 100886.67 114317107.06 3350.00 3795965.40 118113072.46 29 acsr raccoon conductor (80 sqmm) kms. 0.000 63732.00 10515.78 74247.78 0.00 2520.00 0.00 0.00 30 insulated acsr raccoon conductor (80 sqmm) kms. 0.000 73732.00 12165.78 85897.78 0.00 2520.00 0.00 0.00 31 acsr rabbit conductor (50 sqmm) kms. 0.000 45611.00 7525.82 53136.82 0.00 2070.00 0.00 0.00 32 g.i. channel for wooden cleat (5 kg) 75x40x6mm. nos. 0 524.26 86.50 610.76 0.00 0.00 0.00 0.00 33 ss strap with adjustable screw (for clamping of armour for 25, 50, 95,120 mm2 & support gsl/jubliee clamp nos. 0 15.00 2.48 17.48 0.00 1.00 0.00 0.00 34 ms angle iron for bracing (600mm) 50x50x6mm wt. 2.70 kg. nos. 0 279.44 46.11 325.55 0.00 0.00 0.00 0.00 35 mid span joint (120sq mm). nos. 0 140.00 23.10 163.10 0.00 9.00 0.00 0.00 36 mid span joint (95sq mm). nos. 191 135.00 22.28 157.28 30040.48 8.00 1528.00 31568.48 37 mid span joint (70sq mm). nos. 0 127.00 20.96 147.96 0.00 7.50 0.00 0.00 38 mid span joint (50sq mm). nos. 25 123.00 20.30 143.30 3582.50 7.00 175.00 3757.50 39 mid span joint (25sq mm). nos. 0 118.00 19.47 137.47 0.00 7.00 0.00 0.00 40 gi pipe for earthing of dt 40mm dia 6 mtr long. nos. 749 1901.00 313.67 2214.67 1658787.83 320.32 239919.68 1898707.51 41 gi strip 25x6 9 mtr long 10.8 kg. nos. 749 1148.00 189.42 1337.42 1001727.58 82.00 61418.00 1063145.58 42 earth chemical (coal + salt 3.75 kg each). kgs. 1908.871 13.88 2.29 16.17 30866.44 0.00 0.00 30866.44 43 al. lugs offsize. (120 sqmm) nos. 0 11.90 1.96 13.86 0.00 5.00 0.00 0.00 44 al. lugs offsize. (95 sqmm) nos. 0 10.00 1.65 11.65 0.00 5.00 0.00 0.00 45 insulating piercing connector (50 150 sq.mm) nos. 7370 85.00 14.03 99.03 729851.10 6.00 44220.00 774071.10 part 1 bidding procedures and requirements 143 sr. no. description of material unit qty. of hisar no. i division (under hisar circle) unit supply rate including gst (inr) overhead charges i.e. 16.5% on supply part (incl. gst) total unit supply rate including gst and overhead charges total supply cost (inr) unit erection rate (inr) total erection cost (inr) total (supply + erection) cost (inr) 46 insulating piercing connector (16 95/4 50 sq.mm) nos. 0 72.00 11.88 83.88 0.00 5.00 0.00 0.00 47 eye screw bolts 9”x5/8 wt. 0.483 kg. (g.i) nos. 941 41.00 6.77 47.77 44951.57 0.00 0.00 44951.57 48 insulation mastic tape (2inc x 10 feet). nos. 620 793.00 130.85 923.85 572787.00 48.00 29760.00 602547.00 49 11kv top hamper g.i. weight 1.480 kg nos. 1048 157.00 25.91 182.91 191689.68 0.00 191689.68 50 11kv polymeric pin insulator with pin nos. 3696 189.00 31.19 220.19 813822.24 0.00 813822.24 51 11 kv polymeric disc insulator (45 kn.tounge & clevis type) with fitting nos. 1109 116.00 19.14 135.14 149870.26 0.00 149870.26 52 disc fitting t&c type nos. 0 87.00 14.36 101.36 0.00 0.00 0.00 0.00 53 pg clamp nos. 1109 40.00 6.60 46.60 51679.40 0.00 51679.40 54 v shape x arm g.i. 100x50 mm ( ismc 100) weight 13.2 kg nos. 1048 1365.00 225.23 1590.23 1666561.04 0.00 1666561.04 55 11 kv disc insulator (t&c type) for stay nos. 1356 116.00 19.14 135.14 183249.84 0.00 183249.84 part 1 bidding procedures and requirements 144 sr. no. description of material unit qty. of hisar no. i division (under hisar circle) unit supply rate including gst (inr) overhead charges i.e. 16.5% on supply part (incl. gst) total unit supply rate including gst and overhead charges total supply cost (inr) unit erection rate (inr) total erection cost (inr) total (supply + erection) cost (inr) 56 earthing rod weight 6.175 kg nos. 124 434.00 71.61 505.61 62695.64 151.00 18724.00 81419.64 57 m.s. channel (x arm) 100x50x6mm 2200mm (for h pole) g.i. wt. 21.032 kg nos. 740 2175.00 358.88 2533.88 1875071.20 0.00 1875071.20 58 m.s.angle iron 50x50x6mm 2400mm (for earth wire) g.i. wt.10.80 kg nos. 432 1118.00 184.47 1302.47 562667.04 0.00 562667.04 59 m.s. angle 50x50x6mm 2860mm (bracing h. pole) g.i. wt. 12.87 kg nos. 493 1332.00 219.78 1551.78 765027.54 0.00 765027.54 60 m.s angle 50x50x6mm 2200mm (belting for hpole) g.i. wt. 9.90 kg nos. 493 1025.00 169.13 1194.13 588706.09 0.00 588706.09 61 barbed wire kgs. 1478.400 97.94 16.16 114.10 168685.44 0.00 168685.44 62 danger plate(enamelled with clamp) nos. 1664 68.00 11.22 79.22 131822.08 0.00 131822.08 63 number plate with clamp nos. 1294 68.00 11.22 79.22 102510.68 0.00 102510.68 64 phase plate for each phase set of 3 (on each h pole) set. 308 57.00 9.41 66.41 20454.28 0.00 20454.28 65 gi angle 50x50x6 mm 1400 mm long kgs. 7022.400 86.45 14.26 100.71 707225.90 0.00 707225.90 66 knee bracing (gi flat 50x6mm) kgs. 4928.000 89.21 14.72 103.93 512167.04 0.00 512167.04 part 1 bidding procedures and requirements 145 sr. no. description of material unit qty. of hisar no. i division (under hisar circle) unit supply rate including gst (inr) overhead charges i.e. 16.5% on supply part (incl. gst) total unit supply rate including gst and overhead charges total supply cost (inr) unit erection rate (inr) total erection cost (inr) total (supply + erection) cost (inr) 67 g.i. channel t off 100x50x6 mm 1600mm). wt. 15.296kg nos. 0 1582.00 261.03 1843.03 0.00 0.00 0.00 0.00 68 ht 11kv xlpe 3c x185 sq. mm outdoor heat shrinkable termination kit nos. 0 985.00 162.53 1147.53 0.00 98.50 0.00 0.00 69 ht 11kv xlpe 3c x95 sq. mm outdoor heat shrinkable termination kit nos. 0 825.00 136.13 961.13 0.00 82.50 0.00 0.00 70 ht 11kv xlpe 3c x50 sq. mm outdoor heat shrinkable termination kit nos. 0 775.00 127.88 902.88 0.00 77.50 0.00 0.00 71 suspension clamp assembly with eye hook nos. 0 425.00 70.13 495.13 0.00 0.00 0.00 0.00 72 dead end clamp assembly with eye hook set. 0 244.00 40.26 284.26 0.00 0.00 0.00 0.00 73 u bolt for suspension fittings wt 0.600 kg (gi) nos. 0 50.00 8.25 58.25 0.00 0.00 0.00 0.00 74 ss cable ties releaseable arc for dia 250mm nos. 0 6.00 0.99 6.99 0.00 0.39 0.00 0.00 75 ss cable ties releaseable arc for dia 250mm (for augmentation of existing 11 kv line with overhead xlpe cable of various sizes) nos. 0 6.00 0.99 6.99 0.00 0.00 0.00 0.00 76 gss wire (earth wire) 7/14 swg 2.24mm mtr. 0 0.00 0.00 0.00 1.62 0.00 0.00 kgs. 0.000 103.84 17.13 120.97 0.00 0.00 0.00 77 11kv vcb panel (outgoing 25ka , 475mv refnicng capacity , 24v dc operated indoor type with set of ct/,pts, kwh meter, relays instruments etc complete in all respets conforming to all nigams specifications iss (400a) set. 0 332000.00 54780.00 386780.00 0.00 6708.00 0.00 0.00 78 11kv vcb panel (outgoing), v dc operated indoor type with set of ct/,pts, kwh meter, relays instruments etc complete in all respets (1250a) set. 0 264083.00 43573.70 307656.70 0.00 6708.00 0.00 0.00 79 un armoured copper control cable 10c x 2.5 mm2 mtr. 0 278.76 46.00 324.75 0.00 18.00 0.00 0.00 80 gi flat 50 x 6 mm kgs. 0.000 89.21 14.72 103.93 0.00 5.00 0.00 0.00 81 3/cx185mm sq. i/d heat shrinkable cable box for o/g feeders nos. 0 840.00 138.60 978.60 0.00 84.00 0.00 0.00 part 1 bidding procedures and requirements 147 sr. no. description of material unit qty. of hisar no. i division (under hisar circle) unit supply rate including gst (inr) overhead charges i.e. 16.5% on supply part (incl. gst) total unit supply rate including gst and overhead charges total supply cost (inr) unit erection rate (inr) total erection cost (inr) total (supply + erection) cost (inr) 82 signboard (as per clause 1.7 of sbd part 2 – sow) actual qty. and supply / erection rates will be circulated separately nos. total 1 171618110.62 9167337.88 180785448.49 details of materials (approx.) to be dismantled 1 poles (off sizes) nos. 860 0.00 0.00 0.00 0.00 189.53 162995.80 162995.80 2 old acsr conductor (off sizes) km. 763.548 0.00 0.00 0.00 0.00 615.00 469582.02 469582.02 3 steel items kg. 7297.860 0.00 0.00 0.00 0.00 2.50 18244.65 18244.65 4 lt cable (off sizes) km. 0.270 0.00 0.00 0.00 0.00 6150.00 1660.50 1660.50 5 ht cable (off sizes) km. 0.000 0.00 0.00 0.00 0.00 11180.00 0.00 0.00 total 2 0.00 652482.97 652482.97 grand total (total 1 + total 2) 171618110.62 9819820.85 181437931.46...

Chaudhary Ranbir Singh University - Haryana

39299694 supply, installation, testing and commissioning of 11 kv vcb panel with 1 incomer 5 outgoing and re installation of rmu at chaudhary ranbir singh university, jind...

Irrigation Department - Haryana

39275541 estimate for supply erection and commissioning of electromechanical equipments like vt pumps, electric motors, ltdb panel with cable, m.s. girder, grating, trash rack and other allied accessories and accessories at rd 28000 gujrani pump house , supply, erection and commissioning of 40 cs. v.t. axial flow pumps of 980 rpm, having static lift as per site requirement, 90 degree/ y bodyincludingms delivery pipe as per actual site requirement and ms delivery bends of minimum 8 mm thickness with bituminous based paint inside & outside,flange welded, ht nut bolts, siphon breaker valve and any other left over item duly painted inner and outer sidecomplete in all respect, as per site requirement and as per approved technical specifications. (for gujrani mr. ph at rd 28000). , supply, erection and commissioning of solid shaft motor of capacity 150 hp, 980 rpm, 3 phase 415 volt + 10% , 50 hzwith efficiency class ie2 (as per is 12615 with latest amendments) suitable for 40 cs. vt axial flow pumps with 6 feet lift type vertical flange mounted & as per approved technical specification with earthing of motor complete in all respect as per site requirement. (for gujrani mr. ph at rd 28000). , supply, erection and commissioning of ltdb panel of 1250 amp. capacity with all accessories as one incomer acb 1250 amp. with 3 no. outgoing each of having mccb of 400 amp. along with an addl. mccb of 100 amp. for lighting loads, indicators, relay, meters, push buttons, bus bars and with 4 no. fully automatic ats starters (completed in all respect like relays, indicators timer etc.). of 150 hp motors each with mccb of 400 amp.with contactor rating as 400,300 ,200 amp. with first filling of oil (if oil cooled ats used) starter with designed capacitor bank of 200 kvar capacity with 8 step apfcr, digital display instruments & other allied accessories for automatic as well as manual operation of capacitor bank suitable for 3 nos. 150 hp motors. each stage should have separate protection through mccb. one no. incomer mccb of 400 amps to be provided for capacitor bank. the ltdb should be as per approved design of hid at annexure c. with a stand of ms channel duly painted (1.5 ft. up from floor) & as per approved technical specification with earthing.(for gujrani mr. ph at rd 28000). , supply, erection and commissioning of ltdb panel of 1250 amp. capacity with all accessories as one incomer acb 1250 amp. with 4 no. outgoing each of having mccb of 400amp. along with an addl. mccb of 100 amp. for lighting loads, indicators, relay, meters, push buttons, bus bars and with 4 no. fully automatic ats starters (completed in all respect like relays, indicators timer etc.). of 150 hp motors each with mccb of 400 amp.with contactor rating as 400,300 ,200,100 amp. with first filling of oil (if oil cooled ats used) starter with designed capacitor bank of 250 kvar capacity with 8 step apfcr, digital display instruments & other allied accessories for automatic as well as manual operation of capacitor bank suitable for 4 nos. 150 hp motors. each stage should have separate protection through mccb. one no. incomer mccb of 400 amps to be provided for capacitor bank. the ltdb should be as per approved design of hid at annexure c. with a stand of ms channel (1.5 ft. up from floor) & as per approved technical specification with earthing.(for gujrani mr. ph at rd 28000). , supply, erection and commissioning of lt armoured pvc aluminium cable of size 1000mmsq. single core core confirming to is 7098 1995 as per approved make with thimble, nut & bolt and other allied material and also laying of pvc cable included of all civil work & also dismantling of old cable. (for gujrani mr. ph at rd 28000). , supply, erection and commissioning oflt power cable – lt power cables 3 core x 185mm2copper conductorxlpe insulated, cores laid up, pvc inner sheathed, armored (galvanized steel strip), extruded pvc type st2 outer sheathed, 650 v/1100 v grade as per is 7098 with copper thimble, nut & bolt and other allied material completed in all respect (for gujrani mr. ph at rd 28000). , supply, erection and commissioning of ms girder make tata, jindal,sail – total 265 mtr(conforming to is 12778 : 2004) size ismb 350mm x 140 mm) (weight per kg/mtr. 52.4) with primer and bituminous based paint inside & outside.note : 1. removal of existing girders, vt axial flow pumps with motors and after commissioning of work again installation of the same (vt axial flow pumps with motors) & also welding workwill be complete by the agency in all respect withincludingall civil works (for gujrani mr. ph at rd 28000). , supply errection and laying down of grating (247.9 sq area of various sites)) (weight per kg/mtrsq. 46 )as per approvedmake tata, jindal,sail at pump base duly painted also including dismantaling of old one & also welding work completed in all respect , including all civil work required for proper fixing. (for gujrani mr. ph at rd 28000). , s/e/c of trash rackwith ms component duly dual painted as: 20 no. trash racks (different sizes according to sites ) each weighting 3 quintol each ms angle 50 x50 x 6 mm with spacing of 2.5 inch 35 x6 mm ms flat sizes as per various actual sites.(for gujrani mr. ph at rd 28000) , supply and erection of dg set of capacity 1000 kva with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus ( )1% volts ac alternator coupled directly through a set of flexible coupling on a common ms fabricated base frame with diesel engine complete with suitable size change over/amf panel, incoming cable from generator to change over/amf panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / std panel to incomer of motor starter panel, fenced enclosure with platform for dg sets complete as per following detailed scope and specifications and directions of engineer in charge. the rating should be at 1500 rpm. a) diesel engine b) alternator c) battery 24 v. d) base plate. e) suitable sq mm suitable core copper cable upto 40 metres. f) tools, standard panel g) metering set 415 vac 1 set (amp. meter, volt meter, ass, vss, phase indicator, control fuse, frequency meter, ct`s) h) metering set 60/5a/110v (amp. meter, volt meter) i) overload protection for dc 1 no. j) battery charger 24v dc k)copper bus bar of suitable size l) kwh meter 96 sqmm size m) starting fuse button and key switch9on/off) n) indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, dc control and other required accessories complete in all respects to the satisfaction of engineer in charge` as per site included of all civil work also and as per approved technical specifications. ( for gujrani mr. ph at rd 28000 ) , dry type cast resin voltage step down system ( x’mer, shunt capacitor bank with reactor 200 kvar, vcb panel i/o, 11 kv cable from pole to vcb panel & vcb to transformer, la (pole) with counter, la(line), foundation for xmer,chemical earthing (neutral = 2 nos. body = 2 nos., pole & go switch = 1 no., la = 2 nos. vcb panel = 2 nos.), stone pitching, fencing, laying of hdpe pipe for cables, go switch & termination kits) for 11/.433kv having capacity of 1.6 mva with transient voltage protection system to protect the x’mer against high voltage surges of make siemens / abb / schneider / ge. the scope also includes inspection by m&m/dhbvn at pump house ....

Irrigation Department - Haryana

39275540 estimate for supply erection and commissioning of elect. equipments like vt pumps, electric motors, ltdb panel with cable, m.s. girder, grating, trash rack and other allied accessories and accessories at various pump houses of nigana canal system , supply, erection and commissioning of 40 cs. v.t. axial flow pumps of 980 rpm, having static lift of 25 feet includingms delivery pipe with all flanges , y body as per actual site requirement and ms delivery bends of minimum 8 mm thickness with bituminous based paint inside & outside including flange welded, ht nut bolts, siphon breaker valve bell mouth and support of bend with any other left over item duly painted inner and outer sidecomplete in all respect, as per site included of all civil work also and as per approved technical specifications. (for ph no. 1 nigana canal &for ph no. 2 nigana canal). , supply, erection and commissioning of 35 cs. v.t. axial flow pumps of 980 rpm, having static lift of 25 feet includingms delivery pipe with all flanges , y body as per actual site requirement and ms delivery bends of minimum 8 mm thickness with bituminous based paint inside & outside including flange welded, ht nut bolts, siphon breaker valve bell mouth and support of bend with any other left over item duly painted inner and outer sidecomplete in all respect, as per site included of all civil work also and as per approved technical specifications. (for ph no. 1 nigana canal &ph no. 2 nigana canal). , supply, erection and commissioning of 10 cs. v.t. axial flow pumps of 1440 rpm, having static lift of 18 feet, including 2 nos. msdelivery pipe 6 meter each withall flanges , y body as per actual site requirement and ms delivery bends of minimum 8 mm thickness with bituminous based paint inside & outside including flange welded, ht nut bolts, siphon breaker valve bell mouth and support of bend with any other left over item duly painted inner and outer sidecomplete in all respect, as per site included of all civil work also and as per approved technical specifications.(for escape reservoir at n/f and ph 4 & 5 n/c). , supply, erection and commissioning of solid shaft motor of capacity 225 hp, 980 rpm, 3 phase 415 volt + 10% , 50 hz with efficiency class ie2 (as per is 12615 with latest amendments) suitable for 40 cs. vt axial flow pumps with 25 feet lift type vertical flange mounted & as per approved technical specification with earthing of motor. (for ph no. 1 nigana canal &ph no. 2 nigana canal). , supply, erection and commissioning of 5 cs. v.t. axial flow pumps of 1440 rpm, having static lift of 8.5 feet, including msdelivery pipe 6 meter each withall flanges , y body as per actual site requirement and ms delivery bends of minimum 8 mm thickness with bituminous based paint inside & outside including flange welded, ht nut bolts, siphon breaker valve bell mouth and support of bend with any other left over item duly painted inner and outer sidecomplete in all respect, as per site included of all civil work also and as per approved technical specifications.(for tosham hill ph and bhurtana mr. ph). , supply, erection and commissioning of solid shaft motor of capacity 200 hp, 980 rpm, 3 phase 415 volt+ 10% , 50 hz with efficiency class ie2 (as per is 12615 with latest amendments) suitable for 35 cs. vt axial flow pumps with 25 feet lift type vertical flange mounted & as per approved technical specification with earthing of motor. (for ph no. 1 nigana canal). , supply, erection and commissioning of solid shaft motor of capacity 60 hp, 1440 rpm, 3 phase 415 volt+ 10% , 50 hz with efficiency class ie2 (as per is 12615 with latest amendments) suitable for 10 cs. vt axial flow pumps with 18 feet lift type vertical flange mounted & as per approved technical specification with earthing of motor. (for escape reservoir at n/f & ph no. 4 &5 n/c). , supply, erection and commissioning of solid shaft motor of capacity 30 hp, 1440 rpm, 3 phase 415 volt+ 10% , 50 hz with efficiency class ie2 (as per is 12615 with latest amendments) suitable for 5 cs. vt axial flow pumps with 8.5 feet lift type vertical flange mounted & as per approved technical specification (for tosham hill pump house &for bhurtana minor pump house). , supply, erection and commissioning of mcc panel of 1600 amp. capacity with all accessories as one incomer acb 4 pole 1600 amp. with 4 no. outgoingeach of having mccb of 630 amp. alongwith an addl. mccb of 100 amp. for lighting loads, indicators, relay, meters, push buttons, bus bars to be connected with item at (9.1) with suitable capacitor bank 300 kvar with 8 stepapfcr, digital display instruments & other allied accessories for running of 4 nos. 225 hp motors. each stage should have protection through separate mccb as per approved design of ltdb panel with a stand of ms channel ( 1.5 ft. up from floor) & as per approved technical specification with earthing.(for ph no. 1& 2 nigana canal). , supply, erection and commissioning of fully automatic ats starter 225 hp (complete in all respect like relays, indicatos, timer etc) with suitable contactor rating with first filling of oil ( if oil cooled ats used). , supply, erection and commissioning of 60 hp fully automatic ats starter with mccb of 160 amp., 3 pole, 415 volt, 50 hz. with air breaker power contactors of 150 a/100a/65a with digital meter, motor protection relay, indicators etc. complete in all respect degree of protection ip 54 1/c connections and small items as thimbles, nut/bolts, lugs etc. with a stand of ms channel (1 feet up from floor level) as per sites requirement and as per technical specifications (for escape reserviour nigana feeder). , supply, erection and commissioning of ltdb panel of 250 amp. capacity with all accessories as one incomer acb 250 amp. with 3 no. outgoing each of having mccb of 100 amp. along with an addl. mccb of 63 amp. for lighting loads, indicators, relay, meters, push buttons, bus bars and with 3 no. fully automatic ats starters (completed in all respect like relays, indicators timer etc.). of 3 no. 30 hp motors each with mccb of 100 amp.with contactor rating as 70, 40, 25 amp. with first filling of oil (if oil cooled ats used) starter with designed capacitor bank of 30 kvar capacity with 8 step apfcr, digital display instruments & other allied accessories for automatic as well as manual operation of capacitor bank suitable for 3 nos. 30 hp motors. each stage should have separate protection through mccb. one no. incomer mccb of 100 amps to be provided for capacitor bank. the ltdb should be as per approved design of hid at annexure c. with a stand of ms channel (1.5 ft. up from floor) & as per approved technical specification with earthing.(for tosham hill and bhurtana pump house each). , supply, erection and commissioning oflt power cable – lt power cables 3 core x 185mm2copper conductorxlpe insulated, cores laid up, pvc inner sheathed, armored (galvanized steel strip), extruded pvc type st2 outer sheathed, 650 v/1100 v grade as per is 7098 with copper thimble, nut & bolt and other allied material completed in all respect (for various pump houses of nigana canal system) , supply of lt armoured pvc aluminium cable of size 630mmsq. 3 core core confirming to is 7098 1995 as per approved make and also laying of pvc cable included of all civil work & also dismantling of old cable. (for ph no. 1 nigana canal & (for ph no. 2 nigana canal). , supply of lt armoured pvc aluminium cable of size 120mmsq.3.5 core confirming to is 7098 1995 as per approved make and also laying of pvc cable included of all civil work & also dismantling of old cable. (for escape reservoir at n/f). , supply, erection and commissioning of ms girder make tata, jindal,sail – total 265 mtr(conforming to is 12778 : 2004) size ismb 350mm x 140 mm) (weight per kg/mtr. 52.4) with primer and bituminous based paint inside & outside.note : 1. removal of existing girders, vt axial flow pumps with motors and after commissioning of work again installation of the same (vt axial flow pumps with motors) & also welding workwill be complete by the agency in all respect withincludingall civil works (for various pump houses of nigana canal system , supply errection and laying down of grating (247.9 sq area of various sites)) (weight per kg/mtrsq. 46 )as per approvedmake tata, jindal,sail at pump base duly painted also including dismantaling of old one & also welding work completed in all respect , including all civil work required for proper fixing. (for various pump houses of nigana canal system) , s/e/c of trash rackwith ms component duly dual painted as: 55 no. trash racks (different sizes according to sites ) each weighting 3 quintol each ms angle 50 x50 x 6 mm with spacing of 2.5 inch 35 x6 mm ms flat sizes as per various actual sites. for ph no. 1,2,3,4,5,8,9 nigana canal & new sangwan ph) , dry type cast resin voltage step down system ( x’mer, shunt capacitor bank with reactor 200 kvar, vcb panel i/o, 11 kv cable from pole to vcb panel & vcb to transformer, la (pole) with counter, la(line), foundation for xmer,chemical earthing (neutral = 2 nos. body = 2 nos., pole & go switch = 1 no., la = 2 nos. vcb panel = 2 nos.), stone pitching, fencing, laying of hdpe pipe for cables, go switch & termination kits) for 11/.433kv having capacity of 1.6 mva with transient voltage protection system to protect the x’mer against high voltage surges of make siemens / abb / schneider / ge. the scope also includes inspection by m&m/dhbvn at pump house nigana. , supply, erection and commissioning of ms delivery pipe 258.9 mm inner dia. ( in approx. 6 meter per pipe) and each pipe of 8 mm thickness both ends welded with flange made ms plate as per approved specification including ht nut and bolts, rubber sheet andother fitmet accessories...

Irrigation Department - Haryana

39275535 estimate for supply, erection and commissioning of various electromechanical equipment like vt pump, electric motors, ltdb panel and other allied material at ph 1 to 5 jc , supply, erection and commissioning of 10 cs. v.t. axial flow pumps of 1440 rpm, having static lift of 13 feet, including 12 meter (6+6) delivery pipe as per actual site requirement and ms delivery bends of minimum 8 mm thickness with bituminous based paint inside & outside including flange welding, ht nut bolts, siphon breaker valve, complete in all respect, as per site and as per approved technical specifications. (for ph no. 1 j/c ). , supply, erection and commissioning of 5 cs. v.t. axial flow pumps of 1440 rpm, having static lift of 13 feet, including delivery pipe as per actual site requirement and ms delivery bends of minimum 8 mm thickness with bituminous based paint inside & outside including flange welding, nut bolts, siphon breaker valve, complete in all respect, as per site and as per approved technical specifications (for ph no. 1,2,3 j/c) , supply, erection and commissioning of 20 cs. v.t. axial flow pumps of 970 rpm, having static lift 13 feet, including delivery pipe as per actual site requirement and ms delivery bends of minimum 8 mm thickness with bituminous based paint inside & outside including flange welding, nut bolts, siphon breaker valve, complete in all respect, as per site and as per approved technical specifications (for ph no. 1 jui canal ) , supply, erection and commissioning of solid shaft motor of capacity 50 hp of 4 pole, 1440 rpm, 3 phase 415 volt with efficiency class ie2 (as per is 12615 with latest amendments) suitable for 10 cs. vt axial flow pumps with 13 feet lift type vertical flange mounted & as per approved technical specification with earthing of motor (ph 1 j/c). , supply, erection and commissioning of solid shaft motor of capacity 30 hp of 4 pole, 1440 rpm, 3 phase 415 volt with efficiency class ie2 (as per is 12615 with latest amendments) suitable for 5 cs vt axial flow pumps with 13 feet lift type vertical flange mounted & as per approved technical specification with earthing of motor (for ph 1,2,3 j/c) , supply, erection and commissioning of solid shaft motor of capacity 100 hp of 6 pole, 970 rpm, 3 phase 415 volt with efficiency class ie2 (as per is 12615 with latest amendments) suitable for 20 cs vt axial flow pumps with 13 feet lift type vertical flange mounted & as per approved technical specification with earthing of motor (for ph no. 1 jui canal ). , supply, erection and commissioning of 50hp fully automatic ats starter with mccb of 250 amp. capacity with all accessories along with an addl. mccb of 63 amp. for lighting loads, indicators, relay, meters, push buttons, bus bars, timers etc. with contactor rating as 110, 80, 50 amp. with first filling of oil (if oil cooled ats used) starter should have individual capacitor bank of 25 kvar capacity coupled through 63 amp. mccb and timer with digital display instruments & other allied accessories for automatic as well as manual operation, complete in all respect with a stand of ms channel (1feet up from floor) with latest amendments suitable for 10 cs. axial flow pumps and as per approved technical specifications with earthing. (for ph 1 j/c) , supply, erection and commissioning of 30hp fully automatic ats starter with mccb of 160 amp. capacity with all accessories along with an addl. mccb of 63 amp. for lighting loads, indicators, relay, meters, push buttons, bus bars, timers etc. with contactor rating as 110, 80, 40 amp. with first filling of oil (if oil cooled ats used) starter should have individual capacitor bank of 16 kvar capacity coupled through 63 amp. mccb and timer with digital display instruments & other allied accessories for automatic as well as manual operation, complete in all respect with a stand of ms channel (1feet up from floor) with latest amendments suitable for 5 cs. axial flow pumps and as per approved technical specifications with earthing(for ph no. 1,2,3 jui canal) , supply, erection and commissioning of 100 hp fully 1 no. automatic ats starter with a mccb of 400 amp. with main contactor of 300 amp., tapping contactor of 200 amp and star of 110 amp for 100 hp motor with ats with degree of protection ip 54 including connection and items as suitable capacitor bank, bush bar, push button, relays, meter, thimbles, nut/bolt, lugs, etc. complete in all respect with a stand of ms channel (1feet up from floor) with latest amendments suitable for 20 cs. axial flow pumps and as per approved technical specifications. (for ph no. 1 jui canal ). , supply, erection and commissioning of 225 hp fully automatic ats starter with mccb of 630 amp. capacity with all accessories along with an addl. mccb of 100 amp. for lighting loads, indicators, relay, meters, push buttons, bus bars, timers etc. with contactor rating as 550,400, 300 amp. with first filling of oil (if oil cooled ats used) starter should have individual capacitor bank of 100 kvar capacity coupled through 100 amp. mccb and timer with digital display instruments & other allied accessories for automatic as well as manual operation, complete in all respect with a stand of ms channel (1feet up from floor) with latest amendments suitable for 50 cs. axial flow pumps and as per approved technical specifications with earthing. (for ph no. 1, 2 j/c ). , supply, erection and commissioning of mcc panel of 1600 amp. capacity with all accessories as one incomer acb 4 pole 1600 amp. with 3 no. outgoingeach of having mccb of 630 amp. alongwith an addl. mccb of 100 amp. for lighting loads, indicators, relay, meters, push buttons, bus bars to be connected with item at 11(a) with suitable capacitor bank 300 kvar with 8 stepapfcr, digital display instruments & other allied accessories for running of 3 nos. 225 hp motors. each stage should have protection through separate mccb as per approved design of ltdb panel with a stand of ms channel ( 1.5 ft. up from floor) & as per approved technical specification with earthing. (for ph no. 3 jui canal) , fully automatic ats starters 225 hp (completed in all respect like relays, indicators timer etc.). with suitable contactors rating with first filling of oil (if oil cooled ats used) (for ph no. 3 jui canal) , supply, erection and commissioning of 50 cs. v.t. axial flow pumps of 585 rpm, having static lift 13 feet, including delivery pipe as per actual site requirement and ms delivery bends of minimum 8 mm thickness with bituminous based paint inside & outside including flange welding, nut bolts, siphon breaker valve, complete in all respect, as per site and as per approved technical specifications (for ph no. 3 jui canal ). , dry type cast resin voltage step down system ( x’mer, shunt capacitor bank with reactor 200 kvar, vcb panel i/o, 11 kv cable from pole to vcb panel & vcb to transformer, la (pole) with counter, la(line), foundation for xmer, chemical earthing (neutral = 2 nos. body = 2 nos., pole & go switch = 1 no., la = 3 nos. vcb panel = 2 nos.), stone pitching, fencing, laying of hdpe pipe for cables, go switch & termination kits) for 11/.433kv having capacity of 1.6 mva with transient voltage protection system to protect the x’mer against high voltage surges of make siemens / abb / schneider / ge. the scope also includes inspection by m&m/dhbvn. (for ph no. 1, 2 j/c ). , supply, erection and commissioning of ms components duly painting including any kind of civil work for various sites as: a.)trash rack of size as per actual site requirement made of 50x50x6mm ms angle& 50x6 mm ms flat each at 2” apart. b.) ms grating of size as per actual site requirement made of 40x40x5 mm ms angle & 35x5 mm ms flat each 2” apart. c.) ms 3” solid pipe (horizontal) both end hinged one end to ph wall and other to other end of ms pipe 3” (vertical) which acts as a support for trash rack and is digged inside 2’ under earth and top end hinged to other ms pipe as per site condition. , supply, erection and commissioning of ms girder – parallel flange section (conforming to is808:2021) size ismb 300 x 140 with primer and bituminous based paint inside & outside. note : 1. removal of existing vt axial flow pumps with motors and after commissioning of work again installation of the same (vt axial flow pumps with motors) will be complete by the agency in all respect including any kind of civil work for various sites. , supply, erection and commissioning oflt power cable – aluminium conductor single core 1000 mm2 xlpe insulated, cores laid up, pvc inner sheathedarmoured(galvanized steel strip) extruded pvc type st2 outer sheathed, 650 v/1100 v grade as per is 7098 with aluminium thimble, nut & bolt and other allied material completed in all respect for various sites. , supply, erection and commissioning oflt power cable – aluminium conductor single core 630 mm2 xlpe insulated, cores laid up, pvc inner sheathedarmoured(galvanized steel strip) extruded pvc type st2 outer sheathed, 650 v/1100 v grade as per is 7098 with aluminium thimble, nut & bolt and other allied material completed in all respect for various sites. , supply, erection and commissioning of lt power cable – lt power cables 3 core x 150 mm² copper conductor xlpe insulated, cores laid up, pvc inner sheathed, armoured (galvanized steel strip), extruded pvc type st2 outer sheathed, 650 v/1100 v grade as per is 7098 with copper thimble, nut & bolt and other allied material completed in all respect for various sites. , supply, erection and commissioning of lt power cable – lt power cables 3 core x 120 mm² copper conductor xlpe insulated, cores laid up, pvc inner sheathed, armoured (galvanized steel strip), extruded pvc type st2 outer sheathed, 650 v/1100 v grade as per is 7098 with copper thimble, nut & bolt and other allied material completed in all respect for various sites. , supply, erection and commissioning of lt power cable – lt power cables 3 core x 95 mm² copper conductor xlpe insulated, cores laid up, pvc inner sheathed, armoured (galvanized steel strip), extruded pvc type st2 outer sheathed, 650 v/1100 v grade as per is 7098 with copper thimble, nut & bolt and other allied material completed in all respect for various sites. , supply, erection and commissioning of lt power cable – lt power cables 3 core x 70 mm² copper conductor xlpe insulated, cores laid up, pvc inner sheathed, armoured (galvanized steel strip), extruded pvc type st2 outer sheathed, 650 v/1100 v grade as per is 7098 with copper thimble, nut & bolt and other allied material completed in all respect for various sites. , supply, erection and commissioning of lt power cable – lt power cables 3 core x 50 mm² copper conductor xlpe insulated, cores laid up, pvc inner sheathed, armoured (galvanized steel strip), extruded pvc type st2 outer sheathed, 650 v/1100 v grade as per is 7098 with copper thimble, nut & bolt and other allied material completed in all respect for various sites. , supply, erection and commissioning of ms delivery pipe 258.9 mm inner dia. ( in approx. 6 meter per pipe) and each pipe of 8 mm thickness both ends welded with flange made ms plate as per approved specification including ht nut and bolts, rubber sheet andother fitmet accessories , supply, erection and commissioning of ms delivery pipe 445.2 mm inner dia. ( in approx. 6 meter per pipe) and each pipe of 8 mm thickness both ends welded with flange made ms plate as per approved specification including ht nut and bolts, rubber sheet andother fitmet accessories , supply, erection and commissioning of ms delivery pipe 711 mm inner dia. ( in approx. 6 meter per pipe) and each pipe of 8 mm thickness both ends welded with flange made ms plate as per approved specification including ht nut and bolts, rubber sheet andother fitmet accessories...

Irrigation Department - Haryana

39275529 supply erection and commissioning of electromechanical equipments like vt pumps, electric motors, ltdb panel with cable, ms girder, grating, trash rack and other allied accessories and accessories at various ph of siwani canal and garanpura ph supply erection and commissioning of electromechanical equipment like vt pumps, electric motors, ltdb panel with cable, ms girder, grating, trash rack and other allied accessories and accessories at various ph of siwani canal and garanpura ph , supply, erection and commissioning of50 cs. vt axial flow pumps of 740 rpm, having static lift of 17.50 feet, including delivery pipe ( 6+6 mtr. ) as per actual size requirement and ms delivery bends of minimum 8mm thickness with bituminous paint inside & outside including flange welding, h.t. nut bolt, siphon braker valve, complete in all respect, as per site and as per approved technical specifications ( for ph 2 siwani canal & ph 3 siwani canal ) , supply, erection and commissioning of 30 cs. v.t. axial flow pumps of 965 rpm, having static lift of 17.5 feet, including delivery pipe ( 6+6 mtr. ) as per actual site requirement and ms delivery bends of minimum 8 mm thickness with bituminous based paint inside & outside including flange welding, h.t. nut bolts, siphon breaker valve, complete in all respect, as per site and as per approved technical specifications. ( for ph 3 siwani canal ) . , supply, erection and commissioning of 10 cs. v.t. axial flow pumps of 1440 rpm, having static lift of 18 feet, including delivery pipe ( 6+6 mtr. ) as per actual site requirement and ms delivery bends of minimum 8 mm thickness with bituminous based paint inside & outside including flange welding, h.t. nut bolts, siphon breaker valve, complete in all respect, as per site and as per approved technical specifications. ( for escape ph 1 &2 siwani canal ) . , supply, erection and commissioning of 40 cs. v.t. axial flow pumps of 980 rpm, having static lift of 17.5 feet, including delivery pipe ( 6+6 mtr. ) as per actual site requirement and ms delivery bends of minimum 8 mm thickness with bituminous based paint including flange welding, h.t. nut bolts, siphon breaker valve, complete in all respect, as per site and as per approved technical specifications. ( for ph 7 siwani canal ) , supply, erection and commissioning ofsolid shaft motor of capacity 225 hp 8 pole, 740 rpm, 3 phase 415 volt with efficiency class ie2 ( as per is 12615 with latest amendments ) suitable for 50 cs vt axial flow pumps type vertical flange mounted & as per approved technical specification with earthing of motor ( for ph 2 siwani canal & ph 3 siwani canal ) , supply, erection and commissioning ofsolid shaft motor of capacity 50 hp 6 pole, 965 rpm, 3 phase 415 volt with efficiency class ie2 ( as per is 12615 with latest amendments ) suitable for 14 cs vt axial flow pumps type vertical flange mounted & as per approved technical specification with earthing of motor ( for ph 1 siwani canal ) , supply, erection and commissioning ofsolid shaft motor of capacity 100 hp 6 pole, 965 rpm, 3 phase 415 volt with efficiency class ie2 ( as per is 12615 with latest amendments ) suitable for 30 cs vt axial flow pumps type vertical flange mounted & as per approved technical specification with earthing of motor ( for ph 3 siwani canal ) , supply, erection and commissioning of solid shaft motor ofcapacity 60 hp of 4 pole, 1440 rpm, 3 phase 415 volt with efficiency class ie2 ( as per is 12615 with latest amendments ) suitable for 10 cs. vt axial flow pumps type vertical flange mounted & as perapproved technical specification with earthing of motor. ( for escape ph 1&2 siwani canal ) . , supply, erection and commissioning of solid shaft motor of capacity 150hp 6 pole, 980 rpm, 3 phase 415 volt with efficiency class ie2 ( as per is 12615 with latest amendments ) suitable for 40 cs. vt axial flow pumps type vertical flange mounted & as perapproved technical specification with earthing of motor. ( for ph 7 siwani canal ) , supply, erection and commissioning of mcc panel of 1600 amp. capacity with all accessories as one incomer acb 4 pole 1600 amp. with 4 no. outgoingeach of having mccb of 630 amp. alongwith an addl. mccb of 100 amp. for lighting loads, indicators, relay, meters, push buttons, bus bars and with 4 no. fully automatic ats starters ( completed in all respect like relays, indicators timer etc. ) . with suitable contactors rating with first filling of oil ( if oil cooled ats used ) with suitable capacitor bank with 8 stepapfcr, digital display instruments & other allied accessories for running of 4 nos. 225 hp motors. each stage should have protection through separate mccb as per approved design of ltdb panel with a stand of ms channel ( 1 ft. up from floor ) & as per approved technical specification with earthing. ( for ph 2 siwani canal ) . , supply, erection and commissioning of 60hp fully automatic starter having 250 amp. mccb, contactors 150, 110, 80a, micro controller based protection relay ct’s including suitable capacitor bank with all respect as per site requirement for 10 cs. vt pumps as per approved technical specifications with earthing. for escape siwani ph no. 1 &2 , supply, erection and commissioning of 100hp fully automatic starter having 300 amp. mccb, contactors 300, 200, 110a, micro controller based protection relay ct’s including suitable capacitor bank with all respect as per site requirement for 20 cs. vt pumps as per approved technical specifications with earthing. for escape siwani ph no. 1 , supply, erection and commissioning of ltdb panel of 1600 amp. capacity with all accessories as one incomer acb 4 pole 1600 amp. with 5 no. outgoingeach of having mccb of 400 amp. alongwith an addl. mccb of 100 amp. for lighting loads, indicators, relay, meters, push buttons, bus bars and with 5 no. fully automatic ats starters ( completed in all respect like relays, indicators timer etc. ) with suitable contactor rating with first filling of oil ( if oil cooled ats used ) with suitable capacitor bank with 8 stepapfcr, digital display instruments & other allied accessories for running of 5 nos. 150 hp motors. each stage should have protection through separate mccb as per approved design of ltdb panel with a stand of ms channel ( 1 ft. up from floor ) & as per approved technical specification with earthing. for ph 7 siwani canal , dry type cast resin voltage step down system ( x’mer, shunt capacitor bank with reactor 200 kvar, vcb panel i / o, 11 kv cable from pole to vcb panel & vcb to transformer, la ( pole ) with counter, la ( line ) , foundation for xmer, chemical earthing ( neutral = 2 nos. body = 2 nos., pole & go switch = 1 no., la = 2 nos. vcb panel = 2 nos. ) , stone pitching, fencing, laying of hdpe pipe for cables, go switch & termination kits ) for 11 / .433kv having capacity of 1.6 mva with transient voltage protection system to protect the x’mer against high voltage surges of make siemens / abb / schneider / ge. the scope also includes inspection by m&m / dhbvn. , dry type cast resin voltage step down system ( x’mer, shunt capacitor bank with reactor 200 kvar, vcb panel i / o, 11 kv cable from pole to vcb panel & vcb to transformer, la ( pole ) with counter, la ( line ) , foundation for xmer, chemical earthing ( neutral = 2 nos. body = 2 nos., pole & go switch = 1 no., la = 2 nos. vcb panel = 2 nos. ) , stone pitching, fencing, laying of hdpe pipe for cables, go switch & termination kits ) for 11 / .433kv having capacity of 1.0 mva with transient voltage protection system to protect the x’mer against high voltage surges of make siemens / abb / schneider / ge. the scope also includes inspection by m&m / dhbvn. , supply, erection and commissioning oflt power cable – aluminum conductor single core 1000 mm2 xlpe insulated, cores laid up, pvc inner sheathedarmored ( galvanized steel strip ) extruded pvc type st2 outer sheathed, 650 v / 1100 v grade as per is 7098 with aluminum thimble, nut & bolt and other allied material completed in all respect ( for garanpura ph 1 rd 46600, garanpura ph 2 rd51050, garanpura ph 3 rd57300, ph 1 siwani canal, ph 2 siwani canal, ph 3 siwani canal, ph 4 siwani canal ) . , supply, erection and commissioning oflt power cable – aluminum conductor 3.5 core 630 mm2 xlpe insulated, cores laid up, pvc inner sheathedarmored ( galvanized steel strip ) extruded pvc type st2 outer sheathed, 650 v / 1100 v grade as per is 7098 1995 with aluminum thimble, nut & bolt and other allied material completed in all respect ( for ph 4 siwani canal & ph 7 siwani canal ) , supply, erection and commissioning oflt power cable – aluminum conductor single core 300 mm2 xlpe insulated, cores laid up, pvc inner sheathedarmored ( galvanized steel strip ) extruded pvc type st2 outer sheathed, 650 v / 1100 v grade as per is 7098 with aluminum thimble, nut & bolt and other allied material completed in all respect. ( for garanpura ph 1 rd 46600, garanpura ph 2 rd51050, garanpura ph 3 rd57300 & ph 7, siwani canal , supply, erection and commissioning oflt power cable – lt power cables 3 core x 185mm2copper conductorxlpe insulated, cores laid up, pvc inner sheathed, armored ( galvanized steel strip ) , extruded pvc type st2 outer sheathed, 650 v / 1100 v grade as per is 7098 with copper thimble, nut & bolt and other allied material completed in all respect ( for garanpura ph 1 rd 46600, ph 1 siwani canal, ph 2 siwani canal, ph 3 siwani canal & ph 7 siwani canal ) . , supply, erection and commissioning oflt power cable – lt power cables 3 core x 120mm2 copper conductorxlpe insulated, cores laid up, pvc inner sheathed, armored ( galvanized steel strip ) , extruded pvc type st2 outer sheathed, 650 v / 1100 v grade as per is 7098 with copper thimble, nut & bolt and other allied material completed in all respect. ( for garanpura ph 2 rd51050 & garanpura ph 3 rd57300 ) . , supply, erection and commissioning of ms girder – parallel flange section ( conforming to is 12778 : 2004 ) size npb 400 x 180 mm2 ( weight per kg / mtr. 66.30 ) with primer and bituminous based paint inside & outside.note : 1. removal of existing vt axial flow pumps with motors and after commissioning of work again installation of the same ( vt axial flow pumps with motors ) will be complete by the agency in all respect with all civil works ( ( for various pump houses of garanpura system & siwani canal system ) . , supply, erection and commissioning of ms components dulyprimer and bituminous based paint inside & outside with all civil work. ( a ) ms grating of size as per actual site requirement. ms grating should be by ms angle 40x40x6 mm & ms flate 40x5 mm ( b ) trash rack of size as per actual site requirement. ms trash rack should be made by ms angle 50x50x6mm & ms flate 50x6 mm...

Haryana Vidyut Prasaran Nigam Limited - Haryana

37747986 tender for installation of 11 kv vcb panel set(15 no.) 2000 amps against augmentation of (1x12.5/16 plus 1x25/31.5 mva) 66/11 kv tfs to (2x12.5/16 mva) 66/11 kv tfs at 66 kv s/stn. ioc, ambala cantt....

Haryana Vidyut Prasaran Nigam Limited - Haryana

37679208 tender for installation of 11 kv vcb panel set (15 no.) 2000 amps against augmentation of (1x12.5/16 plus 1x25/31.5 mva) 66/11 kv tfs to (2x12.5/16 mva) 66/11 kv tfs at 66 kv s/stn ioc, ambala cantt....

Urban Local Bodies - Haryana

37556995 providing transformer, electrical items and nrvs etc for 45 mld at khandsa, gurugram supply and making earth stations by digging with of gi plate earthing 600x600x6mm including gi pipe. gi strip 32x6mm. filling of mixture of common salt and fine charcoal complete all accessories. including gst ) 2 supply, installation. testing and commissioning of 11kv 630 amp 20ka indoor type vcb panel incoming cum outgoing. make abb / crompton / schneider ( including gst ) 3 supply, installation, testing and commissioning of 11kvitt metering panel with ttb, wiring and busbars and following: ( i ) . dhvbn approved make 11 kv current transformer accuracyclass 0.2, ct ratio / 5 amp.. resin cast type. ( ii ) . dhbvn approved make 11kv / 110 v potential transformer. accuracy class 0.2. ( iii ) . 11 kv ht meter. ( including gst ) etc...

Uttar Haryana Bijli Vitran Nigam Limited - Haryana

36294125 procurement of 11 kv vcb panel 11 / xen / p i / mm / qh i / 2579 11 kv vcb panels ic o g capacitor control panel s stn t f panel 11 kv 8 panel board , item , 11 kv vcb panels ( incoming ) , 11 kv vcb panels ( outgoing ) , 11 kv vcb panels ( capacitor control ) , 11 kv s / stn. transformer panel , 11 kv vcb 8 panel board...

Irrigation Department - Haryana

35288165 augmentation of ph dd 1 by. s.e.c. of vcbs, pumps, motors and other electrical equipments supply, erection and commissioning of 30 cs. v.t. mixed flow pump of 970 rpm, having static lift of 28 feet, including delivery pipe, delivery bends of minimum 8 mm thickness with epoxy coatinginside & outside and the y body of pump is in taper shape, so that it will fit in existing 18” diameter of embedded pipe including flange welding, nut bolts, complete in all respect, as per site and as per approved technical specifications ( see annexure a ) 2 supply, erection and commissioning of solid shaft squirrel cage lt 3 phase 415v induction motor for continuous duty, vertical flange mounted of 225 hp of 6 pole, 970rpm, tefc motor of ie 2 ( as per is 12615 with latest amendments ) suitable for 30cs pump complete in all respect &as perapproved technical specification. 3 supply, erection and commissioning of 1000 amp. motor control center with incomer of mccb of 1000amp 4 pole with 03 nos. outgoings ofmccb of 550 amp each along with an additional mcb of 63 amp for lighting loads, indicators, relays, meters, push buttons, bus bars and with 03 nos. fully automatic ats starters ( complete in all respect like relays, indicators timer etc. ) of 225 h.p. each with contactor rating as 630a, 400a, 225 ampere suitable for 03 nos. 225 h.p lt motor as per design with stand of ms channel / angle ( 1 feet height from floor level ) & as per approved specification of deptt. ( as per annexure c ) 4 supply, erection and commissioning of 1 no. ltdb with 01 no. incomer of 1600 amp. with 04 nos. of outgoings out of which 03 nos. of having mccb of 800 amp. and 01 no of mccb of 630 amp. ( should be having enough space for connection of 2 incomer cables from transformer and 1 no. from capacitor bank ) along with d plug socket 63 amp mccb for lighting loads, indicators, relays, meters, push buttons, bus bars suitable, with a stand of ms channel ( 1 feet up from floor ) ip 54 & as per approved technical specification. 5 supply, erection and commissioning of 11 kv vcb panel ( 4nos. for operation & 1 nos. in spare ) , 02 nos. incomer vcb of 400 amp. and 3 nos. outgoing of 400 amp. with a provision such that 2 nos. outgoing vcbs connected with bothtransformers and 01 no. in spare ) with 26.20 ka breaking capacity along with ct / pt of required capacity including the 24v dc operated relays for fault circuit, lightening indicators, relays, meters, push buttons etc., earth fault and overloading on all feeder and incomers. each vcb should have metering equipment and safety devices as per specification ( annexure. – c ) . each incomer should have tripping function for ltdb panels and starters, earth faults, under voltage / overvoltage and phase indicators. each outgoing should have relay for overloading, earth fault, & short circuit. the scope of work also includes heavy duty battery operated charger for ensuring 24 hours relay operation. both incomer be connected with linkage coil / change over so that 1 incomer be functional at one time. 6 providing and fixing of suitable capacity outdoor type ( moisture / sand / water proof ) capacitor with resin cast insulation to be coupled with upto 1.6 mva transformer to compensate its losses 11 kv complete with cable connection / conductor connection with accessories with manual and automatic selector switch, indicators, on / off switches including nut bolt etc. with suitable fixings / stand ( 4 feet height above from floor level. ) and as per approved specification of the deptt. 7 providing and laying of 11 kv xlpe cable, armoured, aluminum conductor 3 core 120 mm2 ht cables for the connection of vcb to transformer and ht pole to vcb by fixing suitable size cable box at both ends. 8 providing and fixing of lightening arrester with protection radius of 100mtr. along with its earthing and counter as per the site requirement. 9 providing and fixing of chemical earthing by digging 200 mm bore, 20 feet depth complete with gi electrode with gi strip ( 02 no. for each transformer, 01 no. for vcb, 01 no. for fencing, 02 nos. for ltdb panels & motors in pump house ) and coke & salt etc. along with name plate complete as per requirement. 10 providing and fixing of chemical earthing by digging 200 mm bore, 10 feet depth complete with copper electrode with copper strip for neutral of each transformer and coke & salt etc. along with name plate complete as per requirement. 11 supply, and laying of single core cable aluminum conductor 1000mm2 xlpe insulated, armoured lt cable from transformer to panel with thimbles. 12 supply, erection and commissioning of capacitor bank of 330 kvar capacity ip 54 with 8 step automatic power factor controller unit, suitable size mccb, duty contactors, discharge registers, display unit, on / off switches, selector switch automatic as well as manual, indicators and all other related components with xlpe insulated armored cable of suitable size of length 30 feet each to connect the capacitor bank with existing lt panels with stand of ms channel, angle ( 1feet height above from floor level. ) and as per approved specification of the deptt. 13 supply, erection and commissioning of lt 3.5 core cable aluminum conductor 400mm2 xlpe insulated, armored cable from panel to motors by providing suitable size thimbles at both ends and with suitable fitting on wall mounting angle support along the wall. 14 supply, erection and commissioning of lt 3.5 core cable aluminum conductor 630mm2 xlpe insulated, armored cable from starter to motors by providing suitable size thimbles at both ends and with suitable fitting on wall mounting angle support along the wall. 15 supply, erection and commissioning of lt single core cable aluminum conductor 630 mm2 xlpe insulated, armored cable from neutral of transformers to ltd panels by providing suitable size thimbles at both ends. 16 providing and fixing of foundation for 03 nos. 30cs. vt pump by making required size / length at site from ismb of size 500x180mm approximate 3600 mm length 02nos ( 01 set for each pump foundation ) . 02nos. shall be grouted into the wall by making arrangement of pcc ( 1:1.5:3 ) as per the weight of pump while other ends should be welded with fixing if a.i.l. bracket and nut / bolts / washers to existing ismb including material and labour for applying primer and 02 coats of epoxy paint on the complete foundation and labour charges for taking out old rusted foundation ( pumps p 1, 2, 3 of dewana canal ) make – tata / sail / vizag 17 make of pumps kirloskar, wilo, flowmore, wpil, xylem, gita ( upto 60 cs. ) & sintech ( upto 60 cs. ) .make of motors lv motor marathon, abb, kirloskar electric, siemans, crompton, jyoti, bch, bharat bijli.make of panels lv panel siemans, abb, l&t, schneider, g.e. c&s, havells, bch, alstom, legrand, ae & psg ( upto 30 hp ) .terms & conditions: 1. the tender rate will be inclusive all taxes as applicable including gst.2. the tender rate will be for f.o.r. destination and inclusive of all incidental charges, enroute & at destination. nothing extra shall be paid separately.3. wwc@1% will be deducted from the each bill of the agency.4. department will not be responsible for non submission of boq / bid document online by due date, due to any fault of internet / e tendering.5. third party testing by t.p.i.a. will be carried out in the presence of departmental representative at the manufacturer premises and cost of the same will be borne by the successful agency. 6. the warranty of the work shall be as per service level agreement from the date of commissioning. 7. time period for completion of work 8 months from the issue date of order to proceed with the work.8. payment schedule, as per bidding documents & 70% payment be made as per pro rata basis. 9. payment shall be made on finished goods and not on casting only.10. the material will be supplied as per drawing and newly approved technical specifications laid down in tender documents & subsequent submission by bidder in this regard.11. authorization from oem ( pump, motor ) be attached if tenderer is not a manufacturer. 12. each page of bid book will be signed by the tenderer as a token of acceptance of terms and conditions.13. bidders may visit to the sites before quoting the tender rates.14. bidders should have executed similar nature work in any center government / state government / public sector undertaking / central autonomous body for minimum value equivalent to 50 % of quoted value in last 3 years alongwith existing criteria as per bid i.e. bidder should have completed at least 25% of quantity of similar nature work.15. ln case, the material offered for inspection by the firm fails to meet the specifications stipulated in nit / order / contract and the samples are rejected by the inspecting committee, the department will have the right to levya penalty at 0.1% of the total value of that particular item.16. bidders who will be rejected during technical scrutiny, will submit their representation within 5 days from issue of minutes of tsc.17. affidavit on non judicial stamp paper of rs. 100 / duly certified by the notary stating that the firm ( name of the firm ) has not been blacklisted / debarred either in government departments / agencies in state of haryana or central government departments / agencies etc. as on the date of submission of the bid in the present tender.18. bidders should have average annual financial turnover of atleast 30% of estimated amount during the last 03 financial years, ending 31st march of previous financial year. this should be duly audited by chartered accountant.19. concession is given to haryana based msme’s, kviu, central or hpse ( as declared by industries department haryana ) as in tender fee, emd, past experience and eligibility criteria for turnover. though they have to complete the job as per tender with warranty of 5 years or 12500 hours which ever is earlier as per service level agreement. only those msme, kviu, central or hpse ( as declared by industries department haryana ) will be eligible for this tender, those are authorized dealer or manufacturer of approved make of iwrd....

Northern Railway - Haryana

35254593 electrical work in connection with provision of new ht vcb panels & other associate work at jagadhari workshop railway colony sub stn no 1 & 3, bti & sir and improvement of infrastructure of ht supply at bti over umb division...

Haryana Vidyut Prasaran Nigam Limited - Haryana

34347885 providing 11kv vcb panel set ( 1250a ) against replacement of old and obsolete 11kv vcb panel set ( electroteknica make ) on 12.5 / 16 mva, 66 / 11kv t / f t 2 at 66kv sub station sector 3, panchkula during the year 2022 23.2. replacement of 01 no. old & obsolete 66kv circuit breaker installed on 66kv s / c pinjore to mansa devi line ( c 10 ) at 220kv sub station pinjore, during the year 2022 23.3. replacement of 01 no. old & obsolete 66kv circuit breaker installed on 66kv s / c sector 32 to pinjore line ( c 2 ) at 220kv sub station pinjore, during the year 2022 23.4. replacement of 01 no. old & obsolete 132kv circuit breaker installed on 132kv d / c pinjore to ropar line ( ckt 1 ) at 220kv sub station pinjore, during the year 2022 23.5. replacement of 1 no. 132kv l&e of pinjore to ropar line ( ckt 1 ) at 220kv s / stn pinjore....

Haryana Vidyut Prasaran Nigam Limited - Haryana

34155851 1.providing 11kv vcb panel set 1250a against replacement of old and obsolete 11kv vcb panel set cgl make on 12.5 16 mva 66 11kv tf t 1 at 66kv s stn. berkheri. 2.providing 01 no. 12.5 16 mva 66 11kv and 01 no. 10 16 mva 132 11kv tf at 132kv...

Haryana Vidyut Prasaran Nigam Limited - Haryana

34144058 for replacement of 01 no.11kv vcb panel set of 25 / 31.5mva, 66 / 11kv t 1 transformer at 220kv s / stn. sector 46, faridabad replacement of 01 no. 11kv vcb panel set of 25 / 31.5mva, 66 / 11kv t 1 transformer at 220kv s / stn. sector 46, faridabad...

Northern Railway - Haryana

34083279 supply installation & commisioning of various items for ht panelsupply installation & commisioning of various items for ht panel, supply installation testing and commissioning of epoxy fiber sheet phase separator suitable for andrew yule make 11 kv ht panel. , supply installation testing and commissioning of ht epoxy paint ( denson, burzer, asian ) in 11 kv ht panel of andrew yule make bus bar chamber and inside. , supply installation testing and commissioning of post insulator of 11kv vcb panel rated current 630 amp as per attached drawing and suitable for andrew yule & co. ltd make ht panel as per attached sample drawing . , supply installation testing and commissioning of bus bar bushing insulator 11kv vcb panel rated current630 amp as per attached drawing and suitable for andrew yule & co. ltd make ht panel as per attached sample drawing . . page 1 of 4 run date / time: 23 / 09 / 2022 17:18:55judw / northern rly tender document => limited...

Northern Railway - Haryana

33839647 supply installation & commisioning of various items for ht panelsupply installation & commisioning of various items for ht panel, supply installation testing and commissioning of epoxy fiber sheet phase separator suitable for andrew yule make 11 kv ht panel. , supply installation testing and commissioning of ht epoxy paint ( denson, burzer, asian ) in 11 kv ht panel of andrew yule make bus bar chamber and inside. , supply installation testing and commissioning of post insulator of 11kv vcb panel rated current 630 amp as per attached drawing and suitable for andrew yule & co. ltd make ht panel as per attached sample drawing . , supply installation testing and commissioning of bus bar bushing insulator 11kv vcb panel rated current630 amp as per attached drawing and suitable for andrew yule & co. ltd make ht panel as per attached sample drawing . . page 1 of 4 run date / time: 07 / 09 / 2022 12:56:28judw / northern rly tender document => limited...

Northern Railway - Haryana

33839600 supply of supply installation & commisioning of various items for ht panelsupply installation & commisioning of various items for ht panel, supply installation testing and commissioning of epoxy fiber sheet phase separator suitable for andrew yule make 11 kv ht panel. , supply installation testing and commissioning of ht epoxy paint ( denson, burzer, asian ) in 11 kv ht panel of andrew yule make bus bar chamber and inside. , supply installation testing and commissioning of post insulator of 11kv vcb panel rated current 630 amp as per attached drawing and suitable for andrew yule & co. ltd make ht panel as per attached sample drawing . , supply installation testing and commissioning of bus bar bushing insulator 11kv vcb panel rated current630 amp as per attached drawing and suitable for andrew yule & co. ltd make ht panel as per attached sample drawing . . page 1 of 4 run date / time: 07 / 09 / 2022 13:04:32judw / northern rly tender document => limited...

Haryana Vidyut Prasaran Nigam Limited - Haryana

31373137 providing 11kv vcb panel set 1250 a against replacement of old and obsolete 11kv vcb panel set bhel make on 12.5 16 mva 6611kv t f t 1 at 66kv s stn. sec 3 panchkula during the year 2021 22. providing 11kv vcb panel set 1250 a against replacement of old and obsolete 11kv vcb panel set bhel make on 12.5 16 mva 6611kv t f t 1 at 66kv s stn. sec 3 panchkula during the year 2021 22....

Uttar Haryana Bijli Vitran Nigam Limited - Haryana

30720822 tender for 11 kv vcb panels ic og og substation tf 11 kv vcb panels ic og and og substation tf ) as per nigams specification no. csc 81 r iv dh uh p d2020 21 , items , 11 kv vcb panels ( incoming ) , 11 kv vcb panels ( outgoing ) , 11 kv o / g vcb for sub station transformer...

Haryana Vidyut Prasaran Nigam Limited - Haryana

30298528 providing 11kv vcb panel set 13 nos. against replacement of old and obsolate 06 no. 11kv vcb panel set s and s make on 10 12.5 mva 66 11kv tf t 4 at 220kv s stn. pinjore during the year 2021 22. providing 11kv vcb panel set 13 nos. against replacement of old and obsolate 06 no. 11kv vcb panel set s and s make on 10 12.5 mva 66 11kv tf t 4 at 220kv s stn. pinjore during the year 2021 22....

Northern Railway - Haryana

30275343 supply of panel itemspanel items,drive mechanism of 11 kv vcb panel rated current 630 a. make andrew yule & co. ltd. , pt fuse of 11 kv vcb panel rated current 630 a. make andrew yule & co. ltd. , catch mechanism of 11 kv vcb panel rated current 630 a. make andrew yule & co. ltd. , spring charging motor 230 v ac of 11 kv vcb panel rated current 630 a. make andrew yule & co. ltd. page 1 of 5 run date/time: 14/12/2021 13:39:23judw/northern rly tender document , trip coil 110v dc of 11 kv vcb panel rated current 630 a. make andrew yule & co. ltd. , closing coil 110 v dc of 11 kv vcb panel rated current 630 a. make andrew yule & co. ltd. , auxiliary plug & socket 19 pin of 11 kv vcb panel rated current 630 a. make andrew yule & co. ltd. , limit switch (1 no+ 1 nc) of 11 kv vcb panel rated current 630 a. make andrew yule & co. ltd. , post insulator 11 kv of 11 kv vcb panel rated current 630 a. make andrew yule & co. ltd. , plr relay of 11 kv vcb panel rated current 630 a. make andrew yule & co. ltd....

Haryana Vidyut Prasaran Nigam Limited - Haryana

30121425 1.de moisture de carbonization and anti tracking coating on 11kv vcb panels make cgl associated with tf t 1 at 66kv s stn. shahzadpur. 2.providing floor insulating coating in front of 11kv vcb panels of 12.5 16mva 66 11kv tf t 4 at 220kv s stn. mpur 1.de moisture de carbonization and anti tracking coating on 11kv vcb panels make cgl associated with tf t 1 at 66kv s stn. shahzadpur. 2.providing floor insulating coating in front of 11kv vcb panels of 12.5 16mva 66 11kv tf t 4 at 220kv s stn. mpur...

Haryana Vidyut Prasaran Nigam Limited - Haryana

29548593 work for replacement of 11kv vcb panel set at 132kv murthal and 220kv snp and replacement of 33kv breakers at 220kv substation mohana sonipat work for replacement of 11kv vcb panel set at 132kv murthal and 220kv snp and replacement of 33kv breakers at 220kv substation mohana sonipat...

Haryana Vidyut Prasaran Nigam Limited - Haryana

29269042 enit 17 / ysynr / 2021 22 dated 20.09.2021 moisture cleaning and insulation coating on 11 kv bus bar of vcb panels of 66 / 11 kv 25 / 31.5 mva transformer t 1 at 66 kv sub station chhachhrauli. ( including labour and material ) ...

Haryana Sugar Federation - Haryana

28709683 checking and repairing of 11 kv, h.t breakers vcb & panel checking and repairing of 11 kv, h.t breakers vcb & panel.detail of works a. relay testing, checking of bus bar and insulation, tightness of bus bar, t & c switch operation, wire tightness, c.t & p.t checking and testing etc. b. total quantity of bearker 09 nos. 630 a 06 nos. 1600 a 03 nos. make kirloskar c. total quantity of ht panels – 07 nos. ( distribution t / f ) 630 a 04 nos. fibrizer panel 02 nos....

Department Of Atomic Energy - Haryana

28617387 supply, installation, testing & commissioning of 33kv vcb panel, 33/0.433 kv, 2.5mva onan transformers with oltc & rtcc, ht & lt cables, lt panels and associated works for gcnep campus site at kheri jassaur, bahadurgarh, haryana....

Haryana Urban Development Authority - Haryana

27701455 repair of vcb panel including changing of isolator body , fuse holder , battery , copper strip etc , in sec 75 to 89 , faridabad . ( including 1 year defect liability period free of cost ) . ...

Haryana Vidyut Prasaran Nigam Limited - Haryana

27477981 cleaning of moisture and providing insulation coating on 11 kv bus bar of 08 no . 11 kv vcb panels ( 4 no . mei make and 4 no . cgl make ) of 10 12 . 5 mva 66 11 kv transformer t 2 at 66 kv sub station hvpnl , gangori...

Public Health Engineering Department - Haryana

27238392 rate contract for comprehensive maintenance & special repair of vcb panels & lt distribution panel of different makes/company installed atall p/houses of m/garh canal under m/garh ws mech division narnaul....

Department Of Irrigation - Haryana

27197491 rate contract for comprehensive maitenance and special repair of vcb panels and lt distribution panel of different makes company installed at all pump houses of mgarh canal under mgarh ws mech division narnaul . ...

Uttar Haryana Bijli Vitran Nigam Limited - Haryana

26678175 11 kv vcb panels outdoor type in kiosk type housing ic og cc or panel boards 11 kv vcb panels outdoor type in kiosk type housing ic og cc or panel boards as per nigam specification relevant iss with latest amendments , items , 11 kv vcb panels ( outdoor type in kiosk type housing incoming , 11 kv vcb panels ( outdoor type in kiosk type housing outgoing , 15 panels board ...

Haryana Vidyut Prasaran Nigam Limited - Haryana

26159960 moisture cleaning and insulation coating of 11kv vcb panels11kv bus bar posts clusters at 132kv sstn jhajjar and beri b plugging of oil leakage of 2025 mva 13233 kv tf t 3 installed at 132 kv substation hvpn matanhail , a ) moisture cleaning and insulation coating of 11kv vcb panels , 11kv bus bar , posts , clusters at 132kv s / stn jhajjar & 132kv s / stn beri . b ) providing of oil plugging compound and plugging of oil leakage from top plate of main body , radiator , inspection window , oltc of 20 / 25 mva , 132 / 33 kv t / f t 3 installed at 132 kv sub station , hvpn matanhail...

Haryana Vidyut Prasaran Nigam Limited - Haryana

26033615 replacement of old obsolete 11 kv vcbs panel board set of 132 / 11 kv , 10 / 16 mva t 2 t / f at 132 kv s / stn . , hvpnl , amin replacement of old / obsolete 11 kv vcb panel board set of 132 / 11 kv , 10 / 16 mva t 2 t / f at 132 kv s / stn . , hvpnl , amin...